MPO Fiber Patch Cord Solution

Sep 24, 2026

Tso lus

Yuav ua li cas tsim cov patching, polarity, breakout, kuaj thiab tsiv teb tsaws txoj kev nyob ib ncig ntawm ib tug high-density MPO qaum

Vim li cas MPO tej yaam num ua tsis tau txawm tias txhua feem zoo li raug

MPO cabling feem ntau yog qhia raws li zaj dab neeg ntom ntom: ib qho txuas txuas muaj ob peb fibers, lub Hoobkas txiav luv luv lub sijhawm teeb tsa, thiab lub khib nyiab tuaj yeem txhawb nqa ntau txoj hauv kev tshaj li qhov tsim tawm duplex. Tag nrho cov ntawd yog qhov tseeb, tab sis nws tsis yog qhov uas txiav txim siab seb qhov txuas tuaj txog thawj hnub.

Qhov nyuaj yog qhov sib cuam tshuam ntawm cov khoom. Ib qho MPO thaj qaum tuaj yeem yog hom fiber ntau, qhov ntev thiab cov xim zoo, tseem tseem ua tsis ncaj ncees rau cov channel vim tias qhov chaw nres nkoj xav tau cov fiber ntau suav, kev taw qhia tseem ceeb, pinned lossis unpinned connector, polish, lossis kab ntawv qhia. Lub cassette tuaj yeem ua tau zoo sib xws nrog lub chassis thiab tseem cuam tshuam tus khub tsis ncaj ncees lawm. Lub cev muaj peev xwm dhau lub Hoobkas kev sim poob thiab tseem raug ntsia rau hauv cov channel uas nws qhov kawg-rau-kawg polarity tsis tau txhais.

Tias yog vim li cas MPO fiber thaj qaum kev daws teeb meem yuav tsum tau tsim los ua ib txoj hauv kev los ntawm ib qho khoom siv kho qhov muag mus rau cov khoom tau txais, tsis yog raws li daim ntawv teev npe ntawm cov cables. Ob daim duab muab rau kab lus no muaj txiaj ntsig zoo vim tias lawv pom qhov system saib: modular chassis, trunks, adapter plates, modules thiab breakouts yog tag nrho cov seem ntawm tib passive channel. Cov seem uas ua raws li tig qhov system saib mus rau hauv kev tsim qauv thiab kev yuav khoom.

info-800-450

1. Dab tsi yog MPO fiber ntau thaj qaum kev daws teeb meem suav nrog

Cov kab lus MPO fiber ntau thaj qaum feem ntau siv dav heev. Nyob rau hauv ib qhov project center, tsawg kawg yog plaub qhov sib txawv passive sib dhos yuav siv tib MPO connector tsev neeg thaum ua hauj lwm sib txawv. Kev sib cais cov hauj lwm thaum ntxov ua rau BOM tswj tau yooj yim dua thiab cov phiaj xwm sim sau tau yooj yim dua.

info-800-450

Ib txoj hlua khi feem ntau yog lub Hoobkas luv luv-tawm kev sib dhos siv los txuas qhov chaw nres nkoj mus rau lub vaj huam sib luag, lossis ib qho MPO patching txoj hauj lwm mus rau lwm qhov. Lub cev pob txha yog cov pob txha caj qaum: nws khiav ntawm cov txee, kab lossis chaw faib khoom thiab feem ntau yog kho raws li qhov txuas mus tas li lossis ib nrab mus tas li. Ib qho kev sib cais los yog cov hlua khi hloov ib qho fiber ntau kawg rau hauv ob peb lub duplex lossis simplex ob txhais ceg. Ib lub cassette zaum hauv ib lub thawv ntim khoom thiab ua tib yam kev hloov pauv hauv qhov kev tiv thaiv, kev pabcuam tau zoo dua li hauv cov hlua xoob.

Thawj daim duab qhia qhia tag nrho plaub lub tswv yim ib zaug. Lub cev tsim cov pob txha loj heev. Adapter daim hlau khaws cia MPO-rau-MPO interface ntawm lub khib. Cassettes lossis modules txhais cov caj qaum rau hauv cov khoom siv qis dua. Cov rooj sib tham Fanout coj tib qhov kev txhais lus ncaj qha rau lub cuab yeej. Tsis muaj ib qho ntawm cov kev xaiv no tau zoo dua. Qhov kev xaiv yog nyob ntawm seb cov kws kho mob xav tau kev nkag mus li cas, qhov chaw nres nkoj yuav hloov pauv li cas thiab qhov twg cov khoom sib txuas ntawm lub transceiver tau nthuav tawm.

Cheebtsam Txoj hauj lwm tseem ceeb Hom interface Qhov twg nws haum
MPO daim kab xev Cov khoom siv luv luv lossis thaj-vaj huam sib luag txuas MPO<->MPO Direct parallel txuas; cross-connect patching
MPO lub cev Rov qab nruab nrab ntawm racks / aav MPO<->MPO, feem ntau ntau ceg Permanent structured cabling
MPO-rau-LC hlua Direct breakout MPO<->ntau LC QSFP breakout; kev hloov khoom siv
MPO cassette Kev tiv thaiv modular hloov MPO rov qab<->LC/CS pem hauv ntej High-density structured patching
MPO adapter vaj huam sib luag Presents tib lub interface MPO<->MPO los ntawm adapters Parallel-optics thaj teb

2. Pib nrog lub chaw nres nkoj nquag, tom qab ntawd ua haujlwm rov qab

Ib qho kev tsim MPO txhim khu kev qha pib nrog tus lej transceiver lossis ib qho kev pom zoo ntawm PMD. Pib nrog kev ceev ceev xws li 40G, 100G lossis 400G tsis txaus. Cov khoom siv kho qhov muag sib txawv ntawm tib tus nqi Ethernet tuaj yeem siv duplex LC, sib npaug MPO, wavelength multiplexing lossis ib hom kev sib txuas optics. Lub cable tsis paub cov ntaub ntawv tus nqi; nws tsuas paub lub cev interface, fiber ntau hom thiab txoj kab kev.

Rau txhua qhov kawg ntawm cov channel, sau cov khoom sib txuas uas nthuav tawm los ntawm cov khoom siv nquag, hom fiber ntau uas yuav tsum tau muaj, tus naj npawb ntawm cov khoom siv fiber ntau, kev xa tawm thiab tau txais txoj kab ntawm txoj kab, thiab seb lub receptacle yog pinned los yog unpinned. Yog hais tias lub transceiver siv MPO receptacle, xyuas cov chaw tsim tshuaj paus qhov tseem ceeb orientation thiab polish yuav tsum tau ib yam. Ntau qhov sib npaug ntawm cov khoom siv tsis siv lub cable ntawm cov khoom siv sab nraud vim tias cov khoom siv hluav taws xob muaj cov ntawv qhia pins, tab sis qhov ntawd yuav tsum tau kuaj xyuas qhov tseeb module es tsis xav tias yog tus cwj pwm.

Thaum ob lub ntsiab lus tseem ceeb paub, txiav txim siab seb cov txheej txheem passive yuav tsum nyob twj ywm MPO kawg lossis hloov mus rau cov khoom sib txuas. Ib qho kev txiav txim siab cais peb qhov kev tsim qauv qhia hauv daim duab 3: direct parallel patching, ib tug qauv MPO nraub qaum nrog modular panels, los yog ib tug breakout los ntawm ib tug mus txog qhovtwg interface mus rau ob peb duplex ports.

info-800-450

3. Nyeem daim duab hauv qab: qhov twg MPO txuag qhov chaw tshaj plaws

Daim duab thib ob tau muab los ze dua rau qhov kev pom zoo-cabling classic. Nws qhia tau hais tias duplex cov khoom siv chaw nres nkoj ntawm ob qho kawg, LC-rau-MPO hloov pauv nyob ze ntawm ntug, thiab muaj fiber ntau- suav MPO qaum hauv nruab nrab. Qhov kev teeb tsa no muaj txiaj ntsig zoo thaum lub chaw cov ntaub ntawv xav tau cov pob tw ntom ntom hauv txoj hauv kev thaum khaws cov kev paub duplex ntawm cov keyboards thiab cov servers.

Tus nqi yog kev ua haujlwm ntau dua li cov tshuaj pleev ib ce. Lub cev tuaj yeem ntsia tau thiab sim ua cov cuab yeej pob txha caj qaum thaum cov cassettes, cov hlua khi thiab cov hlua hloov pauv nrog cov khoom tsim. Qhov ntawd decouples cable txoj kev ua haujlwm los ntawm txhua lub cuab yeej refresh. Lub khib tuaj yeem txav los ntawm duplex 10G optics mus rau qhov sib npaug ntawm cov khoom siv los ntawm kev hloov cov npoo, muab cov pob txha pob txha muaj qhov tseeb fiber ntau, suav fiber ntau, polarity thiab optical margin.

Daim duab qhia kuj qhia txog lwm qhov tseem ceeb: cov pob txha fiber ntau suav nrog feem ntau yog ntau yam ntawm pawg fiber ntau. Qhov ntawd ua rau nws muaj peev xwm sib sau ua ke ntau cov kab hauv duplex rau hauv tus lej tswj tau ntawm lub cev sib dhos. Tab sis lub hauv paus-8, hauv paus-12 thiab ntau dua- suav tshuab yuav tsum tsis txhob sib xyaw ua ke. Lub 12-txoj haujlwm txuas tuaj yeem muaj nyob hauv lub cev uas tsuas yog yim fibers ua haujlwm; plaub txoj haujlwm tsis siv tsis yog qhov yuam kev yog tias tus qauv kho qhov muag hu rau plaub txoj kev xa mus thiab plaub txoj kab tau txais. Daim duab kos yuav tsum hais tias cov haujlwm twg yog cov neeg nyob thiab cov haujlwm twg yog txhob txwm ua tsaus.

info-800-450

4. Fiber suav: xaiv cov kab ntawv qhia, tsis yog tus lej loj tshaj plaws

MPO yog ib tsev neeg txuas, tsis yog ib qho fiber ntau suav. Ib-kab thiab ob-kab interfaces yog tus qauv hauv IEC 61754-7 series, thiab kev ua lag luam muaj cov rooj sib tham uas muaj nyob rau ntau daim ntawv thov. Hauv cov ntaub ntawv-chaw ua haujlwm, 8-, 12-, 16- thiab 24-fiber configurations feem ntau ntsib, tab sis cov txiaj ntsig fiber ntau yog txhais los ntawm cov khoom siv kho qhov muag thiab los ntawm cov qauv tsim nyob ib puag ncig lawv.

Rau 40GBASE-SR4 thiab 100GBASE-SR4 style parallel multimode txuas, plaub txoj kab xa tawm thiab plaub txoj kab tau txais yog nqa mus rau qhov sib npaug. Ib qho 8-fiber sib dhos siv tsuas yog txoj kab uas yuav tsum tau ua. Kev siv 12-txoj haujlwm yuav nqa tib yim txoj kab khiav haujlwm thaum tawm hauv qhov chaw tsis siv. Lwm daim ntawv thov siv tau cov fiber ntau suav los yog ob kab sib txuas. Qhov no yog vim li cas qhov kev txiav txim yuav hais tias tsuas yog '12F MPO cable rau 100G' tsis tiav: qhov kho qhov muag module, txoj kab khiav thiab txoj kev polarity tseem yuav tsum tau txhais.

Tib lub logic siv rau ib hom kev sib txuas ua ke optics thiab kev kub ceev breakout. Ib lub cable yuav muaj fiber ntau txaus tab sis tseem siv tsis tau vim tias cov fibers tshwm ntawm qhov tsis ncaj ncees lawm txoj haujlwm. Ua ntej BOM tau khov, kos daim ntawv qhia txoj kab ntawm Tx mus rau Rx thiab kos txhua qhov siv fiber ntau. Qhov kev kos duab yooj yim ntawd ntes tau qhov yuam kev ua ntej tshaj li kev sib tham txog lub tsho xim lossis cov khoom sib txuas khau raj style.

5. Polarity yog cov cuab yeej channel, tsis yog daim ntawv lo

Polarity yog qhov uas muaj ntau yam tsis raug MPO xa mus ua nyuaj rau kev daws teeb meem. Qhov laj thawj yog qhov yooj yim: MPO connector tso ntau qhov sib txawv ntawm fiber ntau tom qab ib lub tsev. Lub teeb tawm ntawm lub transmitter yuav tsum tuaj txog ntawm tus neeg txais kev sib raug zoo, tab sis qhov crossover tuaj yeem tsim tau hauv lub cev, hauv ib lub cassette, hauv ib txoj hlua, hauv ib qho adapter orientation, los yog ua ke ntawm cov khoom.

TIA cabling xyaum piav txog hom A, Hom B thiab hom C array-cable mappings. Ntawm qhov yooj yim tshaj plaws, Hom A yog ncaj qha mus, Hom B thim rov qab qhov kev txiav txim tiav fiber ntau, thiab Hom C sib pauv cov khub uas nyob ib sab. Daim duab 4 pom cov duab qhia chaw. Daim duab no txhob txwm ua kom yooj yim vim hais tias tag nrho cov channel tseem suav nrog cov txuas txuas, pinned thiab unpinned interfaces, modules thiab thaj qaum.

Cov lus qhia siv tau tsis yog 'ib txwm siv hom B' lossis 'ib txwm siv hom A.' Nws yog xaiv ib txoj kev sau cia polarity rau tag nrho cov channel thiab tom qab ntawd ua kom txhua qhov sib npaug nrog nws. Ob lub ntsiab lus uas txhua tus saib zoo ntawm daim ntawv teev cov ntaub ntawv tuaj yeem tshem tawm lossis theej ib qho kev sib tw uas yuav tsum tau ua. Thaum lub chaw khaws ntaub ntawv sib xyaw cov neeg muag khoom, cov ntaub ntawv kev yuav khoom zoo tshaj plaws yog daim ntawv qhia txoj kab lossis qhov kawg-rau-kawg polarity kos duab es tsis yog ib lo lus polarity daim ntawv lo.

6. MPO-to-LC breakout: qhov chaw uas cov kab ntawv tseem ceeb tshaj plaws

Ib tug breakout cable zoo li yooj yim: ib MPO connector ntawm ib sab thiab ob peb LC ob txhais ceg ntawm lwm yam. Hluav taws xob thiab optically, txawm li cas los xij, nws yog ib qho khoom siv kos duab. Txhua duplex LC khub yuav tsum sib haum mus rau qhov raug xa mus thiab tau txais txoj kab khub nyob rau hauv qhov chaw nres nkoj thaum uas tig mus, thiab lub active module yuav tsum qhia meej meej rau qhov thov breakout hom.

Ib qho kev siv cov ntaub ntawv yog ib qho txuas QSFP-chav kawm chaw nres nkoj muab faib ua plaub qhov qis dua duplex raws. Lub cable tsis tsim qhov breakout muaj nuj nqi; hloov chaw nres nkoj thiab transceiver ua. Lub cable tsuas nthuav qhia txoj kab. Yog hais tias cov cuab yeej tsis txhawb kev tawg, tsis muaj cov hlua khi tsis tuaj yeem ua rau nws ua tau. Tias yog vim li cas daim ntawv qhia kev hloov pauv thiab cov ntaub ntawv transceiver yog nyob rau hauv kev tshuaj xyuas cabling.

Labeling yog ib feem ntawm kev tsim kho qhov muag. Txhua LC ceg yuav tsum raug txheeb xyuas nyob rau hauv tib qho kev txiav txim siv los ntawm kev hloov pauv, thiab daim duab kos yuav tsum hais tias ceg twg yog channel 1, channel 2 thiab lwm yam. Hauv kev xa tawm loj, qhov no tiv thaiv qhov teeb meem kev sib koom ua ke: tag nrho cov fibers kuaj tau zoo, tab sis cov chaw nres nkoj logical tshwm nyob rau hauv qhov kev txiav txim tsis ncaj ncees lawm vim hais tias lub breakout ob txhais ceg tau patched los ntawm qhov ntev los yog lub cev txoj hauj lwm es tsis txhob ntawm txoj kab ID.

info-800-450

7. Optical poob: pob nyiaj siv lub mated interfaces, tsis yog lub cable

MPO yog qhov txaus nyiam vim tias nws txo cov kev sib txuas suav ntawm lub ntsej muag khib, tab sis cov channel modular tseem tuaj yeem muaj ntau qhov kev sib txuas kho qhov muag. Ib txoj hauv kev tuaj yeem suav nrog cov khoom siv hlua, MPO adapter, lub pob txha caj qaum, lub cassette thiab cov khoom siv ob sab. Txhua tus khub sib txuas sib txuas siv ib feem ntawm qhov poob nyiaj. Cov qauv tsim passive yuav tsum yog li ntawd muab piv nrog optical PMD pob nyiaj siv ua ntej qhov kev txiav txim muab tso, tsis yog tom qab qhov txuas tsis ua haujlwm.

Tsis txhob siv ib qho 'ib qho kev poob qis' los ntawm daim ntawv lag luam raws li kev siv nyiaj txiag engineering. Siv tus neeg muag khoom tau lees paub qhov siab tshaj plaws rau qib txuas txuas thiab ntxiv txhua qhov sib txuas sib txuas hauv cov phiaj xwm channel. Rau cov channel multimode, suav nrog fiber ntau attenuation ntawm kev khiav hauj lwm wavelength thiab ib qho ntxiv interfaces tsim los ntawm cassettes lossis cross-connects. Yog tias yuav tsum tau qhab nia qis MPO kom khaws cov paj, hais tias ntawm BOM thiab cov ntawv xeem yuav tsum tau ua.

Daim ntawv poob haujlwm tseem ceeb tshaj plaws yog luv luv: suav nrog interface, tsim nyiaj pub rau ib qho interface, fiber ntau ntev, fiber ntau attenuation thiab tag nrho cov kev xav tau channel poob. Nws lub hom phiaj tsis yog los kwv yees qhov tshwm sim ntawm qhov chaw mus rau qhov chaw thib ob. Nws lub hom phiaj yog ua kom pom cov interfaces zais thiab qhia seb tus qauv tsim puas muaj lub taub hau txaus rau kev ntsuas qhov tsis meej, yav tom ntej patching lossis ib qho kev sib txuas ntxiv.

Element Piv txwv kev npaj kom muaj nuj nqis Yuav siv dab tsi hauv qhov project tiag
MPO ua khub 2 Tau lees paub qhov siab tshaj plaws rau qib MPO xaiv
LC sib phim 2 Guaranteed siab tshaj plaws rau cov xaiv LC sib dhos
Cov pob txha fiber 50 m Tshwj xeeb attenuation ntawm kev khiav hauj lwm wavelength
Cassette / Internal sib dhos Yog siv Tus neeg muag khoom siab tshaj plaws lossis kuaj tus nqi module
Engineering margin Qhov project tshwj xeeb Kev pom zoo los ntawm tus tsim qauv / tus neeg teb xov tooj

Kev kuaj xyuas thiab kev lees paub

High-density connectors ua rau kom tus nqi ntawm kev hla qhov yooj yim fiber ntau huv si. IEC 61300-3-35: 2022 npog qhov muag pom ntawm fiber ntau-optic connector kawg ntsej muag thiab tshwj xeeb hais txog thaj tsam loj ntawm cov duab plaub. Rau MPO cov rooj sib txoos, kev tshuaj xyuas tsis yog hais txog ib qho tseem ceeb ntawm fiber ntau; Kev sib kis tuaj yeem zaum lwm qhov ntawm lub ferrule thiab tsiv teb tsaws thaum mating.

Ib qho kev lees paub ua ntu zus muaj nyob hauv daim duab 6. Tshawb xyuas ua ntej, ntxuav thaum xav tau, thiab tshuaj xyuas dua. Tom qab ntawd txheeb xyuas txoj kab txuas ntxiv thiab polarity. Kev ntsuas Tier 1 yuav tsum sau qhov kawg-rau-kawg attenuation thiab ntev rau cov fibers siv. Tier 2 OTDR xeem tuaj yeem muab ntxiv thaum qhov project xav tau cov ntaub ntawv txheej xwm txheej xwm lossis thaum poob yuav tsum tau nyob hauv zos. Ob theem teb cov lus nug sib txawv, yog li OTDR kab yuav tsum tsis txhob siv los hloov qhov kawg-rau-kawg attenuation tshwm sim.

Rau ib qhov haujlwm uas raug txiav tawm ntawm lub Hoobkas, thov cov txiaj ntsig kev xeem uas tuaj yeem khi rov qab rau lub rooj sib txoos xa los ntawm daim ntawv lo lossis tus lej xov tooj. Daim ntawv tshaj tawm yog qhov muaj txiaj ntsig zoo thaum nws hais txog qhov ntsuas wavelength, xeem txoj hauv kev, cov cim fiber ntau thiab kev lees paub txwv tsis yog tsuas yog qhia lub thawv PASS ntsuab xwb.

8. Kev tsiv teb tsaws chaw: rov siv lub pob txha rov qab tsuas yog thaum lub interface lej tseem ua haujlwm

Ib qho laj thawj uas cov neeg tsim qauv xaiv MPO pob tw yog qhov muaj peev xwm rov siv cov pob txha rov qab los ntawm ntau tshaj ib tiam khoom siv. Qhov ntawd tuaj yeem ua haujlwm tau zoo, tab sis qhov kev thov rov siv dua yuav tsum tau sim tawm tsam qhov cuam tshuam tiag tiag es tsis yog kho raws li cov lus cog tseg yav tom ntej.

Xav txog ib chav tsev ntaub ntawv uas pib siv cov khoom siv duplex LC tab sis sib sau cov kab duplex los ntawm MPO-rau-LC cassettes. Thaum lub sijhawm hloov tshiab tom qab, tus neeg teb xov tooj tuaj yeem tshem tawm cov kab ntawv, teeb tsa MPO adapter panels thiab txuas cov khoom sib txuas ncaj qha los ntawm lub cev uas twb muaj lawm. Txoj hauv kev thiab cov pob txha ruaj khov nyob hauv qhov chaw thaum lub rack-ntug kev sib txuas hloov pauv. Qhov no yog lub tswv yim kev tsiv teb tsaws chaw pom nyob rau hauv daim duab 7 thiab nws yog ib qho ntawm cov kev sib cav muaj zog tshaj plaws rau kev hloov pauv siab ceev.

Cov xwm txheej nruj. Lub pob txha caj qaum yuav tsum muaj qhov tseeb fiber ntau rau cov optics tshiab, cov fibers txaus siv tau rau hauv cov haujlwm uas yuav tsum tau muaj, qhov sib txuas sib txuas geometry thiab polish, thiab cov npoo npoo npoo txaus. Polarity kuj yuav tsum tau rov siv dua vim tias tshem tawm cov kab ntawv tuaj yeem tshem tawm qhov kev sib tw uas yav dhau los yog ib feem ntawm cov channel. Yog li ntawd, ib qho kev tsiv teb tsaws chaw yuav tsum khaws daim ntawv qhia txoj kab qub thiab cov ntaub ntawv xeem nrog cov ntaub ntawv khib nyiab.

9. Cov ntsiab lus ntawm kev teeb tsa uas tiv thaiv tus qauv zoo

Txawm hais tias MPO channel yuav raug puas los ntawm kev tsis zoo. High-density trunks yog compact, uas tuaj yeem ntxias cov installers kom overfill managers los yog rub cov rooj sib txoos los ntawm txoj kev uas tsis muaj kev tiv thaiv txaus. Saib xyuas cov chaw tsim khoom cable qhov tsawg kawg nkaus lub vojvoog nkhaus thiab tensile txwv, siv rub ob lub qhov muag thaum lub rooj sib txoos muab nrog rau lawv, thiab tiv thaiv qhov xaus ua ntej ntawm plua plav thiab sab loading thaum lub sij hawm installation.

Npaj slack txhob txwm tshaj tawm. Tshaj lub cev ntev khoom qab lub chassis tsim khoov thiab nkag mus rau cov teeb meem; ib lub cev uas luv dhau zog nro rau hauv lub cev connector. Cov kev teeb tsa huv huv tshaj plaws siv cov kev ntsuas qhov ntev, qhov kev pabcuam lub voj voog qhov chaw thiab kev tswj xyuas cais rau cov pob tw thiab cov khoom siv patch cords. Qhov no kuj ua rau kev sib cais tom qab tau yooj yim dua vim tias cov kws tshaj lij tuaj yeem pom cov kab ntawv twg yog qhov txuas mus tas li thiab qhov twg cable yog npaj txav mus.

Hauv modular chassis, tawm hauv chav ua haujlwm txaus los tshuaj xyuas thiab ntxuav MPO cov chaw nres nkoj. Ib qho qauv tsim uas ncav cuag qhov zoo nkauj fiber ntau ntawm daim ntawv tab sis tsis tawm ntawm kev sojntsuam nkag tsis tau. Qhov ceev yog qhov muaj txiaj ntsig tsuas yog tus kws tshaj lij tuaj yeem txheeb xyuas, txiav tawm, ntxuav thiab rov txuas qhov tseeb interface yam tsis muaj kev cuam tshuam nws cov neeg nyob ze.

10. Tsib qhov xwm txheej tsis ua haujlwm thiab yuav tiv thaiv lawv li cas

Lub cable haum, tab sis qhov txuas nyob twj ywm tsaus. Lub connector geometry yog mechanically sib xws, tab sis Tx fibers tsis tsaws ntawm qhov xav tau Rx txoj haujlwm. Kev Tiv Thaiv: Tshawb xyuas daim ntawv qhia txoj kab ua tiav, suav nrog cov ntawv kaw lus thiab cov khoom hloov pauv, tsis yog hloov lub pob tw ntawm random.

Kev tawg ua haujlwm ntawm ob txhais ceg tab sis tsis yog tag nrho plaub. Qhov chaw nres nkoj nquag tsis tau teeb tsa rau hom kev xav tau tawg, lossis cov ceg txiav txim tsis sib haum rau cov khoom siv kab zauv. Kev Tiv Thaiv: Txheeb xyuas qhov hloov pauv thiab kev txhawb nqa transceiver breakout ua ntej rov kho dua LC ob txhais ceg.

Kev poob yog siab dua tom qab lub khib txav. Kev kis kab mob los yog kev ntxhov siab khoov tau qhia thaum rov txuas dua. MPO ferrules muaj qhov sib cuag loj thiab ntau cov fibers tuaj yeem cuam tshuam ib zaug. Kev Tiv Thaiv: Tshawb xyuas-hloov-tshuaj xyuas, tom qab ntawd rov ua qhov kev sim poob Tier 1 thiab siv OTDR yog tias qhov poob yuav tsum nyob hauv cheeb tsam.

Ib tiam tshiab module tsis tuaj yeem rov qab siv lub cev qub. Cov pob txha laus muaj qhov tsis ncaj ncees lawm hom fiber ntau, cov neeg ua haujlwm, polish lossis txuas txuas rau cov optics tshiab. Kev Tiv Thaiv: Kho kev tsiv teb tsaws chaw raws li kev kuaj xyuas engineering, tsis yog kev cog lus nrog rau lo lus MPO.

Lub Hoobkas tshaj tawm dhau, tab sis daim ntawv tshaj tawm ntawm qhov chaw tsis sib xws. Cov txheej txheem siv, tso tawm tej yam kev mob, wavelengths los yog channel txhais txawv ntawm lub Hoobkas thiab cov kev ntsuam xyuas teb. Kev Tiv Thaiv: Pom zoo rau txoj kev lees paub thiab siv dav hlau ua ntej tsim khoom, thiab khaws cov txheej txheem xeem nrog PO.

11. Ib hom thiab multimode MPO daws teeb meem sib txawv

MPO vaj tse tsis ua ib qho channel ib hom lossis multimode. Cov fiber ntau, polish, active optics thiab ncav cuag qhov yuav tsum tau ua. Qhov kev sib txawv ntawd tseem ceeb vim tias tib tsev neeg sib txuas tuaj yeem zaum hauv ob qhov sib txawv tsim qauv. Nyob rau hauv ib tug luv luv-mus txog multimode ntaub, qhov tseem ceeb yog feem ntau qhov chaw nres nkoj ceev, txoj kab kev qhia, khoov tswj thiab tsiv teb tsaws ntawm duplex thiab parallel optics. Nyob rau hauv ib hom ntaub, kev xav txog kev tswj, transceiver interface cov ntsiab lus thiab qhov tseeb parallel-optics scheme yuav nqa hnyav dua.

Multimode MPO muaj nyob ib ncig ntawm SR-chav kawm thaum uas tig mus optics vim ntau fibers muaj peev xwm nqa txoj kab nyob rau hauv parallel yam tsis muaj wavelength multiplexing. Cov lus nug tsim yog feem ntau muaj pes tsawg fibers ua haujlwm, seb lub channel siv lub hauv paus-8 los yog lub pob txha loj dua, thiab qhov txuas yuav ua li cas thaum lub sij hawm tsiv teb tsaws chaw. Ib hom MPO yog siv nyob rau hauv daim ntaub ntawv xws li parallel single-mode optics thiab lwm yam high-density khoom interfaces, qhov twg cov connector polish thiab rov-poob yuav tsum tau xyuas kom meej tiv thaiv cov ntaub ntawv module es tsis tau theej los ntawm ib tug multimode BOM.

Tsis txhob siv lub tsho xim raws li qhov kev lees txais zaum kawg. Xim yog ib qho txiaj ntsig pom pom, tab sis nws tsis yog qhov hloov pauv rau cov cim kab, cov lus qhia fiber ntau lossis lub Hoobkas tshaj tawm. Cov txheej txheem tau txais kev nyab xeeb tshaj plaws yog sib npaug ntawm tus lej luam tawm thiab hom fiber ntau rau BOM pom zoo, tom qab ntawd txheeb xyuas cov khoom sib txuas thiab cov ntaub ntawv pov thawj ua ntej lub cable raug tso tawm rau kev teeb tsa.

Cov lus nug tsim Multimode tseem ceeb Ib hom tseem ceeb
Active interface Parallel SR txoj kab suav thiab pej xeem txoj haujlwm Ib hom kev sib luag / serial interface
Fiber specification OM3 / OM4 / OM5 raws li xav tau los ntawm optics OS2 los yog teev ib hom fiber ntau
Connector nthuav dav Polarity, keying, nquag fiber ntau txoj haujlwm Polarity ntxiv rau polish thiab xav tau kev xav
Migration check Base fiber pab pawg thiab breakout txoj kev Connector geometry, daim ntawv qhia txoj kab thiab PMD compatibility
Txais Kev tshuaj xyuas, polarity, Tier 1 poob; Tier 2 yog tias xav tau Cov ntaub ntawv pov thawj zoo ib yam, nrog rov qab-poob / xav tau kev xav tau qhov twg tau teev tseg

Xaus: qhia txoj hauv kev, tsis tsuas yog thaj qaum

Ib qho MPO fiber thaj qaum daws tau txais nws cov nqi thaum nws ua rau lub cev txheej denser tsis ua rau nws nyuaj rau kev nkag siab. Lub connector tsuas yog ib qho xwb. Cov txheej txheem ua haujlwm yog kev sib xyaw ua ke ntawm kev sib txuas ua haujlwm, thaj cords, pob tw, panels, cassettes lossis breakouts, polarity plan, optical pob nyiaj siv thiab cov pov thawj lees paub.

Ob daim duab kos duab qhia txog txoj hauv kev zoo los xav txog MPO: raws li kev tsim qauv. Ib qho qhia tau hais tias lub ecosystem modular nyob ib ncig ntawm racks thiab chassis; Lwm qhov qhia tau hais tias yuav ua li cas cov khoom siv duplex tuaj yeem sib sau ua ke los ntawm cov pob txha muaj fiber ntau. Los ntawm qhov ntawd, cov txheej txheem tsim tau zoo ib yam - txheeb xyuas cov chaw nres nkoj nquag, daim ntawv qhia txoj kab, xaiv cov khoom siv tsis zoo, pob nyiaj siv rau kev sib tshuam, thiab txheeb xyuas seb cov channel tiav yuav raug kuaj li cas.

Rau B2B kev yuav khoom, txoj hauv kev no kuj ua rau RFQ zoo dua. Es tsis txhob nug ib tus neeg muag khoom rau 'MPO cable rau 100G,' qhov project tuaj yeem muab qhov tseeb interface, fiber ntau daim ntawv qhia, polarity, ntev, poob lub hom phiaj, daim ntawv lo thiab pov thawj xav tau. Qhov ntawd yog qhov hloov pauv ntau-fiber cable rau hauv cov ntaub ntawv rov qab-chaw cabling daws teeb meem.

Xa kev nug