Yuav ua li cas rau nruab ib Fiber Optic Termination Box (Step-by-Step)|GloryOptics

Mar 23, 2026

Tso lus

Fiber Optic Terminal Closure​
Cov kev daws teeb meem muaj zog rau kev lag luam loj hlob

Fiber optic termination box (FTB) yog qhov kawg taw tes hauv FTTH lossis FTTB network ua ntej lub teeb liab mus txog tus neeg siv khoom. Thaum nws raug ntsia kom raug, lub thawv tiv thaiv koj cov fiber ntau cables, ua kom tsis muaj qhov poob qis dua 0.3 dB ib qho kev sib txuas, thiab muab lub network ntev, teeb meem - pub dawb lub neej. Thaum nws tau teeb tsa tsis zoo, koj tau txais cov teeb liab poob, dej puas, thiab rov qab mus ntsib uas raug nqi ntau dua li lub thawv nws tus kheej.

Phau ntawv qhia no hais txog txhua kauj ruam hauv cov lus yooj yooj yim. Nws yog sau los ntawm pab neeg engineering ntawmGlory Optical Kev Sib Txuas Lus- ib lub chaw tsim khoom fiber ntau optic raws li hauv Ningbo, Tuam Tshoj, nrog 15+ xyoo dhau los thiab 1,200+ ua tiav FTTH cov haujlwm thoob plaws 60+ lub teb chaws.

1. Ua ntej koj pib: Xaiv lub thawv zoo thiab sau koj cov cuab yeej

Ua ntej koj qhib ib lub cable los yog kov ib lub tais splice, ob yam yuav tsum yog: lub thawv yuav tsum phim rau ib puag ncig uas nws yuav raug ntsia, thiab txhua lub cuab yeej yuav tsum nyob ntawm qhov chaw ua haujlwm. Kev nres ib nrab ntawm - txoj hauj lwm los nrhiav ib lub cuab tam uas ploj lawm yog ib qho laj thawj vim li cas cov kws tshaj lij hla kev soj ntsuam cov kauj ruam - uas ua rau 90% ntawm kev xa tawm - teeb liab teeb tsa ua tsis tiav.

1.1 Xaiv txoj cai IP ntsuas rau lub xaib

IP ntsuam xyuas yog qhov tseem ceeb tshaj plaws spec rau txhua qhov kev txiav tawm sab nraum zoov fiber ntau. Nws qhia rau koj paub tias lub qhov rooj tiv thaiv plua plav thiab dej zoo npaum li cas. Kev ntsuas ntsuas yog txhais los ntawm IEC 60529 / EN 60529.

 

IEC 60529 / EN 60529 Daim Ntawv Pov Thawj:Cov txheej txheem thoob ntiaj teb uas txhais tau tias IP (Ingress Protection) kev ntaus nqi. Thawj tus lej (0–6)=qib tiv thaiv plua plav. Tus lej thib ob (0–8)=qib tiv thaiv dej. Ob tus lej yuav tsum ua raws li qhov chaw nyob.

 

Qhov chaw ib puag ncig

Pom zoo IP

Tus IP Theem txhais li cas (IEC 60529)

Glory Series

Cov khoom siv sab hauv tsev (qhuav)

IP54

Plua plav- tiv thaiv + txaws los ntawm txhua qhov kev taw qhia

Sab hauv phab ntsa-Mount

Sab hauv qab daus los yog riser (damp)

IP55

Plua plav- tiv thaiv + dav hlau dej los ntawm txhua qhov kev taw qhia

Sab hauv phab ntsa-Mount

Sab nraum phab ntsa lossis ncej (qhib nag)

IP65

Plua plav- nruj + dav hlau dej ntawm 6.3 L / min los ntawm 3 m rau 15 min

Sab nraum zoov phab ntsa/Pole

Underground vault los yog dej nyab cheeb tsam

IP68

Plua plav- nruj + submersion - Lub hwjchim ci ntsa iab spec: 1 m qhov tob / 72 h

Sab nraum zoov IP68 Series

Ntug hiav txwv lossis ntsev -air site

IP68 + ntsev tsuag

Ib yam li saum toj no + 96 h ntsev tshuaj tsuag (IEC 60068-2-11)

Sab nraum zoov IP68 Marine

 

⚠ Qhov tseem ceeb:Tsis txhob cia siab rau tus neeg tsim khoom tus kheej - tshaj tawm qhov ntsuas IP. Nug rau qhov thib peb -toj xeem tsab ntawv ceeb toom los ntawm SGS lossis TÜV. Lub hwjchim ci ntsa iab muab IP xeem ntawv ceeb toom rau txhua qhov tawm sab nraum zoov. Cov ntaub ntawv teb los ntawm 1,200+ tau teeb tsa Glory sab nraum zoov chav nyob rau sab hnub tuaj Asia (2022–2025): xoom dej ingress hauv IP68 units; 3.2% teeb meem foob nyob rau hauv IP65 units nyob rau hauv siab -cov av noo nyob rau hauv tropical aav tom qab 24 lub hlis - tag nrho cov taug qab mus rau hauv qab - torqued cable caj pas, tsis muaj vaj tse tsis ua hauj lwm.

1.2 Sau txhua lub cuab yeej ua ntej koj pib

Teem tawm tag nrho cov cuab yeej ua ntej qhib ib qho cable. Ib lub cuab tam uas ploj lawm ib nrab ntawm - txoj hauj lwm yog qhov feem ntau yog vim li cas cov kws tshaj lij hla cov kauj ruam soj ntsuam txuas.

Tool

Nws Ua Dab Tsi

Standard / Spec kom ntsib

Fusion Splicer

Koom nrog fiber ntau xaus nrog ze -zero insertion poob

Lub hom phiaj IL Tsawg dua los yog sib npaug rau 0.05 dB rau ib qho splice (IEC 61300-3-4)

Fiber ntau cleaver

Txiav fiber ntau tsawg dua los yog sib npaug rau 0.5℃lub kaum sab xis ua ntej splicing

Lub kaum sab xis> 1℃muab IL> 0.1 dB - hloov cov hniav thaum hnav

Fiber stripping cuab tam

Tshem tawm cov txheej tsis khawb fiber ntau

Peb- kauj ruam strip: tsho → 900 µm tsis → 250 µm txheej

Fiber ntau (200 × yam tsawg kawg nkaus)

Tshawb xyuas cov connector endfaces ua ntej tso

Yuav tsum tau IEC 61300-3-35; siv ua ntej txhua mating

OLTS (lub zog ntsuas + qhov chaw)

Ntsuas qhov poob ntawm qhov txuas ua tiav

IEC 61280-4-1 (singlemode) / IEC 61280-4-2 (ntau hom)

OTDR tester

Captures cov kab hauv qab thiab nrhiav qhov tsis raug

IEC 61280-4-3 - txuag .SOR cov ntaub ntawv ntawm kev xa mus

Cable caj pas torque wrench

Tightens caj pas kom spec - tiv thaiv IP foob tsis ua haujlwm

Glory PG-series qog: 2.5–3.5 Nm

IPA cov ntaub so + ib qho - nyem huv

Cleans fiber ntau kawg thiab lub tes tsho adapter

Ntxuav ua ntej txhua qhov kev soj ntsuam thiab sib tov - tsis muaj qhov zam

Cable khi + Velcro straps

Ruaj ntseg fiber ntau coils hauv lub tais

Yam tsawg kawg nkaus coil txoj kab uas hla: 60 mm - tsis dhau -tighten Velcro

M6 torque tsav

Mounts lub thawv rau phab ntsa lossis ncej

Min 50 mm thauj tog rau nkoj tob rau hauv pob zeb

 

2. 8 Cov kauj ruam ntawm kev teeb tsa

Cov kauj ruam hauv qab no siv rau phab ntsa-mount thiab ncej-mount FTBs siv hauv FTTH thiab MDU networks. Khib-mount installations ua raws li tib splice thiab xeem cov kauj ruam tab sis hla cov kauj ruam 3–4.

Kauj ruam 1 - Mount lub Enclosure

Phab ntsa Mount

Kos rau plaub txoj haujlwm thauj tog rau nkoj uas siv daim ntawv drilling template nrog rau lub thawv. Laum M6 qhov mus rau qhov tsawg kawg nkaus qhov tob ntawm 50 mm rau hauv pob zeb lossis masonry. Siv cov ntsia hlau thauj tog rau nkoj nrog lub tes tsho nthuav dav - tsis yog yas ntsaws - rau sab nraum zoov masonry.

Khaws lub thawv qib kom tsis pub dhau ± 2 degree. Lub tais tilted ua rau fiber ntau so tawm ntawm ib sab ntawm lub vojvoog qhia thiab ntxiv micro- dabtsi yog khoov kev ntxhov siab dhau sijhawm. Cia qhov tsawg kawg nkaus ntawm 300 mm qhov chaw ntshiab hauv qab lub thawv kom lub xaim xaim tuaj yeem nkag nrog qhov khoov du.

Ncej mount

Siv cov stainless hlau band clamps nkag nrog lub thawv. Haum rau kev tiv thaiv- kev co roj hmab liner ntawm lub clamp thiab tus ncej ua ntej zawm. Tighten ob lub clamps sib npaug - tsis sib xws torque tsim ib lub zog sib tw uas tuaj yeem cuam tshuam tus IP gasket lub sijhawm.

Mount lub thawv ntawm qhov siab tsawg kawg yog 2.5 m los ntawm hauv av. Qhov no yog qhov tsawg kawg nkaus tshem tawm rau sab nraum zoov ODN cov cuab yeej pom zoo los ntawm ITU-T L.37.

⚠ Qhov tseem ceeb:Tsis txhob mount lub thawv nrog lub cable nkag ports taw rau sab saud. Cov dej ntws raws lub tsho cable thiab nkag mus rau hauv lub caj pas xov. Point cable nkag downward los yog sideways.

Kauj Ruam 2 - Npaj thiab taug txoj kev poob Cable

Tshem lub tsho cable rau 150-200 mm. Tsis txhob nick lub buffer raj los yog fiber ntau txheej thaum txiav. Ua kom cov tswvcuab lub zog steel tsis tu ncua - nws txuas rau lub zog nyem nyem hauv lub thawv thiab siv tag nrho cov quab yuam rub tawm ntawm cov fiber ntau.

Txuas lub cable rau hauv lub thawv los ntawm qhov chaw nres nkoj cable nkag. Cia 1.5 m ntawm fiber ntau slack hauv lub thawv. Qhov no slack coils mus rau hauv lub nplhaib cia thiab muab ntev txaus rau re-splice yog hais tias ib tug splice tsis soj ntsuam tom qab.

Kauj Ruam 3 - Kaw lub Cable nkag (Tshwj xeeb rau IP65 / IP68)

Cov kauj ruam no yog qhov uas feem ntau IP tsis ua haujlwm pib. Cov kab hluav taws xob yuav tsum sib npaug rau sab nraud (OD) ntawm koj lub cable. Siv daim ntawv loj loj ntawm lub thawv ntawv lossis hauv daim ntawv teev cov khoom.

Xaiv lub caj pas kom raug rau lub cable OD. Lub caj pas uas loj dhau rau lub cable yuav tsis kaw, txawm tias thaum nruj nruj.

Xov lub cable los ntawm lub compression txiv ntseej thiab caj pas lub cev ua ntej lub caj pas yog screwed rau hauv lub thawv. Tsis nco qab cov kauj ruam no txhais tau tias rub lub cable rov qab tawm.

Xauv lub caj pas rau hauv lub thawv chaw nres nkoj. Tes- nruj ua ntej, tom qab ntawd siv lub torque wrench kom ncav cuag 2.5–3.5 Nm (rau Glory PG-series caj pas). Tsis txhob dhau -tight - nws tawg PG xov.

Rau qhov chaw IP68: nias lub thawv ntim rau 0.2 bar siv lub twj tso kua mis tes thiab tuav rau 60 vib nas this. Submerge nyob rau hauv ib lub thoob dej. Tsis muaj npuas=zoo foob.

 

Kauj Ruam 4 - Tshem tawm thiab ntxuav cov Fiber

 

Ua haujlwm ntawm qhov chaw huv, tiaj tus. Fiber hais tsis pom thiab ntse. Khaws cov khoom siv fiber ntau rau hauv lub thawv kaw - tsis txhob cia lawv poob rau ntawm qhov chaw ua haujlwm lossis hauv pem teb.

Strip nyob rau hauv peb kauj ruam: (1) tshem lub tsho sab nrauv, (2) strip lub 900 µm buffer raj, (3) strip lub 250 µm txheej. So cov liab qab fiber ntau nrog qhuav IPA so kom tshem tawm cov coating residue.

Tshem cov fiber nrog ib rab riam huv. Lub hom phiaj lub kaum ntse ntse: Tsawg dua lossis sib npaug li 0.5 degree. Cov hniav uas muaj ntau tshaj 5,000 txiav muab cov ces kaum tsis sib xws. Hloov ntawm lub voj voog teem sijhawm, tsis yog thaum nws zoo li hnav.

Tshawb xyuas qhov kawg cleaved nyob rau hauv lub cleaver lub koob yees duab los yog ib tug fiber ntau. Tshem tawm txhua qhov kawg nrog daim di ncauj, tawg, lossis lub kaum sab xis siab dua 1 degree.

⚠ Qhov tseem ceeb:Tsis txhob tshuab rau liab qab fiber ntau los ntxuav nws. Moisture los ntawm kev ua tsis taus pa tso cov roj rau ntawm qhov chaw thiab ua rau kom poob qis. Siv cov ntaub so IPA nkaus xwb.

Kauj Ruam 5 - Fusion Splice Fiber rau hauv Splice Tray

Muab cov cua sov- txo lub tes tsho tiv thaiv mus rau ib qho fiber ntau ua ntej thauj ob lub fibers rau hauv cov hlua khi. Tsis nco qab lub tes tsho txhais tau tias koj yuav tsum txiav thiab rov ua dua -splice.

Load ob fibers thiab khiav qhov kev sib dhos tsis siv neeg thiab kev sib txuas. Feem ntau cov splicers qhia qhov kwv yees qhov poob ntawm qhov screen.

Txais splices nrog IL Tsawg dua lossis sib npaug rau 0.05 dB. Yog hais tias tus splicer qhia IL> 0.1 dB, txiav cov splice thiab rov ua dua. Tsis txhob txais ib qho marginal splice thiab vam tias qhov tshwm sim nyob twj ywm hauv spec tom qab siv cov cua sov.

Nruab lub tshav kub-txo lub tes tsho hla lub splice thiab txav mus rau qhov cub cua sov. Tshav kub tsawg kawg 60 vib nas this ntawm 190 degree. Kos: tsis muaj npuas, tsis muaj fiber ntau nthuav tawm ntawm qhov kawg.

Muab qhov ua tiav splice rau hauv qhov splice tais qhov. Tso lub tshav kub-shrink tube tiaj tus thiab sib npaug mus rau lub tais. Tsis txhob muab lub tes tsho rau saum ib leeg.

Rov ua dua rau txhua qhov fiber ntau. Feem ntau FTBs tuav 1-4 splice tais. Txhua lub tais tuav 12-24 splices nyob ntawm tus qauv.

Kauj ruam 6 - Route Pigtails thiab Insert Connectors

6a - Txoj kev pigtails los ntawm splice tais rau lub vaj huam sib luag adapter

Qhia txhua tus pigtail los ntawm lub tais splice los ntawm cov kev sib txuas mus rau lub vaj huam sib luag adapter. Siv cov ntawv qhia ua ntej - tsim cov vojvoog. Tsis txhob rub lub pigtail nruj. Yuav tsum muaj qhov xoob, ntuj arc - tsis muaj qhov khoov ntse.

Coil tej qhov ntev pigtail ntev nyob rau hauv lub nplhaib cia fiber ntau. Ruaj ntseg lub kauj nrog Velcro pluaj, tsis yog hlua khi. Ib txoj hlua khi nruj tuaj yeem tsoo cov txheej fiber ntau thiab tsim kom muaj micro- khoov taw tes poob. Yam tsawg kawg nkaus coil txoj kab uas hla: 60 mm.

6b - Tshawb xyuas txhua qhov txuas ua ntej tso

Siv lub fiber ntau ntawm 200 × magnification. Ua raws li kev soj ntsuam-huv-tsim raws tu qauv:

Tshawb xyuas lub ntsej muag ua ntej kev ntxuav.

Yog tias tsis yog Qib A: siv ib qho - nyem lub tshuab ntxhua khaub ncaws, tom qab ntawd ib daim ntaub qhuav IPA qhuav - dawb so.

Tshawb xyuas dua. Yog tias tseem tsis tau Qib A tom qab ob lub voj voog huv si: lub connector muaj lub cev tsis xws luag thiab yuav tsum tau hloov, tsis rov- ntxuav.

Ntxig txhua qhov txuas txuas rau hauv nws lub adapter. SC / APC connectors nyem rau hauv nrog ib lub laub. Yog hais tias lub connector tsis zaum, xyuas cov plua plav nyob rau hauv lub tes tsho adapter thiab ntxuav nws nrog ib tug stick cleaner.

Kauj ruam 7 - Sau tag nrho cov chaw nres nkoj

Sau txhua qhov chaw nres nkoj ua ntej kaw lub thawv. Cov chaw nres nkoj tsis muaj npe ua rau yuam kev - fiber ntau cuam tshuam thaum kho, uas ua rau muaj kev cuam tshuam hauv lub network.

Siv tus kheej- cov ntawv laminating ntsuas rau qhov ntsuas kub ntawm qhov chaw. Daim ntawv lo rau hauv lub thawv IP65 / IP68 yuav tsis muaj sia nyob los yog cua sov.

Daim ntawv lo hom: [Port ID] - [Circuit ID] - [Destination]. Piv txwv li: P-04 - MDU-B3-UNIT12 - OLT-PORT-07.

Rau kev xa tawm loj: QR- cov ntawv sau code tso cai rau cov kws tshaj lij rub tawm cov ntaub ntawv hluav taws xob los ntawm lub xov tooj. Lub hwjchim ci ntsa iab muab QR- cov kev pabcuam sau npe ntawm OEM xaj.

Kauj ruam 8 - Kuaj thiab Sau

Tsis txhob kaw lub thawv thiab tawm ntawm qhov chaw yam tsis muaj ob qhov kev xeem ua tiav: kev ntsuas qhov poob qis thiab OTDR kab. Cov kev ntsuam xyuas no ua pov thawj tias qhov kev teeb tsa yog qhov tseeb thiab muab koj lub hauv paus rau txhua qhov kev nrhiav txhaum yav tom ntej.

8a - Insertion poob test (OLTS method)

Txuas lub calibrated launch cable los ntawm qhov chaw kho qhov muag. Txuas lub ntsuas hluav taws xob ntawm qhov kawg. Ntsuas qhov kawg-rau- xaus qhov poob. Tshem tawm cov kev siv cable poob kom tau qhov txuas tsis tau.

Kev sib txuas Point

TIA-568.3-E Max Tso cai IL

Glory Premium Target

Mated adapter khub (SC)

0.75 dB

Tsawg dua lossis sib npaug li 0.30 dB

Mated adapter khub (LC)

0.75 dB

Tsawg dua lossis sib npaug li 0.25 dB

Fusion splice (ib splice)

0.30 dB

Tsawg dua lossis sib npaug li 0.05 dB

Full FTB link end-to-end

Raws li OLTS lub hauv paus

Chij txhua tus nqi> 0.5 dB rau kev tshuaj xyuas

⚠ Qhov tseem ceeb:Yog tias ib qho txuas qhia IL> 0.3 dB thaum lub sijhawm kuaj OLTS, tsis txhob txais qhov txuas. Tshem tawm lub connector, rov- tshuaj xyuas nyob rau hauv lub fiber ntau, huv si, thiab sim dua. Ib qho kev sib txuas tsis zoo uas dhau hnub no yuav ua rau muaj kev puas tsuaj ntxiv thiab ua rau muaj kev puas tsuaj hauv lub hlis.

8b - OTDR puag ncig taug qab

Teem lub OTDR wavelength kom phim lub network: 1310 nm thiab 1550 nm rau singlemode GPON. Siv 100-200 m tua kab hluav taws xob kom dhau los ntawm OTDR qhov chaw tuag (feem ntau 10-20 m) yog li thawj splice ntawm FTB nkag tau pom ntawm kab.

Txuag cov ntaub ntawv taug qab hauv Bellcore .SOR hom tam sim ntawd tom qab qhov kev xeem. Sau lub filename tiv thaiv qhov chaw nres nkoj ID hauv koj cov ntaub ntawv ua haujlwm. Cov kab no yog koj qhov txhaum- nrhiav kev siv rau tag nrho lub neej ntawm lub network.

OTDR hom kev tshwm sim

Flag Threshold

Kev nqis tes ua yog Tshaj

Splice tshwm sim (reflective poob)

>0.10 dB

Re-splice thiab retest

Connector reflectance (SC / APC)

>-45 dB ORL

Ntxuav connector, rov kuaj dua; hloov yog nws tseem

Connector reflectance (SC / UPC)

>-35 dB ORL

Ntxuav connector, rov kuaj dua; hloov yog nws tseem

Kev xav tsis pom kev (kink lossis tawg)

Txhua yam tsis yog -splice reflection tshwm sim

Nrhiav thiab kho lub cev puas tsuaj

3. Feem ntau Installation yuam kev (thiab yuav ua li cas zam lawv)

Cov lus hauv qab no yog los ntawm Glory qhov kev tshuaj xyuas ntawm cov chaw xa rov qab, kev hu xov tooj, thiab cov neeg siv khoom tawm tswv yim los ntawm cov haujlwm hauv Southeast Asia, Africa, thiab Europe ntawm 2021 thiab 2025. Cov no yog cov qauv ua tsis tiav los ntawm kev xa tawm tiag.

yuam kev

Dab tsi mus yuam kev

Yuav Tiv Thaiv Li Cas

Hauv qab -torqued cable caj pas

IP foob tsis ua haujlwm; dej nkag rau hauv lub thawv; fiber ntau corrodes los yog so

Siv lub torque wrench rau cov chaw tsim khoom spec (2.5–3.5 Nm rau Glory PG qog)

Lub caj pas tsis ncaj ncees rau cable OD

Lub foob tsis compress ncig lub cable; dej nkag mus txawm tias tag nrho nruj

Ntsuas cable OD nrog lub caliper; phim rau daim kab xev loj hauv daim ntawv teev cov khoom

Fiber coil < 30 mm vojvoog hauv lub tais

Khoov poob ntawm 0.3-1.5 dB ntxiv rau fiber ntau; teeb liab degrades lub sij hawm

Siv cov qauv tsim ua - hauv 30 mm vojvoog qhia; Tsis txhob yuam cov fiber ntau rau hauv ib lub voj kaw ntom ntom

Hla kev soj ntsuam cov connector

Cov kab mob sib kis ntxiv 0.5–2 dB poob lossis thaiv teeb liab; ua rau 90% ntawm kev tshaj tawm -nruab qhov teeb meem

Tshawb xyuas txhua qhov kawg ntawm 200 × (IEC 61300-3-35) ua ntej kev ntxig - txhua zaus, tsis muaj kev zam

Sib tov SC / APC (ntsuab) nrog SC / UPC (beige) adapters

Rov qab poob poob los ntawm ntau dua lossis sib npaug ntawm 60 dB txog <30 dB; GPON OLT tsa lub tswb los yog poob teeb liab

Xim -code nruj me ntsis: SC/APC=ntsuab; SC/UPC=beige lossis xiav. Tsis txhob sib tov nyob rau hauv tib qhov txuas

Tsis muaj OTDR cov kab hauv qab tau txais kev cawmdim

Kev ua txhaum yav tom ntej tsis tuaj yeem raug cais tawm ntawm qhov kev teeb tsa thawj zaug; kev daws teeb meem siv sijhawm 3-5 × ntev dua

Kev ntes thiab ua ntaub ntawv OTDR kab ntawm kev xa tawm - nws yog cov ntaub ntawv ruaj khov, tsis yog xaiv tau

Cable khi hla- nruj ntawm fiber ntau coil

Micro- khoov kev ntxhov siab ntawm khi taw tes; kev poob nce qeeb zuj zus hauv lub lis piam

Siv Velcro straps ntawm fiber ntau coils hauv lub thawv; Tsis txhob siv tus qauv cable ties ncaj qha ntawm fiber ntau

Cable nkag ports taw tes nce

Dej taug raws lub tsho thiab nkag mus rau hauv lub caj pas tsis hais lub caj pas torque

Mount lub thawv nrog cov chaw nres nkoj nkag mus rau pem hauv ntej lossis sab - kos ua ntej drilling

4. Cov xwm txheej tshwj xeeb: MDU Cov Tsev thiab 5G Qhov Chaw

4.1 Chaw nres nkoj suav Planning rau MDU vaj tse

Chaw nres nkoj suav yog qhov feem ntau misjudged sib txawv nyob rau hauv MDU fiber tej yaam num. Hauv qab -kev txiav txim yog qhov laj thawj tseem ceeb rau rov- xaj: Cov ntaub ntawv muaj koob meej los ntawm 200+ MDU FTTH cov haujlwm hauv Africa thiab Southeast Asia (2021-2025) qhia 72% ntawm re- xaj tau tshwm sim los ntawm underestimating port count at the design stage.

Hom tsev

Pom zoo Box

Chaw nres nkoj suav txoj cai

Mount qhov twg

Ib lub tsev

4-chaw nres nkoj phab ntsa-mount (IP54)

4 ports

Sab hauv phab ntsa, ze ONT

Tsawg- chav tsev nce siab (tsawg dua lossis sib npaug li 12 units)

12-chaw nres nkoj phab ntsa-mount (IP54)

1 chaw nres nkoj ib chav tsev + 20% tsis → puag ncig mus rau ze tshaj 4

Riser lossis IDF txee rau hauv pem teb

Nruab nrab-nce (13–48 units)

24-chaw nres nkoj phab ntsa-mount lossis 2 × 12-chaw nres nkoj

1 chaw nres nkoj rau ib chav tsev + 20% tsis

Rau -chaw telecom hauv pem teb

Siab -nce (49+ units)

48-port 1U khib-mount

48–96 chaw nres nkoj; ib IDF ib pem teb rau cov tsev tshaj 10 pem teb

Main MDF + rau - pem teb IDF

Sab nraum lub tsev nkag

24-chaw nres nkoj IP65 lossis IP68 phab ntsa-mount

24 chaw nres nkoj nrog 20% ​​cia

Sab nrauv phab ntsa los yog hauv av vault

✔ Lub tswv yim zoo:Ntxiv 20% overcapacity rau txhua qhov chaw nres nkoj suav suav. Nws raug nqi yuav luag tsis muaj dab tsi ntawm lub sijhawm tsim. Ntxiv cov chaw nres nkoj tom qab lub network tseem nyob txhais tau hais tias rov qab mus rau qhov chaw, yuav khoom kho vajtse ntxiv, rov- kev xa xov cables, thiab rov- kuaj tag nrho cov txheej txheem xa tawm.

4.2 Txhim kho FTBs ntawm 5G Backhaul Sites

5G macro cell sites feem ntau xav tau ib qho 24-chaw nres nkoj sab nraum zoov IP68 FTB ntawm lub hauv paus chaw nres tsheb cov khoom siv chav tsev, ntxiv rau me me 4-port micro-enclosures ntawm txoj kev-theem me me cell mounts. Fronthaul fiber txuas yuav tsum tuav qhov kawg-rau-kawg qhov kev poob qis kom tsawg dua lossis sib npaug li 0.3 dB ib ntu, yog li cov khoom sib txuas zoo tsis tuaj yeem sib tham ntawm 5G qhov chaw.

Siv SC/APC connectors nkaus xwb ntawm 5G fronthaul txuas. SC / UPC rov qab poob (Ntau dua lossis sib npaug li 50 dB) tsis txaus rau cov peev nyiaj kho qhov muag ntawm qee lub xov tooj cua 5G.

Ntawm tus ncej-tso rau lub hlwb me me, siv IP67 lossis IP68 micro-enclosure nrog lub kaw lus hasp. Txoj kev thaiv kab thaiv yog lub hom phiaj rau tub sab nyiag thiab kev tsim txom.

Khiav OTDR kab nyob rau txhua qhov fronthaul fiber ntau span ntawm ob qho tib si 1310 nm thiab 1550 nm . 5G network ua haujlwm pab pawg xav tau cov ntaub ntawv hauv paus rau SLA qhia.

5. Optical Performance Specs rau Kev Xeem Txais

Cov lus hauv qab no qhia txog cov nuj nqis tseem ceeb uas tau teeb tsa kom raug Glory FTB yuav tsum tau ua. Siv cov lej no raws li koj qhov kev xeem dhau / tsis ua tiav ntawm qhov chaw.

Parameter

Glory Specification

Kev lag luam Benchmark

Txuj

Fusion splice insertion poob

Tsawg dua lossis sib npaug rau 0.05 dB (tus qauv)

Tsawg dua lossis sib npaug li 0.10 dB

IEC 61300-3-4: Tus Qauv Zauv

SC adapter insertion poob

Tsawg dua lossis sib npaug li 0.30 dB

Tsawg dua lossis sib npaug li 0.50 dB (TIA siab tshaj)

IEC 61754-4: Cov

LC adapter insertion poob

Tsawg dua lossis sib npaug li 0.25 dB

Tsawg dua lossis sib npaug li 0.50 dB (TIA siab tshaj)

IEC 61754-20: Ua

Rov qab poob - SC/APC

Ntau dua lossis sib npaug li 60 dB

Ntau dua lossis sib npaug li 55 dB

IEC 61300-3-6: Kev qhia

Rov qab poob - SC/UPC

Ntau dua lossis sib npaug li 50 dB

Ntau dua lossis sib npaug li 45 dB

IEC 61300-3-6: Kev qhia

Yam tsawg kawg khoov vojvoog hauv lub tais

30 mm

30-40 hli

ITU-T G.657

Kev khiav hauj lwm qhov kub thiab txias

-40℃rau +70℃(sab nraum zoov)

−20℃rau +60 degree

IEC 60068-2-14: Cov

IP ntsuam xyuas - sab nraum zoov series

IP65 lossis IP68 (los ntawm series)

IP65 yam tsawg kawg nkaus rau kev siv sab nraum zoov

IEC 60529 (TSI)

 

6. Cov lus nug uas nquag nug

 

Cov lus nug hauv qab no yog los ntawm kev tshawb fawb ntau tshaj plaws los ntawm engineers thiab ISP buyers. Lawv kuj tshwm sim hauv Google's 'Cov Neeg Tseem Ceeb' cov txiaj ntsig rau fiber ntau optic termination box topics.

 

Q1: Dab tsi yog fiber optic termination box siv rau?

Fiber optic termination box yog ib tug enclosure ntawm tus neeg siv khoom kawg ntawm FTTH lossis FTTB network. Nws tiv thaiv cov fusion splices qhov twg lub feeder cable ntsib ib tug neeg poob cables. Nws tuav cov pigtails uas txuas rau thaj qaum mus rau ONT. Nws khaws fiber ntau coils ntawm lub vojvoog khoov kom ruaj ntseg kom cov teeb liab poob qis. Hauv luv luv: nws yog qhov kawg tiv thaiv taw tes ua ntej fiber ntau nkag mus rau tus neeg siv khoom lub tsev lossis chav.

Q2: Qhov txawv ntawm IP65 thiab IP68 rau lub thawv fiber ntau yog dab tsi?

Ob qhov kev ntsuam xyuas yog los ntawm IEC 60529. IP65=tag nrho cov plua plav- nruj thiab tiv thaiv cov dav hlau dej los ntawm txhua qhov kev taw qhia, sim ntawm 6.3 L / min los ntawm 3 m rau 15 feeb. IP68=tag nrho cov plua plav- nruj thiab tiv thaiv tsis tu ncua submersion - Glory's IP68 spec yog 1 m qhov tob rau 72 teev. Siv IP65 rau ncej lossis phab ntsa-nrawm qhov chaw sab nraum zoov. Siv IP68 rau hauv av vaults, cable pits, los yog dej nyab -nruj FTTH cov ntsiab lus nkag.

Q3: Dab tsi ua rau lub teeb liab poob hauv lub thawv fiber ntau?

Plaub ua rau tus account rau yuav luag tag nrho cov ncej- teeb tsa kev teeb tsa poob hauv FTB. (1) qias neeg los yog puas connector endfaces - feem ntau ua rau nyob deb, lub luag hauj lwm rau txog 90% ntawm qhov chaw tawm. (2) Fiber khoov nruj dua li qhov tsawg kawg nkaus 30 hli vojvoog hauv lub tais splice. (3) Lub fusion splice nrog lub kaum ntse ntse qhov yuam kev ntau dua 1℃lossis npuas hauv qhov cua sov- lub tes tsho ntsws. (4) Hom adapter tsis sib haum - ib qho SC/APC connector tso rau hauv SC/UPC adapter tsa qhov kev xav thiab ua rau lub tswb ntawm GPON systems.

Q4: Kuv yuav xaiv qhov kev ntsuam xyuas IP zoo li cas rau kuv qhov chaw?

Pib nrog ib puag ncig. Sab hauv thiab qhuav=IP54. Sab hauv thiab damp=IP55. Sab nraum zoov qhib los nag=IP65. Kev nyab xeeb hauv av lossis dej nyab=IP68. Ntug hiav txwv lossis cua ntsev=IP68 ntxiv rau daim ntawv pov thawj tshuaj tsuag ntsev. Yog tias koj tsis paub meej, mus rau ib qib siab dua. Tus nqi sib txawv ntawm IP65 thiab IP68 yog me me. Ib qho dej-kev puas tsuaj network raug nqi ntau dua.

Q5: Koj ua li cas kuaj lub thawv fiber ntau tom qab kev teeb tsa?

Khiav ob qhov kev xeem. Ua ntej: OLTS qhov ntsuas qhov poob ib qho IEC 61280-4-1. Txuas lub calibrated qhov chaw ntawm lub tswv yim thiab lub hwj chim ntsuas ntawm qhov tso zis. Txais tau poob ib lub adapter: Tsawg dua los yog sib npaug rau 0.75 dB (TIA siab tshaj plaws) lossis Tsawg dua lossis sib npaug rau 0.30 dB (Lub hom phiaj Lub Hwj Chim). Thib ob: OTDR cov kab hauv qab ib qho IEC 61280-4-3. Txuag cov ntaub ntawv .SOR tawm tsam qhov chaw nres nkoj ID hauv koj qhov project cov ntaub ntawv. OTDR txoj kab yog koj qhov kev siv mus tas li rau txhua qhov kev saib xyuas yav tom ntej. Tsis txhob tawm ntawm qhov chaw tsis muaj nws.

Q6: Dab tsi yog qhov tsawg kawg nkaus khoov vojvoog rau fiber ntau hauv ib lub tais splice?

30 hli yog tus qauv yam tsawg kawg nkaus rau G.652.D ib leeg - hom fiber ntau (ib ITU-T G.657). Khoov-insensitive G.657.A2 fiber ntau tuaj yeem nqes mus rau 7.5 hli, tab sis Hwjchim ci ntsa iab tsim tag nrho cov tais splice los tswj 30 hli raws li qhov tsawg kawg nkaus los tiv thaiv txhua hom fiber ntau thiab tsis txhob ntev -lub sij hawm qaug zog. Tsis txhob co co fiber ntau nruj dua li 60 mm inch (30 mm radius) hauv lub thawv.

Q7: Dab tsi HS code siv rau fiber optic txiav lub thawv rau ntshuam?

Feem ntau fiber ntau optic termination thawv yog imported nyob rau hauv HS Code 8536.90 (hluav taws xob apparatus rau switching, tiv thaiv, los yog txuas hluav taws xob circuits) los yog 9001.90 (optical fiber ntsiab thiab bundles). Txoj cai raug yog nyob ntawm cov khoom muaj pes tsawg leeg. Hwjchim ci ntsa iab muab cov ntaub ntawv pov thawj kev lis kev cai nrog txhua qhov kev txiav txim xa tawm: daim ntawv HS code pom zoo, daim ntawv pov thawj ntawm lub hauv paus, daim ntawv them nqi lag luam, thiab cov npe ntim khoom. Hu rau sales@gloryoptics.com rau ua ntej - cov ntaub ntawv xa khoom xa tuaj.

Q8: Kuv puas tuaj yeem tau txais kev cai OEM fiber ntau txiav lub thawv los ntawm Glory?

Yog lawm. Lub hwjchim ci ntsa iab muab tag nrho OEM thiab ODM cov kev pabcuam: kev tsim pwm pwm (25-35 hnub ua haujlwm rau txhuas qauv pwm), kev cai xim nrog RAL lossis Pantone txuam, logo engraving lossis daim ntawv lo luam ntawv, thiab ntim cov khw muag khoom. Standard catalog MOQ: 100 pcs. Kev cai pwm xaj: 500 pcs yam tsawg kawg nkaus. Cov qauv dawb ntawm 1-5 units muaj rau cov neeg yuav khoom tsim nyog B2B. Xa koj daim duab kos lossis daim ntawv qhia tshwj xeeb rau sales@gloryoptics.com - pawg neeg tsim khoom teb hauv 48 teev.

Txog Tus Sau

Phau ntawv qhia no tau sau los ntawm engineering thiab khoom pab neeg ntawmNingbo Glory Optical Communication Co., Ltd.- ib lub chaw tsim khoom fiber ntau optic raws li nyob rau hauv Ningbo, Suav teb, nrhiav tau nyob rau hauv 2009. Lub hwjchim ci ntsa iab ua kom muaj ntau yam fiber ntau txiav thawv, splice kaw, fiber ntau optic cables, thaj qaum, thiab PLC splitters. Cov khoom xa tuaj rau 60+ lub teb chaws. Lub Hoobkas tuav ISO 9001: 2015 ntawv pov thawj thiab tsim ntau tshaj 5 lab FTB units hauv ib xyoos thoob plaws 30+ cov kab ntau lawm.

Rau cov khoom specs, kuaj dawb, OEM nug, lossis cov lus nug txog kev ua haujlwm ntawm koj qhov project tshwj xeeb:sales@gloryoptics.com| WhatsApp: +86 138 5833 6450 |gloryoptics.com

Cov qauv siv nyob rau hauv kab lus no:IEC 60529, IEC 61073-1, IEC 61300-3-4, IEC 61300-3-6, IEC 61300-3-35, IEC 61280-4-1, IEC 61280-4-2, IEC 61280-4-2, IEC 60068-2-11, IEC 60068-2-14, IEC 60793-2-50, ITU-T G.657, ITU-T L.37, TIA-568.3-E, TIA-606-C. Tag nrho cov ntaub ntawv ua tau zoo yog nyob ntawm Glory Hoobkas cov ntaub ntawv xeem thiab cov ntaub ntawv qhia txog kev xa tawm tam sim no txij li lub Peb Hlis 2026.

Xa kev nug