Rau pem teb-rau-hauv pem teb hloov txuas ntawm li 15 m, qhov hloov module txiav txim siab hom fiber ntau thiab qhov deb tsis tshua muaj teeb meem. Multimode SR optics ntawm OM4 thiab ib hom LR lossis BiDi optics ntawm OS2 ob leeg mus txog deb tshaj 15 m. Nyeem cov module ib feem ntawm ob qho kawg, xaiv cov fiber ntau uas module tau teev tseg rau, tom qab ntawd paub meej tias cov tub ntxhais suav, siv cable, ntsuas hluav taws thiab patching ua ntej koj sib piv cov lus.
Cov ntsiab lus tseem ceeb rau kev txiav txim siab no
- 10GBASE-SRtxhawb nqa txog 300 m ntawm OM3 thiab 400 m ntawm OM4;10GBASE-LRtxhawb 10 km ntawm ib hom fiber ntau (Cisco SFP + cov ntaub ntawv ntawv).
- 15 m ntawm OM4 ntawm 3.0 dB / km ntxiv txog 0.05 dB. Ntawm no ntev,kev txuas suav thiab connector poobtsim cov nyiaj poob haujlwm.
- Ib qhov txuas duplex siv2 fibers; ib leeg-fiber BiDi khub siv1. Spare fibers hauv tib lub tsho sib koom ib txoj hauv kev.
- Ib yam khoom uas sau tias "patch cable" xav tau nws cov ntaub ntawv txheeb xyuashluav taws kub ntsuas, armor, rub nro thiab khoov vojvoogua ntej nws mus rau hauv ib lub riser lossis conduit.
Ib qho 15 m hauv pem teb-rau-pem teb txuas: qhov xwm txheej thiab cov lus nug qhib
Cov lus qhia no ua raws li qhov project piav qhia, thiab nws tsis yog qhov khoom siv Glory. Ob lub keyboards zaum ntawm cov plag tsev sib txawv, txoj kev npaj yog li 15 m, thiab lub hom phiaj yog ntau dhau ntawm lawv. Ib tus neeg muag khoom tau hais txog plaub-fiber, micro-armored, OM4, kev sib dhos ua ntej ntawm kwv yees li US $ 400, thiab tus installer tab tom txiav txim siab LC keystone couplers rau patching. Tus neeg muag khoom txuas tus nqi tsis ntev los no nce rau cov ntaub ntawv chaw xav tau. Cov lus piav qhia ntawd los ntawm tus neeg muag khoom, thiab phau ntawv qhia no tsis kho nws raws li cov ntaub ntawv lag luam.
Daim duab 1. Txoj hauv kev hauv qhov piv txwv: ob lub qhov hloov pauv, ob qhov kev xaiv LC patching cov ntsiab lus thiab ib qho hauv pem teb nkag. Txhua qhov kev sib txuas ntxiv yuav siv ib feem ntawm cov peev nyiaj poob.
Lub rooj txheeb seb qhov project muab dab tsi los ntawm qhov tseem yuav tsum tau sau. Txhua yam nyob rau hauv nruab nrab kem yog ib lo lus nug rau tus neeg muag khoom lossis qhov chaw soj ntsuam.
| Yam khoom | xwm txheej | Phau ntawv no siv nws li cas |
|---|---|---|
| Txoj kev ntawm li 15 m ntawm cov plag tsev | Hais, tseem tsis tau ntsuas | Rov ntsuas raws txoj kev tiag tiag thiab ntxiv slack ntawm ob qho kawg |
| Lub hom phiaj ntawm kev hloov pauv-rau-hloov dhau los | Hais | Xav tau lub hom phiaj ceev thiab cov module ib feem zauv |
| 4-fiber, micro-armored, OM4, pre-terminated cable ntawm txog US $ 400 | Quote tau txais | Kev xaiv xaiv; tus nqi piv tsuas yog tom qab specs match |
| LC keystone patching | Lub tswv yim tab tom tshuaj xyuas | Txheeb xyuas qhov poob, hom fiber ntau thiab kev tiv thaiv rov qab kawg |
| Hloov cov qauv thiab nruab modules | Tsis paub | Thawj yam khoom los sau |
| Cov ntaub ntawv cable tag nrho, lub tsho kos npe, cov xwm txheej ntawm txoj kev | Tsis paub | Yuav tsum tau ua ntej taag installation |
| Tus nqi nce los ntawm cov ntaub ntawv chaw xav tau | Cov lus qhia ntawm tus muag khoom | Tsis siv los ua pov thawj |
Pib nrog lub hom phiaj ceev thiab cov module hauv txhua qhov hloov
Lub transceiver yog tsim rau ib hom fiber ntau thiab ib lub qhov rais wavelength. Cisco cov ntawv luam tawm SFP + cov ntaub ntawv qhia tau hais tias tib yam 10 Gigabit Ethernet ceev daim ntawv qhia txog kev xaiv cable sib txawv nyob ntawm tus qauv.
| Module (Cisco piv txwv) | Lub wavelength | Fiber nws yog teev rau | Fibers rau qhov txuas | Kev ncav cuag |
|---|---|---|---|---|
| 10GBASE-SR (SFP-10G-SR) | 850 nm | Multimode: OM3 txog 300 m, OM4 txog 400 m | 2 (dual LC) | 400m ua 4 |
| 10GBASE-LR (SFP-10G-LR) | 1310 nm | Tib hom (G.652) | 2 (dual LC) | 10 km |
| 10GBASE-BX10 BiDi (SFP-10G-BXD-I / BXU-I) | 1330nm thiab 1270nm | Ib hom, ib txoj hlua | 1 | 10 km |
Peb cov ntsiab lus los ntawm tib daim ntawv teev cov ntaub ntawv cuam tshuam rau qhov txuas luv luv. Qhov tsawg kawg nkaus cabling nrug rau -SR thiab -LR modules yog 2 m, yog li 15 m zaum nyob rau hauv qhov ntau. Cov khoom sib txuas uas tau teev tseg yog dual LC / PC, thiab Cisco hais tias tsuas yog PC lossis UPC thaj qaum tau txais kev txhawb nqa, yog li kev sib dhos ua ntej rau cov qauv no yuav tsum nqa LC / UPC xaus. Ib khub BiDi xav tau ob qhov sib txawv, ib qho ntawm txhua qhov kawg, txuas los ntawm ib txoj hlua.
Kev nrawm nrawm nrawm dua qhov poob nyiaj. Fluke Networks hais txog 1.5 dB qhov siab tshaj plaws channel tso qhov poob rau 40GBASE-SR4 dhau OM4, uas ua rau cov xov tooj sib txuas hauv txoj hauv kev tsim cov lus nug. Adata center fiber ntau cable design guidenpog 400G thiab 800G rooj plaub rau chav tshiab.
OM4 vs OS2: yuav ua li cas xaiv rau qhov txuas no
OM 4yog laser-optimized 50/125 µm multimode fiber ntau siv nrog 850 nm optics xws li 10GBASE-SR.OS 2yog 9/125 µm ib hom fiber ntau siv nrog 1310 nm thiab 1550 nm optics xws li 10GBASE-LR. Ntawm 15 m, ob lub fibers nqa lub teeb liab nrog cov npoo loj, yog li qhov kev txiav txim siab so ntawm cov khoom siv thiab cov phiaj xwm.
- Ob lub keyboards twb tuav SR modules thiab qhov ceev yuav nyob twj ywm rau lub neej ntawm cable.Xaiv OM4. Lub cable sib phim cov modules hauv tes thiab SR ncav cuag lub taub hau dav.
- Cov modules yuav raug hloov lawm, lossis tom qab txav mus rau qhov nrawm dua yog qhov yuav.Nqe OS2 ua ke nrog LR lossis BiDi modules rau ob qho kawg. Tag nrho cov nqi ntawm cov ntaub ntawv, suav nrog transceivers, yog qhov sib piv uas suav.
- Txoj kev npaj tseem qhib.Nug cov neeg muag khoom rau kev tsim kho hybrid uas nqa ob qho tib si OM4 thiab OS2 fibers. Lub koom haum Fiber Optic sau tseg tias ntau tus neeg siv ntxiv ib hom fiber ntau rau ntau hom kab hluav taws xob vim tias cov fibers ntxiv raug nqi me ntsis piv nrog rub lub cable thib ob.
- OM3 kuj yog ib qho kev xaiv.Ntawm 15 m, OM3 ntsib 10GBASE-SR ncav cuag hauv Cisco lub rooj. OM4 khwv tau nws tus nqi them rau kev ua haujlwm ntev dua thiab ntawm cov nyiaj siv ceev nrawm dua.
Plaub fibers los yog rau: suav los ntawm lub module ua ntej
Txhua qhov sib txuas Ethernet siv ob fibers, thiab txhua qhov txuas BiDi siv ib qho. Suav cov fibers uas xaiv optics xav tau hnub no, ces txiav txim siab seb qhov seem yog rau.
| Kab | Dab tsi nws tuaj yeem nqa tau | Yuav ua li cas kom paub meej |
|---|---|---|
| 4 fibers | Ib tug duplex txuas ntxiv rau ib khub spare, los yog ob tug duplex txuas uas tsis muaj spare | Seb puas yog qhov txuas txuas thib ob (piv txwv li ib pawg sib txuas sib txuas) tau npaj |
| 6 fibers | Ib tug duplex txuas ntxiv rau ob qho khoom seem, lossis mus txog peb qhov txuas duplex | Sab nraud txoj kab uas hla, khoov vojvoog thiab txuas lub taub hau loj, uas tuaj yeem loj hlob nrog fiber ntau suav |
| Hybrid (piv txwv li OM4 khub ntxiv rau OS2 khub) | Ib qhov txuas multimode thiab ib hom kev sib txuas hauv ib lub tsho | Xim coding thiab daim ntawv lo kom txhua khub mus txog qhov zoo module |
Spare fibers npog kev puas tsuaj thaum lub sij hawm txiav thiab tom qab hloov. Lub koom haum Fiber Optic pom zoo kom ntxiv cov khoom seem thaum tsim, vim tias fibers raug nqi me ntsis tom ntej no rau kev txhim kho lwm lub cable. Ib nkawm khub mus rau tib lub tsho tib txoj kev raws li tus khub ua haujlwm. Yog tias qhov yuav tsum tau muaj kev tiv thaiv kev txiav los yog hluav taws kub hauv riser, nws hu rau txoj kev thib ob nrog nws tus kheej kos duab, thiab cov fibers ntxiv hauv ib lub cable tsis tuaj yeem muab nws.
Lub "patch cable" puas tuaj yeem mus nruab nrab ntawm cov plag tsev? Yuav ua li cas los xyuas ua ntej taag installation
"Patch cable" npe cov khoom lag luam: kev sib dhos ntawm lub Hoobkas. Nws hais me ntsis txog seb qhov kev sib dhos yog tsim los rau lub riser, cov kav dej los yog hauv pem teb nkag. Lub koom haum Fiber Optic hais tias txhua lub xov tooj hluav taws xob tau teeb tsa hauv tsev yuav tsum ua kom tau raws li cov lej hluav taws kub, uas tsis muaj cov cim cable yuav tsum tsis txhob muab tso rau hauv tsev, thiab cov kab hluav taws xob sab nraum zoov tsis muaj qhov ntsuas hluav taws yog txwv rau qhov ntev hauv tsev (50 feet hauv nws cov lus qhia hauv Teb Chaws Asmeskas). Cov tshev hauv qab no tig cov ntsiab lus rau hauv cov lus nug rau daim ntawv teev cov ntaub ntawv.
| Tshawb xyuas | Vim li cas thiaj tseem ceeb | Nrhiav qhov twg |
|---|---|---|
| Jacket fire marking | US thaj chaw cable nqa OFN, OFNR (riser) lossis OFNP (plenum) style ratings raws li NEC Tshooj 770; lwm thaj chaw siv lawv cov chav kawm | Sau rau ntawm lub tsho thiab teev nyob rau hauv cov ntaub ntawv |
| Armor hom | Hlau armor yog conductive thiab yuav tsum tau grounded thiab bonded; non-metallic armor ua raws cov cai sib txawv | Kev tsim kho kab kos duab |
| Rub nro thiab cov tswv cuab muaj zog | Rub ntawm cov tswv cuab lub zog, tsis txhob ntawm cov fiber ntau lossis txuas; patch-cord-chav kawm cable muaj qhov nruj nruj dua li riser cable | Daim ntawv thov: installation nro (N) |
| Khoov vojvoog thaum rub thiab so | Txoj cai ib txwm: 20 zaug cable txoj kab uas hla nyob rau hauv nro, 10 zaug ib zaug ntsia. Ib tug 3 hli qaum muab 60 hli thiab 30 hli | Cov ntaub ntawv tseem ceeb tshaj txoj cai |
| Connector taub hau thiab khau raj loj | Qhov xaus ua ntej yuav tsum dhau los ntawm lub tes tsho, qhov lossis cov kav dej tsis raug yuam | Dimensioned duab los ntawm tus neeg muag khoom |
| Pem teb nkag | Kev teeb tsa sab hauv tsev yuav tsum tau tua hluav taws qhov twg cable hla hauv pem teb | Local code thiab cov ntsiab lus ntawm lub tsev firestop |
| Kev taw qhia kev teeb tsa | Vertical khiav yog qhov zoo tshaj plaws poob nrog hangers thiab kev pabcuam loops es tsis rub | Installer method nqe lus |
Lub hwjchim ci ntsa iab tus kheej khoov-txhim kho cov lus qhia hauv tsev LC / SC thaj qaum kev teeb tsa ntawm 60–150 N, piv nrog rau 1,200 N rau sab hauv tsev riser cable, thiab qhia cov neeg tsim khoom kom rub cov tswv cuab ntawm lub zog aramid es tsis yog lub tsho. Siv tib lub logic rau ib qho kev sib dhos ua ntej: tau txais nws qhov kev ntsuas nruj thiab siv lub tes tsho rub lossis rub lub qhov muag yog tias tus neeg muag khoom muab ib qho. Ntau cov duab nyob hauvYuav ua li cas hloov tau Fiber Optic Cable? Khoov Limits, Tolerances & Cov lej tiag.
LC keystone patching thiab tiv thaiv lub nraub qaum-kawg fiber ntau
Ib qho LC duplex keystone coupler snaps rau hauv lub ntsej muag lossis keystone vaj huam sib luag thiab koom nrog ob lub LC txuas. Ib qho piv txwv luam tawm, Eaton's N455-000-WH-KJ, yog multimode LC duplex coupler rau 50/125 lossis 62.5/125 fiber ntau, thiab nws cov npe lees txais ob qho kev sib txuas yooj yim lossis ib qho khoom sib txuas. Ib hom kev txuas ib leeg xav tau ib qho kev sib txuas uas tau teev tseg rau ib hom fiber ntau, yog li xyuas cov hom fiber ntau ntawm cov npe.
Txhua lub coupler ntxiv ib qho kev sib txuas
Fluke Networks piav qhia tias TIA qhov siab tshaj plaws ntawm 0.75 dB rau ib qhov txuas yog qhov tsis zoo tshaj plaws, thaum cov qauv sib txuas tsis zoo poob ib ncig ntawm 0.3 txog 0.5 dB thiab qhov poob qis ntawm 0.15 txog 0.2 dB. Ntawm no yog cov piv txwv lej rau 15 m txuas tiv thaiv 1.5 dB nyiaj:
| Poob feem | Kev suav | Kev tshwm sim |
|---|---|---|
| 15m4 ua | 0.015 km × 3.0 dB/km | txog 0.05dB |
| Ob qhov sib txuas ntawm 0.3 dB txhua (tus qauv) | 2 × 0.3 dB | 0.6 dB |
| Tag nrho nrog cov nqi raug | 0.65 dB, tawm ntawm 0.85 dB | |
| Ob qhov sib txuas ntawm 0.75 dB qhov phem tshaj plaws | 2 × 0.75 dB ntxiv rau 0.05 dB | 1.55 dB, siab dua 1.5 dB |
Qhov nyiaj pub dawb 1.5 dB hauv qhov piv txwv no siv rau 40GBASE-SR4-chav kawm txuas, thiab 10 Gigabit duplex txuas ua raws li lawv tus kheej cov peev txheej. Lub hauv paus ntsiab lus yog: ntawm 15 m cov fiber ntau pab yuav luag tsis muaj dab tsi thiab kev sib txuas siv nyiaj txiag. Nug tus neeg muag khoom rau qhov ntsuas qhov poob ntawm qhov sib txuas thiab cov khoom sib txuas, thiab khaws tus lej ntawm cov khub sib raug zoo kom tsawg kawg ntawm qhov kev npaj kho mob xav tau.
Tiv thaiv qhov chaw uas cov fibers sib cais
Yog tias cov kiv cua sib dhos tawm mus rau hauv ib tus neeg fibers tom qab phab ntsa phaj, qhov kev hloov pauv yuav tsum muaj kev txhawb nqa, tiv thaiv qhov chaw. Lub koom haum Fiber Optic sau tseg tias kev faib-style cable muaj fibers uas tsis yog ib tus zuj zus ntxiv, yog li nws yuav tsum raug txiav tawm hauv lub vaj huam sib luag lossis lub thawv sib txuas. Siv lub thawv fiber ntau txiav los yog khib-sabfiber optic thaj vaj huam sib luaglos tuav lub breakout, slack thiab khoov vojvoog. Glory lubfiber optic termination boxrange yog ib qhov chaw los nrhiav qhov chaw kaw. Ib tug liab qab keystone faceplate tawm ntawm ob txhais ceg uas tsis muaj strain nyem.
Sib piv cov kab lus los ntawm kab
Ib qho US $ 400 quotes yuav piv tau tsuas yog thaum tib yam khoom muaj nyob rau hauv txhua qhov kev thov. Siv cov npe hauv qab no ua tus qauv thov.
| Kab khoom | Qhia |
|---|---|
| Fiber ntau | Hom thiab qib (OM4 lossis OS2, ntxiv rau txhua qhov kev teeb tsa hybrid), suav fiber ntau thiab xim lossis daim ntawv qhia |
| Cov khoom sib txuas | LC, polish (UPC tshwj tsis yog lub module hu rau lwm tus), duplex clip thiab polarity |
| Ntev | Ntsuas txoj kev ntxiv slack ntawm txhua qhov kawg, thiab qhov chaw muab khoom ntsuas los ntawm |
| Kev tsim kho kab | Jacket thiab hluav taws ntsuam xyuas, cov khoom siv armor, sab nraud txoj kab uas hla, rub kev muab |
| Test pov thawj | Insertion poob tshwm sim rau txhua fiber ntau, nrog rau daim ntawv qhia khi rau lub rooj sib txoos |
| Cov khoom siv | Couplers, faceplates, txiav lub thawv los yog vaj huam sib luag, thaj cords, daim ntawv lo |
| Kev pabcuam | Installation, firestopping, kuaj, warranty thiab lub sij hawm xa tuaj |
Tshawb xyuas, sim thiab sau cov ntawv txuas txuas
Fluke Networks qhia tias tib txoj hauv kev kom paub meej tias cov channel ua tau raws li qhov yuav tsum tau ua kom tsis muaj qhov tso tawm yog Tier 1 kev sim nrog qhov ntsuas qhov muag pom tom qab kev teeb tsa. Tshawb xyuas thiab ntxuav txhua qhov txuas kawg ua ntej mating, sim txhua qhov fiber ntau, thiab khaws cov txiaj ntsig nrog txoj kev kos duab. Rov kuaj dua yog tias kev tsim kho ua haujlwm tshwm sim nyob ze ntawm txoj kev tom qab, vim tias kev tsoo thiab microbend puas tuaj yeem tshwm sim ntau lub lis piam tom qab qhov xwm txheej.
Daim ntawv pov thawj kev muag khoom
- Tam sim no thiab lub hom phiaj ceev, ntxiv rau tus lej ntawm txhua qhov hloov thiab module.
- Ntsuas txoj kev ntev, slack ntawm txhua qhov kawg thiab qhov chaw rau lub taub hau txuas ua ntej kom dhau.
- Fiber hom, suav fiber ntau, connector hom thiab polish, thiab polarity.
- Kev tsim kho cable, lub tsho hluav taws kub ntsuas thiab cov chaw tsim khoom qhov kev teeb tsa.
- Patching interface, strain nyem, tiv thaiv txhua qhov fiber ntau breakout thiab slack cia.
- Qhov kev tsocai muaj xws li, daim ntawv tshaj tawm kev xeem muab thiab txoj kev lees txais.
Cov lus nug uas nquag nug
Q: Puas yog OM4 lossis OS2 zoo dua rau 15 m txuas?
A: Ob leeg ncav cuag deb tshaj li 15 m, yog li qhov kev xaiv zoo dua yog qhov uas phim koj cov qauv hloov pauv thiab hloov kho txoj kev npaj. OM4 haum rau SR modules uas twb muaj lawm, thiab OS2 suits LR lossis BiDi modules thiab hloov mus sij hawm ntev. Sib piv tag nrho cov nqi ntawm cov ntaub ntawv xws li transceivers.
Q: Kuv puas tuaj yeem siv OS2 cable nrog multimode SR module?
A: Siv hom fiber ntau qhov module tau teev tseg rau. Cisco cov ntaub ntawv teev cov 10GBASE-SR module rau multimode fiber ntau thiab 10GBASE-LR module rau ib hom fiber ntau. Paub meej tus naj npawb ua ntej xaj lub cable.
Q: Ntev npaum li cas OM4 tuaj yeem nqa 10 Gigabit Ethernet?
A: Cisco cov ntaub ntawv qhia txog 400 m rau 10GBASE-SR ntawm OM4 thiab mus txog 300 m ntawm OM3.
Q: Kuv puas xav tau 6 fibers tsis yog plaub?
A: suav cov fibers koj optics xav tau tam sim no. Plaub fibers tuav ib tug duplex txuas thiab ib tug spare khub; rau tuav ib qho txuas thiab ob qho khoom seem. Xaiv rau yog tias koj xav tau qhov txuas thib ob lossis xav tau qhov tshwj xeeb loj dua, thiab xyuas qhov loj dua sab nraud tawm tsam koj txoj hauv kev.
Q: Puas yog cov fibers seem muab kuv rov ua dua?
A: Lawv tiv thaiv cov fiber ntau puas hauv lub cable. Kev txiav lossis hluav taws nyob rau hauv txoj kev cuam tshuam rau txhua qhov fiber ntau hauv lub tsho, yog li txoj kev redundancy xav tau ib txoj kab thib ob ntawm txoj kev sib cais.
Q: Puas tuaj yeem tsim micro-armored thaj cable rau hauv lub riser ntawm cov plag tsev?
A: Qhov ntawd nyob ntawm nws lub tsho kos npe, kev ntsuas hluav taws thiab kev teeb tsa tshwj xeeb. Tshawb xyuas cov ntawv luam tawm thiab daim ntawv teev cov ntaub ntawv rau riser lossis plenum haum, hom armor thiab rub nro, thiab ua raws li cov cai hauv zos thiab cov kev cai tua hluav taws.
Q: Puas yog LC keystone coupler ntxiv poob?
A: Yog. Txhua lub coupler tsim ib qho kev sib txuas. Siv tus neeg muag khoom qhov ntsuas qhov poob hauv koj cov peev nyiaj thiab khaws cov xov tooj sib txuas rau qhov kev npaj kho yuav xav tau.
Tau txais ib nqe lus uas phim koj txoj kev
Xa qhov ntev ntawm txoj kev, qhov hloov pauv thiab cov qauv ntawm tus lej, hom fiber ntau thiab qhov yuav tsum tau muaj hluav taws kub. Glory Optical teev ua-rau-ntev LC duplex sib dhos hauv nwsfiber optic cable sib dhosntau thiab muajOEM / ODMkev xaiv rau kev tsim kho.
Thov ib daim Quote Hu rau pab pawg engineeringQhov chaw
- Cisco,Cisco 10GBASE SFP + Modules Cov Ntaub Ntawv Ntawv(SR, LR thiab BiDi ncav cuag, connector ceeb toom, yam tsawg kawg nkaus nrug).
- Fiber Optic Association,Fiber Optic Cables(kev tsim kho cable, kev ntsuas hluav taws, armored cable grounding, khoov vojvoog, spare fibers).
- Fiber Optic Association,Fiber Optic Installation(chaw installation, ntsug khiav, firestopping, hybrid cable).
- Fluke Networks,Cable Test 101: Tab sis tus qauv hais tias 0.75 dB!(kev sib txuas poob, kev siv nyiaj txiag, kev sim Tier 1).
- Eaton,N455-000-WH-KJ duplex multimode LC keystone coupler(piv txwv li cov npe khoom).
- TIA,ANSI/TIA-568.3-E Optical Fiber Cable thiab Cheebtsam Standard(qhov chaw kho qhov muag fiber ntau cable thiab cov khoom siv).
- Glory Optical,Yuav ua li cas hloov tau Fiber Optic Cable? Khoov Limits, Tolerance & Tiag Tiag (2026).