High-density Sub-unit Branch Multi Core Fiber Optic Cable

Xa kev nug
High-density Sub-unit Branch Multi Core Fiber Optic Cable
Paub meej
Lub GL-MCFC series txais kev sib cais sub-unit architecture. Txhua lub sub-unit muaj 12 xim-coded fibers ib TIA-598/IEC 60304, ua kom ncaj nraim hauv pem teb-theem branching yam tsis muaj kev cuam tshuam rau lub hauv paus pob txha khiav.
Fiber Hom: OM3 / OM4 / OM5 / Tib - hom (OS1 / OS2)
Core suav: 36/48/72/96
Sab nraud Dia: 13.8 - 28.2 mm
Outer Jacket: PVC / LSZH
Ua haujlwm kub: -30℃rau +80 degree
Tensile Force (ntev -lub sijhawm): 400 N
Kev faib tawm yam khoom
Sab hauv Fiber Optic Cables
Share to
Hauj lwm lawm

Glory Optical's GL-MCFC series high-density sub-unit branch multi-core fiber optic cable yog tsim los rau sab hauv tsev qaum teb thiab lub ntsiab riser faib hauv cov tsev lag luam loj, tsev kawm ntawv, thiab kev lag luam network. Nrog fiber ntau suav ntawm 36, 48, 72, thiab 96 cores koom ua ke rau hauv discrete 12-fiber sub-units, lub cable no txhawb nqa cov txheej txheem hauv pem teb- theem branching los ntawm ib leeg txha caj qaum khiav - txo qis kev siv cov kav dej thaum khaws cov fiber ntau suav tag nrho.

Xim coding ib TIA-598/IEC 60304 kom ntseeg tau tias txhua cov fiber ntau yog qhov tshwj xeeb txheeb xyuas tau ntawm txhua ceg lossis qhov chaw txiav, txo lub sijhawm thiab kev pheej hmoo cuam tshuam nrog kev sib tshuam thiab kev sau ntawv. Muaj nyob rau hauv OM3, OM4, thiab OM5 multimode variants rau bandwidth- sib txuas luv luv thiab nruab nrab, thiab hauv OS1/OS2 ib leeg- hom rau kev khiav haujlwm ntev dua, GL-MCFC series tuaj yeem teev meej meej kom phim cov kev xav tau ntawm txhua ntu.

PVC thiab LSZH tsho xaiv nyob rau hauv ob qho tib si qauv nyob rau hauv tsev cov cai thiab cov kev xav tau ntau tshaj ntawm plenum qhov chaw, huab cua- tuav zones, thiab pej xeem venues uas tsis tshua muaj pa emissions thiab halogen- pub dawb combustion.

product-800-800

Technical Specifications

Parameter Specification
Khoom qauv GL -MCFC Series (36 / 48 / 72 / 96 Core)
Hom Fiber OM3 / OM4 / OM5 Multimode|OS1 / OS2 Single-mode
Core suav 36 / 48 / 72 / 96 (kev cai muaj nyob ntawm kev thov)
Fibers Per Sub{0}}unit 12 (TIA-598 / IEC 60304 xim-coded)
Sub-unit Outer Diameter Kwv yees li . 3.0 hli
Sab nraud Diameter (OD) 13.8 hli (36-core) - 28.2 hli (96-core)
Outer Jacket Khoom PVC (tus qauv) / LSZH (tsawg pa luam yeeb xoom halogen)
Filling Khoom Tsis muaj
Ntev -Tensile Force 400 N
Luv -Tensile Force 1,300 N
Dynamic Khoov Radius (installation) Ntau dua lossis sib npaug li 15 × cable sab nraud
Static Khoov Radius (ntsia) Ntau tshaj lossis sib npaug rau 10 × cable sab nraud
Ua haujlwm kub -30℃rau +80 degree
Cia Kub -40℃rau +80 degree
Net nyhav 130 - 650 kg / km (nws txawv ntawm cov tub ntxhais suav)
Flammability (LSZH xaiv) IEC 60332-3-24, Qeb C ua raws
Smoke Emission (LSZH xaiv) Ua raws li IEC 61034

 

   

Daim ntawv thov Scenario

product-800-800
product-800-800
product-800-800
  1. Enterprise Building Backbone Distribution.Hauv cov tuam tsev ua lag luam loj, GL-MCFC series muab qhov siab -cov pob txha txuas ntawm cov khoom siv tseem ceeb (MER) thiab chav sib txuas lus (TRs) ntawm txhua lub tsev. Lub sub-unit ceg qauv tso cai rau lub hom phiaj sub-units mus rau hauv pem teb- theem thaj vaj huam sib luag yam tsis muaj kev cuam tshuam cov pob txha ntxiv - txo qis lub sijhawm teeb tsa thiab tshem tawm qhov yuav tsum tau rov qab - nkag lossis rov- txiav ib feem ntawm txoj kab tsis muaj kev cuam tshuam.
  2. Data Center Inter-Floor thiab High-Density Zone Cabling.Rau intra- tsim cov ntaub ntawv chaw ib puag ncig uas suav fiber ntau thiab kev sib koom ua ke tsis yog- sib tham tau, GL-MCFC series muab OM3/OM4/OM5 multimode kev txhawb nqa rau kev koom ua ke ncaj qha nrog 10G, 25G, 40G, thiab 100G cov khoom siv nquag. Lub compact sub-unit profile minimizes hneev taw nyob rau hauv congested cable tais thiab riser shafts, ua kom txoj kev nkag mus rau yav tom ntej ntxiv.
  3. Tsev kawm ntawv thiab Multi-Segment Network Infrastructure.Rau kev xa tawm hauv tsev kawm ntawv xav tau kev sib txuas ntawm fiber ntau hla ntau pem teb, tis, lossis cov tsev nyob ib sab, ib qho - hom (OS1/OS2) kev teeb tsa ntawm GL- MCFC series txhawb kev sib kis tau zoo tshaj qhov ncav cuag ntawm multimode fiber ntau, thaum lub sub zoo tib yam sub-unit ceg txheem txheej txheem tswj txhua qhov chaw.

Nta

Covsub-unit ceg architectureyog tus yam ntxwv txhais ntawm GL-MCFC series. Txhua lub xov tooj muaj ntau qhov sib cais sub-units, txhua lub vaj tse raws nraim 12 xim-coded fibers hauv ib lub raj nyias nyias nyias. Lub koom haum sab hauv no tso cai rau tus neeg teeb tsa tshem tawm thiab xa ib qho sub-unit mus rau hauv pem teb- theem faib vaj huam sib luag thaum cov seem sub-unit tseem tsis muaj kev cuam tshuam raws li txoj hauv kev tseem ceeb hauv qab. Qhov tshwm sim yog ntsuas qhov txo qis hauv kev teeb tsa tsis yooj yim thiab cov npoo qis dua rau qhov yuam kev thaum ua haujlwm nrog cov fiber ntau suav hauv congested riser shafts.

Multimode thiab ib zaug -mode versatilityUa kom ntseeg tau tias GL-MCFC series tuaj yeem raug teev kom haum raws li qhov yuav tsum tau muaj kev sib kis ntawm ib qho chaw sab hauv tsev. OM3 xa 10G txuas mus txog 300 m; OM4 txuas ntxiv mus txog 550 m thiab txhim kho 40G / 100G kev ua haujlwm; OM5 (wideband multimode) txhawb nqa luv wavelength division multiplexing (SWDM) rau 100G thiab tshaj siv ib khub fiber ntau. OS1/OS2 ib leeg- cov kev xaiv hom muab cov pob txha tsis muaj kev txwv tsis pub muaj txiaj ntsig rau kev xa tawm hauv tsev kawm ntawv loj, tag nrho nyob rau hauv tib lub sub-kab ceg cable hom.

Hluav taws kub- txoj kev xaiv lub tsho ua rawsnyob rau tag nrho cov ntau yam ntawm sab hauv installation ib puag ncig. Tus qauvPVC tshoua tau raws li cov cai hauv tsev uas yuav tsum tau ua thiab yog tus nqi -kev xaiv zoo rau feem ntau cov ntawv thov kev lag luam riser. CovLSZH tsho- tau lees paub rau IEC 60332-3-24 (Cat. C) rau kev txwv cov nplaim hluav taws thiab IEC 61034 rau cov pa luam yeeb tsawg - yog qhov kev xaiv pom zoo rau cov chaw plenum, chav server, tunnels, tsheb thauj mus los hubs, thiab txhua qhov chaw uas muaj cov pa phem halogenic gascombustion los yog cov neeg ua haujlwm hnyav kawg.

Robust mechanical kev ua tau zoounderpins lub cable txoj kev ntseeg tau thaum lub sij hawm installation thiab ntev - kev pab cuam. Qhov ntsuas ntev - lub sij hawm tensile load ntawm400 Nthiab luv luv - lub sij hawm installation ncov ntawm1,300 Nua raws li qhov xav tau ntawm rub los ntawm cov kav dej ntev. Qhov tsawg kawg nkaus khoov vojvoog ntawm 10 × thiab dynamic yam tsawg kawg nkaus ntawm 15 × lub cable sab nraud tiv thaiv fiber ntau kev ncaj ncees thoob plaws hauv txheej txheem installation thiab dhau lub neej ntawm qhov txuas.

Qhov chaw- ua haujlwm siab - ntom ntom profilekhaws cov kab sab nraud nyob rau hauv thaj tsam ntawm 13.8 mm (36-}core) txog 28.2 mm (96-}core), xa cov fiber ntau suav rau hauv cov ntoo khaub lig compact-section uas ua rau siv tau zoo ntawm cable tais thiab qhov chaw conduit. Rau cov haujlwm uas xav tau fiber ntau suav dhau 96 cores, tsis yog tus qauv sub-unit configurations, tshwj xeeb lub tsho formulations, los yog kev cai branding, Glory Optical'sKev pab cuam OEM / ODMtxhawb nqa kev tsim qauv zoo nrog kev sib tham txog engineering thiab kev lees paub zoo.

 

Lus nug & Lus teb

Q1: Dab tsi yog qhov sib txawv ntawm kev sib kis ntawm OM3, OM4, thiab OM5?

A: OM3 txhawb 10G txog 300 m thiab 40G / 100G txog 100 m. OM4 txuas 10G mus txog 550 m thiab 40G / 100G txog 150 m. OM5 (wideband multimode) tau ua kom zoo rau SWDM hla plaub lub wavelengths - ua kom 100G kis tau tus mob ib khub fiber ntau ntawm qhov deb mus txog 150 m - ua rau nws yog qhov kev xaiv zoo tshaj plaws rau siab - ceev cov ntaub ntawv chaw ib puag ncig kev npaj rau kev loj hlob network. Rau cov caj qaum ntu uas dhau qhov kev txwv ntau hom kev ncua deb, OS1/OS2 ib leeg - hom kev xaiv muab qhov tseem ceeb uas tsis muaj kev txwv.

Q2: Cov tub ntxhais suav lossis sub-cov kev teeb tsa tuaj yeem hloov kho dua li cov qauv kev xaiv?

A: Yog. Standard configurations npog 36, 48, 72, thiab 96 cores nyob rau hauv 12-fiber sub-unit increments. Kev suav cov tseem ceeb, lwm cov sub- suav cov fiber ntau, cov xim tsis zoo li lub tsho, thiab cov khoom ntim khoom muaj npe muaj nyob hauv Glory Optical's OEM / ODM program. Yam tsawg kawg nkaus txiav txim kom muaj nuj nqis thiab engineering tshuaj xyuas ncua sij hawm siv; thov hu rau peb pab neeg muag khoom rau kev hais lus thiab kev sib tham.

Q3: Dab tsi yog qhov tseeb kev teeb tsa thiab qhov ntsuas hluav taws xob zoo li qub rau txhua qhov sib txawv?

A: Lub dynamic (thaum lub sij hawm installation) yam tsawg kawg nkaus khoov vojvoog yog 15 npaug ntawm cov kab hluav taws xob sab nraud; qhov zoo li qub (ntawm -so) yam tsawg kawg nkaus yog 10 npaug ntawm txoj kab uas hla. Rau 36-core variant (OD ≈ 13.8 mm), qhov tsawg kawg nkaus zoo li qub yog kwv yees li 138 mm. Rau 96-core variant (OD ≈ 28.2 mm), nws yog kwv yees li 282 mm. Ua txhaum cov kev txwv no yuav ua rau muaj kev cuam tshuam ntau ntxiv, micro-khoov teeb liab poob, thiab muaj peev xwm tawg fiber ntau hauv sub-unit.

Q4: Puas yog qhov cable no siv tau nrog MTP / MPO connector systems rau ntsaws -thiab-play deployment?

A: Yog. Tus kheej sub-cov chav nyob tau ua tiav nrog LC, SC, thiab MTP / MPO kev txiav tawm ntawm ob qho kawg. Glory Optical tuaj yeem muab cov rooj sib tham ua ntej- txiav tawm nrog MTP / MPO lub cev sib txuas rau cov ntsaws ncaj qha- thiab - ua si kev koom ua ke nrog patching cassettes thiab thaj vaj huam sib luag, tshem tawm qhov xav tau ntawm thaj chaw splicing thiab ua kom lub sijhawm ua haujlwm nrawm hauv cov ntaub ntawv chaw lossis cov phiaj xwm cabling.

Q5: Nyob rau hauv qhov chaw teeb tsa twg yog LSZH lub tsho yuav tsum tsis yog tsuas yog pom zoo?

A: LSZH feem ntau raug tso cai los ntawm cov cai hauv zos thiab cov qauv (xws li EN 50575 CPR Class Dca lossis siab dua hauv Tebchaws Europe) thaum twg cable raug teeb tsa hauv qhov chaw kaw lossis qhov cua tsis zoo - suav nrog tsa- chav server hauv pem teb, plenum ceilings, HVAC huab cua- chaw nres tsheb hauv av, chaw nres tsheb hauv av, chaw nres tsheb multi-cov tsev nyob. Hauv kev tshwm sim hluav taws kub, LSZH cov ntaub ntawv tsim cov pa luam yeeb tsawg thiab xoom halogenic acid gas, txhim kho cov neeg nyob hauv kev nyab xeeb thiab txwv kev puas tsuaj rau cov khoom siv hluav taws xob uas nyob ib sab.


gloryoptic

Peb Kev cog lus zoo

Comprehensive 3-xyoo Warranty

Peb ntseeg siab rov qab tag nrho peb cov khoom nrog a3 xyoo warranty. Peb txoj cai tshwj xeeb rau kev pabcuam yog: hauv ib xyoos rau cov teeb meem zoo, peb muaj lub luag haujlwm tag nrho rau kev xa rov qab; hauv ob xyoos, rau kev hloov pauv; thiab nyob rau hauv peb xyoos, rau kev kho.

Clear & Sib tw MOQ

Peb txais tos ob qho tib si mus sib hais thiab ntau xaj. Peb tus qauvYam tsawg kawg nkaus Order Quantity (MOQ) yog 50 units. Peb kuj muabcov qauv dawb rau kev kuajlos pab koj ntsuas peb qhov zoo nrog kev ntseeg siab.

Fast & Reliable Logistics

Peb lav kev xa khoomhauv 10 hnubrau cov khoom txheem. Peb qhov txiaj ntsig logistics suav nrogtus nqi- qhov rooj zoo- mus rau - qhov rooj pabcuamkom yooj yim shipping rau koj.

Peb lub Foundation

Rov qab los ntawm18 xyoo ntawm kev paubtxij li xyoo 2008, peb tswj tau zoo los ntawm peb lub Hoobkas, txaisOEM / ODMthov, thiab tswjnpaj khoomrau wholesale. Peb tsom mus rau kev xa qhov zoo tshaj plaws tshuav ntawmnqe thiab zooncaj qha raukawg cov neeg siv khoomthoob ntiaj teb.

 

Koj qhov kev ntseeg siab yog peb qhov tseem ceeb. Koom tes nrog peb rau kev txhawb nqa fiber ntau optic daws kev txhawb nqa los ntawm kev cog lus meej.

Cim npe nrov: high-density sub-unit ceg multi core fiber optic cable, Tuam Tshoj siab-density sub-unit ceg multi core fiber optic cable manufacturers, lwm tus neeg, Hoobkas

Xa kev nug