Dome Fiber Optic Splice Kaw

Xa kev nug
Dome Fiber Optic Splice Kaw
Paub meej
Qauv: GL-5601 Dome Fiber Optic Splice Kaw
Yog tias koj tab tom qhia txog lub dome splice kaw rau FTTH rollout, 5G fronthaul infrastructure, los yog lub cev cable faib, lub GL-5601 npog cov ntsiab cai - IP68 foob, 144-fiber ib leeg / 432-fiber ribbon muaj peev xwm, thiab ntau hom mounting kev them nyiaj yug - tsis tas yuav tsum tau cais burial KU.
Kev faib tawm yam khoom
Fiber Optic Enclosure
Share to
Hauj lwm lawm

GL-5601 Dome Fiber Optic Splice Kaw yog dab tsi?

Lub GL-5601 yog lub dome ntsug- hom fiber ntau optic splice kaw (tseem hu ua dome enclosure, dome joint box, lossis fiber optic sib koom enclosure). Nws nyob hauv tsev thiab tiv thaiv fiber ntau fusion splices ntawm sab nraum zoov cov ntsiab lus nrog rau saum huab cua spans, duct khiav, ncaj qha - faus txoj kev, phab ntsa -mount, thiab manhole vault installations. Cov input/output ports nyob rau tib sab - classic dome form factor for butt-splice and branch-splice configurations.

Dome Fiber Optic Splice Closure

Vim li cas thiaj xaiv Fiber Distribution Terminal?

Fiber Optic Splice Closure
01

IP68 tiv thaiv rau ib puag ncig huab cua

Silicone sealing cov ntsiab lus - tsis yog butyl daim kab xev - tiv thaiv kev laus, UV tawg, thiab compression creep. Rated IP68: submersible rau 1m rau 48 teev. Re- nkag tau thiab rov siv tau yam tsis tau hloov cov khoom foob.

02

Cov cuab yeej-Dawb Re- Nkag mus

Tshuab compression los ntawm yas hoop thiab screws - tsis muaj phom kub, tsis muaj mastic, tsis muaj cov cuab yeej tshwj xeeb yuav tsum tau. Re- nkag mus rau kev saib xyuas lossis ntxiv fiber ntau yog ib qho haujlwm - theem, tsis yog kev ua haujlwm tshwj xeeb.

Dome Fiber Optic Splice Closure pc shell

High-Strength PC Shell
03

Siab -Lub zog PC Plhaub

Engineering- qib polycarbonate tsev nyob tiv thaiv UV hluav taws xob, corrosion, thiab txhua yam cuam tshuam los ntawm kev ua haujlwm kub ntawm −40℃rau +70℃. Tsis muaj yellowing los yog embrittlement nyob rau hauv lub hnub raug lub sij hawm ntev.

Core Specifications

Dome Fiber Optic Splice Closure specifications

Cov no yog cov lej los kuaj thawj zaug thaum ntsuas qhov chaw tsim nyog. Them tshwj xeeb rau cable nkag qhov chaw nres nkoj diameters - feem ntau yuam kev yuam kev yog qhia txog qhov kaw uas yuav tsis haum rau lub feeder cable lub tsho sab nraud txoj kab uas hla.

 

Parameter Specification
ModelItem code Qauv TSIS MUAJ: GL-5601
Zuag qhia tag nrho DimensionsH × Diameter 460 × Φ225 hli
Plhaub Xim Dub (kev cai muaj)
Cable Entry PortsPort hom / cable OD 1 × oval nthuav qhia chaw nres nkoj + 4 × round ports
Tau tshaj Φ8 - Φ18 mm cables
Ingress ProtectionTested tus qauv IP68 (submersible)
Txoj Kev Sealing Silicone ntsiab + mechanical compression hoop
Max Splice Peev Xwm - Ib leeg Fiber 144 cev
Max Splice Peev Xwm - Ribbon Fiber 432 cev
Lub tais muaj peev xwm - Ib leeg 24 cores rau ib lub tais
Lub tais muaj peev xwm - Ribbon 72 cores rau ib lub tais
Max Tais 6 pcs (sackable)
PLC Splitter Qhov 1 pcs integrated
Plhaub Khoom High -lub zog engineering PC (polycarbonate)
Ua haujlwm kub -40℃rau +70 degree
Mounting OptionsTag nrho ntawm tib lub tsev Aerial / Phab ntsa / Ncej / Manhole / Direct faus
Sab hauv Carton DimensionsSingle unit 475 × 235 × 205 hli
Outer Carton Dimensions6 units ib lub thawv 740 × 590 × 450 hli

 

Splice Tray Configurations

Muaj ob hom tais. Xaiv raws li qhov sib txawv ntawm qhov sib txawv thiab koj pab pawg tus qauv splice lub tes tsho:

Hom tais Lub tes tsho tuav Style Zoo tshaj rau
7# Splice Tais Standard sib nrug tes tsho Txuj ib zaug -fiber fusion splices; feem ntau xa mus
8 # Splice Tais Extended / reinforced lub tes tsho tuav Lub tes tsho loj dua; ribbon fiber ntau configuration; siab - txoj kev nro

 

Qhov twg GL-5601 tau xa mus

Lub dome form factor yog qhov kev xaiv zoo thaum cables nkag los ntawm ib qho kawg (lub taub qab-splice topology) thiab koj xav tau ib lub kaw lus compact los tuav lub cev hla dhau -los ntawm ntxiv rau ceg faib - uas suav nrog kev nkag mus rau feem ntau- cov qauv kev xa tawm network.

FTTH / FTTx Sab Nraud Distribution

Tiv thaiv splices ntawm sab nraum zoov splitter ntsiab lus thiab feeder - mus rau - faib cable junctions hauv FTTH, FTTB, thiab FTTC tes hauj lwm. Fits standard handhole wells - the Φ225mm dome body clears typical low-nruas qhov dej tsis tas yuav tsum muaj lub vault loj.

5G Fronthaul & Backhaul

Siv rau kev tiv thaiv splice hauv fronthaul optical cables txuas BBU thiab RRU khoom. Qhov ntsuas IP68 thiab qhov ntsuas kub dav dav ua rau nws siv tau rau ncej- sab nraum zoov xa tawm ntawm cov chaw ntawm tes.

Ntev -Nkaus Kab Kab

Ua raws li cov relay splice node ntawm cov raj xa dej -piv los yog aerial optical cable qaum txoj hauv kev. Qhov chaw nres nkoj oval nthuav dav kom haum rau loj -OD feeder cables thaum plaub ceg chaw nres nkoj ua haujlwm rau sab nraud.

MDU / Campus Networks

Phab ntsa-mounted lossis ncej-mounted ntawm lub tsev cov ntsiab lus nkag hauv ntau- tsev nyob lossis tsev kawm ntawv fiber ntau topologies, tswj cov splices los ntawm riser mus rau kev faib tawm-cov fibers.

Underground / Manhole Vaults

IP68 waterproofing lis dej nyab raws sij hawm muaj nyob rau hauv manhole thiab handhole ib puag ncig. Lub silicone foob tswj kev ncaj ncees los ntawm kev sib cuag nrog dej tsis muaj degrading zoo li butyl mastic.

Railway & Highway Infrastructure

Aerial thiab duct- txoj kev fiber ntau splice tiv thaiv raws txoj kev tsheb ciav hlau thiab txoj kev loj kev sib txuas lus cables. Mechanical hoop kaw withstands vibration cycles tsis muaj foob creep.

Yuav ua li cas rau nruab Dome Fiber Optic Splice Kaw

Kev teeb tsa yog thaj chaw - qib haujlwm - tsis muaj cov cuab yeej tshwj xeeb, cov nplaum, lossis cov khoom siv cua sov xav tau. Hauv qab no yog cov txheej txheem ua haujlwm rau GL-5601. Tag nrho cov kauj ruam- cov lus qhia los ntawm kauj ruam thiab cov yeeb yaj kiab teeb tsa muaj nyob rau ntawm kev thov.

Kev Npaj Qhov Chaw & Kev Tso Cai Cable

Ntxuav qhov chaw installation. Tso cov cables tuaj thiab txiav txim siab txoj kev. Nyob rau sab nraum zoov / huab cua ib puag ncig, tsa lub tsev pheeb suab tiv thaiv huab cua yog tias cov xwm txheej ntub dej lossis plua plav - cov ntsiab lus sib kis tsis raug raws li IP68 kuaj.

Txiav txim siab Stripping Length

Rau tag nrho -txoj kev teeb tsa, xa mus rau Drawing 3A. Rau kev sib xyaw ncaj- dhau ntawm + ceg, siv Drawing 3B. Tuav qhov ntev fiber ntau ua ntej stripping - kev ua yuam kev ua haujlwm yog stripping luv dhau, yuam kev pabcuam loops uas tsis haum rau hauv lub tais.

Sawb Cable Jacket & Npaj Fibers

Tshem lub tsho sab nrauv rau qhov cim ntev. Yog tias nyuaj rau rub ib zaug, strip hauv cov ntu kom tsis txhob muaj fiber ntau tawg. Cua ob txheej ntawm rwb thaiv tsev daim kab xev rau ntawm lub tsho stub rau kev tiv thaiv. Sib cais thiab huv si ib tus neeg fiber cores.

Anchor Cables nyob rau hauv cov chaw nres nkoj nkag

Txoj kev cables los ntawm silicone chaw nres nkoj seals. Rau qhov chaw nres nkoj oval nthuav qhia, xaub lub cable los ntawm nrog cov silicone gasket nyob rau hauv qhov chaw thiab ceev cov neeg kho tshuab ntsia hlau. Rau cov chaw nres nkoj puag ncig, siv cov kab uas tsim nyog silicone ntxig. Cables yuav tsum tau kho - lub sealing yuav tsum tau axial compression los ntawm cov ntxig cable tiv thaiv lub gasket.

Splice & Load Trays

Ua fusion splices thiab thauj fiber ntau xaus rau hauv cov tais diav ntim khoom. Coil tshaj fiber ntau li 100mm- txoj kab uas hla. Muab cov tais tso rau hauv qab; sau txhua lub tais nrog cov khoom siv fiber ntau ua ntej txhim kho.

Kaw & Compress

Zaum lub plhaub dome hla lub hauv paus phaj. Txuas cov yas hoop thiab zawm compression screws tusyees (hla- qauv, tsis ua raws) kom ntseeg tau tias txawm foob compression nyob ib ncig ntawm lub perimeter. Tsis txhob overtighten - silicone foob yuav tsum tau nruab nrab clamping quab yuam nkaus xwb.

Mount & Verify

Txuas rau ncej, xaim xaim, phab ntsa bracket, lossis qis dua rau hauv qhov tuav / manhole raws li muaj. Ua OTDR kab los txheeb xyuas qhov poob ntawm kev sib tsoo ua ntej muab khi rau qhov chaw teeb tsa.

Cov lus nug nquag

1. Dab tsi yog qhov dome fiber optic splice kaw?

Lub dome fiber optic splice kaw (tseem hu ua dome enclosure, dome joint box, los yog ntsug splice kaw) yog ib qho kev tiv thaiv sab nraum zoov rau fiber ntau fusion splices ntawm lub network junction point. Nws feem ntau muaj lub dome- zoo li sab saum toj nrog tag nrho cov chaw nres nkoj cable ntawm ib kawg - qhov "qab" configuration - ua rau nws zoo tagnrho rau cov ceg thiab lub cev sib txuas topologies.

2. Qhov sib txawv ntawm lub dome kaw thiab inline (kab rov tav) splice kaw yog dab tsi?

Dome kaw (xws li GL-5601):​ Txhua qhov chaw nres nkoj cable yog nyob ntawm ib kawg. Qhov zoo tshaj plaws rau pob tw-splice topologies qhov twg lub feeder cable nkag mus thiab ceg cables tawm ntawm tib sab. Compact hneev taw - haum me me handholes thiab pedestals. Standard xaiv rau FTTH faib cov nodes.
Inline / kab rov tav kaw: Cable ports ntawm ob qho kawg. Tsim los rau nruab nrab -span splicing ntawm ntev ncaj cable khiav qhov twg cables nkag los ntawm opposite sab. Feem ntau hauv cov pob txha pob txha txoj kev thiab submarine cable tu cov ntsiab lus.
Txoj cai ntawm tus ntiv tes xoo: yog tias koj tab tom txiav tawm ntawm lub xaim hluav taws xob ntawm qhov taw tes, siv dome. Yog tias koj tab tom txuas lub cable tawg lossis txuas ntxiv txoj hauv nruab nrab - ncua, siv hauv kab.

3. Kev tiv thaiv IP68 txhais li cas rau kev kaw fiber ntau?

IP68 yog tus qauv siab tshaj plaws tiv thaiv kev ntsuas. Lub "6" txhais tau tias ua tiav plua plav- tiv thaiv nruj; lub "8" txhais tau hais tias qhov kaw tuaj yeem tiv taus qhov dej tsis tu ncua hauv dej dhau 1 meter qhov tob rau lub sijhawm teev tseg - hauv GL-5601 cov ntaub ntawv, kuaj ib qho chaw tsim khoom tshwj xeeb.
Hauv kev xyaum, IP68 txhais tau hais tias kev kaw yog tsim nyog rau: kev teeb tsa hauv av hauv av raug dej nyab raws caij nyoog, kev faus ncaj qha rau hauv thaj chaw uas muaj cov rooj dej siab, thiab kev xa tawm ntawm lub qhov rooj rau qhov chaw uas muaj dej sawv ntsug. Lub kaw lus silicone sealing hauv GL-5601 tuav qhov kev ntsuas no hla ntau lub sijhawm re- nkag mus - tsis zoo li butyl mastic, uas tuaj yeem degrade tom qab ob lossis peb rov qhib dua.

4. Muaj pes tsawg fibers tau GL-5601 dome kaw tuav?

GL-5601 txhawb nqa txog 144 fibers ib leeg (siv 6 lub tais × 24 fibers rau ib lub tais) lossis 432 ribbon fibers (siv 6 tais × 72 fibers rau ib lub tais). Ib qho kev sib koom ua ke PLC splitter qhov tseem suav nrog.
Kev teeb tsa dav dav: 24F, 48F, 72F, 96F, 120F, thiab 144F. Rau qhov muaj peev xwm loj dua (txog 288F ib leeg lossis 576F ribbon), peb muab GL-5601-L txuas ntxiv qauv - nug txog qhov no hauv koj qhov kev nug.

5. Lub dome kaw no puas tuaj yeem siv rau kev faus ncaj qha?

Yog lawm. Lub GL-5601 yog ntsuas rau ncaj qha faus, hauv av duct, aerial, ncej-mount, thiab phab ntsa-mount installations siv tib lub hardware - koj tsis xav tau ib tug cais SKU rau txawv nteg txoj kev. IP68 waterproof silicone foob tuav cov dej noo raug raug ntawm qhov chaw faus ncaj qha. Lub cev muaj zog PC lub plhaub tiv thaiv compression loads thiab av sib cuag.
Lus Cim: Rau kev faus ncaj qha, peb pom zoo kom muaj UV ntxiv - daim kab xev ceeb toom ruaj khov ntawm qhov faus qhov tob thiab ua kom cov kab mob sib kis - cov clamps nyem kom raug torqued ua ntej backfilling - kev co thaum lub sij hawm compaction tuaj yeem loosen mechanical compression fittings yog tias tsis raug torqued.

6. Dab tsi yog qhov txawv ntawm mechanical seal thiab heat shrink seal dome kaw?

Mechanical foob (GL-5601 hom): ​​Siv silicone gaskets compressed los ntawm kaw hoop. Re- nkag tau yam tsis muaj cuab yeej lossis khoom siv cua sov. Lub foob tuaj yeem kuaj xyuas thiab rov siv dua. Qhov zoo tshaj plaws rau cov chaw uas yav tom ntej rov- nkag rau fiber ntau ntxiv lossis kev saib xyuas yuav tsum tau - feem ntau FTTH thiab nkag mus rau kev xa tawm network.
Thaum tshav kub kub shrink seal: ​​Ib lub tshav kub-shrink tes tsho bonds kaw rau lub tsho cable mus tas li. Muab kev foob zoo heev tab sis yog kev puas tsuaj rau rov- nkag - lub tes tsho yuav tsum tau txiav thiab hloov. Qhov zoo tshaj plaws rau siab heev - daim ntawv thov nyob mus ib txhis (submarine, ntev -haul caj qaum) qhov twg re- nkag yog tsawg thiab qhov siab tshaj plaws thawj zaug foob kev ncaj ncees yog qhov tseem ceeb.
Peb tsim ob hom. Lub GL-5601 siv cov tshuab foob; Kub-shrink variants muaj nyob rau hauv GL-5602 series.

7. Puas yog GL-5601 txhawb ribbon fiber ntau splicing?

Yog lawm. Lub 8 # splice tray configuration txhawb ribbon fiber ntau txog 72 cores ib lub tais, rau qhov siab tshaj plaws ntawm 432 ribbon -fiber cores nyob rau hauv tag nrho loaded GL-5601. Ob leeg 7 # (ib leeg fiber ntau) thiab 8 # (ribbon fiber) cov tais tuaj yeem nyob hauv tib qhov kaw - muaj txiaj ntsig thaum koj tswj hwm kev sib xyaw ntawm cov qub txeeg qub teg - fiber ntau txoj kev thiab cov ribbon-fiber cables tshiab ntawm tib qhov kev faib tawm.

8. Qhov ntau thiab tsawg cable haum rau GL-5601?

Cov chaw nres nkoj cable txais cov cables nrog lub tsho sab nraud ntawm Φ8 mm txog Φ18 mm. Qhov no suav nrog ntau tshaj FTTH faib cable qhov ntau thiab tsawg (8-12mm), aerial self-txhawb cables, thiab txheem xoob- raj qaum qaum cables. Rau cov kab hluav taws xob sab nraud qhov ntau ntawm no - cov kab xaim tiaj tus, cov hlua khi, lossis cov kab hlau loj loj tshaj 20mm - cov khoom siv chaw nres nkoj muaj; suav nrog cable spec hauv koj qhov kev nug.

9. Qhov kev txiav txim yam tsawg kawg nkaus yog dab tsi thiab kuv tuaj yeem tau txais cov qauv dawb?

Standard MOQ yog 50 units rau kev txiav txim ntau lawm. Cov qauv pub dawb muaj rau kev ntsuam xyuas - feem ntau 1-2 units xa hauv 3-5 hnub ua haujlwm. Lub sij hawm ua cov hmoov txhuas yog 10 hnub ua haujlwm rau kev teeb tsa tus qauv; Kev cai OEM / ODM xaj yuav xav tau cov cuab yeej siv sijhawm ntxiv. Tiv tauj peb nrog koj qhov project spec thiab peb yuav paub meej tias muaj thiab lub sijhawm ua haujlwm ncaj qha.


gloryoptic
Peb Kev cog lus zoo

Comprehensive 3-xyoo Warranty

Peb ntseeg siab rov qab tag nrho peb cov khoom nrog a3 xyoo warranty. Peb txoj cai tshwj xeeb rau kev pabcuam yog: nyob rau hauv ib xyoos rau cov teeb meem zoo, peb muaj lub luag haujlwm tag nrho rau kev xa rov qab; hauv ob xyoos, rau kev hloov pauv; thiab nyob rau hauv peb xyoos, rau kev kho.

Clear & Sib tw MOQ

Peb txais tos ob qho tib si mus sib hais thiab ntau xaj. Peb tus qauvYam tsawg kawg nkaus Order Quantity (MOQ) yog 50 units. Peb kuj muabcov qauv dawb rau kev kuajlos pab koj ntsuas peb qhov zoo nrog kev ntseeg siab.

Fast & Reliable Logistics

Peb lav kev xa khoomhauv 10 hnubrau cov khoom txheem. Peb qhov txiaj ntsig logistics suav nrogtus nqi- qhov rooj zoo- mus rau - qhov rooj pabcuamkom yooj yim shipping rau koj.

Peb lub Foundation

Rov qab los ntawm18 xyoo ntawm kev paubtxij li xyoo 2008, peb tswj tau zoo los ntawm peb lub Hoobkas, txaisOEM/ODMthov, thiab tswjnpaj khoomrau wholesale. Peb tsom mus rau kev xa qhov zoo tshaj plaws tshuav ntawmnqe thiab zooncaj qha raucov neeg siv khoom kawgthoob ntiaj teb.

 

Koj qhov kev ntseeg siab yog peb qhov tseem ceeb. Koom tes nrog peb rau kev txhawb nqa fiber ntau optic daws kev txhawb nqa los ntawm kev cog lus meej.

Cim npe nrov: Tuam Tshoj dome fiber ntau optic splice kaw, Tuam Tshoj dome fiber optic splice kaw manufacturers, lwm tus neeg, Hoobkas

Xa kev nug