MTP/MPO-8 vs MTP/MPO-16 Cov Khaub Ncaws: Koj Yuav Tsum Xaiv Qhov twg rau Koj Qhov Chaw 400G/800G Data Center?

Oct 05, 2026

Tso lus

Taw qhia

Kev xaiv ntawm 8-fiber thiab 16-fiber MTP / MPO harness pib nrog optical interface ntawm koj lub transceiver. Qhov chaw nres nkoj ceev ib leeg tsis qhia koj tias muaj pes tsawg fibers, connector twg, lossis qhov kev sib txuas ntawm qhov txuas xav tau dab tsi.

Rau cov pa sib txuas sib txuas nrog cov xaim sib cais thiab tau txais fiber ntau, plaub txoj kev kho qhov muag siv yim fibers, thaum yim txoj kev kho qhov muag siv kaum rau.MPO-16 muaj ib kab ntawm kaum rau fiber ntau txoj haujlwm (1 × 16).32-fiber configuration siv ob kab ntawm kaum rau (2 × 16), raws li teev nyob rau hauvUS Conec's fiber-preparation specifications.

Phau ntawv qhia no piav qhia yuav ua li cas los sib piv ob txoj kev xaiv cabling, tshawb xyuas kev sib raug zoo, thiab npaj cov hlua khi kom raug rau koj qhov project.

Qhov 8-fiber thiab 16-fiber labels txhais li cas

MPO yog ib hom multifiber connector; MTP® yog US Conec hom ntawm MPO connector. Ib txoj hlua khi faib cov fibers los ntawm cov khoom sib txuas rau ib tus neeg txuas lossis cov pab pawg me. Piv txwv li, MPO-rau-LC harness, tuaj yeem nthuav tawm cov fibers li duplex LC khub. Ib txoj hlua hloov dua siab tshiab tuaj yeem faib lawv ntawm ntau yam MPO connectors.

Hauv kev siv Base-8 SR4 thiab DR4, yim lub zog fibers tuav txoj haujlwm 1-4 thiab 9-12 ntawm ib kab, 12-txoj haujlwm MPO interface. Lub chaw plaub txoj haujlwm tsis siv los ntawm qhov txuas kho qhov muag. Ib qho 8-fiber cable sib dhos thiab muaj cov neeg tuaj yeem 12-fiber sib dhos yog li ntawd muaj ntau cov fiber ntau suav txawm tias lawv siv tib tsev neeg sib txuas.HPE Aruba's connector guidepiav qhov txawv no.

MPO-16 siv ib kab ntawm kaum rau txoj haujlwm thiab tus yuam sij offset. Qhov sib txuam MPO-12 interface siv tus yuam sij hauv nruab nrab. Cov no yog qhov sib txawv mating interfaces: tus qauv MPO-12 ntsaws tsis tuaj yeem hloov ncaj qha rau MPO-16 ntsaws. SENKO tseem sau cov ntaub ntawv sib txawv hauv lawv cov lus qhia-pin geometry hauv nwsDaim ntawv thov MPO Cov Kev Cai Zoo Tshaj Plaws.

Thaum thov cov lus hais, qhia ob qho tib si cov naj npawb ntawm cov neeg siv fiber ntau thiab cov khoom sib txuas ntawm txhua qhov kawg. Ib qho kev thov rau "8-fiber MPO cable" ib leeg tawm hauv kev nkag siab yuam kev.

MTP/MPO-8 thiab MTP/MPO-16 piv

Xaiv point 8-fiber Base-8 hlua 16-fiber MPO-16 hlua
Populated fibers 8 16
Common connector kev npaj Yim txoj haujlwm nquag hauv ib kab MPO-12 interface Kaum rau txoj haujlwm hauv ib kab: 1 × 16
Kev teeb tsa tseem ceeb Lub hauv paus tseem ceeb ntawm MPO-12 interface Offset yuam sij ntawm MPO-16 interface
Sib cais-fiber parallel ua haujlwm 4 xa cov fibers thiab 4 tau txais fibers 8 xa cov fibers thiab 8 tau txais fibers
LC fan-out configuration Plaub duplex khub, thaum txiav txim nyob rau hauv no configuration Yim duplex khub, thaum txiav txim nyob rau hauv no configuration
Piv txwv daim ntawv thov 400G DR4 siv ib qho MPO-12 interface 400G SR8 siv ib qho MPO-16 interface
Yav tom ntej rov siv dua Nyob ntawm tus transceiver tom ntej thiab ua tiav channel specification Nyob ntawm tus transceiver tom ntej thiab ua tiav channel specification

Cov lus piav qhia txog kev teeb tsa ib txwm muaj. Paub meej tias qhov tseeb connector kos duab, fiber ntau daim ntawv qhia, thiab transceiver yuav tsum ua ntej xaj. Fiber suav tsis tsim kom muaj kev sib haum xeeb ntawm nws tus kheej.

Xaiv ib txoj hlua khi rau 400G

Ob lub 400G transceivers tuaj yeem xav tau sib txawv cabling. Cisco's QDD-400G-DR4-S siv MPO-12 APC ib hom kev sib txuas, thaum nws QDD-400G-SR8-S siv MPO-16 APC multimode interface. Ob leeg nqa 400G, tab sis lawv txawv ntawm fiber ntau, hom fiber ntau, thiab kho qhov muag architecture. Cov kev teeb tsa no tau sau tseg hauvCisco's 400G QSFP-DD data sheet.

Xaiv yim-fiber sib dhos thaum lub teeb pom kev zoo interface siv plaub kis thiab plaub tau txais fibers. Xaiv ib qho kev sib dhos MPO-16 thaum lub interface tau teev tseg yuav tsum muaj kaum rau fibers hauv ib qho MPO-16 connector. Tom qab ntawd xaiv qhov kev txiav tawm nyob deb kom phim qhov kev sib txuas uas xav tau: lwm qhov sib txuas-optics interface, lub cassette, lossis kev txhawb nqa duplex breakout ports.

Ib tug passive hlua txoj kev fibers; nws tsis hloov wavelengths, hloov cov qauv qauv, lossis pab kom tsis muaj kev txhawb nqa hloov pauv hloov hom. Rau qhov kev thov 400G-rau-4 × 100G kev twb kev txuas, xyuas qhov tseeb transceivers ntawm ob qho kawg thiab tus tswv platform qhov kev txhawb nqa chaw nres nkoj.

Puas yog 800G xav tau MPO-16?

800G cov khoom siv ntau qhov chaw kho qhov muag. Piv txwv li, NVIDIA's MMS4A20 800G DR4 transceiver siv plaub-channel MPO-12/APC kev twb kev txuas. Nwscov ntaub ntawv khoomqhia tau hais tias tus qauv 800G tuaj yeem siv Base-8 fiber ntau.

Cisco muaj lwm qhov kev sib piv muaj txiaj ntsig: nws OSFP-800G-DR8 siv ob lub MPO-12 txuas, thaum nws OSFP-800G-DR8P siv ib qho MPO-16 txuas. Ob leeg muab yim khub ntawm ib hom fibers, faib thoob plaws kev sib txuas sib txuas. Saib covCisco OSFP 800G data sheet.

Rau kev yuav khoom, sau tag nrho cov transceiver ib feem nrog rau qhov nominal ceev. "800G OSFP" tsis yog qhov ua tiav cable specification. Tib lub hauv paus ntsiab lus siv rau yav tom ntej 1.6T kev hloov kho tshiab: rov siv dua yuav tsum tau kuaj xyuas cov optics xaiv, hom fiber ntau, ncav cuag, txuas txuas, thiab cov peev nyiaj poob.

Muab piv cov vaj huam sib luag ntom ntom thiab tus nqi

Lub peev xwm fiber ntau tuaj yeem suav ncaj qha thaum lub vaj huam sib luag siv tau thiab cov kev teeb tsa sib dhos tau paub. Xav txog kev teeb tsa vaj huam sib luag nrog 48 txoj haujlwm sib xws:

Kev teeb tsa Kev suav Txuas fibers
48 yim-fiber sib dhos 48 × 8 384
48 kaum rau-fiber sib dhos 48 × 16 768
24 kaum rau-fiber sib dhos 24 × 16 384

Qhov no yog ib qho piv txwv ntawm fiber ntau, tsis yog ib qho kev qhia tshwj xeeb rau lub vaj huam sib luag Glory. Txheeb xyuas cov chassis uas tau xaiv, adapter modules, cable nkag, thiab khoov-radius yuav tsum ua ntej muab cov chaw nres nkoj suav rau hauv chav tsev khib.

Sib piv cov nqi tsim khoom siv cov khoom siv ua tiav: cov hlua khi, lub cev, cov khoom siv hluav taws xob, cov khoom siv, kev teeb tsa, thiab kev sim. Kuj suav rau ib qho kev sib txuas ntxiv uas tau qhia los ntawm cov rooj sib tham hloov dua siab tshiab. Ntau fibers ntawm lub vaj huam sib luag txoj hauj lwm tsis, ntawm lawv tus kheej, tsim kom muaj bandwidth siv tau los yog txo tus nqi ntawm kev sib txuas ua haujlwm.

Rov siv dua Base-8 cabling uas twb muaj lawm

Ib qho MPO-16-rau-ob-Base-8 hloov dua siab tshiab sib dhos tuaj yeem pab rov qab siv cov kev teeb tsa fiber ntau thaum nws daim duab qhia sib tw rau qhov txuas uas xav tau. Nqa tag nrho kaum rau fibers yuav tsum muaj ob txoj kev muaj yim-fiber. Ib txoj hlua hloov dua siab tshiab tsis tuaj yeem tig ib txoj kev yim-fiber rau hauv kaum rau txoj kev ywj pheej fiber ntau.

Ua ntej xaiv txoj hauv kev no, sau txhua txoj hauv kev uas twb muaj lawm thiab xyuas:

  • Fiber hom, ntsia ntev, thiab ntsuas qhov xwm txheej.
  • Connector interfaces, kawg-lub ntsej muag polish, qhia pins, thiab adapter compatibility.
  • Xaus-rau-kawg fiber ntau daim ntawv qhia los ntawm txhua lub cev, cassette, thiab hlua.
  • Tag nrho cov channel nkag tsis tau, suav nrog kev sib txuas ntxiv.
  • Txhawb kev ua haujlwm transceiver thiab hloov breakout configuration.

Siv daim duab txuas ua tiav los txiav txim seb qhov kev hloov pauv yog qhov siv tau lossis xav tau lub pob tw tshiab. Hloov LC adapters nrog me dua duplex connectors tuaj yeem ua kom lub vaj huam sib luag ntom ntom, tab sis nws tsis ntxiv cov fibers rau ib qho cable uas twb muaj lawm.

Cov ntsiab lus kom muaj nyob rau hauv ib lub sam thiaj specification

Polarity thiab daim ntawv qhia.Qhia meej qhov chaw fiber ntau ntawm ib kawg txuas rau txhua txoj haujlwm ntawm lwm qhov kawg, suav nrog kev txiav txim ntawm LC ceg. Hom A, B, lossis C cov ntawv tuaj yeem piav qhia txog ib tus neeg sibtham, tab sis tag nrho cov channel tseem xav tau txoj hauv kev sib kis-rau-tau txais. Thov ib daim duab kos duab rau kev hloov dua siab tshiab harnesses thiab mixed cabling systems.

Connector interface thiab poj niam txiv neej.Txheeb xyuas MPO-12 lossis MPO-16, qhov kev npaj tseem ceeb, thiab pinned lossis unpinned connectors ntawm txhua qhov sib txuas. Txhua MPO mating khub yuav tsum tau sib haum xeeb nta; xyuas cov khoom specification es tsis txhob xav tias txhua qhov chaw nres nkoj zoo ib yam.

Polish thiab fiber ntau hom.Paub meej tias APC lossis PC / UPC qhov twg muaj feem xyuam, ua ke nrog rau qhov xav tau ib hom lossis ntau hom fiber ntau. Sib piv cov mating interfaces thiab optics. Cable lossis vaj tsev xim ib leeg tsis txaus los tsim kom muaj kev sib haum xeeb.

Dimensions thiab installation.Qhia meej tag nrho cov kab ntev, qhov ntev ntawm qhov ntev, kev sau npe, kev txwv kev txwv, thiab kev faib lub tsho xav tau los ntawm qhov project. suav nrog qhov ntau thiab qhov chaw xa khoom kom tus neeg muag khoom tuaj yeem npaj cov lus hais siv tau.

Cov ntaub ntawv lees paub.Thov daim duab kos duab sib dhos, daim ntawv qhia fiber ntau, thiab cov txiaj ntsig ntawm qhov tsis pom zoo rau cov kev txwv. Cov no muab lub hauv paus meej rau kev lees paub dua li kev thov dav dav ntawm kev sib raug zoo nrog cov ntaub ntawv tus nqi.

Thov kev teeb tsa txoj cai los ntawm Glory Optical

Tshawb nrhiav Glory Optical'sMTP / MPO kab txuasthiab xa cov kev muag khoom pab neeg koj transceiver ib feem naj npawb thiab daim duab txuas. Xws li hom fiber ntau, connector interfaces, pin configuration, polarity map, cable thiab ceg lengths, kom muaj nuj nqis, thiab lo lus uas peb.

Rau ib qho kev teeb tsa uas twb muaj lawm, ntxiv lub cev tshwj xeeb thiab muaj fiber ntau suav. Qhov no yuav pab kom paub qhov txawv ntawm qhov kev xav tau ntawm cov hlua ncaj nraim los ntawm qhov project uas tseem xav tau kev sib hloov pauv los yog hloov mus rau lub nraub qaum.

Thov ib qho MTP / MPO cov lus haisnrog rau cov ntsiab lus no kom lub rooj sib txoos tuaj yeem kuaj xyuas koj qhov txuas tiag tiag.

Cov lus nug uas nquag nug

Puas yog MPO-16 teem rau ob kab?

16-fiber configuration yog ib kab ntawm kaum rau, los yog 1 × 16. US Conec teev cov 32-fiber configuration li 2 × 16.

Ib qho MPO-16 connector puas tuaj yeem txuas ncaj qha rau hauv MPO-12 adapter?

Cov interfaces siv sib txawv keying thiab mating geometry. Siv lub adapter uas tau teev tseg thiab lub rooj sib txoos hloov pauv uas tsim nyog qhov kev sib txuas tsim yuav tsum muaj kev hloov pauv ntawm cov tsev neeg txuas.

Puas yuav MPO-rau-LC hlua khi kom muaj kev sib txuas?

Breakout yuav tsum tau tshaj optics thiab tus tswv tsev txhawb nqa nrog rau qhov tseeb fiber ntau daim ntawv qhia. Txheeb xyuas cov kev cai no ua ntej xaiv cov hlua.

MTP® yog ib lub cim lag luam ntawm US Conec Ltd.

Xa kev nug