Ib qho FTTH nco cable feem ntau tuaj yeem kho tau tom qab kev puas tsuaj hauv lub cev, tab sis kev hloov pauv feem ntau yog qhov kev xaiv zoo dua thaum lub sijhawm luv luv, kev puas tsuaj txuas ntxiv mus dhau ib qho, lossis cov kab txuas ntxiv tsis tuaj yeem txhawb nqa thiab kaw kom raug.

paub meej tias qhov txhaum → nrhiav qhov chaw puas → xaiv kho lossis hloov → rov kho cov fiber ntau → tiv thaiv kev sib koom ua ke → txheeb xyuas qhov kev ua haujlwm kho qhov muag → tshem tawm qhov ua tsis tiav
Teb ceev:Tus neeg siv hluav taws xob hluav taws xob tsis tuaj yeem ua pov thawj tias qhov poob cable tawg. Paub meej tias qhov yuam kev ua ntej, tom qab ntawd siv txoj hauv kev tshuaj xyuas, kho qhov muag - lub zog kuaj xyuas, VFL lossis qhov tsim nyog OTDR los nrhiav qhov teeb meem. Xaiv cov kev hloov pauv tag nrho, ib qho kev sib txuas hauv ib cheeb tsam- kho qhov sib txuas, qhov kawg re- kev txiav tawm lossis kev hloov ua ntej- txiav tawm raws li qhov kev puas tsuaj, kev nkag mus, qhov seem cable thiab cov kev xav tau ntawm lub network.

ITU-T L.105 (11/2025) txhais cov kab hluav taws xob kho qhov muag raws li cov neeg siv khoom sib txuas rau lub network siv kho qhov muag thiab hais qhia tias cov yam ntxwv ntawm cable yuav tsum ua raws li cov xwm txheej ntawm qhov chaw teeb tsa tiag tiag. Nws Lub Yim Hli 2026 Corrigendum 1 ntxiv cov khoom siv npog kev laus, kev nkag mus rau hauv dej ntev, kev ya raws permeation, thiab nas thiab kab puas tsuaj. SaibITU-T L.105.

Ua ntej Kho: Paub meej tias qhov txhaum yog nyob rau hauv Drop Cable

Pib los ntawm kev sib cais ib qho kev ua haujlwm - cov khoom siv lossis cov teeb meem txuas los ntawm kev ua txhaum ntawm kev poob qis.

Hauv PON network, kev kuaj xyuas thawj zaug muaj txiaj ntsig tuaj yeem suav nrog ONT / ONU lub tswb lub xeev, tau txais lub hwj chim kho qhov muag, qhov chaw txuas, thiab muaj OLT / ONU cov ntaub ntawv kev ua haujlwm. ITU-T cov lus qhia tshwj xeeb rau PON systems suav nrog kev saib xyuas cov khoom siv kho qhov muag xws li kis tau thiab tau txais lub zog kho qhov muag, uas tuaj yeem pab txhawb kev sib cais ua ntej lub cable raug txiav lossis hloov.

Tshawb xyuas Qhov nws pab txiav txim
ONT/ONU xwm txheej thiab tswb Seb tus neeg siv khoom lub davhlau ya nyob twg tau poob qhov kev pabcuam kho qhov muag
Optical zog Txawm hais tias tau txais lub zog yog qhov txawv txav ntawm tus neeg teb xov tooj txwv
Connector tshuaj xyuas thiab tu Txawm hais tias muaj kab mob sib kis los yog kev puas tsuaj ntawm cov khoom txuas yog ua rau poob
Tso lub davhlau ya nyob twg / siv - ntsuas ntsuas Txawm hais tias qhov poob tsis zoo yog nyob rau ntawm tus neeg siv khoom sab lossis sab saud
Txoj kev tshuaj xyuas Seb puas muaj pov thawj ntawm kev puas tsuaj rau lub cev
VFL or OTDR Qhov twg qhov xav tias fiber ntau nyob

Kev hla- dhau ntawm PON lub ntsuas hluav taws xob kuj tseem tuaj yeem pab cais cov ntu ntu nruab nrab thiab qis ntawm PON nquag thaum tso cai rau OLT thiab ONT nyob hauv kev sib txuas lus. Saib EXFOsFTTx/PON testing reference.

Ceev faj thaum sim PON nyob nrog OTDR

Tus qauv tsim OTDR yuav tsum tsis txhob txuas nrog lub PON nquag.

Rau hauv -kev pab daws teeb meem, cov cuab yeej ntsuas thiab cov wavelengths yuav tsum sib haum nrog lub network nyob. Lim nyob -PON OTDR cov chaw nres nkoj feem ntau siv tawm- ntawm -band wavelengths xws li 1625 lossis 1650 nm kom cov teeb liab ntsuas tau sib cais los ntawm kev pabcuam wavelengths. Txoj kev tseeb nyob ntawm PON tiam, tsim network thiab tus neeg ua haujlwm txheej txheem. Saib EXFOshauv -kev pabcuam FTTH teeb meem sau tseg.

Live -kev ceeb toom hauv network:Tsis txhob kho qhov ib txwm muaj 1310/1550 nm OTDR test raws li cov txheej txheem ua ntej ntawm kev sib txuas ntawm cov neeg siv khoom. Paub meej tias cov fiber ntau yog qhov tsaus ntuj los yog nyob thiab ua raws li kev pom zoo network kev sim.

Fiber kev nyab xeeb los ua ntej kev soj ntsuam

Optical fais fab hauv kev sib txuas lus fiber ntau yuav pom tsis tau.

IEC 60825-2: 2021 muab cov kev cai nyab xeeb thiab kev taw qhia rau kev ua haujlwm thiab kev saib xyuas cov tshuab kev sib txuas lus fiber ntau. FOA ib yam nkaus qhia cov kws tshaj lij tsis txhob txiav txim seb puas muaj fiber ntau los ntawm kev saib mus rau qhov kawg ntawm nws; txheeb xyuas lub hwj chim kho qhov muag ua ntej lossis siv cov khoom siv tshuaj ntsuam xyuas kom tsim nyog. SaibIEC 60825-2: 2021 Kev Ua Haujlwm.

Nrhiav lub cev puas tsuaj

Siv txoj kev yooj yim tshaj plaws uas tuaj yeem teb qhov yuam kev - lo lus nug qhov chaw ntseeg tau.

Kev tshuaj xyuas txoj hauv kev → kho qhov muag- lub zog / kev kuaj txuas ntxiv → VFL qhov twg haum → OTDR thaum nyob deb - mus rau - cov ntaub ntawv xwm txheej xav tau

Pib nrog txoj kev cable

Tshawb xyuas cov seem uas siv tau rau:

  • txiav los ntawm kev ua vaj los yog cov cuab yeej tsim kho;
  • crushed los yog flattened tsho;
  • ntse kinks;
  • lub tsev puas lawm- cov ntsiab lus nkag;
  • cable rub tawm ntawm lub clamp;
  • tsis txhawb nqa dav hlau;
  • cuam ​​tshuam ducts los yog handhole txoj kev;
  • tsis ntev los no drilling, excavation los yog cable rub ze ntawm qhov poob.

Tsis txhob xav tias lub tsho uas pom tau tias puas ua rau tag nrho qhov cuam tshuam.

NTT tau tshaj tawm txog qhov kho qhov muag cable tsis ua haujlwm nyob rau hauv uas lwm lub cable tau teeb tsa los ntawm tib lub kav dej. Qhov kev poob qis tau pom qhov khoov hnyav thiab lub tsho sib cais; X-Ray tshuaj ntsuam xyuas pom tias ob lub fibers tawg. Kev soj ntsuam luam tawm pom tias kev puas tsuaj tsim los ntawm kev poob cable ua entwined nrog ib txoj hlua txuas thiab tom qab ntawd tensioned feem ntau zoo sib xws rau qhov chaw tsis ua hauj lwm. Saib covNTT Technical Review fault case.

Tswv yim siv:kev puas tsuaj fiber ntau tuaj yeem txuas ntxiv tshaj qhov pom tseeb sab nraud.

Siv VFL rau txoj kev luv luv thiab siv tau yooj yim

Lub teeb pom kev tsis pom kev tuaj yeem pab nrog txuas ntxiv, kev txheeb xyuas fiber ntau thiab nrhiav qee qhov kev so lossis khoov hnyav uas pom lub teeb liab tawm ntawm fiber ntau.

FOA tshwj xeeb txheeb xyuas VFLs uas muaj txiaj ntsig zoo rau kev nrhiav qhov yuam kev ze ntawm qhov kawg cable, suav nrog cov chaw uas OTDR cov chaw tuag tuaj yeem ua rau kev txhais lus nyuaj. Saib covFOA Visual Fault Locator phau ntawv qhia.

Tsis muaj txoj cai thoob ntiaj teb muaj txiaj ntsig xws li "ib txwm siv VFL hauv qab X meters thiab OTDR saum X meters." Qhov kev txiav txim siab nyob ntawm:

  • kev nkag mus tau yooj yim;
  • kev tsim kho kab;
  • nyob deb ntawm qhov xav tias qhov tshwm sim;
  • connector configuration;
  • seb lub network puas ua haujlwm;
  • kev daws teeb meem ntawm OTDR muaj.

Lub tsho sab nraum zoov opaque kuj tseem tuaj yeem tiv thaiv VFL lub teeb los ntawm kev pom. Qhov tsis pom lub teeb liab los ntawm lub tsho tsis ua pov thawj tias cov fiber ntau noj qab nyob zoo.

Glory tam sim nofiber ntau optic tool rangesuav nrog 650 nm VFL, kho qhov muag lub ntsuas hluav taws xob thiab tiaj tus -poob npaj cov cuab yeej rau FTTH teb ua haujlwm. Lawv yog cov cuab yeej cuam tshuam hauv kev daws teeb meem, tab sis kev xaiv cov cuab yeej yuav tsum ua raws li qhov ua txhaum thiab kev sib txuas hauv network es tsis yog cov khoom siv ruaj khov.

Siv OTDR thaum qhov chaw txhaum tsis paub meej

OTDR yuav muaj txiaj ntsig zoo dua thaum:

  • qhov poob yog faus los yog zais;
  • ob peb txoj hauv kev yog nkag tsis tau;
  • kev soj ntsuam pom pom tsis muaj kev puas tsuaj;
  • Qhov kev ncua deb mus rau qhov poob lossis kev cuam tshuam yog xav tau;
  • kev kho yuav tsum tau muab piv nrog cov kab dhau los.

Nco ntsoov tias OTDR qhiaoptical nrug raws cov fiber ntau, tsis yog qhov tseeb excavation coordinate. Khaws slack, txoj kev geometry thiab cable configuration yuav tsum tau txiav txim siab thaum txhais cov kab nyob deb mus rau hauv lub cev qhov chaw.

Qhov twg muaj cov kab hauv qab muaj, sib piv cov kab ua txhaum nrog cov ntaub ntawv teeb tsa thawj zaug es tsis txhob txhais cov kab tshiab hauv kev sib cais.

Kho lossis Hloov FTTH Drop Cable?

Cov lus nug tseem ceeb yog seb qhov kev kho qhov tshwm sim yuav yooj yim dua thiab txhim khu kev qha dua li hloov qhov cuam tshuam poob.

Plaub txoj kev kho dua tshiab npog feem ntau ntawm thaj chaw.

Txoj kev kho dua tshiab Tus neeg sib tw zoo tshaj Kev txwv loj
Ua kom tiav kev hloov pauv Kev khiav luv los yog siv tau; kev puas tsuaj loj; tsis raug cable uas twb muaj lawm Yuav tsum tau rerouting / rub tag nrho cov neeg siv khoom khiav
Nruab nrab -span fusion splice Ib qho chaw so ntawm txoj kev nyuaj lossis ntev Yuav tsum muaj kev noj qab haus huv txaus cable thiab tsim nyog tiv thaiv splice point
Re- xaus qhov kawg cable Kev puas tsuaj yog ze rau tus neeg siv khoom lossis lub davhlau ya nyob twg kawg Tsis daws kev puas tsuaj nyob deb ntawm kab
Hloov nrog ua ntej- txiav tawm Paub txoj kev thiab connector system; ntsaws-thiab- ua si architecture Length, connector interface thiab rub clearance yuav tsum yog

1. Hloov qhov poob tag

Kev hloov pauv tag nrho yog qhov kev xaiv huv dua thaum:

  • tus neeg ua haujlwm khiav yog luv thiab yooj yim rau kev nkag;
  • ob peb ntu tau raug tsoo los yog puas lawm;
  • cable zog cov tswv cuab tau raug cuam tshuam los ntawm ib cheeb tsam loj;
  • cov cable uas twb muaj lawm tsis haum rau ib puag ncig;
  • lwm splice yuav tsim ib tug neeg kho tshuab qhov chaw tsis zoo;
  • slack tsis txaus nyob rau kev kho kom raug.

Cov kab hloov pauv yuav tsum phim txoj hauv kev es tsis tsuas yog duplicate cov kab uas puas lawm.

Glory lubFTTH cable ntausuav nrog sab hauv tsev, sab nraum zoov, tiaj tus thiab tus kheej- txhawb nqa cov qauv siv G.657-series fibers rau cov neeg siv khoom siv.

2. Ua ib qho chaw fusion- kho qhov sib txuas

Ib nrab -span splice dhau los ua tus neeg sib tw muaj zog thaum:

  • kev puas tsuaj yog nyob rau hauv ib seem uas txheeb xyuas tau;
  • rov qab ua tiav qhov poob yuav cuam tshuam;
  • txaus noj qab haus huv cable tseem nyob rau ob sab;
  • cable zog cov tswv cuab tuaj yeem khaws tau zoo;
  • ib qho chaw uas tsim nyog tuaj yeem tiv thaiv seem rov qab los.

Kev kho hauv ib cheeb tsam yog ib qho kev nkag mus rau-kev ua haujlwm hauv network. Corning, piv txwv li, muaj kev kho mob fiber ntau kho kaw tshwj xeeb rau kev txuas ntxiv lossis kho cov kab hluav taws xob puas. Ib qho tam sim no ob- qauv fiber ntau txhawb nqa ob qhov sib txuas, 3.8–6.2 mm cable nkag, gel sealing thiab IP68 tsim. Saib covCorning drop repair kaw piv txwv.

Cov kev qhia tshwj xeeb no qhia txog vim li cas cov ntaub thaiv npog yuav tsum sib phim rau qhov tseeb cable. "Me me splice kaw" tsis yog ib qho kev piav qhia txog kev yuav khoom txaus.

3. Re- xaus nyob ze ntawm tus neeg siv khoom kawg

Yog tias qhov kev puas tsuaj ntawm cable raug kaw rau qhov kawg ntawm qhov kawg, txiav lub cable rov qab mus rau cov khoom noj qab haus huv thiab rov- txiav nws yuav zam qhov tsis tsim nyog nruab nrab - ncua kev sib koom ua ke.

Raws li kev pom zoo tsim network, qhov no yuav suav nrog:

  • fusion splicing rau pigtail;
  • txhim kho qhov pom zoo teb txuas;
  • re- txiav tawm hauv lub thawv txiav fiber ntau.

Ib lub teb txuas uas tsim los rau kev txiav tawm cov neeg siv yuav tsum tsis txhob siv los ua ib qho kev nthuav tawm sab nraum zoov nruab nrab - ncua kev kho.

Piv txwv li, Glory'sGL-FTB-4F termination boxmuab qhov kawg tiv thaiv rau fiber ntau txiav thiab khaws cia. Siv nws qhov twg lub network tsim hu rau qhov xaus; nws tsis yog ib qho kev hloov pauv rau qhov kev kho mob tshwj xeeb hauv kab kaw hauv nruab nrab ntawm txoj kev raug.

4. Hloov ib qho ua ntej- txiav tawm kev sib dhos

Nyob rau hauv ua ntej -connectorized FTTH architectures, hloov qhov kev sib dhos ua tiav tuaj yeem tshem tawm qee qhov kev sib tshuam.

Ua ntej siv txoj hauv kev no, txheeb xyuas:

  • txoj kev ntev;
  • hardened connector interface;
  • Terminal compatibility;
  • rub-qhov muag lossis qhov txuas- lub hnab ntawv tshem tawm;
  • khoov cov ntsiab lus raws txoj kev;
  • seb ib los yog ob qho kawg yuav tsum tau txuas.

Cov npe yeeb koobua ntej- txiav tawm fiber ntau optic cable sib dhosrau kev nkag mus rau- cov ntawv thov network, suav nrog kev teeb tsa cable thiab kev teeb tsa txuas.

Pom zoo Glory khoom rau txawv kho txoj kev

Txoj kev kho yuav txiav txim siab seb yam khoom twg yog nyob rau hauv cov khoom siv teb. Cov khoom lag luam hauv qab no tau sib phim rau peb qhov sib txawv ntawm kev kho kom zoo dua qub dua li nthuav tawm raws li kev hloov pauv hloov tau.

Glory Optical GJXFH GJXH indoor FTTH drop fiber cable

GJXFH / GJXH Sab Hauv Tsev Drop Fiber Cable

Siv txoj hauv kev no thaum cov neeg siv khoom puas raug hloov pauv zoo dua li spliced. Tus qauv Glory tau tshaj tawm yog lub tiaj tus kawg - mais kev poob cable rau kev nkag mus hauv tsev thiab kev sib txuas ncaj qha rau cov neeg siv khoom.

Qhov zoo tshaj plaws rau:ua kom tiav kev hloov ntawm luv luv lossis siv tau sab hauv FTTH poob.

Saib cov khoom

Glory Optical GL-FTB-4F 2 port fiber termination box

GL-FTB-4F 2-Port Fiber Termination Box

Cov neeg siv khoom sib cog lus-sab xaus taw tes rau kev sib txuas, fiber ntau cia thiab txiav tawm adapter. Nws haum rau txoj kev kho qhov kev puas tsuaj nyob ze ntawm qhov chaw lossis qhov kawg thiab lub cable tuaj yeem txiav rov qab rau cov khoom noj qab haus huv.

Qhov zoo tshaj plaws rau:endpoint re-kev txiav tawm es tsis yog ib qho kev nthuav tawm nruab nrab - ncua kev kho.

Saib cov khoom

Glory Optical Huawei Mini SC pre terminated FTTH drop cable

Huawei Mini SC Pre-Terminated Fiber Optic Cable

Lub Hoobkas- txiav tawm kev sib sau ua ke rau txoj hauv kev uas qhov ntev thiab qhov txuas txuas tau paub lawm. Nws tuaj yeem hloov qhov kev puas tsuaj yam tsis tau ntxiv ib qho tshiab splice thaum lub teeb tsa davhlau ya nyob twg tau tshaj.

Qhov zoo tshaj plaws rau:npaj ntsaws-thiab- ua si hloov pauv hauv qhov sib xws ua ntej- txuas FTTH architecture.

Saib cov khoom

Kev pom zoo ciam teb:cov khoom no pab kho txoj kev sib txawv. Paub meej tias kev tsim kho cable, connector interface, cable - nkag qhov ntev, txoj kev ntev thiab ib puag ncig kev teeb tsa ua ntej kho ib qho kev hloov pauv rau lwm tus.

Yuav Ua Li Cas Kho Ib Lub Zos Hauv Ib Lub Zos Cable Break

Thaum kho qhov chaw raug xaiv, lub hom phiaj yog los kho ob qho tib sioptical txoj kev thiab mechanical cable system.

Lub tsho tiag tiag- strip qhov ntev, lub zog- kev npaj cov tswv cuab, splice- txheej txheem tais thiab kev sib khi yog nyob ntawm cov lus qhia cable thiab kaw. Tsis txhob luam tawm qhov loj me los ntawm qhov tsis sib haum xeeb ntawm cable.

Kauj Ruam 1: Txhais qhov cuam tshuam

Paub meej tias cov kab hluav taws xob tau txheeb xyuas yog tus neeg siv khoom raug thiab tshuaj xyuas dhau qhov pom kev puas tsuaj.

Nrhiav:

  • elongated los yog distorted tsho;
  • puas muaj zog cov tswv cuab;
  • kinked seem;
  • tsoo cov cim;
  • pov thawj tias lub cable tau rub tom qab nws tawg.

Tshem tawm cov cable puas txaus uas ob qho tib si khaws cia yog cov suab nrov.

Kauj Ruam 2: Tsim kom txaus ua haujlwm ntev

Lub fusion splice tsis tuaj yeem ntsia tau ntseeg tau yog tias cov kab txuas ntxiv nyob hauv qhov nro.

Muab cable txaus rau:

  • kev npaj;
  • splicing;
  • kev tiv thaiv splice;
  • routing nyob rau hauv lub enclosure;
  • yav tom ntej rov- nkag mus rau qhov xav tau.

Yog tias qhov ntev ua haujlwm txaus tsis tuaj yeem tau txais yam tsis muaj kev ntxhov siab ntau dhau qhov kev poob qis, kev hloov pauv yuav yog qhov kev xaiv zoo dua.

Kauj Ruam 3: Npaj lub cable raws li nws qhov kev tsim kho

Pav ca FTTH nco cable, puag ncig poob cable thiab ntxiv dag zog sab nraum zoov tsis siv tib txoj kev npaj.

Tus kws kho mob yuav tsum txheeb xyuas:

  • tsho qauv;
  • cov tswv cuab muaj zog;
  • tsis/fiber qhov chaw;
  • tus xa xov los yog txhawb nqa, yog tias muaj;
  • qhov tseeb stripping cuab tam.

Tsis txhob cia rub lub load los ntawm lub cable los yog lub zog cov tswv cuab kom hloov ncaj qha mus rau lub liab qab fiber ntau los yog tiav splice.

Kauj ruam 4: Npaj thiab splice lub fiber

Rau fusion-splice kho:

  1. strip lub fiber txheej siv cov cuab yeej raug;
  2. ntxuav cov liab qab fiber ntau;
  3. tshem tawm ob qho tib si fiber ntau;
  4. ua lub fusion splice;
  5. tshuaj xyuas qhov tshwm sim splicer raws li tus neeg teb xov tooj tus txheej txheem;
  6. nruab ib lub splice tiv thaiv;
  7. muab qhov kev tiv thaiv splice tso rau hauv lub tais lossis tus tuav.

Qhov ntau tshaj plaws splice - tus lej poob yuav tsum tsis txhob siv rau txhua qhov kev kho FTTH. Qhov kev lees txais yuav tsum yog los ntawm tus tswv network, qhov project specification lossis cov phiaj xwm kev xeem.

Kauj ruam 5: Restore cable zog thiab strain nyem

Lub splice nws tus kheej yuav tsum tsis txhob nqa cable nro. Ruaj ntseg lub cable thiab nws cov tswv cuab lub zog siv lub kaw lus tuav tsim rau lub qhov rooj kaw. Xyuas tias ib txwm cable txav tsis tuaj yeem rub ncaj qha rau ntawm cov fiber ntau tiv thaiv.

Kauj Ruam 6: Hla lub fiber ntau thiab slack

Khaws cov khoom seem uas tsis muaj fiber ntau:

  • ntse tig;
  • pinching nyob rau hauv lub tais npog;
  • hla kev sealing nto;
  • nruj nruj;
  • cuam ​​tshuam nrog lwm cov splices.

Qhov tseeb khoov txwv yuav tsum ua raws li cov kev cai ntawm fiber ntau, cable thiab enclosure es tsis yog ib tug generic nqi luam los ntawm lwm yam khoom.

Kauj Ruam 7: Kaw thiab kaw qhov kho

Tsuas yog tom qab lub splice, cable tuav thiab routing tau raug kuaj xyuas yuav tsum tau muab kaw.

Cov txheej txheem ntxaws ntxaws rau cable- kev npaj nkag, sib khi, kev sib txuas ntawm lub tais thiab rov qab mus rau yav tom ntej - nkag mus rau cov txheej txheem kaw kaw es tsis yog qhov poob no - phau ntawv kho. Saib Glory'sFiber Splice Kaw Installation & Re-nrhiav daim ntawv teev nperau cov kauj ruam ntawd.

Xaiv qhov kaw uas haum rau kev kho

Lub kaw lus siv rau kev kho sab nraum zoov mus tas li yuav tsum tiv thaiv ntau dua li lub tes tsho splice. Nws kuj yuav tsum tswj cov cable mechanically thiab ib puag ncig.

Kev xav tau Kho kev txiav txim siab
Cable txoj kab uas hla Puas yog txhua qhov kev foob nkag tau txhawb nqa qhov poob cable OD?
Tus naj npawb ntawm fibers Puas txaus splice txoj haujlwm muaj yam tsis muaj qhov loj me me?
Lub zog- tuav tswv cuab Cov kab hluav taws xob puas tuaj yeem thauj khoom ntawm nws tus kheej los ntawm fiber ntau?
Fiber routing Puas muaj qhov chaw tswj tau txaus rau lub splice thiab slack?
Environmental raug Lub sealing tsim tsim nyog rau qhov chaw?
Installation txoj hauj lwm Cov khoom puas tsim nyog rau phab ntsa, ncej, tes qhov, duct lossis lwm yam kev npaj tso?
Re- nkag Kev kho puas tuaj yeem nkag mus ntxiv yam tsis muaj kev cuam tshuam rau lub foob?
Cable kev taw qhia Puas yog qhov enclosure geometry haum rau kev kho hauv kab lossis kev npaj ceg?
Txoj cai xaiv:Rau ib qho - lossis ob - cov neeg siv khoom fiber ntau poob, txoj kab uas hla nkag, sealing mechanism thiab strain relief tej zaum yuav muaj teeb meem ntau dua li seb qhov kaw puas tuaj yeem tuav tau ntau lub fibers.

Glory cov pej xeemfiber optic enclosure ntau yamsuav nrog cov network feem ntau -level FTTH thiab OSP enclosures. Rau kev kho cov neeg siv khoom poob qis, lees paub qhov tseeb cable- nkag ntau yam, splice kev npaj thiab kev teeb tsa ib puag ncig ua ntej kho qhov kaw loj dua li kev hloov pauv ncaj qha rau lub hom phiaj- tsim kho qhov kaw kaw.

Txheeb xyuas qhov Kev Kho Ua ntej Kaw Daim Npav Tsis Txaus

Cov kev pabcuam hauv Is Taws Nem rov qab yog cov pov thawj muaj txiaj ntsig, tab sis nws tsis yog los ntawm nws tus kheej sau cov kho qhov muag zoo.

Kev pov thawj yuav tsum ua raws li tus tswv network cov cai xeem.

Tshawb xyuas txoj kev kho qhov muag

Nyob ntawm lub network, kev txheeb xyuas tuaj yeem suav nrog:

  • ONT/ONU optical zog;
  • PON zog ntsuas;
  • insertion-kev ntsuas poob;
  • OTDR taug qab qhov twg yuav tsum tau;
  • kev sib piv nrog cov kev ntsuas yav dhau los los yog siv.

Tsis txhob tsim lub universal lees txais splice poob lossis tau txais - lub zog pib. Siv cov kev txwv uas tau teev tseg rau cov chav kawm PON tiag tiag, tus neeg teb xov tooj thiab qhov project.

Tshawb xyuas txhua qhov txuas uas cuam tshuam

IEC 61300-3-35: 2022 suav nrog kev tshuaj xyuas qhov muag thiab kev faib tawm ntawm kev sib kis thiab qhov tsis xws luag ntawm fiber-optic connector interfaces.

Tus qauv qhia meej meej tias kev tshuaj xyuas qhov muag yogntxiv rau, thiab tsis hloov, kev ntsuas kev ua tau zoo xws li attenuation thiab rov poob. SaibIEC 61300-3-35: 2022 Kev Ua Haujlwm.

Ib qho huv si - saib txuas yog li tsis tsim kom kho qhov muag kho qhov muag hla nws qhov kev txwv.

Hloov kho cov ntaub ntawv kho dua tshiab

Yam tsawg kawg nkaus, sau tseg:

  • tus neeg siv khoom lossis txuas ID;
  • qhov chaw txhaum;
  • pom tsis ua hauj lwm hom;
  • kho lossis hloov txoj kev;
  • siv cable / enclosure;
  • post- kho qhov muag pom;
  • txhua qhov OTDR tshiab yuav tsum tau los ntawm tus neeg teb xov tooj;
  • txoj kev hloov;
  • rov kho hnub tim.

Rau tag nrho qhov project handover thiab txais cov ntaub ntawv, Glory qhov uas twb muaj lawmFTTP Installation Acceptance Checklistnpog cov ntaub ntawv txoj kev, cov khoom siv, cov pov thawj kho qhov muag, cov duab, kev zam thiab cov ntaub ntawv rov ua dua tshiab.

Tiv thaiv rov qab FTTH Drop Cable puas

Kev tiv thaiv yuav tsum tau hais txog lub cev lub cev uas ua rau tsis ua haujlwm es tsis yog tsuas yog txhim kho lwm lub cable hauv tib txoj kev.

Tiv thaiv cov neeg ua haujlwm raug xa mus

Qhov twg ua teb, drilling, kho dua tshiab lossis rov ua dua tuaj yeem:

  • txav cov kab hluav taws xob tawm ntawm thaj chaw muaj kev cuam tshuam uas ua tau;
  • siv cov kav dej tsim nyog lossis kev tiv thaiv txhua yam;
  • tiv thaiv tsev - nkag mus;
  • ruaj ntseg xoob sab nraud cable;
  • tuav txoj hauv kev uas txheeb xyuas tau rau kev ua haujlwm yav tom ntej.

Tsis txhob cuam tshuam cov tee uas twb muaj lawm thaum lub sij hawm rub tawm cov kab tshiab

NTT qhov kev tshawb nrhiav xyoo 2014 muab piv txwv muaj txiaj ntsig. Nws cov kev tiv thaiv suav nrog kev txhim kho ib qho kev sib cais ntawm qhov kev ua tau zoo thiab, qhov twg lwm lub cable yuav tsum tau muab tso rau hauv ib lub kav dej uas muaj cov khoom siv kho qhov muag uas twb muaj lawm, saib xyuas seb cov cable uas twb muaj lawm txav los yog muaj kev quab yuam ntau dhau.

Siv cov cuab yeej txhawb nqa kom raug

Aerial poob cable yuav tsum tsis txhob nyob ntawm qhov kho qhov muag cable nws tus kheej kom nqus tsis tau cov tensile load.

Siv cov clamps thiab kev txhawb nqa kho vajtse haum rau:

  • kab geometry;
  • kev xa xov;
  • ncua;
  • tso cai mechanical load;
  • txheej txheem installation.

Muab cov kab txuas rau ib puag ncig

ITU-T L.105 ua rau kev teeb tsa ib puag ncig ntawm cable- kev txiav txim siab xaiv. Ib txoj kev yuav xav tau kev txiav txim siab ntawm:

  • Kev hloov hauv tsev / sab nraum zoov;
  • noo noo thiab dej raug;
  • UV raug;
  • aerial mechanical load;
  • duct installation;
  • nas los yog kab txaus ntshai;
  • qhov kub thiab txias.

Qhov no txhais tau tias RFQ yuav tsum piav qhiaqhov twg qhov poob yuav raug ntsia, tsis tsuas yog thov "1F G.657 FTTH nco cable."

Khaws cov ntaub ntawv txoj kev siv tau

Qhov tseeb txoj hauv kev thiab cov ntaub ntawv txiav tawm txo qhov ua yuam kev - lub sijhawm tom qab. Rau kev rov xa tawm FTTH rov qab, khaws cia:

  • Terminal thiab chaw nres nkoj ID;
  • tus neeg siv khoom poob txoj kev;
  • hom kab;
  • kwv yees ntsia ntev;
  • connector configuration;
  • splice qhov chaw;
  • cov ntaub ntawv lees paub cuam tshuam.

FTTH Drop Cable Kho Kev Txiav Txim Siab

Kev txiav txim siab Lus nug
Fault domain Puas yog qhov teeb meem tau lees paub hauv txoj kev poob qis?
Network xeev Puas yog PON nyob, thiab cov qauv kev xeem xaiv puas txhawb nqa hauv - kev kuaj kev pabcuam?
Qhov chaw txhaum Puas yog qhov kev puas tsuaj pom, VFL-locatable lossis OTDR-locatable?
Tshaj Puas muaj ib qho kev puas tsuaj hauv zos lossis cov pov thawj ntawm kev puas tsuaj loj dua?
Cable mob Puas yog ob qho tib si seem cables muaj suab nrov?
Ua haujlwm ntev Puas muaj kev noj qab haus huv txaus rau kev npaj, tuav thiab slack?
Txoj kev kho dua tshiab Hloov, nruab nrab - ncua splice, rov- txiav tawm, lossis nruab ib qho tshiab ua ntej- txiav tawm?
Kev tiv thaiv Puas yog lub kaw lus sib phim cable OD, splice suav, sealing thiab mounting tej yam kev mob?
Txais Qhov kev txwv kho qhov muag thiab cov qauv ntsuas twg txhais tau tias kho tau zoo?
Kev tiv thaiv Yuav ua li cas yuav tsum hloov kom lub cev ua rau tib lub cev tsis rov muaj dua?

Rau kev yuav khoom, cable, davhlau ya nyob twg, enclosure thiab connector xaiv yuav tsum ua raws li qhov kev kho kom zoo nkauj architecture es tsis tau teev raws li cov khoom tsis cuam tshuam.

FAQ

Q: Puas tuaj yeem txiav FTTH nco cable ua fusion spliced?

A: Yog, thaum qhov kev puas tsuaj nyob hauv cheeb tsam thiab txaus noj qab haus huv cable tseem nyob rau kev npaj, strain nyem thiab tiv thaiv fiber ntau routing. Sab nraum zoov nruab nrab- ncua kev kho ib txwm xav tau ib lub thawv uas haum rau cov kab thiab ib puag ncig tiag tiag. Yog hais tias qhov kev khiav yog luv luv los yog kev puas tsuaj ncua dhau ib qho taw tes, kev hloov ua tiav yuav yog cov tshuaj ntxuav kom huv.

Q: Kuv puas yuav tsum siv VFL lossis OTDR txhawm rau nrhiav qhov poob cable?

A: Siv lub cuab yeej uas phim qhov txhaum. VFL tuaj yeem pab tau rau txoj hauv kev luv luv thiab ze ntawm cable kawg; OTDR muaj txiaj ntsig zoo dua thaum qhov kev ncua deb mus rau qhov xwm txheej zais yuav tsum ntsuas. Tsis txhob cia siab rau lub universal cable-length pib. Ntawm PON nquag, OTDR thiab qhov ntsuas wavelength kuj yuav tsum tsim nyog rau hauv - kev kuaj kev pabcuam.

Q: Tus qauv OTDR puas tuaj yeem txuas ncaj qha mus rau PON nyob?

A: Tsis yog raws li txoj cai dav dav. Kev daws teeb meem nyob PON xav tau ib txoj hauv kev uas tsis cuam tshuam nrog kev pabcuam wavelengths lossis nthuav tawm cov ntsuas ntsuas thiab lub network nquag mus rau qhov kev sim tsis tsim nyog. Lim nyob rau hauv -kev pabcuam OTDR systems feem ntau siv tawm- ntawm-band 1625 lossis 1650 nm kev xeem, raug rau lub network thiab tus neeg ua haujlwm txheej txheem.

Q: Lub teb txuas puas tuaj yeem hloov qhov nruab nrab -span splice?

A: Ib lub teb txuas tuaj yeem tsim nyog rau qhov kev pom zoo xaus lossis rov- txiav tawm. Kev nthuav tawm nruab nrab - ncua kev so sab nraum zoov ib txwm xav tau txoj kev kho uas muab kev tuav pov hwm cable, kev tiv thaiv ib puag ncig thiab kev tswj hwm fiber ntau. Tsis txhob kho lub connector ib leeg raws li kev kho sab nraum zoov ua tiav.

Q: Puas yog G.657 khoov- tsis muaj fiber ntau tiv thaiv kev puas tsuaj rau lub cev?

A: Tsis yog. G.657 fiber ntau txhim kho khoov kev ua tau zoo nyob rau hauv nws cov kev cai tshwj xeeb, tab sis cov kab tiav tseem tuaj yeem raug puas tsuaj los ntawm kev nruj, crushing, ntse kinking, kev tsim kho lossis tsis ua haujlwm ntawm nws cov khoom tiv thaiv.

Q: Puas yog qhov txuas huv huv txaus los lees txais qhov txuas kho?

A: Tsis yog. Kev tshuaj xyuas qhov sib txuas yog qhov tseem ceeb, tab sis IEC 61300-3-35: 2022 hais tias kev tshuaj xyuas qhov muag tsis hloov qhov kev ntsuas qhov muag. Kev lees txais yuav tsum siv cov kev ntsuas thiab cov kev txwv uas xav tau los ntawm tus tswv network.

Xaus

FTTH nco cable kho dua tshiab yog ib theem ntawm kev txiav txim siab engineering es tsis yog ib qho kev sib txuas.

Ua ntej tshaj tawm tias qhov hluav taws xob yog qhov tseeb hauv txoj kev poob qis. Nrhiav ntu cuam tshuam siv cov pov thawj pom, lub zog kho qhov muag, VFL lossis qhov tsim nyog OTDR. Tom qab ntawd xaiv cov kev hloov ua tiav, kev sib txuas hauv zos- kho qhov sib txuas, qhov kawg re- txiav lossis hloov nrog qhov ua ntej - txiav tawm.

Rau kev kho kom ruaj khov, rov ua kom lub zog ntawm lub zog thiab lub zog ntawm lub zog kom zoo zoo li qhov kho qhov muag sib txuas, tiv thaiv kev sib koom ua ke hauv ib qho chaw sib txuam nrog rau cable thiab ib puag ncig, thiab txheeb xyuas txoj kev kho qhov muag tiv thaiv tus neeg teb xov tooj qhov kev lees paub.

Thaum kawg, kho qhov xwm txheej uas ua rau muaj kev puas tsuaj. Kev tiv thaiv kab mob, kev tsim kho kab, kev txhawb nqa kho vajtse, txoj kev teeb tsa thiab cov ntaub ntawv siv tau tag nrho cuam tshuam seb qhov kev sib txuas ntawm cov neeg siv khoom rov qab puas tseem ntseeg tau.