Configuration Snapshot
| Khoom npe | FTT-B08 IP68 Gel-Sealed Fiber Optic Distribution Box |
|---|---|
| Network Role | Sab nraum zoov FTTH nkag davhlau ya nyob twg rau branching, splice cia, PLC splitter loading thiab poob cable handoff |
| Qhov zoo tshaj plaws -Fit Project | Txoj kev nyob hauv tsev, cov ncej faib cov neeg nyob deb nroog, MDU cov phab ntsa sab nrauv, cov ntsiab lus nkag hauv tsev kawm ntawv thiab strand -cov neeg koom nrog cov ceg ntoo |
| Core Advantage | Siab dua splice cia thiab 8- tso zis muaj peev xwm nyob rau hauv ib puag ncig huab cua-sealed |
| Ua kom pom tseeb | Paub meej tias cable OD, phua piv, adapter tso zis txoj kev npaj, mounting cov khoom thiab ntim yuav tsum tau ua ntej xaj |
Qhov twg Lub thawv no haum rau hauv FTTH Tsim
FTT-B08 yog nyob ze ntawm ntug ntawm qhov kev faib khoom siv kho qhov muag tsis pom kev, ze rau cov neeg siv khoom poob. Nyob rau hauv ib tug raug xa mus, cov khoom siv cable yog tsau thiab kaw ntawm qhov chaw nkag, fibers yog spliced los yog xa mus rau thaj tsam splitter, thiab yim lub xaim xaim xaim txuas mus rau cov neeg siv kawg.
Qhov no ua rau cov khoom tsim nyog rau kev nkag mus rau cov ntsiab lus uas cov kws tshaj lij xav tau ib thaj tsam ntawm lub cev ntawm cov khoom noj khoom haus / kev faib khoom cable tswj thiab poob - cov neeg ua haujlwm sab. Lub kaw lus tuaj yeem txhawb nqa phab ntsa, ncej lossis strand installation, muab cov phiaj xwm kev ywj pheej ntau dua thaum xaiv qhov chaw mounting sab nraum zoov.

Qhib pem hauv ntej saib uas qhia cov zis thiab cable tswj cheeb tsam.

Internal layout siv rau splicing, splitter thiab routing zones.
FTT-B08 Technical Data
| Yam khoom | Distribution Box |
|---|---|
| Khoom Series | FTT-B08 |
| Khoom Dimensions | 339 × 194 × 128 hli |
| Khoom siv tsev | PP + GF |
| IP Qib | IP68 |
| Ua haujlwm kub | -25℃~ +65 degree |
| Splicing Peev xwm | 72 cev, |
| Splitter Ratio | 1 × 1: 8 lossis 2 × 1: 4 |
| Cable nkag Ports | 4 daim, φ11 mm lossis φ15 mm |
| Poob Cable Capacity | 8 hli, f5mm |
| Tau tshaj Cable Diameter | φ3mm ~ φ15mm |
| Hom kev sib khi | Mechanical foob, gel sealing |
| Xim | Dub |
| Mounting | Phab ntsa / Ncej / Strand |
Dimension Drawing thiab Housing Layout
Qhov kev kos duab no muab kev pom pom rau FTT-B08 vaj tse profile, pem hauv ntej layout, sab saib thiab sab hauv npog qauv. Nws yog ib qho tseem ceeb thaum kuaj xyuas qhov chaw muaj phab ntsa, ncej clearance, cable routing kev taw qhia thiab project drawing coordination ua ntej installation.
Dimension reference for FTT-B08 enclosure structure, cover clearance and mounting layout.
Dab tsi ua rau FTT-B08 txawv ntawm cov thawv me me?
8-Top Access Peev Xwm
Yim φ5 mm poob txoj haujlwm ua rau lub thawv tsim nyog rau txoj kev - sab lossis lub tsev - sab faib ntau dua li cov 4-tej terminals.
72-Core Splice Reserve
Qhov loj dua sab hauv splice nyiaj pab txhawb kev hloov pauv ntau dua thaum qhov project xav tau cov fiber ntau tshwj xeeb lossis ntau -core handoff.
Dual Splitter Planning
Cov npe 1 × 1: 8 lossis 2 × 1: 4 piv tso cai rau tib lub tswv yim vaj tsev los npog ib ceg 8-txoj kev lossis ob ceg 4-txoj kev ywj pheej.
IP68 Kev Tiv Thaiv Sab Nraud
Lub kaw lus yog npaj rau kev nkag mus rau sab nraum zoov qhov chaw uas muaj plua plav, dej raug thiab kev tiv thaiv cable nkag yog qhov tseem ceeb ntawm kev txhawj xeeb.
Wide Cable OD Ntau
Nrog φ3 mm rau φ15 mm cable compatibility, cov khoom yuav npaj rau ob peb feeder, ceg thiab poob cable ua ke.
Peb Mounting Xaiv
Phab ntsa, ncej thiab strand mounting xaiv pab tib tus qauv hloov mus rau lub tsev facades, aerial routes thiab roadside ODN qhov chaw.
Cable Path thiab Sealing Logic
FTT-B08 tsim yuav tsum tau nkag siab tias yog qhov chaw hloov chaw cable. Cov kab hluav taws xob nkag mus los ntawm cov chaw nres nkoj loj dua, raug tsau rau hauv lub thawv, thiab tom qab ntawd cov fibers raug xa mus rau thaj tsam splicing thiab splitter. Qhov poob sab siv yim txoj haujlwm tso tawm, pab txhim kho kom cov neeg siv khoom sib cais thiab yooj yim dua los txheeb xyuas.
Mechanical gel sealing yog qhov tseem ceeb hauv cov thawv rau sab nraum zoov vim tias nws txhim kho kev sib khi ntawm cov khoom siv cable thaum tseem tso cai rau cov kws tshaj lij los qhib lub thawv rau kev teeb tsa lossis kev saib xyuas. Thaum lub sij hawm npaj qhov project, lub cable sab nraud txoj kab uas hla yuav tsum phim qhov chaw nres nkoj thiab sealing ntau yam.
| Thaj chaw | Tsim Lub Hom Phiaj | Tshawb xyuas teb |
|---|---|---|
| Nkag sab | Txais cov khoom noj loj dua lossis kev faib khoom siv cable | Kos φ11 mm lossis φ15 mm nkag yuav tsum tau |
| Splice tsam | Khaws thiab tiv thaiv fusion splice cov ntsiab lus | Khaws lub tes tsho tso kom huv si thiab tsis txhob hla cov fiber ntau |
| Splitter cheeb tsam | Txhawb 1 × 1: 8 lossis 2 × 1: 4 optical branching | Paub meej tias splitter layout ua ntej ntau lawm |
| Tso sab | Cais yim tus neeg siv khoom tawm cables | Sau cov kab poob thiab phim daim ntawv qhia chaw nres nkoj thaum lub sij hawm xa tawm |
Splice Tray, PLC thiab Adapter Routing Reference
Cov kev qhia sab hauv qhia tau hais tias yuav ua li cas feeder cable, kho cov tub ntxhais txuas ntxiv, splice trays, PLC splitter cheeb tsam, pigtails, adapters thiab tshav kub -shrink tes tsho yog teem rau hauv lub enclosure. Rau qhov kev txiav txim, qhov kawg routing yuav tsum tau lees paub raws li splitter ratio, adapter loading thiab cable hom.
Sab hauv fiber ntau txoj kev siv npog splice tais siv, PLC splice kev npaj, adapter loading thiab pigtail routing.
Cov ntawv thov pom zoo
Txoj Kev faib khoom nyob
Siv FTT-B08 ua qhov chaw nkag hauv zej zog uas muaj ntau lub tsev tau txais kev pab los ntawm ib lub thawv sab nraum zoov.
MDU Sab Nraum- Phab ntsa Handoff
Nruab ze ntawm ib lub tsev me me los yog lub tsev lag luam kom cais cov khoom noj fiber ntau los ntawm cov neeg siv khoom poob.
Rural Ncej-Mounted FTTH
Haum rau txoj kev dav hlau uas lub thawv nkag tau xav tau strand lossis ncej tso ze ze ntawm cov ceg ntoo.
Campus thiab Park Access Nodes
Siv tau rau sab nraum zoov passive fiber ntau faib ntawm cov tsev pabcuam, cov kev siv hluav taws xob thiab cov neeg siv qhov kawg.
Installation Workflow rau Field Teams
- Tshawb nrhiav qhov mounting point:xaiv phab ntsa, ncej lossis strand txoj hauj lwm thiab tawm ntawm qhov chaw ua haujlwm txaus nyob ib ncig ntawm lub qhov rooj.
- Match cable txoj kab uas hla:txheeb xyuas cov khoom siv cable OD thiab tso cable OD ua ntej txiav lossis npaj cov kab nkag nkag.
- Npaj cov khoom siv cable:sawb, txhim kho thiab txoj kev fibers mus rau hauv qhov chaw splice yam tsis muaj tshaj qhov khoov txwv.
- Load splitter configuration:nruab qhov kev npaj 1 × 1: 8 lossis 2 × 1: 4 splitter kev npaj raws li daim ntawv qhia chaw nres nkoj.
- Txoj kab uas hla:coj yim qhov tso zis cables los ntawm kev poob sab thiab khaws cov kab zauv rau kev saib xyuas.
- Kaw thiab ntaub ntawv:kaw lub hau, kaw qhov chaw nres nkoj, nqa cov duab thiab khaws cia raws li - ua daim ntawv qhia nrog cov ntaub ntawv qhov project.
Phab ntsa thiab ncej Mounting Reference
FTT-B08 tuaj yeem npaj rau phab ntsa-mounted lossis ncej-mounted sab nraum zoov FTTH nkag cov ntsiab lus. Kev txhim kho phab ntsa feem ntau yog siv cov ntsia hlau txuas ntxiv, thaum lub rooj teeb tsa ncej yuav siv cov hose clamps lossis qhov project- tshwj xeeb banding accessories.
Mounting siv rau phab ntsa installation thiab ncej installation.
Cov ntawv xaiv rau cov neeg yuav khoom
Ua ntej tshaj tawm RFQ, sib piv FTT-B08 nrog koj qhov loj ntawm ODN ceg. Nws yog qhov sib tw zoo dua thaum qhov project yuav tsum muaj yim qhov tso tawm, qhov loj dua splice cia lossis IP68 tiv thaiv sab nraum zoov. Yog tias qhov chaw nkag tau tsuas yog siv rau cov tsev me me xwb, lub thawv me me yuav raug nqi ntau dua.
| Lus nug | Vim Li Cas Nws Tseem Ceeb | Teb xav tau rau Quotation |
|---|---|---|
| Muaj pes tsawg tus neeg rau npe node yuav ua haujlwm? | Chaw nres nkoj suav txiav txim siab lub thawv loj thiab qhov sib cais sib piv. | 8 tee, los yog paub meej yog tias tsawg dua / ntau qhov tso tawm xav tau. |
| Qhov twg yuav tsum tau npaj splitter? | 1 × 1: 8 thiab 2 × 1: 4 txhawb kev sib txawv network layouts. | Ib ceg 8-txoj kev lossis ob ceg 4-txoj kev. |
| Dab tsi yog cable sab nraud txoj kab uas hla? | Sealing kev ua tau zoo nyob ntawm cable thiab chaw nres nkoj txuam. | Cov khoom xa tuaj OD thiab poob cable OD. |
| Nws yuav nruab qhov twg? | Mounting cov khoom siv thiab accessories sib txawv ntawm qhov chaw. | Phab ntsa, ncej lossis strand installation. |
| Dab tsi yuav tsum tau preloaded? | Factories yuav npaj splitter, adapter thiab pigtail xaiv txawv. | Splitter, adapter hom, pigtail ntev thiab daim ntawv lo yuav tsum tau. |
RFQ Daim Ntawv Teev Npe
Box Configuration
- Qauv: FTT-B08
- IP68 sab nraum zoov yuav tsum tau
- Phab ntsa, ncej lossis strand mounting
- Dub PP + GF vaj tsev
Optical Layout
- 1 × 1: 8 los yog 2 × 1: 4 splitter txoj kev npaj
- Adapter tso zis yuav tsum tau
- Pigtail / connector hom
- Chaw nres nkoj daim ntawv lo ua ntu zus
Paub meej txog qhov project
- Order kom muaj nuj nqis
- Lub teb chaws qhov chaw
- Ntim thov
- Lub sijhawm xa khoom
Ntim thiab Nyhav
| Sab hauv Carton Loj | 345 × 200 × 135 hli |
|---|---|
| Sab nrauv Carton Loj | 415 × 355 × 435 mm |
| Ntim Ntim | 6 PCS |
| Thawv hnyav | 15.50 KWG |
FAQ
Q: Dab tsi ntawm FTTH node yog FTT-B08 tsim rau?
A: Nws yog tsim los rau sab nraum zoov 8-poob nkag qhov chaw uas ib tug enclosure yuav tsum tau txais cov khoom xa tuaj cable sealing, splicing, xaiv splitter loading thiab cov neeg tso tawm tso tawm.
Q: Qhov kev tiv thaiv ntawm tus qauv no yog dab tsi?
A: Cov npe tiv thaiv qib rau FTT-B08 specification yog IP68.
Q: Muaj pes tsawg tus poob cables tuaj yeem txhawb nqa?
A: Cov lus qhia tshwj xeeb teev 8 txoj haujlwm poob rau φ5 mm poob cables.
Q: Dab tsi splitter configuration yog teev?
A: Cov kev xaiv sib piv yog 1 × 1: 8 lossis 2 × 1: 4.
Q: Lub peev xwm splicing yog dab tsi?
A: Cov npe bunchy splicing muaj peev xwm yog 72 cores.
Q: Nws puas tuaj yeem ntsia tau rau ntawm phab ntsa, ncej lossis strand?
A: Yog. Cov npe mounting xaiv yog phab ntsa, ncej thiab strand installation.
Q: Cov ntaub ntawv dab tsi yuav tsum tau lees paub ua ntej hais lus?
A: Paub meej cable sab nraud txoj kab uas hla, yuav tsum tau splitter configuration, adapter layout, mounting txoj kev, kom muaj nuj nqis, ntim thov thiab lub teb chaws lo lus uas peb.

Peb Kev cog lus zoo
Comprehensive 3-xyoo Warranty
Peb ntseeg siab rov qab tag nrho peb cov khoom nrog a3 xyoo warranty. Peb txoj cai tshwj xeeb rau kev pabcuam yog: hauv ib xyoos rau cov teeb meem zoo, peb muaj lub luag haujlwm tag nrho rau kev xa rov qab; hauv ob xyoos, rau kev hloov pauv; thiab nyob rau hauv peb xyoos, rau kev kho.
Clear & Sib tw MOQ
Peb txais tos ob qho tib si mus sib hais thiab ntau xaj. Peb tus qauvYam tsawg kawg nkaus Order Quantity (MOQ) yog 50 units. Peb kuj muabcov qauv dawb rau kev kuajlos pab koj ntsuas peb qhov zoo nrog kev ntseeg siab.
Fast & Reliable Logistics
Peb lav kev xa khoomhauv 10 hnubrau cov khoom txheem. Peb qhov txiaj ntsig logistics suav nrogtus nqi- qhov rooj zoo- mus rau - qhov rooj pabcuamkom yooj yim shipping rau koj.
Peb lub Foundation
Rov qab los ntawm18 xyoo ntawm kev paubtxij li xyoo 2008, peb tswj tau zoo los ntawm peb lub Hoobkas, txaisOEM / ODMthov, thiab tswjnpaj khoomrau wholesale. Peb tsom mus rau kev xa qhov zoo tshaj plaws tshuav ntawmnqe thiab zooncaj qha raukawg cov neeg siv khoomthoob ntiaj teb.
Koj qhov kev ntseeg siab yog peb qhov tseem ceeb. Koom tes nrog peb rau kev txhawb nqa fiber ntau optic daws kev txhawb nqa los ntawm kev cog lus meej.
Cim npe nrov: ftt-b08 ip68 gel- kaw fiber ntau optic tis lub thawv, Tuam Tshoj ftt-b08 ip68 gel- kaw fiber ntau optic tis lub thawv manufacturers, lwm tus neeg, Hoobkas