MPO Fiber Patch Vaj Huam Sib Luag: Siab -Density Structured Cabling rau 40G, 100G thiab 400G Data Centers

Mar 24, 2026

Tso lus

MPO fiber ntau thaj vaj huam sib luag yog dab tsi? Txhais, qauv, thiab siv cov ntaub ntawv

mpo patch

IbMPO fiber ntau thaj vaj huam sib luag(tseem hu ua MTP fiber ntau thaj vaj huam sib luag thaum US Conec MTP® connectors raug siv) yog 19-inch khib-mount unit uas ua raws li kev sib txuas siab ntawm qaum qaum MPO lub cev cables thiab LC lossis SC thaj qaum uas ntsaws ncaj qha rau hauv cov keyboards, servers, thiab transceivers.

Lub vaj huam sib luag muaj ib kab ntawm MPO adapter lub tes tsho nyob rau pem hauv ntej lub ntsej muag - txais kiv cua- tawm MPO thaj qaum - thiab ib txheej ua ntej - txiav MPO cassettes lossis pigtail modules sab hauv. Cov cassettes tawg tawm txhua 12-fiber lossis 24-fiber MPO rau hauv ib tus neeg LC duplex lossis SC simplex connectors nthuav tawm rau pem hauv ntej. Qhov tshwm sim yog tag nrho passive, pre-tested optical crossconnect uas yuav tsum tsis muaj teb splicing.

Yuav ua li cas MPO thaj vaj huam sib luag txawv ntawm cov qauv LC lossis SC panels

Lub ntsiab lus sib txawv yog fiber ntau ntom. Tus qauv 1U LC duplex vaj huam sib luag tuav 24 duplex ports - 48 ib tus neeg fiber ntau txuas. 1U MPO thaj vaj huam sib luag siv 24- fiber ntau cassettes thiab quad-LC adapters tuavmus txog 144 tus neeg fibershauv tib chav tsev khib - a3 × mus rau 6 × kev txhim kho ceev, nyob ntawm configuration. Qhov no tseem ceeb ncaj qha rau hauv hyperscale thiab AI cov ntaub ntawv chaw nyob qhov twg txee qhov chaw yog nyiaj tau los ntawm ib chav tsev khib.

Hom vaj huam sib luag 1U fiber ntau Hom Connector Hom kev siv
Standard LC Duplex 1U 24 fibers LC duplex Legacy 10G SFP + ib puag ncig
MPO-12 vaj huam sib luag, 1U (6 cassettes) 72 cev MPO-12 rear / LC pem hauv ntej 40G / 100G SR4 qauv cabling
MPO-24 vaj huam sib luag, 1U (6 cassettes) 144 fiber ntau MPO-24 rear / LC pem hauv ntej 100G / 400G siab- ceev
2U MPO vaj huam sib luag (12 cassettes) 144-288 fiber ntau MPO-12 los yog MPO-24 Core- txheej txha nraub qaum hloov

Ntsiab-nce vs qhov tseem ceeb- nqis taw qhia - cuam tshuam rau polarity

Txhua MPO connector muaj lub cev qhov tseem ceeb (ib tug tsa notch) ntawm ib sab ntawm lub ferrule. Seb tus yuam sij ntawd tig mus rau sab saud (key -up) los yog downward (key- nqes) thaum mated txiav txim siab qhov twg ntawm 12 lossis 24 fibers aligns rau txoj kab transceiver. Qhov tsis sib haum xeeb ntawm lub vaj huam sib luag lub adapter orientation thiab lub cev cable lossis transceiver kev cia siab yogib qho feem ntau ua rau MPO txuas tsis ua haujlwmntawm commissioning. Glory Optics panels nkoj nrog adapter orientation sau npe rau ib qhov chaw nres nkoj, thiab suav nrog cov ntawv teeb tsa polarity rau txhua qhov kev txiav txim.

Shutter vs non{0}}shutter adapters

Nyob rau hauv ib puag ncig hyperscale qhov chaw nres nkoj feem ntau unmated thiab remated, caij nplooj ntoos hlav -loaded shutter adapters tiv thaiv lub ferrule kawg-lub ntsej muag los ntawm huab cua los ntawm kev sib txuas. Rau kev xa cov pob txha zoo li qub uas cov chaw nres nkoj txuas nrog rau lub hlis, tsis yog - shutter adapters yog tsim nyog thiab tus nqi qis dua. Glory Optics muaj ob qho kev sib txawv ntawm txhua lub vaj huam sib luag daim ntawv.

 

Cov ntawv thov tseem ceeb

MPO fiber ntau thaj vaj huam sib luag yog txheej txheem txheej txheem txheej txheem hauv peb qhov xwm txheej uas txhais cov ntaub ntawv chaw tsim kho niaj hnub:

Tus txha nqaj- nplooj ntaub interconnects:Txhua nplooj -rau- qaum uplink khiav ua ntej - txiav MPO lub cev. Cov vaj huam sib luag ntawm ob qho kawg ntawm lub cev muab cov txheej txheem sib txuas thiab tso cai rau ib qho - txuas patching yam tsis muaj kev cuam tshuam kev sib txuas.

Sab saum toj - ntawm - khib (ToR) server cabling:Server NICs nrog QSFP28 (100G) lossis QSFP-DD (400G / 800G) cov chaw nres nkoj txuas ntawm luv MPO sib dhos rau ToR hloov los ntawm lub vaj huam sib luag ntawm lub khib nyiab. Ua ntej-tawm vaj huam sib luag tso cai rau tag nrho 48- chaw nres nkoj khib kom muaj fiber ntau txuas hauv qis dua ob teev.

AI GPU pawg kab txuas:NVidia GB300 thiab Blackwell{1}} tiam neeg pawg qhia meej meej txog kev tsim MPO cabling rau InfiniBand thiab Ethernet fabrics. Qhov kev kwv yees qhov kev poob qis ntawm lub vaj huam sib luag-raws li kev teeb tsa cabling yog qhov tseem ceeb rau kev tswj cov kab sib txuas hla cov rog- tsob ntoo GPU- mus rau -GPU txoj hauv kev hla ntau pua ntawm cov nodes.

product-857-594

 

MPO fiber ntau thaj vaj huam sib luag hom - yuav ua li cas xaiv txoj kev teeb tsa

MPO thaj vaj huam sib luag kev lag luam tau faib ua ntau yam tshwj xeeb los pab 40G, 100G, 400G, thiab tawm 800G architectures. Xaiv qhov tsis ncaj ncees lawm qhov sib txawv ntawm kev yuav khoom xauv koj mus rau hauv qhov poob - teeb meem nyiaj txiag lossis kev cuam tshuam tsis sib xws uas tsis muaj software workaround tuaj yeem kho.

 

Los ntawm chaw nres nkoj suav thiab khib-unit form factor

Form factor MPO ports (rov qab) Max pem hauv ntej fibers Daim ntawv thov phiaj
1U · 6-port MPO-12 6 × MPO-12 72 40G / 100G nkag txheej
1U · 6-port MPO-24 6 × MPO-24 144 100G/400G siab- ceev
2U · 12-chaw nres nkoj MPO-12 12 × MPO-12 144 Kev sib koom ua ke ntawm cov pob txha pob txha
2U · 12-chaw nres nkoj MPO-24 12 × MPO-24 288 Hyperscale core txheej
4U swb tub rau khoom Txog li 48 × MPO-12 576 ODF hloov hauv DCs loj

Daim ntawv qhia txog kev siv khib nyiab:Lub 42U cov ntaub ntawv chaw txee xa tawm 1U MPO-24 panels tuaj yeem txiav tawmmus txog 6,048 tus neeg fibersnyob rau hauv lub vaj huam sib luag kab - txaus rau 400G txha nraub qaum hloov nrog 32 QSFP-DD chaw nres nkoj, txhua qhov yuav tsum tau muaj 16 fibers, hla 192 qhov chaw nres nkoj ntawm cov qauv cabling. Qhov no yuav xav tau 4 lub txee tag nrho ntawm LC cov vaj huam sib luag kom sib npaug tib yam.

Lub 2U fiber ntau thaj vaj huam sib luag: thaum twg yuav txav mus

Daim ntawv 2U yog qhov ncaj ncees thaum ib qho patch point aggregates ntau tshaj rau 24-fiber trunk cables - ib txwm muaj nyob rau ntawm tus txha nraub qaum thiab hauv loj - nplai neeg rau zaub mov kab aggregation. Qhov ntxiv 1U ua kom haum zoo dua cable khoov vojvoog tswj ntawm lub nraub qaum thiab tso cai rau lub tub rau khoom zawv zawg uas muab rau pem hauv ntej nkag mus rau cov ntawv kaw lus tsis muaj kev cuam tshuam cov kab nyob.

 

Los ntawm hom connector: MPO-12, MPO-16, thiab MTP Elite

MPO-16 - yuav tsum tau ua rau 400G SR8 thiab DR8

Qhov no yog qhov yuam kev tshwj xeeb tshaj plaws hauv 400G xa tawm. Cov400G-SR8 thiab 400G-DR8 transceiver qauv xav tau MPO-16 interface(16- fiber ntau ferrule). Kev xa tawm MPO-12 vaj huam sib luag ntawm 400G-SR8 hloov chaw nres nkoj tsim lub cev tsis sib haum - lub cev txuas yog tib yam sab nraud tab sis tus lej ferrule suav txawv. Tsis muaj qhov hloov pauv uas txuas MPO-12 rau MPO-16. Yog tias koj lub network txoj hauv kev muaj xws li 400G SR8, tag nrho cov txheej txheem nruab hnub no yuav tsum siv MPO-16. Glory Optics MPO-16 panels muaj nyob rau hauv 1U thiab 2U configurations nrog OS2 thiab OM4 cassettes.

⚠ 400G xa tawm ceeb toom:Ua ntej xaj MPO panels, paub meej tias koj lub transceiver SKU tiv thaiv IEEE 802.3cd (400G-SR8) lossis 802.3ck (400G-CR8) tus qauv. SR8 xav tau MPO-16; SR4.2 thiab FR4 siv MPO-12 (nrog duplex LC breakout). Kev sib xyaw cov no hauv tib qhov kev sib txuas txuas txuas ua ke tsim ib qho kev tsim kho vaj tse uas tsis tuaj yeem rov qab siv dua rau lwm tus qauv.

MTP Elite vs standard MTP: qhov poob peev nyiaj sib txawv

Txheem MTP connectors raws li IEC 61754-7 ntawmTsawg dua los yog sib npaug rau 0.5 dB qhov poob. MTP Cov neeg tseem ceeb qib, nrog precision- hauv av ferrule geometry thiab nruj tus pin- qhov tolerances, ua tiavTsawg dua lossis sib npaug li 0.25 dB- kev txhim kho 50%. Ntawm 400G SR8 txuas nrog 4.7 dB poob peev nyiaj (IEEE 802.3cd), qhov sib txawv ntawm cov qauv thiab cov neeg tseem ceeb txuas thoob plaws plaub- kev sib koom ua ke- txoj kev teeb tsa tuaj yeem txhais tau tias qhov sib txawv ntawm kev dhau mus thiab ua tsis tiav cov peev nyiaj. Glory Optics muaj MTP Elite cassettes raws li tus qauv kev xaiv ntawm tag nrho 1U thiab 2U vaj huam sib luag teeb tsa; Hoobkas insertion poob kev xeem ntawv qhia nrog rau txhua qhov kev txiav txim.

 

Los ntawm fiber ntau: OS2, OM3, OM4, OM5

Fiber hom Xim Max ncav cuag 100G-SR4 Max ncav cuag 400G-SR8 Zoo tshaj rau
OM3 multimode Aqua 70 m 50 m Luv intra-rack khiav; qub txeeg qub teg
OM4 multimode Violet 100 m 70 m Standard data center structured cabling
OM5 wideband MM Txiv qaub ntsuab 150 m 150 m (SWDM8) Ntev - ncav cuag multimode; wavelength multiplexing
OS2 single-mode Daj 10km (LR4) 500 m (DR8) Inter-lub tsev, tsev kawm ntawv, DCI

 

Los ntawm polarity: Hom A, B, thiab C

Polarity txhais li cas fiber ntau txoj hauj lwm yog mapped kawg - mus rau - xaus los ntawm lub cabling system kom kis tau tus mob ntawm ib tug ntaus ntawv mus rau tau txais ntawm lwm tus. TIA-568 txhais peb txoj kev. Lub thaj vaj huam sib luag sab hauv cassette thaiv kev txiav txim siab uas nws txhawb nqa.

  • Txoj Kev A (ncaj-los ntawm):Feem ntau siv rau 40G thiab 100G SR4. Fiber 1 ntawm ib kawg maps rau fiber 1 ntawm lwm yam. Siv Hom A lub cev + Hom A thaj qaum lossis Hom B thaj qaum nyob ntawm qhov hloov.
  • Txoj Kev B (hla- dhau ntawm lub vaj huam sib luag):Fiber txoj hauj lwm yog flipped nyob rau hauv lub cassette. Siv thaum ob lub pob tw cables thiab thaj cords yog Hom A. Feem ntau hauv Cisco thiab qee qhov kev xa tawm ntawm Arista.
  • Txoj Kev C (pair-flip):Cov khub fiber ntau uas nyob ib sab yog sib pauv hauv lub cassette. Siv thaum lub cev hom A yuav tsum tau muaj thoob plaws thiab qhov crossover tshwm sim ntawm qib cassette.
  •  

Txoj cai siv tau:txiav txim siab koj txoj kev polarity ua ntej xaj panels. Tag nrho peb hom cassette yog hloov pauv tau hauv Glory Optics vaj huam sib luag vaj tsev nyob - koj tuaj yeem sib tov txoj hauv kev los ntawm pawg chaw nres nkoj ntawm tib lub vaj huam sib luag - tab sis koj tsis tuaj yeem hloov cov kab cassette hauv thaj teb. Hu rau peb pab pawg engineering nrog koj cov qauv transceiver thiab pob tw cable spec; peb yuav paub meej tias hom cassette raug ua ntej ntau lawm.

 

Kev ua tau zoo specifications - tus lej txhais tau li cas rau koj lub network

Cov ntaub ntawv kev ua tau zoo los ntawm cov chaw muag khoom fiber ntau nyiam hais txog IEC tus qauv yam tsawg kawg nkaus, uas yog hauv pem teb, tsis yog qhov khoom muaj peev xwm tiag tiag. Qhov tshwj xeeb uas tseem ceeb rau koj cov peev nyiaj txuas yog qhovkev ntsuas lub Hoobkas, tsis yog kev ua raws cai. Glory Optics luam tawm batch- cov ntaub ntawv ntsuas qib vim tias peb cov txheej txheem tsim khoom yog tsim los ntawm nws.

 

Insertion poob: kev lag luam tus qauv vs Glory Optics Hoobkas cov ntaub ntawv

Connector qib IEC 61754-7 txwv Glory Optics batch Avg. Glory Optics phem tshaj - rooj plaub
Txheem MPO (PC) Tsawg dua los yog sib npaug li 0.5 dB 0.35 dB 0.48 dB
MTP® (US Conec, PC) Tsawg dua los yog sib npaug li 0.5 dB 0.31 dB 0.42 dB
MTP® Cov Neeg Tseem Ceeb (US Conec, PC) Tsawg dua lossis sib npaug li 0.35 dB 0.22 dB 0.34 dB
MTP® Cov Neeg Tseem Ceeb (US Conec, APC) Tsawg dua lossis sib npaug li 0.35 dB 0.24 dB 0.34 dB

ISO 9001: 2015- Txhua qhov kev ntsuas qhov poob tau ua tiav ntawm 100% ntawm cov cassettes siv 3D interferometry ua ntej xa khoom. Batch test reports suav nrog txhua qhov kev txiav txim. Cov ntawv qhia ua piv txwv muaj nyob ntawm kev thov.

Dab tsi 0.1 dB qhov poob qhov sib txawv txhais tau tias hla 10-hop txuas pob nyiaj siv

Xav txog 400G-SR8 txuas (IEEE 802.3cd, 70-meter OM4 txoj kev). IEEE poob nyiaj txiag rau qhov kho qhov muag channel yog4.7dB ib. Ib txoj hauv kev sib txuas ua ke feem ntau muaj 4 cov ntsiab lus mating: ob ntawm lub vaj huam sib luag, ib qho ntawm txhua qhov kawg ntawm lub tawb transceiver. Ntawm tus qauv MTP spec (0.5 dB txhua), uas yog 2.0 dB tsuas yog nyob rau hauv connector poob, tawm hauv 2.7 dB rau fiber ntau attenuation thiab margin. Ntawm Glory Optics MTP Elite (0.22 dB txhua), connector poob poob rau 0.88 dB - tawm ntawm 3.82 dB rau fiber ntau thiab paj. Qhov kev txhim kho 1.12 dB ntawd tso cai rau ib qho txuas txuas ntev dua, siv qis dua - nqi OM3 fiber ntau, lossis ntxiv cov txheej txheem yooj yim rau yav tom ntej re-patching.

 

Rov qab poob, repeatability, thiab mating cycles

Parameter Spec (APC) Spec (UPC / PC) Glory Optics kuaj tus nqi
Rov qab poob Ntau dua lossis sib npaug li 65 dB Ntau dua lossis sib npaug li 20 dB Ntau dua lossis sib npaug rau 67 dB (APC) / Ntau dua lossis sib npaug rau 55 dB (UPC)
Insertion poob hloov tom qab 500 matings Tsawg dua lossis sib npaug li 0.2 dB Tsawg dua lossis sib npaug li 0.2 dB Tsawg dua lossis sib npaug rau 0.08 dB (kuaj)
Rated mating cycles 500+ 500+ 500 cycles, IL hloov tsawg dua los yog sib npaug rau 0.08 dB
Ua haujlwm kub -20℃rau +70 degree -20℃rau +70 degree -20℃rau +70 degree
Cia kub -40℃rau +85 degree -40℃rau +85 degree -40℃rau +85 degree

Tus 500- sib xyaw- voj voog durability daim duab yog qhov tsawg kawg nkaus IEC. Hauv kev xyaum, thaj vaj huam sib luag hauv thaj chaw colocation uas rov- thaj 10 chaw nres nkoj ib hnub yuav siv sijhawm 50 hnub kom ncav cuag 500 matings ib qhov chaw nres nkoj - txhais tau tias lub neej 5-xyoo ntawm hnyav- siv cov chaw nres nkoj hauv txhua hnub. Glory Optics vaj huam sib luag vaj huam sib luag siv stainless-steel caij nplooj ntoos hlav clips thiab engineering-qib nylon lub cev ntsuas los tuav lub zog sib txuas hauv qhov tshwj xeeb thoob plaws qhov kev ua haujlwm kub.

 

Environmental thiab ua raws specifications

RoHS 3 (EU 2015/863) thiab REACH SVHC

Txhua Lub Hwj Chim Optics MPO fiber ntau thaj vaj huam sib luag ua raws RoHS 3 Cov Lus Qhia EU 2015/863, uas txwv 10 yam khoom phom sij hauv cov khoom siv hluav taws xob thiab hluav taws xob

 

CE Marking

CE kos rau ntawm Glory Optics panels npog Cov Lus Qhia Tsawg Voltage (LVD) thiab electromagnetic compatibility (EMC) yuav tsum muaj rau cov khoom siv kho qhov muag tsis pom kev hauv cov ntaub ntawv chaw ib puag ncig.

 

Cable tsho xaiv rau kev ua raws cai hauv cheeb tsam

Qhia lub tsho hom ntawm kev txiav txim; sib xyaw configurations nyob rau hauv ib qho kev txiav txim yog nyob ntawm tsis muaj nqi ntxiv rau kev txiav txim siab tshaj 20 units.

MPO thaj vaj huam sib luag vs ODF: qhov kev daws teeb meem twg zoo rau koj qhov kev xa tawm?

Cov ntsiab lusODF(Optical Distribution Frame) thiabfiber ntau thaj vaj huam sib luagQee zaum siv sib hloov hauv kev yuav khoom, uas ua rau muaj qhov yuam kev. Lawv daws teeb meem sib txawv infrastructure.

 

Cov qauv sib txawv: passive termination vs field splicing

 

Dimension ODF (Optical Distribution Frame) MPO Fiber Patch Vaj Huam Sib Luag
Txoj kev txiav tawm Teb-spliceed pigtails los yog teb-tawm connectors; yuav tsum tau fusion splicing khoom Factory ua ntej-tawm, ntsaws-thiab-play; tsis xav tau splicing
Chaw nres nkoj suav rau U Feem ntau 12–96 SC / LC ports ib U (vim los ntawm chassis) Txog li 144 LC - sib npaug fibers ib 1U
Lub sijhawm xa tawm 2-4 teev rau 96-chaw nres nkoj ODF nrog kev sib tshuam 20–40 feeb rau 144-fiber 1U vaj huam sib luag (plug-in cassettes)
Reconfigurability Tsawg - spliced ​​kev twb kev txuas yuav tsum re-spling txav High - cassettes yog cov cuab yeej- pub dawb sib pauv hauv / tawm; rau -chaw nres nkoj patching hauv vib nas this
Qhov chaw siv thawj zaug Sab nraum nroj tsuag, feeder cable termination, long-haul, campus backbone entry Data center intra-chaw tsim qauv cabling; qaum-nplooj, ToR, AI pawg
Ib qho kev ntxig ntxig poob rau ib qho kev sib txuas Splice poob ≈ 0.05–0.1 dB + connector 0.2–0.5 dB Connector-tsuas yog txoj kev ≈ 0.22–0.35 dB ib mating (tsis muaj splice)
Tus qauv nqi Kev ua haujlwm siab dua installation; qis dua ib -port hardware tus nqi ntawm qhov ntsuas Tus nqi kho vajtse siab dua; qis tag nrho cov nqi nruab nrab thaum ua haujlwm raug ntsuas

 

Kev txiav txim matrix - ODF vs MPO thaj vaj huam sib luag

info-689-338

Xaiv ODF thaum:

Tshem tawm sab nraud- cog feeder cables (aerial, ncaj qha- faus, armored)

Kev sib txuas mus tas li uas yuav tsis txav mus rau 5+ xyoo

Cov peev nyiaj raug txwv thiab hauv - tsev fusion splicing neeg coob muaj

Chaw nres nkoj suav tshaj 96 ib qhov chaw (ODF 96-chaw nres nkoj ntas nplai zoo dua)

Kev xa tawm hauv tsev cov ntsiab lus nkag lossis MDF / IDF chav

Xaiv MPO thaj vaj huam sib luag thaum:

Dynamic data center ib puag ncig - nquag txav, ntxiv, hloov

Kev ceev ntawm kev xa tawm yog qhov tseem ceeb (huab tawg, GPU pawg nthuav dav)

40G / 100G / 400G structured cabling nrog parallel optics transceivers

Qhov chaw khib yog hwm - xav tau 144+ fibers hauv 1U

Tsis muaj fusion splicing muaj peev xwm los yog xav kom zam nws

info-1228-310

Txoj kev tsiv teb tsaws: xa MPO panels nrog rau ODF thav ntawv uas twb muaj lawm

Hauv cov chaw sib xyaw ua ke - feem ntau hauv cov chaw lag luam cov ntaub ntawv uas tsim tawm nrog ODF hauv xyoo 2010s thiab tam sim no ntxiv 100G / 400G muaj peev xwm - MPO thaj vaj huam sib luag tau muab tso rau hauv cov khib nyiab tshiab thiab thaj chaw thaum muaj ODF thav duab tau khaws cia rau lawv lub tsev - nkag thiab sab nraud{6} Ob lub tshuab txuas los ntawm OS2 ib leeg- hom kab hlau txuas nrog LC txuas ntawm sab ODF thiab MPO-12 txuas ntawm cov ntaub ntawv chaw vaj huam sib luag sab, txuas los ntawm lub tshuab luam ntawv uas hloov LC- rau-MPO sab hauv. Txoj hauv kev sib xyaw no zam kev hloov pauv tag nrho thiab tso cai rau thaj tsam -los ntawm thaj chaw tsiv teb tsaws raws li kev hloov pauv hloov tshiab tshwm sim.

 

Tag nrho cov nqi ntawm cov tswv cuab: 5-xyoo kev sib piv

A 96-chaw nres nkoj ODF nrog kev txiav tawm ntawm thaj chaw ntawm $ 0.80 / chaw nres nkoj kho vajtse tus nqi yuav tsum muaj kwv yees li8-12 teev ntawm fusion splicing zogntawm 96-chaw nres nkoj ncej, ntxiv rau OTDR lub sijhawm xeem. Ntawm cov ntawv cog lus ib txwm muaj rau cov ntawv tso cai fiber ntau ($ 85-120 / teev hauv North America), tus nqi nruab nrab ntawm 96-chaw nres nkoj ODF khiav $ 800-1,400 hauv kev ua haujlwm ib leeg. Qhov sib piv 96-fiber MPO thaj vaj huam sib luag ntawm $ 180-220 kho vajtse tus nqi xa mus rau hauvhauv qab 45 feebuas tsis muaj cov cuab yeej tshwj xeeb - tag nrho cov nqi nruab nrog rau kev ua haujlwm: $300–380. Tshaj li 42- txee xa tawm, qhov sib txawv sib xyaw ua ke rau tsib- daim duab txuag ntawm kev teeb tsa ib leeg, ua ntej suav rau lub sijhawm-tus nqi ntawm kev ua haujlwm sai.

Cov ntaub ntawv ntawm cov neeg siv khoom:Ib tus neeg siv khoom Glory Optics siv 2,400-fiber MPO teeb tsa cabling kev teeb tsa hauv Tier III colocation facility tau sau tseg 62% txo qis hauv kev teeb tsa lub sijhawm ua haujlwm piv rau kev sib piv cov cuab yeej cuab tam LC vaj huam sib luag hauv thaj chaw uas nyob ib sab ua tau 18 lub hlis dhau los. Cov ntaub ntawv kawm tiav muaj nyob hauv NDA.

 

Kev teeb tsa, kev txheeb xyuas polarity, thiab kev daws teeb meem

Feem ntau ntawm MPO thaj vaj huam sib luag teeb meem uas tsim daim pib txhawb nqa - kwv yees80% ntawm kev tshaj tawm txuas tsis ua haujlwmnyob rau hauv cov qauv MPO cabling - yog tshwm sim los ntawm ob yam kev tiv thaiv: polarity tsis raug ntawm commissioning, thiab qias neeg connector kawg - ntsej muag. Tsis yog yuav tsum tau hloov kho kho vajtse los kho, tab sis ob leeg xav tau kev txiav txim siab ua haujlwm los tiv thaiv.

 

Kauj ruam -los ntawm - kauj ruam vaj huam sib luag mounting thiab cable tswj

  1. Paub meej txoj kev polarity ua ntej racking:Saib xyuas koj qhov kev xav tau ntawm transceiver polarity (feem ntau nyob rau hauv tus neeg muag khoom hloov kho qhov muag pom kev pom zoo qhia). Xaiv hom cassette sib xws (A, B, lossis C) los ntawm koj qhov kev txiav txim.
  2. Nruab lub vaj huam sib luag chassis hauv khib:Rack nrog M6 screws. Tsis txhob overtighten - vaj huam sib luag vaj huam sib luag yog ntsuas rau 1U khib load tab sis ntau dhau torque tuaj yeem cuam tshuam cov cassette alignment slots.
  3. Insert cassettes:Cassettes nyem rau hauv lub vaj huam sib luag pem hauv ntej; tsis muaj cuab yeej yuav tsum tau. Txhua lub cassette yog qhov tseem ceeb los tiv thaiv kev nkag mus rau qhov tsis ncaj ncees lawm.
  4. Txoj kab hauv qab mus rau MPO cov chaw nres nkoj:Khaws ciayam tsawg kawg nkaus 38 hli (1.5 nti) khoov vojvoograu MPO lub cev cables ntawm tag nrho cov routing point. Khoov vojvoog ua txhaum cai yog thawj qhov ua rau rov qab poob degradation nyob rau hauv deployed panels.
  5. Cap tag nrho cov chaw nres nkoj tsis sivnrog rau cov khoom siv plua plav plua plav ua ntej ua haujlwm. Txhua qhov chaw nres nkoj MPO tsis muaj kev sib kis yog txoj hauv kev sib kis mus rau lub ferrule nquag.
  6. Sau tag nrho cov chaw nres nkojthaum lub sij hawm installation. Re-labeling tom qab cov pej xeem cable yog qhov nyuaj dua thiab nquag ncua, tsim kev tsim kho tsis tau.

Cable slack tswj nyob rau hauv siab -nruj configurations

Hauv cov neeg uas muaj 144- fiber ntau 1U vaj huam sib luag nrog rau 24- fiber ntau MPO lub cev, lub nraub qaum ntawm lub vaj huam sib luag tuav rau rau 24- fiber ntau cables nrog rau kev sib txuas sab nraud ntawm kwv yees li 85mm. Glory Optics 2U thiab 4U zawv zawg-tub rau khoom vaj huam sib luag suav nrog kev sib xyaw ua ke ntawm kev tswj hwm hauv qab nrog cov hlua khi. Rau 1U panels nyob rau hauv high-density racks, nruab ib tug 0.5U cable tswj bar ncaj qha rau hauv qab lub vaj huam sib luag rau txoj kab cords horizontally ua ntej lawv nkag mus rau ntsug cable managers.

 

Polarity xeem raws tu qauv

Tom qab kev teeb tsa, txheeb xyuas qhov polarity nrog lub teeb pom kev zoo (VLS / laser liab) ua ntej txuas cov khoom siv nyob. Ib qho yooj yim kawg-rau-kawg loopback kuaj pom tseeb fiber ntau txuas ntxiv thiab tag nrho polarity. Rau kev txheeb xyuas nyiaj txiag tag nrho, siv lub teeb pom kev zoo thiab lub ntsuas hluav taws xob kho qhov muag (LS/OPM) teeb. Kev sim OTDR tsis tas yuav tsum muaj rau lub Hoobkas ua ntej- txiav cov kab ke sib txuas thiab ntxiv qhov nyuaj uas tsis tsim nyog.

Glory Optics Hoobkas ua ntej- txheej txheem xeem

Txhua MPO cassette xa los ntawm Glory Optics tau 100% sim siv lub Hoobkas raws li hauv qab no:ISO 9001: 2015 cov txheej txheem tsim khoom

  1. 3D interferometry kawg-kev tshuaj xyuas lub ntsej muag - lees paub ferrule geometry, rov poob, thiab nto tiav ua ntej mating
  2. Insertion poob ntsuas ntawm 850 nm (MM) / 1310 nm (SM) - cov txiaj ntsig tau kaw ib fiber ntau rau ib qhov chaw nres nkoj
  3. Polarity continuity check - lees paub qhov tseeb fiber ntau daim phiaj qhia rau hom A/B/C cassette
  4. Kev soj ntsuam zaum kawg thiab daim ntawv thov plua plav

Daim ntawv tshaj tawm kev xeem batch (PDF, chaw nres nkoj-los ntawm-port IL rooj) suav nrog hauv cov khoom xa tuaj. Qhov no tshem tawm qhov kev xav tau ntawm kev tshuaj ntsuam xyuas thaum tuaj txog thiab tso cai rau kev teeb tsa ncaj qha -theem sim raws li lub hauv paus.

 

Kev tu huv

Ntxuav MPO connector kawg -ntsej muag ua ntej txhua mating.Ib -nias cov tshuaj ntxuav(piv txwv li, Fujikura CT-30 MPO lossis sib npaug) yog qhov zoo dua rau kev siv vaj huam sib luag - lawv siv lub zog tu zoo ib yam yam tsis tas yuav tsum muaj tus kws tshaj lij los ntsuas lawv cov txheej txheem. Reel cleaners yog siv tau rau kev saib xyuas ib ntus tab sis tsis yog rau kev siv hauv khib nyiab uas nkag mus tau txwv. Kev tu ntau zaus: ntxuav ua ntej kev sib txuas thawj zaug, thiab tom qab muaj kev cuam tshuam kev sib txuas uas tawm ntawm lub ferrule tsis muaj kev cuam tshuam rau ntau tshaj 30 feeb.

 

Cov ntaub ntawv xa mus rau kev tshawb fawb - tiag-world MPO thaj vaj huam sib luag cov ntaub ntawv ua haujlwm

Cov ntaub ntawv hauv qab no yog kos los ntawm Glory Optics cov neeg siv khoom xa tawm. Cov npe ntawm cov neeg siv khoom tshwj xeeb thiab thaj chaw raug txiav tawm raws li NDA kev pom zoo; Cov ntaub ntawv kawm tag nrho muaj nyob rau cov neeg tsim nyog tau txais kev pab thaum thov.

Case Study 1 - Hyperscale AI Cluster, Asia Pacific
 

400G txha nraub qaum- nplooj hloov kho: 2,400-fiber MPO xa tawm hla 48 racks

Lub chaw muab kev pabcuam huab nthuav dav GPU pawg muaj peev xwm los ntawm 100G txog 400G rau ib lub chaw nres nkoj server xaiv Glory Optics 1U MPO-16 vaj huam sib luag (OM4, MTP Elite) rau cov txheej txheem cabling tag nrho hla lub pod tshiab ntawm 48 racks. Kev xa tawm tau siv ua ntej- txiav tawm MPO-16 lub cev cables nrog rau hauv lub vaj huam sib luag cassettes tawg rau LC duplex ntawm server NIC kev sib txuas.

Ntsuas cov txiaj ntsig vs yav dhau los LC kev teeb tsa cabling xa tawm:

Lub sij hawm txhim kho: 3 hnub (vs 8 hnub kwv yees rau daim teb-tawm) Link yuam kev tus nqi: 0.001% post-commissioning (vs 0.03% nyob rau hauv legacy LC cheeb tsam) Cov sij hawm ua haujlwm tau txais kev cawmdim: 62% txo qis vs teb- txiav tawm kwv yees Zero vaj huam sib luag- theem ua txhaum ntawm 6 lub hlis tshuaj xyuas
Case Study 2 - Colocation Provider, Europe

High-density 144-fiber-per-1U kev xa tawm daws cov txee kub ceev

Ib tug European Tier III colocation tus neeg teb xov tooj tsiv mus rau 200-txheej nrog rau ntawm 10G LC infrastructure mus rau 100G MPO qauv cabling ntsib ib qho teeb meem thib ob: tsoos LC cabling bundles ntawm 100G qhov ntom ntom tau thaiv cov cua ntws thiab nce qhov hluav taws xob kub hauv cov khoom nyob ib sab los ntawm 3-5℃hauv kab cuam tshuam. Hloov mus rau 1U MPO-24 panels (6 × 24-fiber rear ports) txo qhov pom cov kab hluav taws xob hauv qab ntawm cov vaj huam sib luag los ntawm kwv yees li 40% piv rau qhov sib npaug ntawm LC breakout cabling, ntsuas cov cua ntws mus rau qhov tshwj xeeb.

Cable bundles txoj kab uas hla: ~ 40% Txee qhov hluav taws xob kub delta: rov qab mus rau hauv paus hauv 30 hnub Cov ntaub ntawv ua raws: RoHS 3, REACH SVHC, CE DoC
Case Study 3 - Telecommunications Carrier, Western Europe

LSZH ua raws li kev soj ntsuam thiab cov ntaub ntawv pob rau lub teb chaws tsim - tawm

Ib tus neeg nqa khoom nyob sab Europe siv MPO thaj vaj huam sib luag hauv 140 Cov Ntsiab Lus ntawm Kev Pom Zoo thoob plaws peb lub tebchaws yuav tsum tau ua tiav cov ntaub ntawv ua raws li pob khoom sib xws nrog lawv cov kev tshawb xyuas kev yuav khoom. Glory Optics muab:RoHS 3 (EU 2015/863) tshaj tawm, REACH SVHC nqe lus (cov npe neeg sib tw tam sim no), CE Daim Ntawv Tshaj Tawm Txog Kev Ua Raws Cai, thiab LSZH cov ntaub ntawv pov thawj rau EN 60332-3-24. Tag nrho cov ntaub ntawv tau muab tso rau hauv cov hom ntawv (PDF, tshuab-nyeem tau) nyob rau hauv thawj lub sijhawm ua khoom lag luam, tso cai rau cov neeg nqa khoom yuav ua tiav lawv cov kev soj ntsuam ua ntej ua ntej xa lub cev.

140 PoP qhov chaw muab ntau tshaj 8 lub hlis Tag nrho cov ntaub ntawv ua raws cai: xa nrog thawj pawg Zero cov ntaub ntawv- cuam tshuam txog kev yuav khoom qeeb
 

Kev cai MPO thaj vaj huam sib luag daws teeb meem - OEM, tsis yog - qauv teeb tsa, thiab lub sijhawm ua haujlwm ceev

 

Standard catalog configurations npog feem ntau ntawm cov ntaub ntawv chaw deployments. Tab sis cov xwm txheej uas tseem ceeb tshaj plaws rau lub sijhawm ncua sij hawm - qhov chaw nres nkoj txawv txawv, cov xim muaj tswv yim -coding scheme, OEM ntiag tug- daim ntawv lo yuav tsum, lossis 72- teev cov ntawv thov xwm txheej ceev - yog qhov twg Glory Optics 'ISO 9001: 2015ntau lawm system yog tsim los flex.

 

Customization xaiv

  • Chaw nres nkoj suav:Tsis yog -tus qauv chaw nres nkoj suav (piv txwv li, 8-chaw nres nkoj, 10-chaw nres nkoj, 18-chaw nres nkoj) rau kev hloov tshwj xeeb lossis cov hneev taw router, tsis tas yuav tsum muaj 1U chassis.
  • Hom Adapter:SC, ST, FC, E2000, los yog MPO-rau-MPO dhau- los ntawm cov hloov pauv hloov pauv hauv cov vaj tsev txheem.
  • Xim coding:Kev cai RAL xim panels thiab cassette lub cev rau cheeb tsam - qhia nyob rau hauv loj - scale deployments.
  • Label printing:Factory- siv laser engraving ntawm vaj huam sib luag faceplates rau chaw nres nkoj IDs, zone codes, los yog cov neeg siv khoom- teev npe.
  • Cable sib dhos Length:Ua ntej- txiav cov trunks nyob rau hauv uas tsis yog - tus qauv ntev (1.5 m, 3.5 m, 7 m, thiab lwm yam) kom phim cov racks tshwj xeeb.
  • OEM ntiag tug-label:Tag nrho dawb - daim ntawv ntim thiab kev cai lub npe rau cov neeg muag khoom thiab cov neeg koom ua ke. MOQ 10 units; tsis muaj nqi NRE rau kev hloov kho vaj tse.
  •  

Kev cog lus ua ntej lub sijhawm

Txheem catalog MPO thaj panels nkoj hauv5-7 hnub ua haujlwm. Rau cov khoom tsim khoom (1U MPO-12 / OM4, 1U MPO-24 / OM4, 2U MPO-12 / OS2),72-teev nthuav dav xa tawmmuaj rau kev txiav txim qis dua 50 units. Kev cai configurations uas tsis yog -txheej txheem cassette thaiv los yog hloov faceplate nqa lub sij hawm 10-14 hnub.

Ntawm - lub sij hawm xa tuaj tus nqi: 97.8%hla 3,200+ xaj taug qab nyob rau lub sijhawm 24-lub hlis xaus Q4 2025. Daim duab no tau raug tshuaj xyuas tawm tsam cov hnub nkoj uas tau lees paub hauv peb cov ERP system raws li ISO 9001: 2015 cov ntaub ntawv tswj xyuas zoo.

 

Cov txheej txheem kev ruaj ntseg zoo

Txhua lub vaj huam sib luag Glory Optics - tus qauv lossis kev cai - dhau los ntawm tib yamISO 9001: 2015ntau lawm thiab kev xeem khiav: kev tshuaj xyuas cov ntaub ntawv (ferrule geometry, fiber ntau geometry, vaj tse seem check), ntau lawm -theem IPC tshuaj xyuas, 100% kev ntsuas qhov poob los ntawm 3D interferometry, polarity check, kev tshuaj xyuas qhov muag, thiab cov ntaub ntawv tawm mus. Kev cai OEM xaj kuj tau txais thawj - tsab xov xwm tshuaj xyuas rau thawj pawg.

 

Xav tau kev cai configuration?

Upload koj BOM lossis piav qhia koj qhov kev qhia tshwj xeeb. Peb pab neeg ua haujlwm engineering teb nrog kev pom zoo thiab hais lus hauv 4 teev ua haujlwm. OEM txiav txim yam tsawg kawg nkaus: 10 units.

 

Cov lus nug nquag nug - MPO fiber ntau thaj vaj huam sib luag

Q: Qhov txawv ntawm MPO thiab MTP thaj vaj huam sib luag yog dab tsi?

A: MPO (Multi-fiber Push-On) yog tus qauv txuas txuas dav dav txhais los ntawm IEC 61754-7, tsim los ntawm ntau tus neeg muag khoom. MTP® yog lub npe lag luam rau US Conec lub siab -kev ua tau zoo MPO connector, featuring nruj ferrule kam rau ua, ib tug tshem tau vaj tse uas tso cai rau kev hloov ntawm poj niam txiv neej nyob rau hauv lub teb, thiab optimized lub caij nplooj ntoos hlav quab yuam nyob rau hauv ib txwm mating. MTP yog mechanically interchangeable nrog MPO - ob qho tib si khub niam txiv kom raug nyob rau hauv lub tes tsho adapter - tab sis MTP muab qis dua qhov poob thiab ntau dua rov qab poob. Glory Optics panels siv tiag US Conec MTP® connectors nyob rau hauv tag nrho cov qauv thiab cov neeg tseem ceeb configuration.

Q: Kuv puas tuaj yeem siv MPO-12 vaj huam sib luag rau 400G daim ntawv thov?

A: Nws nyob ntawm 400G transceiver hom. 400G-SR8 thiab 400G-DR8 xav tau MPO-16 connectors thiab siv tsis tau MPO-12 vaj huam sib luag - ferrule pin suav yog lub cev tsis sib haum{{10.GFR4}G{10. thiab 400G-LR4 transceivers siv LC duplex lossis MPO-12 interfaces thiab tau tshaj MPO-12 vaj huam sib luag. Xyuas koj lub transceiver hom interface tiv thaiv IEEE 802.3cd (SR8 / DR8) lossis 802.3bs (FR4 / LR4) ua ntej xaj panels.

Q: Muaj pes tsawg fibers puas 1U siab - ntom MPO thaj vaj huam sib luag tuav?

A: 1U MPO thaj vaj huam sib luag tuav ntawm 72 thiab 144 fibers nyob ntawm seb hom cassette. Siv rau MPO-12 lub xov tooj (12 fibers txhua), tag nrho yog 72 fibers. Siv rau MPO-24 daim ntawv (24 fibers txhua) nrog plaub-LC pem hauv ntej adapters, tag nrho ncav cuag 144 fibers - uas yog 6 × fiber ntau ntom ntawm tus qauv 1U LC duplex vaj huam sib luag. Glory Optics muaj ob qho kev teeb tsa nrog OM3, OM4, thiab OS2 fiber ntau sib txawv.

Q: Kuv yuav tsum xav li cas los ntawm lub vaj huam sib luag MPO zoo?

A: IEC 61754-7 teeb tsa kev ua raws hauv pem teb ntawm Tsawg dua lossis sib npaug rau 0.5 dB rau cov qauv MPO connectors. Lub vaj huam sib luag MPO zoo siv US Conec MTP® cov khoom sib txuas yuav tsum xa cov khoom nruab nrab ntawm Tsawg dua lossis sib npaug li 0.35 dB, nrog rau qib MTP Cov Neeg tseem ceeb ncav cuag Tsawg dua lossis sib npaug li 0.25 dB. Glory Optics Hoobkas cov ntaub ntawv (3D interferometry, 100% kuaj) qhia qhov nruab nrab ntawm 0.31 dB rau tus qauv MTP thiab 0.22 dB rau MTP Cov Neeg Tseem Ceeb. Ib txwm thov ib daim ntawv qhia txog kev xeem ntawm lub Hoobkas - txhua tus neeg muag khoom uas tsis tuaj yeem muab cov ntaub ntawv poob qis rau qhov chaw nres nkoj rau lawv cov vaj huam sib luag yog nyob ntawm IEC spec pem teb, tsis ntsuas kev ua tau zoo.

Q: Dab tsi yog qhov txawv ntawm ODF thiab fiber ntau thaj vaj huam sib luag?

A: Ib qho ODF (Optical Distribution Frame) yog tsim los rau sab nraud - cog thiab ntev - tshem tawm cov kab hluav taws xob siv kev sib tshuam. Nws yog qhov loj chassis vaj tsev fusion splice tais thiab pigtails, haum rau kev sib txuas mus tas li hauv cov ntsiab lus nkag hauv tsev thiab MDFs. MPO fiber ntau thaj vaj huam sib luag yog ua ntej- txiav tawm, ntsaws- thiab- ua si chav tsev rau kev teeb tsa hauv -cov ntaub ntawv- nruab nrab cabling. Nws yooj yim dua rau kev xa tawm (tsis muaj splicing), qhov ceev dua (txog 144 fibers ib 1U), thiab txhawb kev rov ua dua tshiab - thaj ua rau thaj. Rau cov ntaub ntawv chaw kab - theem thiab khib- theem kev tsim kho, MPO thaj vaj huam sib luag yog qhov kev xaiv raug; ODFs ua haujlwm rau sab nraud- cog thiab tsim lub hauv paus caj dab.

Q: Koj puas muab RoHS thiab CE daim ntawv ntsuam xyuas nrog txhua qhov kev txiav txim?

A: Yog. Cov ntaub ntawv txheej txheem nrog txhua qhov Glory Optics MPO thaj vaj huam sib luag muaj xws li: Daim ntawv tshaj tawm kev poob ntawm lub Hoobkas (ib qhov chaw nres nkoj, 3D interferometry), RoHS 3 (EU 2015/863) Kev tshaj tawm ua raws, thiab CE Daim Ntawv Tshaj Tawm Txog Kev Ua Raws Cai. REACH SVHC daim ntawv tshaj tawm thiab ISO 9001: 2015 daim ntawv pov thawj (nrog rau daim ntawv pov thawj naj npawb) muaj nyob rau ntawm kev thov rau OEM cov neeg siv khoom thiab cov kev xav tau ntawm kev soj ntsuam. LSZH cov ntaub ntawv pov thawj rau EN 60332-3-24 yog muaj rau cov neeg nqa khoom nyob sab Europe thiab tsoomfwv xa mus.

Q: Koj qhov kev txiav txim yam tsawg kawg nkaus yog dab tsi rau kev cai configurations?

A: Qhov tsawg kawg nkaus txiav txim kom muaj nuj nqis rau kev cai MPO thaj vaj huam sib luag configurations yog 10 units. Tsis muaj NRE (tsis yog- rov ua haujlwm engineering) tus nqi rau kev hloov kho vaj tse qauv xws li kev suav chaw nres nkoj, hloov hom hloov pauv, lossis xim coding. OEM ntiag tug- daim ntawv ntim (kev cai lub npe, laser-engraved faceplates) kuj pib ntawm 10 units MOQ. Lub sijhawm ua haujlwm rau kev teeb tsa kev cai yog 10-14 hnub ua haujlwm.

Xa kev nug