Engineered rau Extreme Reliability. Ua rau Niaj hnub nimno Networks
Glory Optic covOM4 Fiber Patch Cableyog lub laser -optimized multimode fiber ntau (LOMMF) sib dhos ua rau cov teeb liab xav tau ib puag ncig hauv cov chaw zov me nyuam niaj hnub, chav xov tooj, thiab chaw cia khoom sib txuas. Featuring ib50/125 µm qib -index corethiab qhov tseeb - hauv avzirconia ceramic ferrule, txhua qhov xaim xaim xaim poob qis dua 0.2 dB thiab rov qab poob ntau dua 26 dB (UPC) - txheeb xyuas los ntawm 100% Hoobkas kawg- ntsej muag tshuaj xyuas thiab IL / RL kuaj ua ntej xa khoom.
CovDuplex LC / UPC-SC / UPCconfiguration ua raws li TIA-568.3-DA- rau-B polarity, ua rau nws poob- haum rau kev sib txuas SFP+ thiab QSFP+ transceivers, thaj vaj huam sib luag, thiab cov hloov kho qhov muag hauv 10GBase-SR, 40GBs thiab 10GBase-10GBase-SR Covmagenta LSZH tsho(IEC 60332-1 kev ua raws cai) tsim nyob ze - xoom pa luam yeeb thiab tsis muaj roj halogen hauv hluav taws kub - ua tau raws li qhov nruj tshaj plaws hauv tsev kev nyab xeeb kev ntsuas rau plenum thiab riser txoj kev.
Tsis zoo li cov khoom siv cables muag ntawm specs ib leeg, Glory Optic cables yog tsim nrogkhoov- fiber ntau insensitive (7.5 hli yam tsawg kawg khoov vojvoog), ib qho tseem ceeb sib txawv uas txo cov teeb liab poob thaum lub sij hawm nruj routing nyob rau hauv ntom 1U thiab 2U thaj panels. Customized ntev los ntawm 0.5 m mus rau 100 m yog muaj nyob rau hauv txhuas lub sij hawm luv luv li 5 hnub ua hauj lwm, nrog rau OEM tsho xim, daim ntawv lo, thiab connector hom kev xaiv kom tau raws li ib tug project specification.

Vim li cas thiaj xaiv Armored LC Fiber Patch Cable?

LOMMF 50/125 µm + ceramic ferrule
Qib -index OM4 fiber core optimized rau 850 nm VCSEL lasers. Zirconia ceramic ferrule av rau PC / UPC tiav. Magenta LSZH tsho, 2.0 hli OD, duplex zipcord. Kev khiav hauj lwm ntau -20℃rau +70℃. Muaj simplex lossis duplex; SC, LC, FC, ST, MU, MTRJ connectors; PVC lossis LSZH tsho; Riser (OFNR) lossis Plenum (OFNP) kev ntsuas.
Khoov-insensitive + 100% kawg-lub ntsej muag kuaj
7.5 hli yam tsawg kawg nkaus khoov vojvoog tiv thaiv nruj txee routing yam tsis muaj teeb liab degradation. Txhua lub xov tooj tau txais IL, RL, thiab 3D interferometer kawg - ntsej muag tshuaj xyuas - tsis zoo li cov neeg muag khoom siv nyiaj uas batch - sim nkaus xwb. Factory- kaw khau raj tiv thaiv kev sib kis thaum lub sij hawm xa khoom, qhov ua rau ntawm qhov txuas tsis ua haujlwm thaum tuaj txog.


Zero rework nqi, ceev commissioning
Ua ntej- kuaj kab hluav taws xob tshem tawm ntawm- qhov chaw OTDR pov thawj rau feem ntau cov kev teeb tsa, txiav kev ua haujlwm siab txog li 40%. Magenta tsho xim tam sim qhov txawv ntawm OM4 los ntawm OM3 (aqua) nyob rau hauv ib puag ncig sib xyaw, txo cov tib neeg cable-swap yuam kev - cov ntaub ntawv mob taw tes nyob rau hauv loj - teev cov ntaub ntawv chaw migrations.
IEC / TIA tau ntawv pov thawj · ROHS raws
Tsim los rau TIA-492AAAD (OM4), IEC 60793-2-10, thiab ANSI/TIA-568.3-D. ROHS raws, LSZH IEC 60332-1 hluav taws-kuaj. Modal bandwidth 4,700 MHz ·km ntawm 850 nm - 2 × OM3. Kuaj raws ANSI/TIA/EIA-455-171-A attenuation standard. Muab tso rau hauv hyperscale cov ntaub ntawv chaw, chaw lag luam nyiaj txiag, thiab tsev kawm ntawv SAN nraub qaum thoob plaws 40+ lub teb chaws.

Tsim los rau cov ntawv thov tseem ceeb
Data Centers
High -kev sib txuas LC
TSO / EoR architecture
Cable congestion ib puag ncig
Industrial Networks
Factory automation
Fais fab substations
Cov khoom siv roj & roj
FTTx & Telecom
Sab nraum zoov txee
Central chaw ua haujlwm
Muab cov kab hloov pauv
Infrastructure Projects
Rail transit systems
Underground conduits
Kev tiv thaiv- qib kev xa tawm
Technical Specifications
Cable & connector
| Fiber hom | OM4 LOMMF 50/125 µm |
| Modal bandwidth | 4,700 MHz · km @ 850 nm |
| Connector xaiv | LC / SC / FC / ST / MU / MTRJ |
| Polish hom | PC / UPC / APC |
| Cov khoom siv Ferrule | Zirconia ceramic, 1.25 hli (LC) |
| Cable OD | 2.0 hli duplex zipcord |
| Jacket khoom | LSZH (std.) / PVC yeem |
| Jacket ntsuam xyuas | Riser OFNR / Plenum OFNP |
| Jacket xim | Magenta (OM4 std.) / kev cai |
| Min. khoov vojvoog | 7.5 hli (khoov-insensitive) |
Optical kev ua tau zoo
| Insertion poob (max.) | Tsawg dua lossis sib npaug rau 0.2 dB (lub Hoobkas- kuaj) |
| Rov qab poob UPC (min.) | Ntau dua lossis sib npaug li 26 dB |
| 10GBase-SR ncav cuag | 550 m |
| 40GBase-SR4 ncav cuag | 150 m |
| 100GBase-SR4 ncav cuag | 150 m (QSFP28) |
| 400G (BiDi SR) | 100 m |
| Ua haujlwm wavelength | 850 nm (VCSEL-zoo tshaj) |
| Ua haujlwm temp. | -20℃rau +70 degree |
| Cia temp. | -40℃rau +85 degree |
| Standard ntev xaiv | 0.5 / 1 / 2 / 3 / 5 / 10 m |
OM4 ncav cuag & ceev siv - paub ua ntej koj yuav
| Ceev / txheem | OM4 max ncav cuag | OM3 max ncav cuag |
| 1G - 1000Base-SX | 550 m | 550 m |
| 10G - 10GBase-SR | 550 m | 300 m |
| 25G - 25GBase-SR | 100 m | 70 m |
| 40G - 40GBase-SR4 | 150 m | 100 m |
| 100G - 100GBase-SR4 | 150 m | 100 m |
| 400G (BiDi SR) | 100 m | 30 m (limited) |
FAQ
Q: Qhov siab tshaj plaws ntawm OM4 fiber ntau ntawm 100G yog dab tsi?
A: OM4 multimode fiber txhawb 100GBase-SR4 (QSFP28 SR4 transceivers) ntawm qhov deb mus txog 150 meters. Rau 40GBase-SR4 nws kuj nce mus txog 150 m, thiab rau 10GBase-SR nws txuas mus rau 550 m. Yog tias koj khiav dhau 150 m ntawm 100G, xav txog OM5 (SWDM) lossis OS2 singlemode fiber ntau.
Q: Qhov txawv ntawm OM4 aqua thiab OM4 magenta yog dab tsi?
A: Ob leeg yog OM 4 50/125 µm fiber ntau nrog kev ua haujlwm zoo ib yam. Aqua (lub pas dej xiav) yog thawj TIA xim qauv sib koom nrog OM3, uas tuaj yeem ua rau tsis meej pem hauv qhov chaw sib xyaw. Magenta (erika violet / ntshav liab) tau qhia ua lwm yam OM4 tus cim - txhais los ntawm IEC - kom pom qhov txawv ntawm OM4 los ntawm OM3. Glory Optic muab ob qho tib si; magenta tau pom zoo rau kev xa tawm tshiab qhov twg OM3 kuj tseem muaj.
Q: Puas yog OM4 tau tshaj OM3 fiber ntau?
A: Yog, OM4 yog tag nrho rov qab sib xws nrog OM3. Txawm li cas los xij, thaum OM4 thiab OM3 cables sib xyaw ua ke hauv tib qhov txuas, qhov kev sib txuas tag nrho degrades rau OM3 specifications. Vim li no, nws yog qhov zoo tshaj plaws ua kom OM4 thiab OM3 ntu sib cais thiab xim -coded. Kev sib xyaw hom kev sib txuas (piv txwv li, LC rau SC) yog qhov zoo raws li ntev raws li ferrule polish hom (UPC / APC) zoo ib yam thaum kawg.
Q: OM4 thaj cables puas tuaj yeem txhawb 400G Ethernet?
A: OM4 tuaj yeem txhawb nqa 400G daim ntawv thov tab sis muaj tsawg kawg nkaus. Siv 400G-SR8 (8- txoj kab sib luag) transceivers hla MPO-12 lub rooj sib txoos, OM4 feem ntau npog txog 100 meters. Rau 400G ntawm 150 m lossis 800G xa tawm, OM5 nrog SWDM4 thev naus laus zis yog qhov kev xaiv zoo tshaj. Rau feem ntau cov chaw lag luam cov ntaub ntawv nyob qhov twg inter-rack khiav qis dua 100 m, OM4 tseem yog tus nqi-zoo 400G kev xaiv rau 3-5 xyoo tom ntej.
Q: LSZH txhais li cas thiab vim li cas nws tseem ceeb?
A: LSZH (Low Smoke Zero Halogen) txhais tau hais tias lub tsho cable tsim cov pa luam yeeb tsawg heev thiab tso tawm tsis muaj cov pa phem halogen thaum raug hluav taws. Hauv cov chaw kaw xws li cov chaw khaws ntaub ntawv, cov chav neeg rau zaub mov, thiab huab cua plenum - rov qab qhov chaw, LSZH yuav tsum tau xav tau lossis xav tau vim tias cov roj halogen los ntawm hluav taws kub PVC cables yog corrosive rau server hardware thiab txaus ntshai rau cov neeg ua haujlwm. Glory Optic's OM4 cables tau lees paub rau IEC 60332-1 LSZH tus qauv raws li lub neej ntawd, nrog PVC muaj nyob ntawm kev thov.
Q: Kuv puas yuav tsum xaiv OM4 lossis OS2 singlemode rau kuv qhov chaw khaws ntaub ntawv?
A: Xaiv OM4 yog tias: khiav qis dua 150 m, koj siv SR4 luv- ncav cuag transceivers (tus nqi qis dua), thiab koj cov peev nyiaj yog tus nqi-sensitive. Xaiv OS2 singlemode yog: khiav tshaj 300 m, koj xav tau yav tom ntej 400G / 800G + scalability yam tsis muaj recabling, lossis koj tab tom txuas cov tsev / tsev kawm ntawv. OM4 transceivers (SFP + SR) raug nqi ~ 60–70% tsawg dua qhov sib npaug singlemode (SFP + LR), ua OM4 tus yeej ROI rau ib txwm nyob hauv - tsim kev xa tawm.
Q: Lub Hwj Chim Optic puas tuaj yeem muab kev cai ntev thiab OEM daim ntawv lo?
A: Yog. Kev cai ntev ntawm 0.5 m txog 300 m yog muaj nrog 5-kev lag luam- hnub ua haujlwm rau cov qauv xaj. OEM kev xaiv muaj xws li kev cai lub tsho xim, laser-luam ntawv ntev, tus kheej hom khau raj luam ntawv, thiab kev cai ntim. MOQ rau tus qauv kev cai ntev yog feem ntau 50 pcs ib SKU. Hu rau peb pab neeg muag khoom rau qhov project quote.

Peb Kev cog lus zoo
Comprehensive 3-xyoo Warranty
Peb ntseeg siab rov qab tag nrho peb cov khoom nrog a3 xyoo warranty. Peb txoj cai tshwj xeeb rau kev pabcuam yog: nyob rau hauv ib xyoos rau cov teeb meem zoo, peb muaj lub luag haujlwm tag nrho rau kev xa rov qab; hauv ob xyoos, rau kev hloov pauv; thiab nyob rau hauv peb xyoos, rau kev kho.
Clear & Sib tw MOQ
Peb txais tos ob qho tib si mus sib hais thiab ntau xaj. Peb tus qauvYam tsawg kawg nkaus Order Quantity (MOQ) yog 50 units. Peb kuj muabcov qauv dawb rau kev kuajlos pab koj ntsuas peb qhov zoo nrog kev ntseeg siab.
Fast & Reliable Logistics
Peb lav kev xa khoomhauv 10 hnubrau cov khoom txheem. Peb qhov txiaj ntsig logistics suav nrogtus nqi- qhov rooj zoo- mus rau - qhov rooj pabcuamkom yooj yim shipping rau koj.
Peb lub Foundation
Rov qab los ntawm18 xyoo ntawm kev paubtxij li xyoo 2008, peb tswj tau zoo los ntawm peb lub Hoobkas, txaisOEM/ODMthov, thiab tswjnpaj khoomrau wholesale. Peb tsom mus rau kev xa qhov zoo tshaj plaws tshuav ntawmnqe thiab zooncaj qha raucov neeg siv khoom kawgthoob ntiaj teb.
Koj qhov kev ntseeg siab yog peb qhov tseem ceeb. Koom tes nrog peb rau kev txhawb nqa fiber ntau optic daws kev txhawb nqa los ntawm kev cog lus meej.
Cim npe nrov: Tuam Tshoj om4 fiber ntau thaj cable manufacturers, lwm tus neeg, Hoobkas