Cov lus teb ceev
IbODN fiber ntau optic tovtsis yog ib qho khoom lag luam - nws yog txoj hauv kev ua tiav los ntawm OLT mus rau ONT, ua hauv peb ntu ua haujlwm. Covfeedertxheej khiav siab - suav G.652D sab nraum zoov cable los ntawm lub hauv paus chaw ua hauj lwm mus rau ib tug thawj node. Covkev faib tawmcov txheej txheem faib cov fibers los ntawm kev kaw, PLC splitters thiab FDB / NAP thawv rau cov neeg siv khoom. Covpoobtxheej yog khoov-insensitive G.657A2 cable rau txhua qhov chaw, xaus rau hauv lub thawv txiav, pigtail thiab phab ntsa qhov hluav taws xob. Tsim peb ntu ua ke, qhov loj ntawm qhov sib cais tawm tsam qhov kev sib txuas ntawm cov peev nyiaj, thiab khaws cia cov chaw nres nkoj kom ODN yooj yim dua los nthuav, sim thiab tswj tom qab hnub- ib qho kev ua kom tiav.
Phau ntawv qhia no kho ODN raws li ib qho kev tsim vaj tsev ib leeg es tsis yog ib daim ntawv teev npe. Tag nrho cov saw yogOLT / CO → feeder cable → splice kaw → PLC splitter → faib cable → FDB / NAP → poob cable → ONT. Txhua qhov ntawm cov saw hlau ntawd muaj cov haujlwm uas tau hais tseg, qhov chaw ntawm lub cev thiab ib thaj tsam xeem. Clear ciam teb ua teeb meem sai dua; Cov ntaub ntawv tsis meej chaw nres nkoj, cov ntsiab lus sib txuas ntxiv lossis cov khoom siv qias neeg ua rau thaj chaw sib cais nyuaj dua li qhov nws xav tau.
Siv nplooj ntawv no los hloov lub network topology rau hauv kev yuav khoom -npaj ODN BOM. Kev npaj qhov tseem ceeb xws li splitter insertion poob, connector-pair poob, IP ntsuam xyuas thiab cable tensile load tseem yuav tsum tau lees paub tiv thaiv cov ntaub ntawv cov khoom tiag, OLT / ONT specification thiab tus neeg teb xov tooj txoj cai txais.
ODN RFQ thiab BOM Input Checklist
Rau pawg neeg yuav khoom, txoj hauv kev nrawm tshaj plaws los hloov FTTH tsim rau hauv ODN daim nqi ntawm cov ntaub ntawv siv tau yog xa cov khoom siv hauv lub network hauv ib pob. Ib tus neeg muag khoom tsis tuaj yeem ua qhov loj me ntawm cov khoom siv cable, pob khoom splitter, FDB muaj peev xwm lossis poob - hom cable los ntawm cov neeg siv khoom suav ib leeg; txoj kev, cais txoj kev npaj thiab installation ib puag ncig yuav tsum tau soj ntsuam ua ke.
| Tswv yim los muab | Vim li cas thiaj tseem ceeb | Piv txwv hom |
|---|---|---|
| Txoj kev deb | Teem cov fiber ntau attenuation thiab pab kom paub meej tias seb qhov sib cais puas tuaj yeem nyob hauv cov peev nyiaj kho qhov muag. | Feeder 8 km + faib 1.5 km + poob 80 m |
| Cov neeg yuav khoom suav thiab ua - tus nqi hom phiaj | Txiav txim FDB/NAP chaw nres nkoj suav, splitter ratio, spare ports thiab spare fibers. | 320 lub tsev dhau mus, 45% hnub-ib qho kev ua haujlwm, 20% qhov muaj peev xwm |
| Split txoj kev npaj | Sib cais centralized 1:32 tsim los ntawm cascaded 1:4 × 1:8 los yog 1:8 × 1:8 tsim. | Tib-theem 1:32 lossis ob-theem 1:4 + 1:8 |
| Kev teeb tsa ib puag ncig | Hloov cov kev tsim kho cable, cov ntaub thaiv npog, qib sealing thiab mounting accessories. | Aerial ncej, underground duct, handhole, direct-faus los yog lub tsev riser |
| Kev sib txuas thiab kev xeem cov cai | Txhais pigtail, adapter, thaj - qaum thiab kev lees paub- cov cai xeem. | SC / APC, 1310/1550nm OLTS, OTDR kab, IEC 61300-3-35 kev tshuaj xyuas |
| OEM xav tau | Paub meej tias daim ntawv lo, ntim, cable luam ntawv, lub thawv xim lossis cov khoom siv yuav tsum tau kho. | Private daim ntawv lo, thawv cim, chaw nres nkoj daim ntawv lo, cov khoom siv los ntawm lub tsev |
Rau OEM / ODM ODN tej yaam num, Glory Optical tshuaj xyuas cov saw passive raws li ib tug matched teeb es tsis yog cais SKUs. Kev tshuaj xyuas ib txwm kuaj xyuas seb puas yog pob splitter, FDB lub tais muaj peev xwm, suav adapter, kaw kaw, poob -kab siv, chaw nres nkoj labeling thiab export ntim tag nrho ua raws li tib lub chaw nres nkoj daim ntawv qhia thiab txuas- kev xav txog nyiaj txiag. Cov nqi tsim khoom kawg yuav tsum tseem raug kaw los ntawm daim duab pom zoo, daim ntawv teev npe thiab ua ntej - cov ntaub ntawv xa khoom xa tuaj.
Kab lus no siv cov txiaj ntsig kev npaj rau kev sib tham thaum ntxov BOM. Kev pom zoo zaum kawg yuav tsum yog raws li xaiv OLT / ONT kho qhov muag chav kawm, cov ntaub ntawv cais cov ntaub ntawv, cable attenuation, ntsuas qhov txuas poob, cov ntaub ntawv splice thiab tus neeg teb xov tooj qhov kev lees paub. Qhov twg tus nqi raug cim ua piv txwv, tsis txhob luam nws ncaj qha rau hauv qhov project tsim yam tsis muaj kev suav rov qab.
Tag Nrho FTTH ODN Txuas: Los ntawm OLT rau ONT
Optical Distribution Network yog qhov passive ntawm PON ntawm OLT hauv lub chaw ua haujlwm hauv nruab nrab thiab ONT ntawm cov neeg siv khoom. Hauv kev npaj FTTH qhov ua tau zoo, nws yog thaj chaw - ua txoj hauv kev ua los ntawm cov khoom siv cable, splice kaw, PLC splitters, tis cable, FDB / NAP thawv, nco cable thiab subscriber - sab txiav. Vim tias txoj kev tsis muaj zog, nws nqa tsis muaj hluav taws xob hauv hluav taws xob los yog tswj hwm - tab sis txhua qhov sib txuas, qhov sib cais thiab cov txuas txuas txuas mus tas li siv ib feem ntawm cov peev nyiaj kho qhov muag. Tsis muaj downstream amplifier kom rov qab tau cov paj tau ploj mus rau qhov tsis tuaj yeem ntxiv mating point.

| Node | Kev ua haujlwm hauv ODN | Tej yam khoom xyaw | Qhov chaw kuaj xyuas zoo |
|---|---|---|---|
| OLT sab / CO | Active launch point; feeder fibers patched tawm ntawm ODF | ODF, feeder patching, optical ports | Chaw nres nkoj daim ntawv qhia thiab xa-cov ntaub ntawv fais fab rau ib qhov chaw nres nkoj PON |
| Feeder + thawj node | Kev thauj cov pob txha thiab thawj passive split los yog loj splice | Siab - suav cable sab nraum zoov, dome kaw, thawj PLC splitter | Splitter poob, input/output labels, kaw sealing, baseline OTDR |
| Distribution point | Txoj kev faib cov fibers mus rau pawg neeg siv khoom | Distribution cable, FDB / NAP lub thawv, xaiv lwm yam splitter | Chaw nres nkoj assignment, splice-tray routing, adapter cleanness, spare ports |
| Poob + qhov chaw nkag | Hloov ntawm sab nraum zoov poob mus rau sab subscriber | G.657A2 poob cable, txiav lub thawv, pigtail, phab ntsa qhov hluav taws xob | Khoov vojvoog, strain nyem, connector soj ntsuam ua ntej mating |
Feeder, Distribution and Drop: Yuav Ua Li Cas Peb Ntu Ua Haujlwm
Txoj hauv kev zoo tshaj plaws los xav txog kev daws teeb meem ODN yog los ntawm kev pheej hmoo ntawm kev siv tshuab, tsis yog los ntawm cov khoom npe. Txhua ntu ua haujlwm tsis sib txawv, yog li txhua qhov kev tsim kho sib txawv. Ib qho yuam kev engineering feem ntau yog xaj ib hom cable rau tag nrho txoj kev; lub feeder, faib thiab poob ntu txhua tus ntsib ib qho kev ntxhov siab tshwj xeeb.
Feeder txheej - thauj hauv qab nro
Lub feeder yog lub siab -fiber- suav qaum qaum los ntawm OLT/CO mus rau lub txee, thawj splice kaw lossis Fiber Distribution Hub.Corning sau ntawvuas tso lub splitter ntawm lub hauv paus hub cia qis dua - suav feeder pab ntau lub tsev, uas txo cov kev sib txuas ua haujlwm ua ntej thiab tsim lub sijhawm piv nrog cov neeg siv fiber ntau rau txhua tus neeg siv khoom. Qhov kev pheej hmoo tseem ceeb ntawm no yog tensile load thaum lub sij hawm rub thiab ntev - lub sij hawm ncua nro ntawm txoj kev dav hlau, yog li kev xaiv feeder yog tsav los ntawm kev suav fiber ntau, tensile ntsuam xyuas thiab duct lossis span condition. Glory Optical feem ntau qhia txog G.652D hauv GYXTW, GYTA lossis ADSS kev tsim kho rau ntu no.
Kev faib tawm txheej - routing thiab cov ntaub ntawv
Ntu kev faib khoom nqa cov fibers faib los ntawm lub hauv paus ntawm qhov tawm mus rau txoj kev -theem lossis lub tsev- nkag FDB/NAP lub thawv. Qhov no yog qhov chaw nres nkoj kev qhuab qhia nyob los yog tuag. Qhov kev pheej hmoo tseem ceeb tsis yog kev siv tshuab tab sis koom nrog: cov chaw nres nkoj tsis muaj npe, tsis muaj peev xwm thiab tsis zoo splice-tray routing. Ib qho modularfiber ntau lub thawv rau qhov kawg - mais nkagnrog reserved adapter ports yog dab tsi cia tus neeg teb xov tooj ntxiv cov neeg rau npe tom qab tsis muaj tag nrho cov node rov tsim dua.
Tso txheej - khoov- rhiab kawg ncua sij hawm
Qhov poob yog 1-4 fiber ntau khiav los ntawm FDB/NAP mus rau qhov chaw thiab yog qhov khoov tshaj plaws - thiab tuav - qhov tseem ceeb ntawm lub network. Phab ntsa nkag, clamps, rosettes thiab qhov kawg 90-degree tig tag nrho cov nruj khoov, uas yog vim li cas.ITU-T G.657khoov- muaj fiber ntau insensitive. Siv lub tiaj tus kheej -txhawb nqa rau luv luv aerial spans thiab round drops rau ducts thiab tiv thaiv underground txoj kev. Tus qauv tsim qauv yog G.652D nyob rau hauv feeder thiab tis network, ces G.657A2 los ntawm FDB rau cov neeg siv khoom.
| Ntu | Tseem ceeb txaus ntshai | Hom fiber ntau / cable | Xaiv xyuas |
|---|---|---|---|
| Feeder CO rau lub hauv paus node | Tensile load, ncua nro | G.652D, GYXTW / GYTA / ADSS, 12–144 fibers | Fiber suav, tensile ntsuam xyuas, spare qhov chaw, duct/span tsim |
| Kev faib tawm Thawj node rau FDB | Sealing, chaw nres nkoj cov ntaub ntawv, expansion | G.652D xoob-tube faib cable, 6-48 fibers | Cov neeg siv khoom ceev, cais cov phiaj xwm, cov chaw nres nkoj seem, lub thawv IP ntsuas |
| Tso FDB / NAP rau thaj chaw | Khoov, tuav kev puas tsuaj | G.657A2, 1-4 fibers, tiaj los yog puag ncig poob | Span/route type, tensile load, yam tsawg kawg nkaus khoov vojvoog, nkag lub kaum sab xis |
Split Ratio: Yuav ua li cas 1:8, 1:16, 1:32 thiab 1:64 Tsav Kev Pabcuam thiab Nyiaj Txiag
Split ratio yog ib qho kev txiav txim siab uas feem ntau cov khub niam txiv tau txais kev pab them nqi kho qhov muag. Nyob rau hauv cov nqe lus ntawm kev npaj, txhua txhua lub sij hawm tus naj npawb ntawm cov ceg doubles, lub splitter noj txog3dB ibntau optical zog. Qhov kev poob ntxiv ntawd yuav ntau cov neeg siv khoom ntawm OLT chaw nres nkoj, tab sis nws kuj tseem ua kom luv luv ntawm qhov siv tau thiab tawm tsawg dua rau cov khoom sib txuas, splices, kev laus thiab kho kom ruaj. Qhov no yog vim li cas qhov kev sib cais yuav tsum raug xaiv tom qab kev sib txuas cov peev nyiaj raug xam, tsis yog theej los ntawm qhov project dhau los.
| Split ratio | Hom kev poob qis (kev npaj) | Cov neeg siv khoom noj fiber ntau | Qhov twg nws haum |
|---|---|---|---|
| 1:8 | ~ 10.5 dB | 8 | Qhov thib ob theem ntawm cascade; qis- qhov ceev los yog ntev- ncav cuag tee nrog cov peev nyiaj kom txuag tau |
| 1:16 | ~ 13.8 dB | 16 | Ntev - mus txog qhov deb deb deb, tsis yog qhov ceev, yog qhov txwv |
| 1:32 | ~ 17.5 dB | 32 | Qhov chaw nyob ib puag ncig / me me - kev lag luam sib npaug ntawm kev ncav cuag, qhov ceev thiab pob nyiaj siv |
| 1:64 | ~ 21 dB | 64 | High -nruab nrab nroog tsim nrog luv feeders thiab cov ntaub ntawv pov thawj cov nyiaj tau los |
Qhov kev ntxias yog ib txwm ua rau spec qhov sib piv siab tshaj "kom nyab xeeb" ntawm cov chaw nres nkoj suav. Hauv kev xyaum, qhov sib faib loj loj yog qhov tseem ceeb ntawm FTTH tsis ruaj khov: thaum cov npoo tau nyem dhau heev lawm, kev sib txuas ntawm cov laus thiab qhov kub thiab txias viav vias noj qhov seem ntawm lub taub hau, thiab cov neeg siv ntawm qhov kawg ntawm tsob ntoo yog cov uas hu rau kev txhawb nqa thaum lub sij hawm ncov. Xaiv qhov piv txwv tom qab cov lej nyiaj txiag, tsis yog ua ntej.
Ib leeg-Stage vs Ob-Stage Spliting
Qhov sib cais tag nrho tuaj yeem ncav cuag ob txoj hauv kev, thiab kev xaiv yog kev txiav txim siab ua haujlwm, tsis yog kev xaiv khoom xwb. Hauv ibib leeg-theem (centralized)tsim, ib qho splitter - feem ntau 1:32 - zaum hauv lub txee lossis FDH thiab pub cov neeg siv khoom ncaj qha. Cov ntaub ntawv yooj yim thiab qhov poob yog tsom rau ntawm ib qhov dej- tswj qhov taw tes, yog vim li cas qhov no yog qhov nyiam nyob rau hauv cov nroog ntom ntom uas muaj kev saib xyuas yooj yim.
Hauv ibob-theem (cascaded)tsim, sib faib yog faib thoob cov nodes - piv txwv li 1:4 ntawm lub hauv paus chaw ua hauj lwm noj plaub 1:8 terminals mus txog 32 lub tsev (4 × 8), los yog 1:8 + 1:8 los ua hauj lwm 64. Cascaded splitting yog pab tau thaum cov neeg muas zaub tau kis thoob plaws lub zos, curbside terminals los yog dav sib cais cov tsev. Centralized splitting is easier to document and maintain in dense urban areas. Ob-theem tsim qauv txhim kho kev lag luam fiber ntau thiab kev sib koom ua ke, tab sis lawv ntxiv cov ntawm lub cev uas koj yuav tsum tau sau thiab sim, thiab lawv pawg splitter poob (piv txwv li, 10.5 dB + 10.5 dB ≈ 21 dB rau 64 lub tsev).

Deployment Scenarios: Aerial, Underground, Duct and Direct -Kev faus neeg
Tib qhov laj thawj ODN tuaj yeem tsim los ntawm ntau qhov sib txawv ntawm lub cev ib puag ncig, thiab txoj kev xa tawm hloov pauv cov khoom siv ntau dua li cov topology ua. Xaiv lub thawv IP ntsuas, kev tsim kho cable thiab qib kev sib khi rau qhov tseeb ib puag ncig yog dab tsi ua rau lub network tsis muaj teeb meem tom qab thawj lub caij ntuj no.
| Scenario | Hom kho vajtse | Kev pheej hmoo tseem ceeb los tswj | Xaiv xyuas |
|---|---|---|---|
| Huab cua | ADSS / tus kheej- txhawb nqa feeder, tiaj tiaj, ncej-mounted NAP, dome kaw | Cua / dej khov span load, UV raug, clearance | Span length, sag, attachment hardware, UV-stable enclosure |
| Underground (lub tes tsho / manhole) | Loose-tube armored cable, kaw inline/dome kaw, hauv qab-qib FDB | Dej ingress, dej nyab, nas puas | Siab dua IP sealing (IP67 / IP68), gel / thaiv, splice- tais slack |
| Cov kav dej / micro-duct | Round drop cable, GYTS/GYFTY hauv conduit, micro{0}}duct connectors | Rub nro, duct continuity, duct sealing | Cov kav dej loj, rub hlua, roj nplua nyeem, kawg ntsaws ruaj ruaj, dej thaiv |
| Direct -faus | Armored ncaj nraim -faus cable, faus handholes, marker daim kab xev | Crush load, av txav, khawb-ups | Qhov tob hauv faus, hom armor, txoj kev cim, kev siv hluav taws xob- qhov chaw sib koom ua ke |
Rau sab nraum zoov thiab hauv qab no - qib nodes, xaiv enclosures rated rau ib puag ncig - feem ntau IP65–IP68 nyob rau hauv UV-resistant ABS, polycarbonate los yog tuag- nrum txhuas nrog ib tug ua hauj lwm thaj tsam ntawm −40℃rau +85℃. Dej nyab- cov hnab ntim tau yooj yim xav tau qib sealing siab dua li lub thawv phab ntsa. IbSab nraum zoov splice kaw rau ODN xa tawmuas yog nyob rau hauv - ntsuas rau qhov chaw yog feem ntau ua rau qeeb, huab cua -correlated faults lub hlis tom qab xa.
ODN Bill of Materials los ntawm Txheej
Lub ODN BOM huv huv yog tsim los ntawm txheej, tsis yog los ntawm cov npe khoom tiaj tus. Muab nws los ntawm feeder, faib, poob thiab cov neeg siv khoom cia kev yuav khoom, kev teeb tsa thiab QA txhua qhov txheeb xyuas tias txhua ntu ntawm cable, passive node thiab cov kauj ruam xeem muaj qhov zoo sib xws - thiab cov fibers seem thiab cov chaw nres nkoj spare yog tiag tiag nyob rau hauv qhov kev txiav txim.

| ODN txheej | Cov khoom tseem ceeb | Hom specification | Cov ntawv txiav txim |
|---|---|---|---|
| Feeder OLT sab rau thawj qhov | Sab nraum zoov feeder cable, dome splice kaw, thawj PLC splitter | G.652D, GYXTW / GYTA / ADSS, 12–144 fibers; IP67 / IP68 kaw | Paub meej txog txoj kev ntev, suav cov fiber ntau, kaw lub peev xwm thiab seb tus thawj splitter zaum hauv lub txee lossis kaw. |
| Kev faib tawm Thawj qhov rau FDB / tsev | Distribution cable, inline kaw,fiber ntau faib lub thawv, PLC splitter rau FTTH ODN | G.652D, 6–48 fibers; FDB / NAP nrog SC / APC adapters thiab splice tais | Match chaw nres nkoj suav rau cov neeg siv khoom ceev, khaws cia cov chaw nres nkoj rau coj- tus nqi loj hlob, nce kev sib khi hauv qhov chaw raug lossis qis dua - qib. |
| Tso FDB / NAP rau thaj chaw | FTTH poob cable, clamps, nkag grommet, poob termination box | G.657A2, 1–4 fibers, tiaj tus kheej -txhawb los yog puag ncig duct hom | Pav ca poob rau luv luv aerial txoj kev, puag ncig poob rau ducts / underground. Tshawb xyuas tensile load thiab qhov tsawg kawg nkaus khoov vojvoog. |
| Subscriber Qhov chaw nkag rau ONT | SC/APC pigtail, fiber phab ntsa qhov hluav taws xob, ONT daim kab xev | OS2 / G.657A2, SC/APC, 1–3 m thaj qaum; sab hauv phab ntsa qhov hluav taws xob los yog rosette | Tiv thaiv connector endfaces kom txog thaum ua kom tiav; tshuaj xyuas thiab ntxuav ua ntej mating kom txo tau qhov ua kom yuam kev. |
| Kev txhawb nqa kuaj | VFL, OLTS, OTDR, kev soj ntsuam xyuas, cov cuab yeej tu, cov ntawv sau, cov ntaub ntawv | 1310/1550 nm test set;IEC 61300-3-35: Covkev tshuaj xyuas; OTDR taug qab ib ntu | Test iav thiab cov ntaub ntawv yog ib feem ntawm kev xa tawm BOM, tsis yog tom qab. |
Optical Link Budget: Kev xam qhov loj ntawm tag nrho ODN
Txhua qhov kev txiav txim siab saum toj no - phua piv, feeder ntev, tus naj npawb ntawm splices, connector suav - converges ntawm ib tug xov tooj: lub optical link pob nyiaj siv. GPON Class B + feem ntau yog siv los ua a~ 28 dBkev npaj siv, tab sis qhov kawg tso cai poob yuav tsum los ntawm qhov tseeb OLT/ONT chav kawm kho qhov muag thiab cov cai tswj hwm. ODN yuav tsum haum fiber ntau attenuation, splitter poob, connector khub, splices thiab ib tug cia margin nyob rau hauv uas txwv. Kev tsim qauv FTTH uas siv tau suav qhov deb tshaj plaws - tus neeg siv txoj hauv kev ua ntej, khaws cov ntaub ntawv kev nyab xeeb thiab tshem tawm cov ntsiab lus tsis tsim nyog mating ua ntej kho vajtse raug txiav txim.
| Qhov system | Cov chav kawm nyiaj txiag | Kev npaj siv | Kev txwv tseem ceeb |
|---|---|---|---|
| GPON | Chav kawm B + (~ 28 dB) / C + nyob ntawm cov khoom siv | Cov tsev nyob thiab me - lag luam FTTH | Tx hwj chim tiag tiag, Rx rhiab heev thiab cov cai margin sib txawv los ntawm cov khoom siv. |
| XGS-PON | N1 / N2 nyob ntawm cov khoom siv | 10G symmetric hloov kho lossis tsim tshiab | Lub passive ODN feem ntau rov siv tau, tab sis cov peev nyiaj thiab kev sib koom ua ke tseem xav tau kev txheeb xyuas cov cuab yeej. |
Ua haujlwm piv txwv nkaus xwb: 10 km GPON nrog 1:32 cais

| Cov khoom poob | Kev npaj xam | Piv txwv tus nqi | Hom nqi |
|---|---|---|---|
| Fiber ntau attenuation | 10 km × 0.35 dB/km | 3.5dB ua | Hom phiaj tus nqi |
| 1:32 Sib | Siv cov ntaub ntawv splitter xaiv | ~ 17.5 dB | Kev lag luam tus nqi |
| Connector khub | 4 khub × 0.4 dB | 1.6dB ib | Conservative kev npaj nqi; txheeb xyuas los ntawm OLTS |
| Fusion splices | 6 pob qij txha × 0.05 dB | 0.3dB ua | Yam nqi; txheeb xyuas los ntawm OTDR / splice cov ntaub ntawv |
| Tag nrho suav qhov poob | 22.9 dB | Piv txwv nkaus xwb | |
| Margin vs 28 dB Chav B + | 28 − 22.9 | ~ 5.1 dB | Qhov project-nyob ruaj khov |
Hauv qhov piv txwv no, qhov seem seem tsuas yog kwv yees li 5 dB ua ntej kho thiab kev hloov pauv ntawm thaj chaw raug txiav txim siab. Ib qho ntxiv splice, ib qho txuas txuas ntxiv, ib qho thib ob -theem splitter lossis ib txoj kev txuas ntxiv tuaj yeem txo cov npoo ntawd sai. Kho cov peev nyiaj raws li qhov kev txwv tsim uas teeb tsa qhov sib faib thiab qhov ntev ntawm lub feeder, tsis yog cov ntaub ntawv ua tiav tom qab xaiv BOM.
Tsim Risk Scenarios: Yuav Ua Li Cas Tsis Yog Thaum Cov Nyiaj Tau Los Hla
Cov teeb meem nyiaj txiag feem ntau tshwm sim ua ntej kev tsim kho, yog tias BOM raug tshuaj xyuas kom zoo. Cov cim ceeb toom yog qhov yooj yim: qhov sib faib siab siab, txoj hauv kev ntev, ob peb qhov txuas txuas, tsis paub meej splice suav thiab tsis muaj kev kho qhov tshwj xeeb. Nqe lus hauv qab no yog sau raws li tus qauv tsim- tshuaj xyuas qhov xwm txheej, tsis yog lub npe hu ua cov neeg siv khoom, yog li tus nyeem ntawv tuaj yeem siv daim ntawv txheeb xyuas rau txhua qhov haujlwm FTTH ua ntej xaj khoom kho vajtse.
Xav tias qhov project FTTH raug xa nrog 10–15 km ODN txoj kev, 1: 32 cais, ob peb FDB / NAP nodes thiab tsuas yog cov splitter qhov raug tso tawm - poob tus nqi hauv pob nyiaj siv. Cov qauv tsim tuaj yeem pom tau yog tias cov khoom sib txuas, cov kab sib txuas, cov khoom siv qias neeg thiab tsis suav nrog kev kho. Ua ntej lees txais tias BOM, tus kws tshaj lij yuav tsum nug plaub nqe lus nug: pes tsawg tus khub niam txiv nyob hauv txoj hauv kev tiag tiag, yuav tsum muaj pes tsawg splices tom qab kev hloov pauv, tus nqi splitter tau lees paub los ntawm daim ntawv teev cov ntaub ntawv, thiab ntau npaum li cas cov npoo tseem tshuav rau cov neeg siv khoom tom qab kho.
- Liab chij:cov peev nyiaj siv tsuas yog raug splitter poob, tsis yog xaiv splitter datasheet tus nqi.
- Liab chij:daim duab qhia cov ntsiab lus ntxiv thaj, tab sis cov lus poob suav tsuas yog ib lossis ob qhov txuas txuas.
- Liab chij:tus neeg nyob deb tshaj plaws muaj tsawg dua tus neeg teb xov tooj qhov xav tau cov paj tom qab splices thiab kho cov khoom cia.
- Kho kom raug:rov xam tag nrho txoj hauv kev nrog ntsuas lossis lav qhov tseem ceeb ua ntej kho qhov sib cais, kaw layout thiab FDB kom muaj nuj nqis.
Ib tug luam tawmtsim thiab siv txoj kev kawm ntawm Al-Gehad FTTH networkpiav qhia txog kev npaj nkag mus siv network uas npog txog 32 km² thiab 6,000 ONTs. Txoj kev tshawb no siv lub nplhaib tiv thaiv ntawm sab feeder, 20% spare feeder muaj peev xwm, thawj -theem splitting ntawm FDT, thiab lub hnub qub / tsob ntoo faib seem nrog 72F / 48F / 24F / 12F cable nqis mus rau qhov chaw FAT. Nws kuj qhia txog 243 km ntawm feeder cabling thiab 405 km ntawm kev faib kab. Cov lus qhia kev npaj muaj txiaj ntsig zoo rau OEM ODN BOMs: khaws lub feeder tiv thaiv thiab khaws cov ntaub ntawv zoo, cov kauj ruam fiber ntau suav los ntawm ntu, thiab lub peev xwm khaws cia ua ntej lub network poob.
Common ODN Design yuam kev
Thaum lub sijhawm ua haujlwm thiab kev saib xyuas, ntau qhov teeb meem ODN taug qab rov qab los rau kev tsim- tshuaj xyuas qhov khoob es tsis yog cov khoom siv tsis zoo: cov khub txuas tsis tau suav, cov ntaub ntawv tsis meej splice, tsis muaj peev xwm tsis txaus, kev xaiv tsis zoo sib khi lossis cov peev nyiaj txuas uas tsis suav rov qab tom qab kev hloov pauv. Cov teeb meem no yooj yim dua los tiv thaiv hauv BOM dua li kho tom qab cov neeg siv khoom txuas nrog.
| yuam kev | Vim li cas thiaj tseem ceeb | Kev tiv thaiv |
|---|---|---|
| Muaj ntau qhov sib cais | Stacked cascaded splitters ntxiv 3 dB ib ob zaug thiab tuaj yeem tshuab cov peev nyiaj rau qhov kawg - ntawm - tsob ntoo subscribers. | Siv qhov sib cais yam tsawg kawg nkaus uas ua tau raws li qhov ceev; khaws cascade poob hauv cov nyiaj txiag suav. |
| Ntau dhau splice/mating cov ntsiab lus | Txhua qhov txuas txuas thiab splice ntxiv qhov poob qis thiab qhov tshwm sim ntawm kev cuam tshuam uas cuam tshuam OTDR kab. | Txo cov ntsiab lus tsis tsim nyog mating; haum Hoobkas-tawm, kuaj cov rooj sib txoos. |
| Tsis muaj cov chaw nres nkoj tshwj xeeb lossis cov fibers seem | Siv - tus nqi loj hlob ua rau tag nrho cov node rebuild es tsis txhob ntawm ib thaj chaw yooj yim. | Loj FDB/NAP chaw nres nkoj suav thiab feeder fiber ntau suav saum hnub-ib qho kev thov. |
| Tsis muaj qhov txuas - xam nyiaj txiag | Cov neeg thov nkag siab tshaj plaws tuaj yeem poob qis dua tus neeg tau txais txiaj ntsig, raws li tau piav qhia hauv qhov xwm txheej txaus ntshai saum toj no. | xam fiber ntau + splitter + connector + splice poob nrog 3-5 dB npoo ua ntej xaj. |
| Tsis ncaj ncees lawm fiber ntawm nruj tee | Standard G.652D raug khoov poob ntawm phab ntsa nkag thiab rosettes. | Siv G.657A2 khoov-insensitive poob cable ntawm lub sijhawm kawg. |
FAQ
Q: Dab tsi yog ODN sawv rau hauv fiber ntau optics?
A: ODN sawv rau Optical Distribution Network. Nyob rau hauv FTTH, nws txhais tau hais tias txoj kev passive fiber ntau ntawm OLT thiab ONT: feeder cable, splitters, kaw, tis thawv, xa cable thiab subscriber - sab txiav.
Q: Dab tsi yog ODN fiber optic tov rau FTTH?
A: Nws yog ib qho ua tiav passive access tsim, tsis yog ib yam khoom. Ib qho kev daws teeb meem ODN txhais tau hais tias lub feeder, faib thiab tso cov khaubncaws sab nraud povtseg, tom qab ntawd sib tw cable hom, splitter ratio, FDB / NAP peev xwm, connector hom thiab kev xeem yuav tsum tau rau txoj kev thiab txuas nyiaj txiag.
Q: Yuav ua li cas feeder, faib thiab poob ntu faib ua haujlwm hauv ODN?
A: Lub feeder nqa ntau dua - suav cable los ntawm CO lossis OLT cheeb tsam mus rau thawj qhov chaw. Cov ntu kev faib tawm faib cov fibers mus rau pawg neeg koom nrog los ntawm FDB / NAP thawv. Cov ntu ntu yog luv, khoov -sensitive khiav los ntawm lub thawv nkag mus rau qhov chaw.
Q: Yuav ua li cas cais qhov sib piv cuam tshuam rau kev pab them nqi thiab cov peev nyiaj kho qhov muag?
A: Qhov sib faib ntau dua ua rau cov neeg siv khoom ntau dua rau PON chaw nres nkoj tab sis siv nyiaj siv kho qhov muag ntau dua. Raws li daim ntawv qhia kev npaj, 1: 32 feem ntau yog siv rau kev tsim vaj tsev nyob sib npaug, thaum 1: 64 xav tau txoj kev luv luv lossis cov peev nyiaj muaj zog dua. Nco ntsoov xyuas cov ntaub ntawv cais cov ntawv xaiv thiab OLT / ONT chav kawm.
Q: Yam khoom twg muaj nyob hauv FTTH ODN BOM?
A: Ib qho BOM tiav ib txwm muaj xws li feeder cable, splice kaw, PLC splitters, tis cable, FDB / NAP thawv, G.657A2 nco cable, txiav lub thawv, adapters, pigtails, thaj qaum, daim ntawv lo thiab kuaj / ntxuav kev them nyiaj yug.
Q: Dab tsi yog qhov feem ntau ODN tsim yuam kev?
A: Cov kev ua yuam kev feem ntau yog undercounting connector khub, ntxiv ntau sib cais los yog splice cov ntsiab lus, tsis muaj seem fibers los yog cov chaw nres nkoj, siv qhov tsis ncaj ncees lawm enclosure ntsuam xyuas rau ib puag ncig, thiab kho qhov sib cais ua ntej recalculating qhov link pob nyiaj siv.
Q: Ib zaug -theem lossis ob-theem faib rau ODN?
A: Ib qho -theem splitting yog yooj yim dua rau sau thiab khaws cia nyob rau hauv qhov chaw ntom ntom. Ob -theem splitting tuaj yeem txuag cov khoom noj fiber ntau hauv cov kev sib cais, tab sis nws ntxiv cov nodes thiab cov ntsiab lus xeem. Qhov kev xaiv zoo dua yog nyob ntawm pob nyiaj siv nyiaj, cov neeg siv khoom ceev thiab kev saib xyuas kev nkag.
Q: Tib ODN puas tuaj yeem txhawb GPON thiab XGS-PON?
A: Feem ntau yog, vim hais tias cov passive fiber ntau thiab PLC splitters tuaj yeem nqa cov wavelengths cuam tshuam. Qhov kev hloov kho tseem yuav tsum tau muaj pov thawj ntawm XGS-PON cov chav kawm siv nyiaj, kev npaj sib koom ua ke, ONT/OLT optics thiab cov npoo seem ntawm cov neeg siv khoom nyob deb tshaj plaws.
Q: Cov ntaub ntawv dab tsi xav tau rau FTTH ODN BOM hais lus?
A: Xa cov kev ncua deb, cov neeg suav suav, sib faib piv, pub thiab faib cov fiber ntau suav, ib puag ncig, kaw lossis lub thawv qhov chaw, xav tau IP ntsuas, hom txuas, cable tsim, xeem cov cai thiab OEM ntim lossis daim ntawv lo.
Q: Yam ODN twg tuaj yeem hloov kho rau cov haujlwm OEM?
A: Cov khoom siv kho kom haum muaj xws li cable ntev thiab fiber ntau suav, splitter piv thiab pob style, FDB / NAP chaw nres nkoj suav, kaw lub tais ntim, adapter layout, poob-kab siv, cov ntawv lo, thawv ntawv thiab cov khoom siv pawg.
Q: Kuv yuav xaiv tus tsim nyog ODN cov khoom lag luam li cas?
A: Tshawb xyuas seb tus neeg muag khoom puas tuaj yeem tshuaj xyuas tag nrho cov saw hlau passive, tsis yog tsuas yog hais cais SKUs. Rau ODN cov haujlwm, kev txhawb nqa muaj txiaj ntsig suav nrog kev kuaj xyuas BOM, cov ntaub ntawv, cov duab kos, cov ntaub ntawv sib cais, kev sib txuas tshuaj xyuas kev txhawb nqa, sau npe thiab kev tswj cov ntim khoom.
Xaiv tus tsim nyog ODN Cov Khoom Muag Khoom
Tom qab topology thiab kho qhov muag pob nyiaj tau kho, kev xaiv tus neeg muag khoom tau dhau los ua ib feem ntawm kev txiav txim siab engineering. Ib tus tsim nyog ODN tus neeg muag khoom yuav tsum tsis txhob tso cov cables, thawv thiab cais cais; nws yuav tsum pab xyuas seb cov khoom puas tuaj yeem tsim khoom, sau npe, ntim thiab sim ua ib daim nqi ntawm cov khoom siv FTTH.
| Muaj peev xwm tsim khoom | Yuav ua li cas kom paub tseeb | Vim li cas nws tseem ceeb rau FTTH ODN tej yaam num |
|---|---|---|
| Cov khoom sib txuam | Splitter pob, FDB chaw nres nkoj suav, kaw lub tais ntim, hom adapter thiab poob -kev tsim kho cable | Tiv thaiv BOM uas zoo nkaus li ua tiav tab sis tsis tuaj yeem ntsia tau raws li daim ntawv qhia chaw nres nkoj. |
| Factory xeem kev them nyiaj yug | Splitter insertion-cov ntaub ntawv poob, kev tshuaj xyuas cov khoom sib txuas, cov qauv kuaj xyuas thiab kuaj ntim | Txo cov kev ua haujlwm ua haujlwm tsis raug thiab muab cov ntaub ntawv cog lus los sib piv nrog OLTS / OTDR cov txiaj ntsig. |
| OEM cov ntaub ntawv | Daim duab kos duab, daim ntawv teev npe, daim ntawv kos duab kos duab, kos duab thawv thiab daim ntawv teev cov khoom siv | Pab cov neeg xa khoom thiab cov neeg cog lus xa cov khoom siv rov ua dua tshiab rau cov tsev, cov txee lossis cov neeg koom nrog pawg. |
| Ib puag ncig haum | Kev ntsuam xyuas IP, UV tsis kam, txoj kev sib khi, cov hlua khi, kev ntsuas tensile thiab khoov - qhov yuav tsum tau muaj | Ua kom lub dav hlau, kav dej, qhov tuav thiab ncaj nraim - cov pob txha faus siv cov khoom siv zoo es tsis txhob siv ib lub thawv generic. |
Rau ib txoj haujlwm ODN kev cai, nug tus neeg muag khoom kom paub meej tias BOM tiv thaiv txoj kev deb, sib faib piv, suav cov neeg siv, ib puag ncig kev teeb tsa thiab kev sim ua ntej tsim khoom. Qhov no yog qhov tseem ceeb tshwj xeeb tshaj yog thaum qhov kev txiav txim sib xyaw ua ke ntau yam passive Cheebtsam - piv txwv li PLC splitters, FDBs, splice kaw, pigtails, poob cable thiab cov ntawv lo - rau hauv ib qho khoom siv OEM.
Pom zoo ODN Cheebtsam los ntawm Txheej
Cov kab lus saum toj no piav qhia txog cov txheej txheem engineering. Cov khoom xaiv hauv qab no yog pab pawg los ntawm ODN txheej yog li pawg neeg yuav khoom tuaj yeem hloov cov qauv tsim rau hauv RFQ lossis BOM yam tsis tau hloov cov lus qhia rau hauv cov khoom catalogue. Rau txhua yam khoom, paub meej tias qhov chaw ib puag ncig, muaj peev xwm, hom txuas thiab qhov yuav tsum tau ua ua ntej pom zoo rau tus qauv kawg.
Sab nraum zoov Cable + Splice Kaw
Siv sab nraum zoov feeder cable thiab kaw splice kaw rau qaum ODN txoj kev. Paub meej tias fiber ntau suav, tensile ntsuam xyuas, kaw lub tais muaj peev xwm, suav cable nkag thiab IP ntsuas ua ntej yuav khoom.
Saib splice kawFDB / NAP Box + PLC Splitter
Siv cov thawv ntim fiber ntau thiab PLC splitters los tswj cov neeg siv khoom. Paub meej qhov sib piv, hom adapter, suav chaw nres nkoj, pob splitter thiab lub peev xwm seem.
Saib PLC splittersG.657A2 Drop Cable + Termination Box
Xaiv txoj kab ncaj nraim los yog puag ncig xaim raws li dav hlau, kav dej lossis phab ntsa- nkag mus. Ua ke nws nrog lub thawv txiav tawm uas txhawb nqa txoj kev yooj yim thiab khoov tswj.
Saib FTTH poob cablePigtail + Phab ntsa qhov hluav taws xob + Patch Cord
Siv SC/APC pigtails, sab hauv phab ntsa qhov hluav taws xob thiab luv patch cords kom tiav ONT- sab kev sib txuas. Khaws cov interfaces capped kom txog thaum kuaj xyuas thiab ua kom tiav.
Saib phab ntsa qhov hluav taws xobCov Qauv & Cov Lus Qhia
Cov ntaub ntawv hauv qab no pab cov engineers txheeb xyuas cov txiaj ntsig siv hauv ODN tsim, kev siv nyiaj txiag thiab kev yuav khoom. Nco ntsoov xyuas tsab ntawv tam sim no thiab tus neeg teb xov tooj cov cai lees txais hauv zos ua ntej kev pom zoo zaum kawg.
| Kev siv | Vim li cas nws tseem ceeb hauv kev daws ODN |
|---|---|
| ITU-T G.652 | Standard ib leeg - hom fiber ntau siv nyob rau hauv feeder thiab faib kev npaj. |
| ITU-T G.657 | Khoov-sensitive ib leeg- hom fiber ntau pawg rau kev nkag mus thiab tso txoj hauv kev. |
| ITU-T G.984.1 | GPON cov yam ntxwv dav dav thiab cov chav kawm nyiaj txiag rau kev siv kho qhov muag. |
| ITU-T G.9807.1 | XGS-PON system siv rau 10-Gigabit symmetric PON hloov khoom dua tshiab. |
| ITU-T G.671 | Optical Cheebtsam yam ntxwv cuam tshuam rau PLC splitters. |
| IEC 60529 / IP kev ntsuas | Ingress tiv thaiv kev faib tawm rau kev kaw, FDBs thiab enclosures. |
| IEC 61300-3-35: Cov | Connector endface soj ntsuam thiab pass/fail qauv; siv cov ntawv tam sim no. |
| TIA-526 /IEC 61280-4-1: Cov | Txhim kho fiber ntau attenuation thiab kho qhov muag - cov txheej txheem ntsuas poob. |
Hais txog Glory Optical:Ningbo Glory Optical Communication Co., Ltd. muab FTTH / FTTx passive optical Cheebtsam nrog rau fiber ntau termination boxes, splice kaw, PLC splitters, pigtails, patch cords, nco cables thiab ODN accessories, nrog OEM thiab ODM kev them nyiaj yug rau distributors, neeg cog lus thiab project-raws li pab neeg yuav khoom. Rau cov khoom siv ODN kev cai, Glory Optical tuaj yeem pab txhawb kev sib koom ua ke, daim ntawv lo / ntim khoom customization thiab ua ntej - cov ntaub ntawv xa tuaj raws li kev pom zoo RFQ. Cov khoom muaj nqis hauv kab lus no yuav tsum tau lees paub tawm tsam cov ntaub ntawv tshiab lossis qhov project- tshwj xeeb RFQ.
Daim ntawv ceeb toom:Phau ntawv qhia no yog rau kev npaj thiab kev txhawb nqa khoom. Nws tsis hloov cov lis dej num hauv zos, tus neeg teb xov tooj tus qauv, kev tshuaj xyuas kev tsim qauv, cov khoom siv - cov lus qhia tshwj xeeb rau kev teeb tsa lossis kev lees paub los ntawm tus tswv network.