Poob Core Fiber Optic

Xa kev nug
Poob Core Fiber Optic
Paub meej
Yam khoom: Poob Core Fiber Optic
Qauv: FTTH Fiber Singlemode SST Flat Drop Core Fiber Optic 4.5x7mm Dielectric Gel -Dawb Rau Hardened Patch Cable
SST-Top dielectric cables muab kev yooj yim ntawm kev txhim kho tus qauv ALTOS cables nrog ib qho yooj yim, ib qho - raj tsim uas yooj yim rau kev nkag. Qhov no dielectric variant tshem tawm qhov xav tau ntawm kev sib txuas thiab hauv av. Cov kab hluav taws xob yog RDUP (RUS) tau teev tseg thiab muaj cov yam ntxwv zoo heev crush kuj. Muaj nyob rau hauv ua ntej -connectorized los ua ke, nws yog ib qho kev xaiv zoo tshaj plaws rau poob daim ntawv thov.
Kev faib tawm yam khoom
FTTH kab
Share to
Hauj lwm lawm

Singlemode SST Flat Drop Core Fiber Optic 4.5x7mm yog tsim los rau kev siv tau zoo thiab txhim khu kev qha Fiber rau lub Tsev (FTTH) kev teeb tsa. Cov kab no sib txuas cov yam ntxwv tshiab nrog cov qauv tsim kom tau raws li qhov xav tau ntawm kev sib txuas lus siab niaj hnub no.
Lub luag haujlwm tseem ceeb ntawm Drop Core Fiber Optic no yog xa cov siab -kev ua tau zoo singlemode fiber optic txuas ncaj qha rau tsev lossis lag luam. Nws lub tiaj tus tsim thiab compact qhov ntev (4.5x7mm) ua rau nws zoo tagnrho rau kev teeb tsa hauv qhov chaw kaw, xws li raws phab ntsa lossis hauv pem teb. Lub singlemode fiber ua kom cov teeb liab zoo thiab muaj peev xwm bandwidth siab, txhawb siab - internet ceev, suab, thiab kev pabcuam video. Lub gel-kev tsim kho pub dawb ua kom yooj yim tuav thiab teeb tsa, txo cov kev ntxhov siab thiab teeb meem thaum teeb tsa.

product-800-800

Tso Core Fiber Optic Structures

Yam khoom

Kev piav qhia

Fiber suav

1-2

Tight tsis

OD (mm):

0.9±0.05

Khoom siv:

LSZH

Hauv Sheath

OD (mm):

2.0~3.0

Khoom siv:

LSZH

Cov tswv cuab muaj zog

Aramid xov paj

Cov tswv cuab muaj zog

G-FRP-1.6 hli

Sheath

Thickness:

Tsis yog . 0.8mm

Khoom siv:

HDPE

OD ntawm cable (mm)

4.5 * 7.0 hli ± 0.3

Net nyhav (kg / km)

38

 

Optical Fiber

 

Yam khoom

UNITS

SPECIFICATION

Fiber hom

 

G652D

G657A

Attenuation

dB/km

1310nm Tsawg dua lossis sib npaug rau 0.36

1550nm Tsawg dua lossis sib npaug rau 0.22

Chromatic Dispersion

ps/nm.km

1310nm Tsawg dua lossis sib npaug li 3.5

1550nm Tsawg dua los yog sib npaug rau 18

1625nm Tsawg dua lossis sib npaug li 22

Zero Dispersion Slope

ps/nm2.km

Tsawg dua lossis sib npaug li 0.092

Zero Dispersion Wavelength

nm

1300 ~ 1324

Txiav-tawm Wavelength (lcc)

nm

Tsawg dua los yog sib npaug rau 1260

Attenuation vs. Khoov

(60 hli x 100 tig)

dB

(30 hli vojvoog, 100 nplhaib)

Tsawg dua lossis sib npaug li 0.1 @ 1625nm

(10 hli vojvoog, 1 nplhaib)

Tsawg dua los yog sib npaug rau 1.5 @ 1625nm

Hom Field Diameter

mm

9.2 ± 0.4 ntawm 1310nm

9.2 ± 0.4 ntawm 1310nm

Core-Clad Concentricity

mm

Tsawg dua los yog sib npaug li 0.5

Tsawg dua los yog sib npaug li 0.5

Cladding Txoj kab uas hla

mm

125±1

125±1

Cladding Non{0}}circularity

%

Tsawg dua los yog sib npaug li 0.8

Tsawg dua los yog sib npaug li 0.8

Txheej Dia

mm

245±5

245±5

Pov thawj Test

Gpa

Ntau dua lossis sib npaug rau 0.69

Ntau dua lossis sib npaug rau 0.69

 

Mechanical thiab Ib puag ncig kev ua tau zoo ntawm Kev Tso Tawm Core Fiber Optic

 

TSIS MUAJ.

Yam khoom

KEV TIV THAIV

ACCEPTANCE CRITERIA

1

Tensile Loading Test

Txoj Kev Xeem: IEC 60794-1-E1

- Ntev- tensile load: 350N

- Luv-tensile load: 800N

- Cable ntev: Ntau dua lossis sib npaug li 50m

- Attenuation increment@1550nm: Tsawg dua lossis sib npaug rau 0.1dB

- Tsis muaj lub tsho tawg thiab fiber ntau tawg

2

Crush Resistance Test

Txoj Kev Xeem: IEC 60794-1-E3

- Ntev load: 300 N / 100mm

- Luv load: 1000 N / 100mm

Lub sijhawm thauj khoom: 1 feeb

- Attenuation increment@1550nm: Tsawg dua lossis sib npaug rau 0.1dB

- Tsis muaj lub tsho tawg thiab fiber ntau tawg

3

Impact Resistance Test

Txoj Kev Xeem: IEC 60794-1-E4

- Qhov siab qhov siab: 1m

- Qhov hnyav: 450g

- Impact point: Ntau dua los yog sib npaug rau 5

- Impact zaus: Ntau dua lossis sib npaug rau 3/point

- Attenuation increment@1550nm: Tsawg dua lossis sib npaug rau 0.1dB

- Tsis muaj lub tsho tawg thiab fiber ntau tawg

4

Rov qab khoov

Txoj Kev Xeem: IEC 60794-1-E6

- Mandrel txoj kab uas hla: 20D (D=txoj kab uas hla)

- Qhov hnyav: 15kg

- Khoov zaus: 30 zaug

- Bending ceev: 2s/time

- Attenuation increment@1550nm: Tsawg dua lossis sib npaug rau 0.1dB

- Tsis muaj lub tsho tawg thiab fiber ntau tawg

5

Torsion Test

Txoj Kev Xeem: IEC 60794-1-E7

- Ntev: 1m

- Qhov hnyav: 25kg

- Lub kaum sab xis: ± 180 degree

- Zaus: Ntau dua lossis sib npaug rau 10/point

- Attenuation increment@1550nm: Tsawg dua lossis sib npaug rau 0.1dB

- Tsis muaj lub tsho tawg thiab fiber ntau tawg

6

Kev ntsuas dej nkag

Txoj Kev Xeem: IEC 60794-1-F5B

- Qhov siab ntawm lub taub hau: 1m

- Ntev: 3m

- Lub sij hawm xeem: 24 teev

- Tsis muaj dej los ntawm qhov qhib cable kawg

7

Kub Cycling Test

Txoj Kev Xeem: IEC 60794-1-F1

- Cov kauj ruam kub: + 20 degree, 40 degree, 70 degree, + 20 degree

- Lub Sijhawm Xeem: 24 teev / kauj ruam

- Cycle index:2

- Attenuation increment@1550nm: Tsawg dua lossis sib npaug rau 0.1dB

- Tsis muaj lub tsho tawg thiab fiber ntau tawg

8

Poob Performance

Txoj Kev Xeem: IEC 60794-1-E14

- Ntsuas qhov ntev: 30cm

-Qhov kub thiab txias: 70 ± 2 degree

- Lub Sijhawm Xeem: 24 teev

- Tsis muaj kev sib sau ua ke poob tawm

9

Kub

Kev khiav hauj lwm: -40℃~ +60 degree

Khw / Thauj: -50℃~ +70 degree

Kev teeb tsa: -20℃~ +60 degree

 

Nta

 

• Singlemode Fiber: Muab siab -ceev, siab -bandwidth txuas.
• Tso Core Fiber Optic Flat Design: Qhov ntev ntawm 4.5x7mm rau kev teeb tsa yooj yim hauv qhov chaw nruj.
• Dielectric Kev Tsim Kho: Tshem tawm qhov xav tau ntawm kev sib txuas thiab hauv av.

• Gel-Free: Yooj yim tuav thiab teeb tsa, txo kev ntxhov siab.
• Durable Sheath: Huab cua-resistant rau kev txhim khu kev qha hauv ntau qhov chaw.
• Ua ntej- Cov Kev Xaiv Txuas Txuas: Muaj rau kev xa tawm sai thiab yooj yim.
• Daim Ntawv Thov Ntau Yam: Haum rau ob qho tib si hauv tsev thiab kev lag luam FTTH kev teeb tsa.

Daim ntawv thov ntawm Drop Core Fiber Optic

 

• Chaw Nyob FTTH Installation: Zoo tagnrho rau kev sib txuas cov tsev mus rau siab -fiber networks ceev, ua tsaug rau nws compact tsim thiab yooj yim installation.
• Kev Siv Ua Lag Luam: Haum rau me me mus rau nruab nrab - qhov chaw ua lag luam loj uas yuav tsum tau muaj kev sib txuas fiber ntau.
• Kev Txhim Kho Ntau Yam: Lub tiaj tus, gel- tsim qauv pub dawb tso cai rau kev txhim kho yooj yim hauv ntau qhov xwm txheej, suav nrog kev txuas ntawm cov chaw lossis kev sib txuas ntawm qhov chaw nruj. Nws txoj kev tsim kho ruaj khov ua kom ntseeg tau tias kev ua tau zoo nyob thoob plaws qhov chaw sib txawv thiab cov xwm txheej.

 

product-1075-418

 

Cim npe nrov: Tuam Tshoj poob core fiber ntau optic manufacturers, lwm tus neeg, Hoobkas

Xa kev nug