Ntawm nplooj ntawv no
- Teb ceev: Yuav ua li cas cov neeg yuav khoom kuaj ua ntej?
- Daim Ntawv Tshaj Qhia Kev Xeem Ua Dab Tsi (thiab Nws Tsis Yog)
- Split Ratio thiab Vim Li Cas Nws Hloov Qhov Koj Yuav Tsum Saib Xyuas
- Yuav Ua Li Cas Nyeem PLC Splitter Insertion Poob
- PLC Splitter Poob Daim Ntawv Qhia: Kev Siv Ntau Yam, Tsis Yog Tus Qauv Txais
- PLC splitter poob xam: Tshawb xyuas txhua qhov chaw nres nkoj
- Uniformity: Tus naj npawb ntau tus neeg yuav khoom hla
- Connector thiab Package Configuration: Daim Ntawv Qhia Yuav Tsum Tau Li Cas
- Qauv PLC Splitter Test Report Breakdown
- Cov chij liab ua ntej pom zoo ib qho PLC Splitter Order
- Tus neeg yuav khoom kos npe ua ntej xa khoom xa tuaj
- Piv txwv li: Tshuaj xyuas 1 × 32 PLC Splitter Test Report
- FAQ
Teb ceev: Yuav ua li cas cov neeg yuav khoom kuaj ua ntej?
Ua ntej txhua yam, paub meej tias daim ntawv tshaj tawm yeej sib haum rau koj qhov kev txiav txim. Xyuas covkhoom qauv, faib piv, connector hom, kuaj wavelengths, rau -port insertion poob, tus naj npawb, batch naj npawbthiabxeem hnub. Yim daim teb no qhia koj seb cov ntaub ntawv puas tuaj yeem taug qab mus rau ib qho kev thauj khoom tshwj xeeb - lossis rov ua dua los ntawm lwm txoj haujlwm.
Feem ntau cov neeg yuav khoom yuam kev yog nyeem ntawv xwbnruab nrab qhov poob. Qhov nruab nrab huv si tuaj yeem npog ib lossis ob qhov chaw tsis muaj zog. Ib txwm saib ntawmphem tshaj tawm qhov chaw nres nkoj tus nqi, vim hais tias nyob rau hauv lub tshav pob uas chaw nres nkoj txhais lub feem ntau marginal teeb liab txoj kev koj network yuav nqa. PLC splitter poob cov ntsiab lus uas qhia tau hais tias tsuas yog qhov nruab nrab - uas tsis muaj rau -chaw nres nkoj cov ntaub ntawv - tsis txaus los pom zoo ib qho kev txiav txim ntau.
Daim Ntawv Tshaj Qhia Kev Xeem Ua Dab Tsi (thiab Nws Tsis Yog)
Ib daim ntawv tshaj tawm kev sim ntawm lub Hoobkas qhia tau hais tias cov ntsuas ntsuas tau nyob hauv cov lus qhia ua ntej tawm hauv cov kab ntau lawm. Rau fiber ntau optic PLC splitter, uas txhais tau hais tias qhov tseeb qhov kev poob qhov tseem ceeb ntawm qhov cuam tshuam wavelengths, qhov zoo tshaj plaws nrog kev sib xws, rov poob thiab PDL, tag nrho khi rau cov ntaub ntawv traceable batch.
Txhua tus neeg xa khoom cov ntaub ntawv zoo sib xws; ntsuas batch cov ntaub ntawv tsis. Daim ntawv tshaj tawm tso cai rau koj los sib piv cov neeg muag khoom ntawm lawv qhov chaw nres nkoj nruj npaum li cas- rau- qhov chaw nres nkoj kis tau tiag tiag, txawm tias lawv sim ntawm ob lub qhov rais wavelength, thiab seb lawv cov kev txwv dhau / tsis ua raws li qhov lawv tau hais. Ob lub PLC optical splitter cov neeg muab khoom tuaj yeem muab qhov kev poob zoo ib yam ntawm daim ntawv tsis tau xa cov khoom sib txawv heev - qib sib xws.
Daim ntawv xeem ua li castsis yogua: nws tsis lees paub cov kab tiav cog. Nws ua pov thawj ua ntej - cov khoom xa tuaj xwb. Tom qab kev xa tawm koj tseem txheeb xyuas cov kev txuas nrog OTDR thiab lub ntsuas hluav taws xob kho qhov muag, thiab koj tseem tshawb xyuas qhov txuas kawg - ntsej muag thaum tuaj txog. Daim ntawv tshaj tawm txo cov kev pheej hmoo tuaj; nws tsis hloov daim ntawv pov thawj.
Daim ntawv tshaj tawm xeem, datasheet thiab Telcordia kev tsim nyog yog peb yam sib txawv.Daim ntawv teev cov ntaub ntawv yog tus neeg muag khoom tau tshaj tawm cov lus qhia tshwj xeeb - tsis muaj cov ntaub ntawv ntsuas rau koj cov units tshwj xeeb. Daim ntawv tshaj tawm kev xeem lub Hoobkas yog cov pov thawj ntsuas rau cov khoom xa tuaj. Kev ntseeg tau cov qauv xws liTelcordia GR-1209 CovthiabQauv: GR-1221rau passive optical Cheebtsam npog cov khoom lag luam-tsev neeg kev tsim nyog thiab ib puag ncig aging tests - tsis yog rau - cov ntaub ntawv xa khoom batch. Tus neeg muag khoom tuaj yeem tuav cov ntaub ntawv tsim nyog tau txais txiaj ntsig thiab tseem xa cov khoom lag luam marginal. Nug ob leeg; kho lawv raws li kev ua haujlwm sib txawv. Rau cov ntsiab lus parameter,ITU-T G.671ntawm optical tivthaiv cov yam ntxwv kis tau tus mob yog ib qho tseem ceeb hauv nruab nrab.
Split Ratio thiab Vim Li Cas Nws Hloov Qhov Koj Yuav Tsum Saib Xyuas
Qhov siab dua qhov kev suav suav, qhov siab dua qhov kev tso tawm thiab qhov dav dua qhov chaw nres nkoj muaj peev xwm - mus rau -port variation. Ib qho 1 × 32 PLC splitter faib cov tswv yim tawm tswv yim hla 32 cov khoom tawm, yog li daim ntawv tshaj tawm qhia tsuas yog qhov nruab nrab zais raws nraim cov ntaub ntawv koj xav tau tshaj plaws. Rau feem ntau FTTH bulk xaj ntawm qhov sib faib no, ib - cov ntaub ntawv chaw nres nkoj yog cov hauv paus uas xav tau hauv cov ntaub ntawv xa khoom - cov ntsiab lus nruab nrab ntawm nws tus kheej tsis txaus rau kev lees txais cov khoom nkag.
Tsawg piv tau yooj yim dua, tsis zam. Ib qho 1 × 8 PLC splitter lossis 1 × 16 PLC splitter tseem tuaj yeem xa cov chaw nres nkoj tsis zoo, qhov sib txuas tsis sib haum lossis tsis muaj wavelength - tib daim teb siv, nrog tsawg zog rau ib qhov chaw nres nkoj. Cov neeg yuav khoom npaj sib xyaw ODN architectures tuaj yeem hla - txheeb xyuas cov kev xav tau sib cais tawm tsam ib qhoFTTH network tsim thiab ODN architecture qhiakom paub meej tias tus lej twg nyob qhov twg hauv lub network.
Yuav Ua Li Cas Nyeem PLC Splitter Insertion Poob
PLC splitter insertion poob yog lub zog kho qhov muag poob ntawm cov tswv yim thiab qhov chaw tso zis tso zis. Nyob rau hauv daim ntawv ntsuam xyuas nws yuav tsum tshwm sim raws li qhov ntsuas tus nqi rautxhuatso zis chaw nres nkoj, tsis yog ib lub cuab yeej - cov ntsiab lus theem:
Qhov nruab nrab qhia koj li cas cov batch zoo li ntawm daim ntawv. Covphem tshaj -port insertion poobqhia koj txog qhov kev pheej hmoo tiag tiag, vim tias lub network feem ntau cov neeg siv khoom lag luam poob qis zaum tom qab cov zis tsis muaj zog. Daim ntawv tshaj tawm nrog qhov nruab nrab txaus nyiam tab sis ob qhov siab -cov chaw nres nkoj poob tseem tuaj yeem ua rau muaj teeb meem hauv thaj chaw ntawm cov kev tshwj xeeb. CovFOA kev taw qhia ntawm kev sib cais thiab kev kuaj sib txuastxhawb nqa qhov xav tau los ntsuas txhua qhov kev faib tawm tawm thiab nkag siab qhov chaw nres nkoj - mus rau - chaw nres nkoj variation, es tsis yog cia siab rau ntawm daim duab qhia.
Saib rau ib -chaw nres nkoj cov ntaub ntawv uas zoo nkaus li tsis sib xws: qhov tseem ceeb uas txhua tus nyeem zoo ib yam rau ob qhov chaw lej, cov lej poob uas tsis muaj qhov ntsuas qhov ntev, lossis qhov chaw nres nkoj phem tshaj zaum ze ntawm qhov chaw hla dhau / poob tsis muaj cov npoo. Ib qho ntawm cov ntawv tso cai no ua raws li - ua ntej tso tawm batch.
PLC Splitter Poob Daim Ntawv Qhia: Kev Siv Ntau Yam, Tsis Yog Tus Qauv Txais
Siv daim ntawv poob raws li kev txheeb xyuas kev noj qab haus huv - kom paub meej tias cov xov tooj tau tshaj tawm yog lub cev tsim nyog rau qhov sib cais, tsis yog hloov pauv rau qhov kev pom zoo lees txais.
Cov txiaj ntsig no yog cov kev siv dav dav pom hauv cov ntaub ntawv xa khoom. Qhov ntsuas qhov tseeb yuav txawv nyob ntawm qhov sib piv, hom txuas, hom pob, kuaj wavelength, pigtail ntev thiab tus neeg xa khoom specification. Kev lees txais zaum kawg yuav tsum ua raws li daim ntawv teev cov ntaub ntawv hais thiab pom zoo qhov project specification - tsis yog daim ntawv no ib leeg. Siv nws tsuas yog ua kev kuaj xyuas kom huv ua ntej muab piv rau daim ntawv qhia tseeb tawm tsam cov kev pom zoo.
Daim ntawv hla / tsis txwv ntawm daim ntawv tshaj tawm yuav tsum sib phim qhov siab tshaj plaws tau teev tseg hauv cov ntaub ntawv koj tau hais. Yog tias daim ntawv tshaj tawm qhov pib poob qis, cov ntaub ntawv ntsiag to rov hais dua qhov kev lees txais ntawm tus neeg xa khoom nyiam. Qhov sib txawv ntawd ib leeg yog lub hauv paus rau ncua kev xa khoom.

PLC splitter poob xam: Tshawb xyuas txhua qhov chaw nres nkoj
PLC splitter poob xam yog ncaj nraim. Yog hais tias lub hwj chim input yog 0 dBm thiab ib qho chaw tso zis nyeem −16.8 dBm, qhov chaw nres nkoj qhov kev poob qis yog 16.8 dB. Daim ntawv tshaj tawm yuav tsum cia koj rov tsim dua qhov no rau txhua qhov chaw nres nkoj hauv lub rooj. Tshaj tawm tias cov qauv "ob peb tus neeg sawv cev chaw nres nkoj" ntawm qhov siab - suav cov cuab yeej tawm ntawm qhov tsis tau lees paub - tsis txaus rau kev pom zoo xa khoom nruj ntawm siab - suav cov khoom siv.
Raws li - qhov chaw nres nkoj poob kuj yog qhov kev nkag ncaj qha rau koj cov peev nyiaj txuas. Paub qhov phem tshaj -chaw nres nkoj tus nqi tso cai rau koj kom paub meej tias lub splitter haum rau ODN fais fab nyiaj txiag npaj ua ntej kev teeb tsa. Cov neeg yuav khoom tswj qhov projectFTTH poob nyiaj txiagtuaj yeem siv qhov phem tshaj -chaw nres nkoj daim duab ncaj qha rau hauv kev suav, es tsis yog qhov zoo tshaj qhov nruab nrab.
Uniformity: Tus naj npawb ntau tus neeg yuav khoom hla
Uniformity piav qhia tias lub zog sib npaug sib faib thoob plaws txhua qhov chaw tso zis:
Ib pawg uas tau txais qhov nruab nrab tab sis qhov tsis zoo sib xws tseem tuaj yeem tsim cov neeg siv khoom tsis sib xws hauv qib - qee qhov poob ze rau sab saum toj ntawm cov peev nyiaj, lwm tus nyob ze ntawm cov npoo. Nws yog ib qho teeb meem txij nkawm uas feem ntau ntog tsuas yog tom qab xa mus. Yog tias daim ntawv tshaj tawm tsis muaj cov ntaub ntawv ntawm ib qho ntawm -chaw nres nkoj, koj tsis tuaj yeem suav qhov tsis sib xws - uas yog nws tus kheej kos npe rau daim ntawv tsis tiav rau ntau qhov kev lees txais.
Connector thiab Package Configuration: Daim Ntawv Qhia Yuav Tsum Tau Li Cas
Connector hom, rov poob thiab xaus -fim tshuaj ntsuam
A PLC splitter nrog connectorcov nkoj txiav tawm - feem ntau yog SC/APC PLC splitter lossis SC/UPC version. Lub PLC splitter yam tsis muaj qhov txuas yog muab los ua fiber ntau rau kev sib tshuam. Daim ntawv tshaj tawm hais txog hom connector yuav tsum ua raws li koj qhov kev txiav txim raws nraim, suav nrog lub kaum sab xis polishing (APC vs UPC) thiab pigtail ntev. Yog tias qhov kev teeb tsa tau teev tseg tsis sib haum rau qhov kev yuav khoom, rov qab ua ntej xa khoom xa tuaj - thiab xyuas kom meej tias muaj kev cuam tshuamfiber ntau optic pigtailslos yogpatch kabxaj ib sab ntawm cov splitters yog zoo ib yam nrog tib configuration.
Connector polish drives xav txog. APC kawg-ntsej muag xa rov qab poob ntau dua li UPC, yog li cov ntaub ntawv poob rov qab tsuas yog ua rau kev nkag siab thaum nyeem ib sab ntawm cov khoom txuas kom raug.IEC 61300-3-35: Covtxhais cov txheej txheem rau connector kawg -fim kev soj ntsuam, npog cov kab mob, khawb thiab tsis xws luag. Daim ntawv tshaj tawm kev xeem lub Hoobkas tsis hloov qhov kawg -fim tshuaj xyuas tom qab tuaj txog; uas yog ib kauj ruam cais hauv QC tuaj.
Rov qab poob yog nyob rau hauv daim ntawv qhia rau tej connectorized fiber optic PLC splitter. Ib qho APC nrog cov tsis muaj zog rov qab cov nuj nqis taw qhia qhov teeb meem polishing lossis kev sib dhos tsim nyog ua ntej cov khoom tawm mus. PDL (polarization dependent poob) tsis tshua muaj thawj qhov tseem ceeb rau tus qauv FTTH kev yuav khoom, tab sis daim ntawv qhia meej yuav tsum suav nrog nws. Yog tias tus neeg muag khoom cov ntaub ntawv tsis muaj qhov rov qab poob, tsis muaj PDL thiab tsis muaj cov ntaub ntawv sib xws, kho nws kom tsawg - ua tiav es tsis yog "dhau."
Pob hom: liab qab fiber ntau, blockless, ABS, cassette thiab LGX
Seb lub tsev yog liab qab fiber ntau PLC splitter, blockless PLC splitter, ABS PLC splitter,Cassette PLC splitterlos yog LGX PLC splitter module, hom pob thiab qauv code yuav tsum muaj npe qhia meej ntawm daim ntawv tshaj tawm. Ib lub cassette lossis LGX module yog ib lub rooj sib dhos nrog cov chaw txuas txuas; nws daim ntawv tshaj tawm yuav tsum siv cov qauv qauv thiab chaw nres nkoj teeb tsa. Ib daim ntawv qhia cov khoom siv fiber ntau npog cov nqaij nyoos splitter thiab pigtails nkaus xwb. Tsis meej pem ob qho tib si tsim kev cia siab tsis ncaj ncees ntawm kev sib txuas tsis zoo, rov qab poob, qhov ntev thiab tuav.
Rau ib qho kev txiav txim ntau, tus qauv, pob hom, pigtail ntev thiab connector configuration ntawm daim ntawv tshaj tawm yuav tsum ua raws li kev yuav khoom kab los ntawm kab. Lub generic "PLC splitter, 1 × 32" uas tsis muaj pob lossis qauv code tsis tuaj yeem taug qab txaus rau kev lees paub.
Qauv PLC Splitter Test Report Breakdown
Siv cov lus hauv qab no los soj ntsuam txhua ntu ntawm cov ntawv tshaj tawm cov khoom siv ua haujlwm.
| Qhia Tshooj | Dab tsi cov neeg yuav khoom yuav tsum kuaj xyuas | Tus chij liab |
|---|---|---|
| Header ntaub ntawv | Cov qauv khoom, cais piv, SN, batch naj npawb, xeem hnub | Tsis muaj batch/SN; generic piav qhia tsis muaj qauv code |
| Cov ntaub ntawv kho qhov muag - qhov poob | Ib -port IL ntawm 1310 nm thiab 1550 nm; 1490 nm qhov twg teev rau GPON- tshwj xeeb txais | Nruab nrab nkaus xwb; wavelength tsis tau teev; tsawg cov chaw nres nkoj teev tshaj qhov sib cais |
| Kev tsis sib xws | Siab tshaj IL rho tawm qis tshaj IL hla txhua qhov chaw tso zis | Tsis tau hais; tsis tuaj yeem suav vim yog ib qho - cov ntaub ntawv chaw nres nkoj tsis tuaj |
| Rov qab poob | Yuav tsum tau rau cov khoom connectorized; wavelength - tshwj xeeb | Tsis nyob ntawm APC qhov chaw; tus nqi qis dua datasheet yam tsawg kawg nkaus |
| PDL | Qhov taw qhia zoo; thov kom nruj dua kev yuav khoom | Tsis tuaj yeem ua tiav ntawm qib siab dua - qib OEM xaj |
| Connector configuration | SC/APC, SC/UPC, LC/APC lossis liab qab fiber ntau - tau hais meej meej | Daim teb; configuration contradict lub PO |
| Hom pob | Liab qab fiber ntau, blockless, ABS lub thawv, cassette, LGX module | Cov lus piav qhia dav tsis txuas rau tus lej qauv |
| QC kev pom zoo | Tus neeg teb xov tooj lub npe, kos npe lossis lub thwj cim, hla / tsis ua haujlwm | Tsis muaj npe; Kev lees txais txwv txawv ntawm daim ntawv teev cov ntaub ntawv |
| Khoom siv / calibration | Meter qauv thiab calibration hnub | Tsis nyob ntawm nruj -kev txiav txim zoo - thov cais yog tias xav tau |
Cov chij liab ua ntej pom zoo ib qho PLC Splitter Order
Tsis muaj serial tooj los yog batch reference.Ib daim ntawv tshaj tawm yam tsis muaj ib pawg lossis cov ntaub ntawv siv tsis tuaj yeem khi rau cov units hauv lub thawv. Rau kev pom zoo rau kev xa khoom ntau, qhov sib txawv ntawm kev lav phib xaub yog qhov teeb meem loj - tsis yog kev cai.
Qhov nruab nrab poob nkaus xwb, tsis muaj rau -port qhov tseem ceeb.Yog tias daim ntawv qhia ib tus lej thiab tsis muaj qhov chaw nres nkoj - theem cov lus, koj tsis tuaj yeem txheeb xyuas qhov chaw nres nkoj phem tshaj plaws lossis suav qhov tsis sib xws. Thov ua kom tiav rau - cov ntaub ntawv chaw nres nkoj ua ntej tso qhov kev txiav txim.
Cov txiaj ntsig zoo ib yam thoob plaws ntau qhov chaw nres nkoj.Kev ntsuas tiag tiag sib txawv me ntsis vim qhov ntsuas suab nrov thiab qhov chaw nres nkoj sib txawv. Tib qhov kev poob qis tus nqi rov qab hla ntau qhov chaw nres nkoj mus rau tib qhov chaw decimal yuav qhia tau tias cov ntaub ntawv theej lossis qhov chaw khaws ntaub ntawv tsis yog kev sim tiag. Tuav lub batch kom txog thaum tus neeg xa khoom tuaj yeem muab cov ntaub ntawv ntsuas raw.
Nthuav lossis tsis meej wavelength.Kev poob yam tsis tau hais txog lub wavelength tsis muaj qab hau. Feem ntau cov qauv qhia npog 1310 nm thiab 1550 nm. Rau GPON-kev lees paub tshwj xeeb, 1490 nm tuaj yeem thov cais - qhov xav tau qhov ntsuas wavelengths yuav tsum tau pom zoo nrog tus neeg xa khoom ua ntej xa khoom.
Qhia pass/fail limit looser dua datasheet.Yog tias qhov kev lees paub ntawm daim ntawv tshaj tawm siab dua qhov siab tshaj plaws tau teev tseg hauv daim ntawv teev cov ntaub ntawv koj tau hais, cov ntaub ntawv tau pom zoo cov chav nyob hauv cov ntaub ntawv yuav tsis lees paub. Nug ib daim ntawv piav qhia ua ntej cov khoom xa tuaj.
QC mini-scenarios
Cov xwm txheej no tshwm sim tsis tu ncua nyob rau hauv ua ntej -cov ntaub ntawv xa khoom tuaj xyuas thiab kev tshuaj xyuas tuaj rau FTTH cov khoom.
Scenario 1 - Nthuav qhia txog kev teeb tsa.PO qhia txog 1 × 32 SC / APC cassette PLC splitter. Daim ntawv tshaj tawm kev xeem hais tias tsuas yog "1 × 32 PLC splitter" uas tsis muaj hom txuas, tsis muaj lub kaum sab xis, tsis muaj hom pob.Kev nqis tes ua: thov ib daim ntawv qhia raug kho uas npe tag nrho cov teeb tsa. Tsis txhob tso cov khoom xa tuaj kom txog thaum daim ntawv tshaj tawm tau sib haum nrog PO kab.
Scenario 2 - Cov ntaub ntawv chaw nres nkoj tsis tiav.Daim ntawv tshaj tawm 1 × 32 PLC splitter cov ntawv teev npe poob rau 8 qhov chaw nres nkoj nkaus xwb, nrog rau kev ceeb toom tias lawv yog "tus qauv piv txwv."Kev nqis tes ua: thov ua kom tiav rau -chaw nres nkoj cov ntaub ntawv rau tag nrho 32 cov zis. Ib qho piv txwv tsis txaus rau kev lees txais ntau ntawm cov khoom siv siab - suav.
Scenario 3 - Mismatched pass/fail threshold.Cov ntaub ntawv xa khoom uas koj tau hais tawm hais tias qhov kev nkag siab siab tshaj plaws ntawm 17.0 dB. Daim ntawv tshaj tawm kev xeem tau hais dhau qhov txwv qhia tau tias 17.5 dB.Kev Ua Haujlwm: txheeb xyuas qhov pib tiv thaiv cov ntaub ntawv sau tseg. Yog tias cov kev txwv tsis sib xws, daim ntawv tshaj tawm pom zoo cov chav nyob hauv cov ntaub ntawv yuav tsis lees paub. Tuav cov khoom xa tuaj thiab thov sau ntawv qhia meej.
Tus neeg yuav khoom kos npe ua ntej xa khoom xa tuaj
Siv qhov no ua ntej - lub rooj txais khoom xa tuaj. Ib daim teb uas ploj lawm yog vim li cas thov kom kho cov ntaub ntawv, tsis pom zoo thiab ua mus.
| Yam khoom | Vim Li Cas Nws Tseem Ceeb | Tus neeg yuav khoom Action |
|---|---|---|
| Khoom qauv | Ties qhia rau qhov txiav txim | Match rau PO kab khoom |
| Split ratio | Paub meej tias cov cuab yeej raug | Tshawb xyuas tiv thaiv kev txiav txim |
| Hom Connector | Tsav IL thiab rov qab poob | Paub meej tias APC / UPC / liab qab fiber ntau |
| Hom pob | Muaj feem xyuam rau cov ntaub ntawv thiab tuav | Ua ke nrog pob xaj |
| Fiber hom | Pom zoo G.657 / G.652 qib | Txheeb xyuas qhov project spec |
| Kuaj wavelengths | Poob yog wavelength -dependent | Cia siab tias 1310/1550 nm raws li tus qauv; 1490 nm yuav raug thov qhov twg GPON- tshwj xeeb txais yuav tsum tau |
| Raws li -port insertion poob | Qhia qhov chaw nres nkoj phem tshaj plaws | Nyeem txhua qhov chaw nres nkoj, tsis yog qhov nruab nrab |
| Kev tsis sib xws | Qhia qhov sib xws ntawm qhov chaw nres nkoj | Xam siab tshaj - qis tshaj |
| Rov qab poob | Indicator connector polish mob | Cia siab rau cov khoom sib txuas |
| PDL | Siab dua -qib qhov ntsuas qhov zoo | Thov yog tias tsis tuaj ntawm OEM lossis kev txiav txim nruj |
| Serial tooj | Unit -theem accountability | Paub meej tias tam sim no |
| Batch naj npawb | Cov ntawv txuas qhia rau cov thawv xa khoom | Paub meej tias tam sim no |
| Hnub xeem | Cov ntaub ntawv qhia tau tam sim no, tsis rov siv dua | Txheeb xyuas tsis ntev los no |
| QC kos npe / stamp | Tus neeg khiav dej num accountability | Pom zoo kos npe los yog stamped |
| Pass/fail limit | Txhais qhov kev lees txais | Ua pov thawj tiv thaiv cov ntaub ntawv sau tseg |
Rau qhov kev txiav txim 1 × 32 PLC splitter, thov tag nrho 32 ib -chaw nres nkoj qhov tseem ceeb, paub meej tias cov txiaj ntsig zoo sib xws yog nyob rau hauv qhov kev txwv pom zoo, thiab ntsuas qhov phem tshaj plaws ntawm daim duab ntawm tus kheej tawm tsam qhov kev lees paub. Khaws daim ntawv qhia kos npe ua ke nrog batch thiab serial references raws li ib feem ntawm kojfiber ntau faib lub thawv thiab NAP lub thawvcov ntaub ntawv xa mus.
Hauv kev tshuaj xyuas cov ntaub ntawv xa khoom thiab ua ntej -kev xa khoom QC kev sib txuas lus rau FTTH cov khoom, cov ntawv tshaj tawm kev xeem uas muaj txiaj ntsig zoo tshaj plaws tsis tshua muaj cov uas qhia tsuas yog qhov poob qis tshaj qhov nruab nrab. Lawv yog cov uas muaj feem cuam tshuam rau -chaw nres nkoj qhov tseem ceeb, wavelength- tshwj xeeb nyeem, serial tooj, batch reference, connector configuration thiab pob hom nrog ib tug kom meej meej pass/fail threshold - thiab txuas tag nrho cov ntawm cov khoom xa tuaj. Rau OEM xaj kev tshuaj xyuas thiab kev tshuaj xyuas tuaj, qhov nruab nrab me ntsis siab dua nrog tag nrho, cov ntaub ntawv taug qab tau yooj yim dua rau kev pom zoo dua li qhov tsis muaj tseeb - saib qhov nruab nrab uas tsis muaj teeb tsa, tsis muaj kev siv cov khoom siv thiab tsis muaj kev lees paub. Cov ntaub ntawv tus nqi yog nyob rau hauv kev sib txuas, tsis yog tus lej xov tooj.
Piv txwv li: Tshuaj xyuas 1 × 32 PLC Splitter Test Report
Cov hauv qab no yog qhov yooj yim, piav qhia kev tshuaj xyuas - tsis yog cov ntaub ntawv tus neeg siv khoom tiag.
Kauj Ruam 1 - Muab cov qauv rau kev yuav khoom.Paub meej tias tus qauv code, hom pob thiab kev teeb tsa txuas ntawm daim ntawv tshaj tawm sib raug rau PO raws nraim. Qhov tsis sib haum ntawm no nres qhov kev tshuaj xyuas ua ntej nws pib.
Kauj Ruam 2 - Xyuas kom tseeb tias tag nrho 32 qhov chaw tso zis tau teev tseg.Nyeem txhua qhov ib -port insertion poob tus nqi, tsis yog cov ntsiab lus. Daim ntawv tshaj tawm 1 × 32 uas teev tsuas yog cov chaw nres nkoj me me xwb tsis tiav rau kev lees txais ntau.
Kauj ruam 3 - Txheeb xyuas qhov phem tshaj - chaw nres nkoj tus nqi thiab muab piv rau qhov siab tshaj plaws tau pom zoo.Yog tias qhov chaw nres nkoj qhov tseem ceeb khiav ntawm 16.45 dB txog 16.95 dB, daim duab los xyuas yog 16.95 dB - tsis yog qhov nruab nrab. Kuj paub meej tias daim ntawv tshaj tawm tau hais dhau qhov kev txwv hla / tsis ua haujlwm sib raug rau cov ntaub ntawv siab tshaj plaws. Yog tias daim ntawv tshaj tawm pom zoo ntawm 17.5 dB tab sis cov ntaub ntawv sau tseg hais tias 17.2 dB, daws qhov tsis sib xws ua ntej cov khoom xa tuaj.
Kauj Ruam 4 - Xam qhov sib xws.16.95 dB - 16.45 dB=0.50 dB. Muab piv rau qhov pom zoo uniformity specification.
Kauj ruam 5 - Paub meej tias connector thiab pob zoo ib yam.Txheeb xyuas qhov sib txuas polish, pigtail ntev thiab pob hom tshwm sim ntawm daim ntawv tshaj tawm thiab sib haum rau kev yuav khoom. Muab cov ntaub ntawv kos npe nrog batch thiab serial references raws li ib feem ntawm cov ntaub ntawv xa khoom xa tuaj.
| Tshawb xyuas | Yam Koj Paub | Daim duab qhia | Kev txiav txim siab |
|---|---|---|---|
| Qauv sib phim | Report vs PO | Sib tw - SC/APC cassette | Ua mus |
| Rau -port data | 32 tus nqi tam sim no | Tag nrho 32 teev | Ua mus |
| Qhov phem tshaj -port vs pom zoo txwv | Siab tshaj IL vs qhov lees txais | 16.95 dB vs 17.2 dB txwv | Hauv qhov txwv |
| Tshaj tawm txwv vs datasheet | Pass / poob qhov pib sib xws | Ob lub xeev 17.2 dB max | Zoo ib yam |
| Kev tsis sib xws | Siab tshaj - qis tshaj | 0.50 dB - nyob rau hauv spec | Ua mus |
| Connector / pob | Configuration alignment | SC/APC cassette raws li kev txiav txim | Zoo ib yam |
| Kev hu zaum kawg | Txhua qhov kev kuaj pom tseeb | - | Pom zoo |
Yog tias qhov chaw nres nkoj phem tshaj dhau qhov kev pom zoo, qhov kev teeb tsa txuas txuas tsis ua raws li PO, rau - cov ntaub ntawv chaw nres nkoj ploj lawm, lossis cov ntaub ntawv tshaj tawm tsis sib haum rau daim ntawv teev cov ntaub ntawv, qhov kev hu raug yogtuav(thov kom kho cov ntaub ntawv thiab sau kom meej meej) lossistsis lees paub(rov qab rau re-test), tsis pom zoo.
FAQ
-
Q: Kuv puas tuaj yeem pom zoo ib pawg nrog tsuas yog qhov nruab nrab qhov poob?
A: Tsis yog rau kev tshuaj xyuas nruj heev. Qhov nruab nrab zais qhov chaw nres nkoj phem tshaj plaws, ua rau kev suav tsis sib xws tsis tuaj yeem, thiab tsis muaj kev xa khoom xa tuaj -theem traceability. Rau FTTH kev txiav txim ntau, ua kom tiav ib - cov ntaub ntawv chaw nres nkoj yuav tsum tau thov ua ntej qhov kev txiav txim raug tso tawm.
Q: Puas yog daim ntawv qhia 1 × 32 PLC splitter qhia tag nrho 32 qhov chaw tso zis?
A: Yog. Ib daim ntawv tshaj tawm 1 × 32 yuav tsum sau cov ntawv poob rau tag nrho 32 qhov chaw tso zis. "Sawv cev cov qauv" los ntawm ib lub subset tsis txaus rau bulk txais ntawm ib tug siab - suav ntaus ntawv - cov chaw nres nkoj tsis ntsuas tseem tsis tau lees paub.
Q: Kuv yuav ua li cas yog tias daim ntawv tshaj tawm txuas yam tsis phim PO?
A: Tuav cov khoom xa tuaj thiab thov cov ntaub ntawv kho kom raug hauv kev sau ntawv. Daim ntawv qhia txog fiber ntau PLC splitter yuav tsum tsis txhob siv los pom zoo rau cov khoom sib txuas - connector poob thiab rov qab poob tsis tuaj ntawm cov ntaub ntawv, ua rau cov ntaub ntawv tsis tsim nyog rau qhov kev teeb tsa ntawd.
Q: Puas yog daim ntawv qhia batch txaus rau kev txiav txim ntau?
A: Ib daim ntawv qhia txog qib - qib tuaj yeem lees txais rau cov khoom lag luam catalog yog tias nws suav nrog rau - cov ntaub ntawv chaw nres nkoj, ntsuas wavelengths, kev txwv hla / tsis ua haujlwm thiab cov ntaub ntawv batch uas tuaj yeem siv tau. Rau siab - suav lossis tseem ceeb txiav txim - 1 × 32, 1 × 64 - ib -unit reports yog ib txoj hauj lwm muaj zog.
Q: Puas yog txhua qhov PLC splitter xa khoom xa tuaj suav nrog daim ntawv tshaj tawm?
A: Rau kev yuav khoom ntau, yog. Daim ntawv tshaj tawm cov khoom muag yuav tsum nrog rau txhua qhov kev xa khoom xa tuaj kom qhov kev ua tau zoo ntawm qhov muag, kev teeb tsa thiab kev taug qab tuaj yeem raug txheeb xyuas tau thaum tuaj xyuas - tsis xav tias.
Q: Dab tsi yog qhov lees paub qhov poob rau 1 × 32 PLC splitter?
A: Ib qho kev siv ntau yam yog nyob ib ncig ntawm 16.5-17.2 dB, tab sis qhov kev lees txais tiag tiag yuav tsum ua raws li koj cov ntaub ntawv xa khoom thiab pom zoo qhov project specification. Hom kev sib txuas, hom pob thiab qhov ntev pigtail tag nrho cuam tshuam rau qhov ntsuas kawg ntawm tus nqi - daim ntawv qhia dav dav yog qhov pib, tsis yog tus qauv lees paub.
Q: Vim li cas cov ntaub ntawv qhia 1310 nm, 1550 nm thiab qee zaum 1490 nm?
A: Insertion poob nws txawv nrog wavelength, yog li cov ntaub ntawv ntsuam xyuas ntawm cov kev khiav hauj lwm qhov rais. Cov ntaub ntawv tshaj tawm tus qauv feem ntau suav nrog 1310 nm thiab 1550 nm. Rau GPON-kev lees paub tshwj xeeb, cov neeg yuav khoom tuaj yeem thov 1490 nm vim tias nws yog qhov kev ua haujlwm qis qis hauv GPON systems. Qhov yuav tsum tau kuaj wavelengths yuav tsum tau pom zoo ua ntej ua zaub mov xa tuaj.
Q: Puas yog lub Hoobkas kuaj daim ntawv qhia tib yam li Telcordia daim ntawv pov thawj?
A: Tsis yog. Ib daim ntawv tshaj tawm kev xeem ntawm lub Hoobkas yog ntsuas cov ntaub ntawv rau ib qho khoom xa tuaj. Telcordia GR-1209/GR-1221 kev tsim nyog suav nrog kev ntseeg siab thiab kev sim ib puag ncig ntawm tsev neeg tsim khoom - tsis yog cov ntaub ntawv ntsuas ib qho khoom xa tuaj. Ob leeg muaj nqi; tsis yog hloov lwm tus.
Q: Puas yuav tsum muaj fiber ntau PLC splitter thiab lub connectorized PLC splitter siv tib daim ntawv qhia?
A: Tsis yog. Ob qhov kev teeb tsa sib txawv hauv qhov sib txuas poob, rov poob thiab xaus - cov ntaub ntawv ntsej muag. Txhua tus xav tau ib daim ntawv tshaj tawm qhia txog nws qhov kev sim ntsuas tiag tiag. Kev rov siv dua ib qho rau lwm qhov tsis tsim nyog rau kev tshuaj xyuas tuaj.
Q: Vim li cas lub Hoobkas tuaj yeem kuaj cov ntaub ntawv sib txawv los ntawm kev nyeem lub zog ntsuas hluav taws xob?
A: Ntau yam ua rau: kev ntsuas lub Hoobkas thiab thaj chaw siv cov kev siv sib txawv; connector mating ntawm installation ntxiv poob; cable khoov, splices thiab faib khoom kho vajtse qhia ntxiv attenuation. Daim ntawv tshaj tawm kev xeem lub Hoobkas npog cov splitter nyob rau hauv kev tswj xyuas - teb cov lus nyeem cuam tshuam txog qhov txuas txuas ua tiav.