Cov lus qhia no suav nrog cov txheej txheem kho qhov muag tsis pom kev ntawm FTTH tes hauj lwm - los ntawm kev ua raws li cov qauv thiab kev xaiv cov khoom siv rau kev siv nyiaj kho qhov muag, cov ntaub ntawv pov thawj ntawm lub Hoobkas, thiab kev teeb tsa. Nws yog sau rau telecom engineers, ISP project managers, thiab procurement teams txiav txim siab tivthaiv rau GPON deployments, XGS-PON upgrades, thiab greenfield FTTH rollouts. Qhov twg muaj feem cuam tshuam, nws hais txog cov ntaub ntawv qhia txog pej xeem los ntawm Corning, CommScope, HUBER + SUHNER, thiab ITU-T cov qauv qauv.
§1 - Standards & Certification Framework
Passive optical Cheebtsam rau FTTH thiab FTTx yuav tsum ua raws li txheej txheej hierarchy ntawm ITU-T, IEC, thiab cov qauv hauv cheeb tsam. Cov lus hauv qab no qhia txog cov ntawv pov thawj uas siv rau ntawm Glory Optical's Ningbo manufacturing chaw. Qhov twg tus qauv muaj cov ntawv nyeem ncaj qha rau pej xeem, qhov chaw txuas.
Ib qho tseem ceeb uas yuav tsum nco ntsoov ntawm kev xaiv fiber ntau: ITU-T G.652.D thiab G.657.A2 feem ntau tau sib tham ua lwm txoj hauv kev, tab sis hauv kev xyaum lawv hais txog ntau ntu ntawm tib lub network. Corning daim ntawv thov rau ntawmkhoov-kev xaiv fiber ntau rau FTTHmuab cov ntaub ntawv siv tau zoo rau kev nkag siab qhov twg G.657 qib ntxiv tus nqi tiag tiag piv rau qhov twg tus qauv G.652.D feeder cable tsim nyog. Cov lus teb luv luv: G.657.A2 lossis B3 tau lees paub hauv MDU zaum kawg -poob thiab hauv- kev tsim kho; feeder thiab faib ntu feem ntau zoo nrog G.652.D.
| Standard / Cert | Scope | Siv rau | Kev siv | xwm txheej |
|---|---|---|---|---|
| ITU-T G.652.D | Standard singlemode SMF - attenuation Tsawg dua los yog sib npaug rau 0.2 dB/km @ 1550 nm | Feeder cables, patch cords, pigtails | itu.int/rec/T-REC-G.652 | TSEEM CEEB |
| ITU-T G.657.A1/A2 | Khoov-sensitive SMF - min khoov vojvoog 10 mm (A1) / 7.5 mm (A2) | Sab hauv tsev poob cables, phab ntsa- qhov hluav taws xob pigtails | itu.int/rec/T-REC-G.657 | TSEEM CEEB |
| ITU-T G.657.B3 | Ultra-khoov-insensitive - 5 mm min khoov vojvoog | MDU riser, nruj -chaw nyob sab hauv tsev routing | itu.int/rec/T-REC-G.657 | TSEEM CEEB |
| ITU-T G.984.x (GPON) | Gigabit PON - ODN Class B+ (28 dB) thiab C+ (32 dB) poob peev nyiaj | ODN splitters, enclosures, thav ntawv | itu.int/rec/T-REC-G.984.1 | VALIDATED |
| ITU-T G.9807.1 (XGS-PON) | 10G Symmetric PON - N1/N2/E1/E2 ODN chav kawm, 9.95328 Gbps kab tus nqi | XGS-PON tau tshaj ODN cov khoom | itu.int/rec/T-REC-G.9807.1 | VALIDATED |
| IEC 61754 Kev Ua Haujlwm | Fiber optic connector interfaces - SC, LC, FC, MPO form factor | Txhua hom connector tsim | ib.ch | CERTIFIED |
| IEC 60794-1 / 2 / 3 | Optical fiber ntau cable - mechanical and environmental test methodology | Tag nrho cov khoom siv cable | ib.ch | CERTIFIED |
| Telcordia GR-326-CORE | Cov kev cai dav dav rau singlemode optical connectors thiab jumper sib dhos | SC / APC, SC / UPC, LC / UPC connectors | Ericsson Standards Portal | CERTIFIED |
| Telcordia GR-771-CORE | Cov kev cai dav dav rau fiber ntau optic splice kaw | Dome, kab rov tav, thiab inline splice kaw | Ericsson / Telcordia Standards Archive | CERTIFIED |
| IEC 60529 Kev Tswj Xyuas Kev Tswj Xyuas IP68 | Plua plav- nruj thiab dej raus dej (Ntau dua lossis sib npaug li 1 m / 30 min yam tsawg kawg nkaus) | Tag nrho cov kab thaiv sab nraum zoov thiab splice kaw | ib.ch | CERTIFIED |
| TIA-568.3-D | Optical fiber cable Cheebtsam tus qauv - qauv cabling | Cov ntaub ntawv chaw MPO / MTP sib dhos, thaj vaj huam sib luag | TIA Standards | TSEEM CEEB |
| ISO 9001: 2015 | Quality Management System | Kev ua haujlwm puv ntoob | iso.org | CERTIFIED |
| CE / RoHS ntawv pov thawj | EU kev ua raws cai thiab txwv tsis pub muaj tshuaj lom | Tag nrho cov khoom rau EU lag luam | EU Commission | CERTIFIED |
| ITU-T G.9804.3 (50G-PON) | Tom ntej no - tiam 50G symmetric PON - rau pem hauv ntej- tau tshaj ODN infrastructure | ODN passive txheej yog tiam -agnostic | itu.int/rec/T-REC-G.9804.3 | INFRASTRUCTURE CEEB TOOM |
IEC 61754 series txhais lub cev qhov ntev thiab kev kam rau siab rau fiber ntau optic connector hom. Rau cov ntawv thov FTTH, IEC 61754-4 (SC) thiab IEC 61754-20 (LC) yog qhov cuam tshuam. HUBER + SUHNER tshaj tawm qhov muaj txiaj ntsigconnector xaiv referenceuas maps hom connector rau daim ntawv thov ib puag ncig - tshwj xeeb tshaj yog muaj feem xyuam rau SC/APC vs SC/UPC kev txiav txim siab hauv PON ports.
§2 - ODN Network Architecture & Topology
Optical Distribution Network spans from theOptical Line Terminal (OLT)nyob rau hauv lub central chaw ua hauj lwm rau txhua tus neegOptical Network Terminal (ONT).. Nws yog tag nrho passive - tsis muaj hluav taws xob siv hluav taws xob, tsis muaj hluav taws xob hauv thaj teb. Qhov no yog dab tsi muab ODN tsim kom zoo nws ntau - xyoo caum kev pab cuam lub neej thiab nws compatibility nyob rau PON tiam.
ITU-T G.984 thiab G.9807.1 tus qauv txhais cov chav kawm poob nyiaj uas txwv ODN tsim, tab sis lawv tawm cov kev txiav txim siab ntawm architecture - cais piv, ntu ntev, feeder topology - rau tus neeg teb xov tooj. CommScope covFTTH infrastructure kev npaj cov peev txheejthiab Broadband Forum's TR-247 yog cov ntaub ntawv muaj txiaj ntsig zoo rau kev xaiv topology, tshwj xeeb tshaj yog rau cov neeg ua haujlwm hnyav nruab nrab piv rau cov tswv yim sib faib.
Split Ratio Architecture Models
| Qauv | 1st Theem Split | 2nd Theem Split | Total Ratio | Hom Siv Case | Max ODN Loss (GPON B +) |
|---|---|---|---|---|---|
| Tib -Stage Centralized | 1 × 32 lossis 1 × 64 ntawm FDT | Tsis muaj | 1:32–1:64 | Dense nroog MDU, tsev kawm ntawv | 18.5–21.5 dB |
| Ob -theem faib | 1 × 4 lossis 1 × 8 ntawm FDH | 1 × 8 lossis 1 × 16 ntawm NAP | 1:32–1:128 | Suburban Greenfield FTTH | 20-23.5 dB |
| Cascaded (Peb-theem) | 1 × 2 ntawm lub taub hau | 1 × 4 ntawm node, 1 × 8 ntawm poob | 1:64 | Nyob deb nroog / ntev - mus txog PON | 24-28 dB (chav kawm C + yuav tsum tau) |
| XGS-PON N2 Class | 1 × 8 ntawm FDH | 1 × 16 ntawm FAT | 1: 128 max | 10G symmetric access rollout | 16-31 dB qhov rais pob nyiaj siv |
Optical Loss Budget Reference - GPON Class B+ (28 dB), 1:32 Split, 10 km
| Loss Component | Specification | Tus nqi |
|---|---|---|
| Fiber ntau attenuation (10 km @ 1310 nm) | G.652.D Tsawg dua lossis sib npaug li 0.4 dB/km | 4.0dB ua |
| PLC Splitter 1 × 32 (IL) | ITU-T G.671 | 15.8 dB |
| Connectors (4 khub × 0.35 dB max) | IEC 61754 / GR-326 Kev Ua Haujlwm Zoo | 1.4 dB ib |
| Splice poob (8 fusion splices × 0.1 dB) | IEC 61300-3-33: Cov | 0.8dB ib |
| Kev laus thiab tsim cov npoo | Tus neeg khiav dej num txoj cai | 1.5dB ib |
| Tag nrho kwv yees poob | 23.5 dB- hauv 28 dB pob nyiaj siv |
XGS-PON (G.9807.1) coexists nrog GPON ntawm tib ODN los ntawm kev siv cov sib txawv downstream wavelengths: GPON ntawm 1490 nm, XGS-PON ntawm 1577 nm. Qhov no wavelength txoj kev npaj - teev nyob rau hauv G.9807.1 Table 3 - txhais tau tias tsis muaj WDM lim hloov yuav tsum tau nyob rau theem splitter. Lub passive ODN infrastructure yog rov qab siv tag nrho. Lub Broadband Forum'sTR-247 (XGS-PON Coexistence)muab tag nrho architectural thiab wavelength cais cov cai rau kev sib xyaw ua ke.
Cheebtsam Xaiv los ntawm ODN Segment
1 × 2 txog 1 × 64, ABS / LGX / cassette, SC / APC tus qauv
2–24 chaw nres nkoj, phab ntsa-mount / ncej-mount, SC/APC lossis LC
§3 - Factory Test Data & Performance Evidence
Glory Optical tuav ib qho hauv -lub tsev kuaj qhov muag qhov muag ntawm nws qhov chaw Ningbo. Tag nrho cov khoom tau dhau 100% kev kuaj pom ua ntej ua zaub mov xa tuaj. Cov ntaub ntawv hauv qab no yog rub los ntawm cov khoom tsim tawm hauv Q4 2024 thiab Q1 2025. Batch- cov ntawv qhia qib hauv PDF hom muaj rau OEM cov koom tes thiab cov neeg siv xov tooj tsim nyog cov kev pab cuam raws li kev thov.
Rau cov ntsiab lus ntawm qhov "zoo" qhov poob zoo li thoob plaws kev lag luam: Corning'spassive optical feem specificationsthiab HUBER + SUHNER'sib -fiber connector datasheetsua hauj lwm pab raws li kev siv benchmarks rau insertion poob, rov poob, thiab mating durability yuav tsum tau.
PLC Splitter Insertion Poob - Cov ntaub ntawv ntau lawm
| Split Ratio | Lub wavelength | Hom IL (dB) | Max IL Spec (dB) | Uniformity (dB) | Rov Los Loss (dB) | Kev tshwm sim |
|---|---|---|---|---|---|---|
| 1×2 | 1310/1490/1550 nm | 3.5 | 3.8 | Tsawg dua lossis sib npaug li 0.3 | Ntau dua lossis sib npaug li 55 | PASS |
| 1×4 | 1310/1490/1550 nm | 6.8 | 7.0 | Tsawg dua los yog sib npaug li 0.5 | Ntau dua lossis sib npaug li 55 | PASS |
| 1×8 | 1310/1490/1550 nm | 10.0 | 10.5 | Tsawg dua lossis sib npaug li 0.6 | Ntau dua lossis sib npaug li 55 | PASS |
| 1×16 | 1310/1490/1550 nm | 13.1 | 13.5 | Tsawg dua lossis sib npaug li 0.8 | Ntau dua lossis sib npaug li 55 | PASS |
| 1×32 | 1310/1490/1550 nm | 15.8 | 16.5 | Tsawg dua los yog sib npaug rau 1.0 | Ntau dua lossis sib npaug li 55 | PASS |
| 1×64 | 1310/1490/1550 nm | 19.0 | 20.0 | Tsawg dua los yog sib npaug li 1.5 | Ntau dua lossis sib npaug li 55 | PASS |
SC/APC Pigtail & MPO Assembly - Insertion Poob Data
| Khoom | Fiber suav | Qib | Avg IL (dB) | Max IL (dB) | Min RL (dB) | Daim ntawv thov |
|---|---|---|---|---|---|---|
| MPO-12 Lub cev | 12 | Hom A (Elite) | 0.20 | 0.35 | Ntau tshaj los yog sib npaug rau 60 | 40G / 100G SR4 |
| MPO-24 Lub cev | 24 | Hom A (Elite) | 0.22 | 0.35 | Ntau tshaj los yog sib npaug rau 60 | 100G / 400G SR8 |
| MPO-12 Cassette | 12 MPO → 12 LC | Txuj | 0.25 | 0.50 | Ntau dua lossis sib npaug li 55 | 10G / 40G |
| SC/APC Pigtail | Singlemode | APC | 0.10 | 0.20 | Ntau dua lossis sib npaug li 65 | GPON / XGS-PON |
Environmental & Mechanical Test Results
Cov kev ntsuam xyuas hauv qab no ua raws li IEC cov txheej txheem. HUBER + SUHNER tau tshaj tawm cov ntawv sau qhia txogfiber optic kaw ib puag ncig kev tsim nyogthiab CommScope's splice kaw installation cov lus qhia muab kev sib piv cov ntaub ntawv muaj txiaj ntsig rau IP68 thiab thermal cycling kev lees txais.
| Kuaj | Txuj | Cov xwm txheej / Duration | IL Hloov Observed | Txiav txim |
|---|---|---|---|---|
| Kub Cycling | IEC 60068-2-14: Cov | −40℃rau +85 degree, 100 cycles | < 0.05 dB | PASS |
| Cua sov | IEC 60068-2-78: Cov | 85℃/ 85% RH, 2000 h | < 0.08 dB | PASS |
| IP68 Dej Immersion | IEC 60529 (TSI) | 1m, 24 h | 0 dB (tsis muaj ingress pom) | PASS |
| Ntsev Txau Corrosion | IEC 60068-2-11 | 5% NaCl, 500 h | Tsis muaj structural degradation | PASS |
| Tensile Load (FTTH nco cable) | IEC 60794-1-E1 | 80n,60 ua | < 0.1 dB during load | PASS |
| Crush Resistance (lub cev kaw) | IEC 60794-1-E7 | 220 N / 100 hli | Tsis ua hauj lwm los yog deformation | PASS |
| UV Aging (sab nraum zoov HDPE tsho) | IEC 60794-1-F10 | 1000 h raug | Tsis muaj lub tsho tawg | PASS |
| SC / APC Mating Durability | IEC 61300-2-2: 2 | 500 mating cycles | IL hloov <0.2 dB cumulative | PASS |
Ib qho kev tsis txaus siab rov tshwm sim los ntawm cov kws ua haujlwm hauv teb yog tias cov ntaub ntawv xa khoom xa tawm qhia cov kev txwv tshwj xeeb tab sis tsis ntsuas qhov kev faib khoom. Raws li -batch IL xeem ntawv tshaj tawm - teev cov nqi ntsuas qhov tseeb thoob plaws kev tsim khoom, tsis yog tsuas yog min / max txwv - muaj rau cov neeg koom tes OEM tsim nyog thiab cov neeg ua haujlwm yuav khoom. Hu rau peb pab pawg muag khoom kom thov cov qauv qhia ua ntej yuav khoom.
§4 - Kev Xyaum Ua Haujlwm & Kev Qhia Kev Txhim Kho
ODN passive txheej teeb lub qab nthab rau kev ua haujlwm network rau lub neej ntawm kev xa tawm - feem ntau 20-30 xyoo. Installation zoo ntawm commissioning txiav txim siab npaum li cas ntawm qhov theoretical qab nthab yog tiag tiag tiag. Cov lus hauv qab no suav nrog ob txoj kev xa tawm ntau tshaj plaws, hom kev ua haujlwm tsis zoo uas tau pom hauv thaj chaw, thiab cov kauj ruam tshwj xeeb uas tiv thaiv lawv.
Ua ntej-Connectorized vs. Fusion Splice Deployment
Ua ntej-connectorized systems tau dhau los ua txoj hauv kev tseem ceeb rau qhov kawg -tso xa mus rau qhov siab tshaj - nrawm FTTH rollouts vim tias lawv txo cov nqi zog ua haujlwm thiab tshem tawm qhov xav tau ntawm cov khoom siv fusion splice rau ib pab neeg. Kev lag luam tawm - me ntsis siab dua connector poob piv rau fusion splice poob - feem ntau tsis cuam tshuam rau hauv GPON Class B+ thiab XGS-PON N1/N2 poob peev nyiaj thaum seem ntawm qhov txuas yog tsim kom raug. Corning's EDGE Architecture thiab zoo sib xws ua ntej -connectorized systems los ntawm CommScope (UniCam, OptiTap) tau lees paub txoj hauv kev no nyob rau hauv loj -scale tus neeg teb xov tooj rollouts thoob ntiaj teb; lawv cov ntawv qhia kev xa tawm tau tshaj tawm tau hais nyob rau hauv cov ntaub ntawv hauv qab no.
| Parameter | Tsoos Fusion Splice | Ua ntej-Connectorized | Sau ntawv |
|---|---|---|---|
| Installation lub sij hawm ib poob | 45–90 feeb | 12–20 feeb | Xws li fiber ntau routing, txuas, thiab OTDR check |
| Kev txawj ua haujlwm yuav tsum tau ua | Kev cob qhia fusion splicer tus neeg teb xov tooj | Cov kws tshaj lij hauv cheeb tsam | Txo cov nqi kev cob qhia thiab cov neeg ua haujlwm tshwj xeeb |
| Tus nqi cuab yeej rau ib pab neeg | $3,000–$8,000 ( tshuab fusion) | $50–$200 (cov cuab yeej siv tes nkaus xwb) | Qhov tseem ceeb CapEx txo ntawm qhov ntsuas |
| Kev sib txuas poob (tus qauv) | 0.02-0.05dB (kev sib txuas) | 0.10-0.20 dB (qhov txuas txuas) | Hauv pob nyiaj siv rau feem ntau ODN chav kawm - txheeb xyuas ib qhov project |
| Re- nkag / reconfiguration | Yuav tsum tau re-splice, kaw re- nkag | Plug-thiab-ua si, feeb | Ua ntej-conn yeej ntawm OpEx rau kev txav / ntxiv / hloov pauv |
Common Field Failure Modes & Yuav Ua Li Cas Kom Zam Lawv
Cov kev ua tsis tiav hauv qab no tshwm sim tsis tu ncua thoob plaws cov lus tawm tswv yim los ntawm cov neeg ua haujlwm xa tawm. Tsis muaj leej twg yog tshwm sim los ntawm cov khoom zoo ib leeg - txhua qhov cuam tshuam nrog kev txiav txim siab ntawm kev teeb tsa lossis cov txheej txheem sib txawv.
| Hom kev ua tsis tiav | Keeb kwm | Kev tiv thaiv |
|---|---|---|
| Txhim kho qhov poob ntawm qhov txuas (pom ntawm OTDR lees txais kev xeem) | Kab mob kawg- ntsej muag - plua plav, roj, lossis polishing residue tsis ntxuav ua ntej mating | Yuav tsum tau IEC 61300-3-35 qhov kawg-lub ntsej muag tu raws tu qauv. Khaws SC/APC plua plav kaus mom kom txog thaum lub sijhawm tso. Siv cov kev soj ntsuam fiber ntau los xyuas kom meej ua ntej mating. |
| Cov dej noo ingress nyob rau hauv splice kaw (pom 6-18 lub hlis tom qab-xa mus rau huab cua sov) | Tsis raug cable nkag lub caj pas torque, los yog O-ntiv nplhaib tsis zaum ua ntej kaw | Siv IP68- ntsuas dome kaw nrog ob lub O-ring sealing. Ua raws li torque specifications nyob rau hauv daim ntawv installation. Ua 24-teev kev ntsuas qhov siab ntawm kev kaw hauv av ua ntej rov ua dua. |
| FTTH cable tsho UV tawg (3-5 xyoos ntawm huab cua poob) | Tsis yog-UV-txhawb HDPE lub tsho tau teev tseg, lossis UV stabilizer tsis tau lees paub nrog tus muag khoom | Qhia meej txog UV-stabilized dub PE tsho rau IEC 60794-1-F10, yam tsawg kawg nkaus 1000 h UV ntsuas. Txheeb xyuas ntawm daim ntawv pov thawj, tsis yog daim ntawv thov xwb. |
| Noog thiab nas puas rau saum huab cua poob (ntau ntau hauv Africa, SEA, kev xa mus nyob deb nroog) | Unarmored daim duab-8 cable ntawm spans tshaj lub cable rated sag nrug | Rau qhov ntev> 60 m, siv tus kheej - txhawb ADSS. Rau luv luv spans nrog noog / nas txaus ntshai, qhia cov armored FTTH poob nrog stainless- cov tswv cuab lub zog steel. |
| Cov xwm txheej muaj kev cuam tshuam siab ntawm cov chaw nres nkoj splitter (pom pom ntawm OTDR kab raws li qhov kev tshwm sim) | APC thiab UPC connectors mated ua ke - lub 8℃lub kaum sab xis mismatch ua rau muaj zog xav | Standardize ntawm SC/APC thoob plaws tag nrho ODN PON txoj kev. SC / APC (lub cev ntsuab) rau txhua qhov chaw nres nkoj PON thiab tag nrho cov pigtails ntawm OLT rau ONT. Tsis txhob sib xyaw nrog SC / UPC ntawm tib txoj kev kho qhov muag. |
| Splice kaw gasket hardening thiab foob tsis ua hauj lwm (hauv av nyob rau hauv cov cheeb tsam nrog dav kub viav vias) | Txheem EPDM gasket tsis ntsuas rau tag nrho cov kev khiav hauj lwm kub ntau yam | Rau kev xa tawm nrog ambient kub hauv qab -20 degree, qhia cov khoom siv silicone gasket. Xyuas kom tseeb tias qhov ntsuas kub ntawm gasket yog sau rau ntawm daim ntawv kaw. |
Txhua qhov kev xa tawm fiber ntau yuav tsum tau txheeb xyuas nrog OTDR ua ntej kev pabcuam -nce. Qhov ntsuas yuav tsum tau ua los ntawm ob qhov kawg. Kev lees txais qhov pib: tsis muaj qhov tshwm sim poob> 0.35 dB ib qhov txuas, tsis muaj fusion splice poob> 0.1 dB, tag nrho qhov txuas poob hauv cov nyiaj suav nrog rau cov qauv tsim. Tag nrho cov kab xeem yuav tsum tau muab khaws cia ua lub hauv paus rau kev daws teeb meem yav tom ntej. HUBER + SUHNERcov ntaub ntawv siv fiber ntau testermuab cov ncauj lus kom ntxaws OTDR txheej txheem rau FTTH lees txais kev kuaj.
§5 - Field Documentation & Deployment Video References
Cov ntawv sau tshwj xeeb piav qhia seb cov khoom yuav tsum ua li cas. Cov ntaub ntawv video hauv qab no qhia tias qhov kev teeb tsa raug zoo li cas hauv kev xyaum - splice kaw sealing, ua ntej -connectorized poob installation, thiab OTDR commissioning. Cov no yog cov kev cob qhia uas muaj rau pej xeem thiab cov ntaub ntawv siv los ntawm cov tswv lag luam thiab cov chaw tsim khoom.
Peb tab tom tsim lub tsev qiv ntawv ntawm cov ntaub ntawv teeb tsa tshwj xeeb rau peb cov khoom lag luam - splice kaw sealing txheej txheem, PLC splitter installation cov lus qhia, thiab ua ntej -connectorized davhlau ya nyob twg thaiv daim duab. Cov ntaub ntawv teeb tsa tam sim no muaj nyob rau hauv PDF downloads ntawm txhua nplooj ntawv khoom. Yog tias koj xav tau ib lub vev xaib- cov lus qhia tshwj xeeb rau kev xa tawm OEM loj, hu rau peb pab pawg muag khoom.
§6 - Kev Tshawb Fawb Kev Tshawb Fawb
Cov ntaub ntawv tshawb fawb hauv qab no yog kos los ntawm qhov tseeb Glory Optical muab kev koom tes. Cov npe ntawm qhov project thiab tus neeg ua haujlwm tus kheej raug txiav tawm ntawm NDA; lub teb chaws, scale, thiab technical parameters yog qhov tseeb.
§7 - Cov Lus Nug & Lus Teb
Q: Dab tsi yog ODN hauv fiber ntau optic tes hauj lwm?
A: Ib qho Optical Distribution Network (ODN) yog tag nrho cov khoom siv hluav taws xob txuas nrog lub hauv paus chaw ua haujlwm Optical Line Terminal (OLT) rau txhua tus neeg siv khoom Optical Network Terminal (ONT). Txhais raws li ITU-T G.984 (GPON) thiab G.9807.1 (XGS-PON), nws muaj fiber ntau feeder, PLC splitters, tis cables, nco cables, txiav lub thawv, thiab connectors - tag nrho passive, yuav tsum tsis muaj hluav taws xob fais fab hauv teb. ODN tsim tau zoo txhawb nqa 20–30+ xyoo network lifespans thiab yog sib xws nyob rau hauv ntau yam PON technology tiam yam tsis muaj passive feem hloov.
Q: Dab tsi yog qhov txawv ntawm GPON thiab XGS-PON?
A: GPON (ITU-T G.984) xa 2.5 Gbps nqes mus thiab 1.25 Gbps ntws ntws hla PON sib koom. XGS-PON (ITU-T G.9807.1) muab symmetric 9.95 Gbps nyob rau hauv ob qho tib si kev taw qhia. Ob leeg ua haujlwm dhau ib qho passive ODN - tsis muaj kev hloov pauv rau fiber ntau, splitters, kaw, lossis faib cables yuav tsum tau ua rau kev txhim kho. Qhov sib txawv tseem ceeb yog nyob rau hauv cov khoom siv nquag (OLT kab phaib thiab cov neeg siv ONTs) thiab cov phiaj xwm kho qhov muag: XGS-PON siv 1577 nm nqes hav thiab 1270 nm sab saud, thaum GPON siv 1490 nm thiab 1310 nm feem. Qhov kev sib cais wavelength no tso cai rau GPON thiab XGS-PON cov kev pabcuam sib koom ua ke ntawm tib ODN ib txhij thaum lub sijhawm tsiv teb tsaws.
Q: Kuv yuav suav li cas cov nyiaj siv kho qhov muag poob rau FTTH network?
A: Ntxiv tag nrho cov khoom poob ntawm OLT thiab ONT: (1) fiber ntau attenuation × ncua ntev (G.652.D yog Less dua los yog sib npaug rau 0.35 dB/km @ 1310 nm), (2) PLC splitter insertion poob - piv txwv li, 15.8 dB rau ib qho kev sib txuas 5 × 30. (3 . dB ib khub niam txiv), (4) fusion splice poob (feem ntau 0.05–0.1 dB txhua), thiab (5) tus qauv tsim ntawm 1–3 dB rau kev laus, kev hloov pauv ib puag ncig, thiab cov xwm txheej npaj txhij txog. Tag nrho cov nyiaj yuav tsum tsis pub tshaj OLT chav kawm: GPON Chav B+=28 dB, Chav Kawm C+=32 dB; XGS-PON N1=29 dB, N{23}} dB. Cov piv txwv ua haujlwm hauv §2 ntawm cov ntaub ntawv no qhia tau hais tias ib txwm suav.
Q: Dab tsi IP ntsuam xyuas ua sab nraum zoov fiber ntau splice kaw xav tau?
A: Sab nraum zoov fiber ntau splice kaw nyob rau hauv FTTH xa mus yuav tsum tau raws li qhov tsawg kawg nkaus ntawm IP68 ib IEC 60529 - ua tiav plua plav- nruj kev tiv thaiv thiab dej immersion peev xwm kuaj ntawm ntau dua los yog sib npaug rau 1 meter qhov tob rau qhov tsawg kawg nkaus ntawm 30 feeb, txawm tias 24 teev ntawm 1 m yog qhov kev ua tau zoo tshaj plaws. Rau hauv av lossis dej nyab- kev teeb tsa kev pheej hmoo, qhia cov kev kaw kaw rau IP68 ntawm 3 m lossis qhov tob dua. Nyob rau hauv ntug dej hiav txwv los yog siab - av noo ib puag ncig, kuj yuav tsum tau ntsev tsuag tshuaj tiv thaiv ib IEC 60068-2-11 (feem ntau 500 h ntawm 5% NaCl). Glory Optical dome thiab kab rov tav kaw muaj IP68 ntawm 1 m / 24 h thiab ntsev tsuag rau qhov tshwj xeeb no.
Q: PLC splitters puas siv tau rau hauv ob qho tib si GPON thiab XGS-PON networks?
A: Yog. PLC (Planar Lightwave Circuit) splitters yog inherently wavelength- ywj siab hla 1260–1650 nm, uas npog GPON (1310/1490 nm), XGS-PON (1270/1577 nm), NG{{9}5 RF bands (thiab ntau tshaj) nm) ib txhij. PLC splitter ntsia rau GPON network tsis tas yuav hloov pauv thaum lub sijhawm XGS-PON hloov kho, lossis rau ib qho PON tiam tom ntej uas khiav hauv lub qhov rais wavelength no. Central Europe cov ntaub ntawv kawm nyob rau hauv §6 ntawm cov ntaub ntawv no muab ib tug tiag tiag - ntiaj teb kev ntsuas kev pom zoo ntawm XGS-PON wavelengths.
Q: Dab tsi fiber cable tus qauv yuav tsum tau rau FTTH sab hauv tsev thaiv?
A: ITU-T G.657.A1 lossis A2 yog tus qauv rau FTTH sab hauv tsev poob cables. G.657.A1 tso cai rau qhov tsawg kawg nkaus khoov vojvoog ntawm 10 hli; G.657.A2 tso cai rau 7.5 hli - haum rau cov ces kaum nruj hauv MDU chav tsev thaiv. Rau ultra-tight conduit routing los yog riser daim ntaub ntawv, G.657.B3 (5 hli yam tsawg kawg nkaus khoov vojvoog) tej zaum yuav raug teev. Tag nrho peb qib yog thim rov qab- sib haum nrog G.652.D tus qauv SMF rau kev sib txuas thiab cov khoom sib txuas. Rau sab nraum zoov aerial lossis underground feeder ntu, tus qauv G.652.D feem ntau txaus thiab tsis tshua kim.
Q: Ntau npaum li cas ua ntej -connectorized FTTH txo lub sij hawm xa tawm piv rau fusion splice?
A: Hauv Philippines kev xa tawm cov ntaub ntawv hauv §6, ua ntej- txuas txuas txuas nruab nrab 18 kev teeb tsa rau ob -tus neeg ua haujlwm hauv ib hnub, piv rau 7 tus neeg ua haujlwm hauv ib hnub rau fusion-splice ntawm tib pab pawg ua haujlwm. Qhov kom zoo dua ntawm kev ceev yog feem ntau los ntawm kev tshem tawm fusion tshuab teeb thiab splice tray tswj ntawm qib poob. Kev lag luam tawm yog qhov kawg ntawm kev sib txuas -kev qhuab qhia kev huv huv ua qhov tseem ceeb - tib txoj haujlwm tau pom 2.3% ua ntej- kis tsis tau tus nqi hauv ib lub lis piam ua ntej qhov yuav tsum tau soj ntsuam cov kauj ruam ntxiv rau kev ua haujlwm.
Q: Vim li cas SC / APC teeb meem thiab kuv tuaj yeem sib xyaw nrog SC / UPC ntawm PON network?
A: SC/APC connectors muaj 8-degree angled kawg- lub ntsej muag uas ua rau pom lub teeb kom tawg mus deb ntawm cov tub ntxhais fiber ntau, ua kom rov qab poob ntau dua lossis sib npaug li 65 dB. SC/UPC connectors muaj lub tiaj tus - polished kawg -lub ntsej muag nrog rov qab poob feem ntau ntau dua los yog sib npaug rau 55 dB. Rau GPON thiab XGS-PON OLT lasers, uas yog rhiab rau rov qab-reflections, APC connectors thoob plaws hauv lub ODN muab kev ua tau zoo dua thiab txo qhov kev pheej hmoo ntawm reflectance{12}}induced lub hwj chim nplua. Koj yuav tsum tsis txhob ua phooj ywg SC / APC nrog SC / UPC ntawm tib txoj kev kho qhov muag - qhov sib txawv ntawm lub cev txhais tau tias kev sib txuas yuav poob thiab tuaj yeem ua rau lub ferrule puas. Standardize ntawm SC / APC (lub cev ntsuab) thoob plaws tag nrho PON chaw nres nkoj txoj kev los ntawm OLT rau ONT.
§8 - Kev Qhia Txog Kev Siv
- [1]ITU-T Kev Pom Zoo G.9807.1 (2016) -10-Gigabit- muaj peev xwm symmetric passive optical network (XGS-PON). International Telecommunication Union.itu.int/rec/T-REC-G.9807.1
- [2]ITU-T Kev Pom Zoo G.984.1–G.984.7 -Gigabit{0}}muaj peev xwm Passive Optical Networks (GPON). International Telecommunication Union.itu.int/rec/T-REC-G.984.1
- [3]ITU-T Kev Pom Zoo G.657 (2021) -Cov yam ntxwv ntawm dabtsi yog khoov- poob insensitive ib leeg- hom kho qhov muag fibers thiab cables rau lub network nkag. Txhais A1, A2, B3 qib thiab lawv qhov tsawg kawg nkaus khoov vojvoog specifications.itu.int/rec/T-REC-G.657
- [4]ITU-T Kev Pom Zoo G.652 (2016) -Cov yam ntxwv ntawm ib qho - hom optical fiber ntau thiab cable. G.652.D yog qhov tseem ceeb feeder thiab faib fiber ntau specification rau FTTH ODN.itu.int/rec/T-REC-G.652
- [5]Corning Incorporated -SMF-28 Ultra Optical Fiber Khoom Qhia. Specifications rau Corning's G.652.D / G.657.A2 raws li fiber ntau, suav nrog attenuation, khoov poob, thiab PMD qhov tseem ceeb.corning.com - SMF-28 Ultra datasheet (PDF)
- [6]Corning Incorporated -Khoov-Kev xaiv tsis zoo Fiber rau FTTH daim ntawv thov. Daim ntawv ceeb toom hais txog G.657 cov qauv xaiv qib, sib txuas tau zoo, thiab kev tuav teb.corning.com - Khoov-Insensitive Fiber White Paper (PDF)
- [7]CommScope -FTTH Infrastructure Solutions: Fiber rau Kev Npaj Hauv Tsev & Kev Xa Khoom. Topology qauv, cais piv cov lus qhia kev xaiv, thiab splice kaw installation cov ntaub ntawv.commscope.com/solutions/networks/fiber-rau -lub -tsev
- [8]CommScope -Fiber Optic Splice Kaw Installation & Technical Documentation. Cov lus qhia kev teeb tsa npog qhov sib khi torque, cov txheej txheem cable nkag mus rau hauv lub caj pas, thiab IP68 kev ntsuas siab rau kev kaw sab nraum zoov.commscope.com - Fiber Access Product Catalog
- [9]HUBER+SUHNER -Fiber Optic Connectors: Tib -Fiber Product Range & Technical Datasheets. SC, LC, thiab FC connector specifications suav nrog kev poob, rov qab poob, thiab IEC 61300-2-2 mating durability ratings.hubersuhner.com - Ib leeg-Fiber Connectors
- [10]HUBER+SUHNER -Fiber Optic Kaw rau Sab Nraud Daim Ntawv Thov. Cov ntaub ntawv qhia txog kev tsim nyog ib puag ncig ntawm kev sib txuas kaw, suav nrog IP68 kev sim txheej txheem thiab xaiv cov khoom siv gasket rau huab cua sov thiab arctic.hubersuhner.com - Fiber Optic Kaw
- [11]HUBER+SUHNER -FTTA (Fiber rau kav hlau txais xov) Kev daws teeb meem rau 5G Fronthaul. Sab nraum zoov fiber ntau txuas rau 5G me me ntawm tes thiab C-RAN daim ntawv thov, suav nrog IP68 CPRI thaj qaum cov lus qhia.hubersuhner.com - FTTA Solutions
- [12]Telcordia GR -326-CORE -General Requirements rau Singlemode Optical Connectors thiab Jumper Assemblies. Ericsson (yav tas los Telcordia). North American connector qualification standard covering insertion poob, rov poob, thiab durability testing.Ericsson Telecom Standards Portal
- [13]Telcordia GR -771-CORE -General Requirements rau Fiber Optic Splice Kaw. Ericsson / Telcordia. Txhais kev sib khi, kev siv tshuab, thiab ib puag ncig kev ua tau zoo rau kev sib txuas sab nraum zoov siv hauv North American network xa tawm.
- [14]IEC 61754 (IEC 61754) - Ntu 4 (2013)Fiber optic interconnecting li - Ntu 4: SC connector. Txhais lub cev qhov ntev, kam rau ua, thiab kev xeem yuav tsum tau ua rau SC connector interface.ib.ch
- [15]Broadband Forum TR-247 -XGS-PON Coexistence nrog GPON. Cov kev cai tsim vaj tse rau kev siv XGS-PON hla ib qho GPON ODN uas twb muaj lawm, suav nrog kev sib cais wavelength, kev ua ke OLT cov cai, thiab cov tswv yim tsiv teb tsaws.broadband-forum.org
- [16]ISO 9001: 2015 -Quality Management Systems - Yuav tsum muaj. International Organization for Standardization.iso.org/standard/62085
§9 - Glory Optical Product Range
Glory Optical manufactures passive optical network Cheebtsam ntawm nws qhov chaw Ningbo, Zhejiang. Cov khoom lag luam npog txhua txheej passive ntawm FTTH ODN, los ntawm feeder splice kaw rau cov neeg siv khoom - sab txiav lub thawv thiab cov khoom sib txuas.