OptiTap Splitter Terminal Expansion: Compatibility Guide

Oct 16, 2026

Tso lus

Lub OptiTap splitter lub davhlau ya nyob twg tuaj yeem ntxiv cov neeg siv khoom chaw nres nkoj mus rau ib qho chaw fiber ntau-rau-lub-tsev (FTTH) uas twb muaj lawm thaum cov tswv yim haum rau kev sib txuas thiab cov peev nyiaj kho qhov muag txaus rau qhov sib cais ntxiv. Pib los ntawm kev txheeb xyuas qhov kev sib txuas pub noj thiab cov kab txuas uas koj xav khaws cia. Tom qab ntawd xaiv qhov sib cais thiab sib dhos ua tiav rau kev pom zoo rau cov qauv.

Koj cov ceg OptiTap puas tuaj yeem txhawb nqa ntau tus neeg siv?

Qhov chaw nres nkoj tsis siv yog qhov pib muaj txiaj ntsig. Nws cov dej ntws ntws tawm, cov nyiaj kho qhov muag seem thiab cov neeg siv kev txhawb nqa suav txiav txim siab pes tsawg tus neeg siv khoom ntxiv uas tuaj yeem pab. Ib qho kev faib tawm fiber ntau yuav muab lwm txoj hauv kev yog tias qhov kev faib qis qis yuav siv ntau dhau ntawm cov peev nyiaj muaj.

  • Nrog rau qhov chaw nres nkoj thiab qhov chaw kho qhov muag txaus, ntsuas qhov qis qis 1 × 2, 1 × 4 lossis 1 × 8 splitter.
  • Nrog rau kev faib khoom seem fiber ntau, sib piv cov khoom siv hluav taws xob sib cais nrog txuas ntxiv qhov sib faib uas twb muaj lawm.
  • Nrog rau qhov chaw nres nkoj nyob, npaj cov neeg siv khoom tam sim no tsiv teb tsaws ua ntej muab cov khoom tawm tshiab.

Suav cov neeg siv khoom tshiab, txhua qhov kev pabcuam raug txav mus los thiab cov txiaj ntsig tau khaws tseg rau yav tom ntej. Yog tias ib tus neeg siv khoom uas twb muaj lawm siv cov khoom tso tawm ntawm 1 × 8 splitter, xya txoj haujlwm tseem nyob ua ntej khaws cov khoom seem. Tus neeg teb xov tooj kho qhov muag kab davhlau ya nyob twg (OLT) tseem qhia nws lub peev xwm thoob plaws ceg; nws tso cai cais thiab kho qhov muag network davhlau ya nyob twg (ONT) suav teev cov kev pab cuam txwv.

Ib qho yooj yim splitter davhlau ya nyob twg faib ib txoj hauv kev kho qhov muag ntawm ob peb qhov tso zis. Ib ceg unsplit sib dhos nqa cov fibers cais rau nws cov zis. Daim duab kos qhia txog qhov ua haujlwm uas koj xaj.

Muab cov khoom sib txuas thiab cov neeg siv khoom poob

Cov tswv yim thiab cov khoom tawm muaj cov haujlwm sib cais. Cov tswv yim txuas mus rau cov khoom noj uas twb muaj lawm; txhua qhov tso zis txuas mus rau tus neeg siv khoom poob cable. Daim ntawv qhia kev sib txuas muaj txiaj ntsig npe ob qhov chaw sib ntsib ntawm txhua qhov sib koom ua ke, suav nrog txhua tus hloov pauv.

Kev sib txuas hauv koj qhov project

Dab tsi txiav txim siab qhov sib txuam

Pub los ntawm qhov chaw nres nkoj terminal uas twb muaj lawm

Tus qauv davhlau ya nyob twg thiab txais-chaw nres nkoj interface txiav txim siab lub rooj sib txoos tshiab cov tswv yim.

Pub los ntawm cov hlau lead uas twb muaj lawm

Cov hlau lead lub ntsaws txiav txim siab qhov tau txais cov tswv yim, lossis ob sab ntawm lub npe hloov pauv.

Rov qab siv cov neeg siv khoom tam sim no

Tus qauv drop-plug txiav txim qhov yuav tsum tau tso zis receptacle ntawm lub davhlau ya nyob twg tshiab.

OptiTap thiab hauv kab OptiTap yog cov kev xaiv sib txawv

Corning tusMultiPort Flex Splitter Terminal daim ntawv qhiatxheeb xyuas cov tswv yim code 43 raws li OptiTap SC/APC thiab code 48 raws li hauv-kab OptiTap. Tib tsev neeg muaj xws li 1 × 2, 1 × 4 thiab 1 × 8 splitters rau branching ntawm lub davhlau ya nyob twg uas twb muaj lawm. Xaiv qhov piv thiab xaiv cov tswv yim yog kev txiav txim siab cais.

Rau kev siv catalog tiag,Corning MSF-F84848R43Ftau teev nyob rau hauv kab OptiTap 1 × 8 davhlau ya nyob twg uas tsis muaj qhov chaw nres nkoj nthuav dav. suav nrog tus lej tag nrho thaum piav txog cov cuab yeej teeb tsa: "yim-port OptiTap davhlau ya nyob twg" tawm tawm cov ntaub ntawv uas tuaj yeem hloov pauv qhov kev sib txuas.

Yees duab lub ntsej muag mating, coupling thiab cov khoom npe ntawm cov khoom noj uas twb muaj lawm thiab ib qho poob. Ua ke nrog cov lej lej, cov no pab txheeb xyuas qhov yuam kev, kev ntsuas qhov ntsuas thiab foob. Kom tus neeg muag khoom paub meej txog qhov tshwj xeeb Glory-to-Corning khub hauv kev teeb duab kos duab thiab cov qauv ntaub ntawv.

SC/APC piav qhia txog qhov kho qhov muag interface thiab polish; lub tsev nyob sab nraum zoov muab kev kaw thiab kaw.Corning txheeb xyuas OptiTap ua ib leeg-fiber thiab OptiTip li multifiber. Rau cov ntsiab lus mechanical, saibLub hwjchim ci ntsa iab cov lus qhia rau kev xauv cov fiber ntau txuas. Qhov twg cov cuab yeej ntsia tau siv Pushlok, txheeb xyuas qhov tsim nyog converter los ntawmCorning's Evolv accessory systemthiab suav nrog ob sab ntawm daim ntawv qhia kev sib txuas.

Khaws qhov sib cais ntxiv hauv cov peev nyiaj kho qhov muag

Cov peev nyiaj xav tau qhov poob ntawm qhov tiav splitter los ua ke, qhov ntxiv poob thiab ib qho kev sib txuas sib txawv. Siv txoj hauv kev nrog qhov poob loj tshaj plaws, uas yuav txawv ntawm txoj kab ntev tshaj plaws. Kev sib piv engineering yuav tsum npog lub network qhov xav tau wavelengths thiab cov lus qhia.

Example expansion path from an existing feed through a splitter and customer drop, with external connections C1, C2 and C3.

Piv txwv daim ntawv qhia kev sib txuas. Cov xub taug ib txoj hauv kev rau cov neeg siv khoom; PON tsheb khiav hauv ob qho tib si. Lwm cov txiaj ntsig xav tau lawv tus kheej kev kuaj xyuas.

C1 koom nrog cov khoom noj uas twb muaj lawm rau cov tswv yim, C2 koom nrog qhov tso zis rau qhov poob, thiab C3 txuas qhov poob ntawm qhov chaw. Qhov piv txwv qhov poob qis kawg ua ntej C1, thiab nws qhov kev sib dhos poob tsis suav nrog C1 thiab C2. Daim ntawv ceeb toom poob yuav tsum qhia qhov ntsuas qhov kawg, lossis cov dav hlau siv, yog li txhua qhov kev sib txuas raug suav ib zaug.

Piv txwv kev npaj ua piv txwv ntawm 1310 nm: 28.0 dB txoj kev txwv, 14.0 dB uas twb muaj lawm ntws ntws thiab 3.0 dB engineering reserve. Qhov kev poob siab yog 8.0 dB rau 1 × 4 thiab 11.0 dB rau 1 × 8. Tshiab poob fiber ntau, peb mating khub thiab ob splices ntxiv 1.9 dB. Tag nrho cov txiaj ntsig yog qhov piv txwv piv txwv.

Cov neeg sib tw

Qhov tshwm sim nrog lub teev tseg

1 × 4 sib dhos

26.9 dB tag nrho faib; 1.1 dB tseem nyob hauv qhov kev txwv.

1 × 8 sib dhos

29.9 dB tag nrho faib; Tshaj li qhov xav tau los ntawm 1.9 dB.

Ntawm no, qhov sib cais qis haum rau qhov nyiaj pub dawb; qhov loj dua yuav tsum muaj txoj hauv kev qis dua lossis lwm qhov pub. Rau qhov kev pom zoo, engineering kuj kuaj xyuas qhov tsawg kawg nkaus poob thiab receiver overload. CovFOA network-tsim siv sivpiav qhia txog qhov kev poob ntawm txoj kev tsis zoo cuam tshuam li cas rau cov khoom siv xaiv qhov kev txwv qhov muag.

Xaiv lub Glory davhlau ya nyob twg nyob ib ncig ntawm lub voj voog thiab qhov chaw

Ob lub Hwj Chim Loj hauv qab no suav nrog cov kev xaiv sib npaug sib npaug. Pib nrog lub Circuit Court thiab connector ua ke, ces sib piv qhov chaw xav tau rau lub cev, txuas plugs thiab cable routing. Flexible leads cia cov neeg teeb tsa tso cov kev sib txuas ntawm tus kheej nyob ib puag ncig kev thaiv hauv lub qhov rooj lossis lub pedestal.

Glory Flexible Service Terminal product photograph with a body marked 1:8 and capped branch leads.

Flexible Service Terminal / Fiber Access Terminals

Glory teev 1 × 2, 1 × 4 thiab 1 × 8 splitter xaiv, nrog 0.3 m input lead thiab 0.5 m tso zis lead. Qhov no yog qhov chaw pib thaum cov hlau lead mus txog thiab qhov chaw routing yog qhov tseem ceeb rau kev nthuav dav.

Sib piv cov ntawv luam tawm ntev nrog qhov kev ncua deb ntawm cov khoom noj uas twb muaj lawm rau cov neeg siv khoom sib txuas tau npaj tseg.

Saib Flexible Service Terminal

Glory MultiPort Flex Splitter Terminal product photograph with a cylindrical body and capped input and output leads.

MultiPort Flex Splitter Terminal

Lub hwjchim ci ntsa iab muab 1 × 2 thiab 1 × 4 qhov duab kos thiab sau PLC splitter teeb tsa los ntawm 1 × 16. Siv cov kab no los tham txog qhov yuav tsum tau ua hauv Circuit Court thiab tshuaj xyuas cov duab kos ua ntej teeb tsa qhov teeb tsa.

Rau cov ceg neeg sib npaug, qhia PLC version. Qhov ntau kuj teev cov tsis sib npaug, uas xav tau kev xaiv sib txawv.

Saib Flex Splitter Configurations

Tawm hauv chav kom txuas thiab hloov qhov poob, txhawb nqa txhua tus txhuas thiab tuav cov kab hluav taws xob khoov lub vojvoog. Rau txoj kev dav dua lossis kev hloov pauv hloov pauv,Glory's ODN phau ntawv qhia kev npajnpog lub network layout thiab daim nqi ntawm cov ntaub ntawv.

Pom zoo ib qho ua tiav ua ntej kev txiav txim ntau

Kev pom zoo ua piv txwv txuas cov ntawv qhia tshwj xeeb rau lub rooj sib txoos uas yuav muab. Siv cov kev xaiv pub noj interface, cov neeg siv khoom poob thiab ib qho kev hloov pauv, tom qab ntawd khaws qhov kev pom zoo kos duab kho ntawm qhov kev yuav khoom.

  1. Mate tus qauv nrog rau qhov xav tau txais. Ua raws li cov txheej txheem kev tu thiab kev sib koom ua ke, thiab xyuas tias lub rooj sib txuas thiab lub rooj zaum raug kaw.
  2. Ntsuas txhua qhov tso zis ntawm qhov pom zoo wavelengths thiab cov dav hlau siv. Khaws qhov ntxig-poob thiab txhua qhov kev xav tau rov qab-tsis tau tawm tsam daim ntawv qhia chaw nres nkoj.
  3. Tshawb xyuas cov ntaub ntawv pov thawj sab nraum zoov rau kev sib txuas, suav nrog cov hloov pauv thiab lub kaus mom ntawm cov khoom siv tsis siv. Khaws cov qauv uas tau txais, cov ntaub ntawv xeem thiab cov npe khoom ua ke.

Xa cov ntsiab lus uas ua rau kev tsocai siv tau

Pib nrog lub davhlau ya nyob twg uas twb muaj lawm los yog txuas ib feem ntawm tus lej thiab cov duab ntawm cov khoom noj thiab poob xaus. Ntxiv cov ntsiab lus hauv qab no kom tus neeg xa khoom tuaj yeem tshaj tawm ib qho kev sib dhos kom meej meej:

  • Yuav tsum tau faib piv, cov neeg siv khoom tawm thiab cov haujlwm tshwj xeeb.
  • Upstream cais txoj kev npaj, tshuav nyiaj kho qhov muag thiab kev ua haujlwm wavelengths.
  • Installation qhov chaw, lead-ntev yuav tsum tau thiab mounting kev npaj.
  • Kom muaj nuj nqis, lub sij hawm xa khoom thiab cov khoom siv ntxiv rau suav nrog, xws li lub kaus mom, hloov pauv, cov hlua khi thiab cov ntawv lo.

Nug rau daim ntawv teev npe thiab teeb tsa kev teeb tsa nrog cov lus tsocai, ua raws li cov qauv kev pom zoo ua ntej kev txiav txim ntau. Qhov no muab engineering ib lub rooj sib dhos uas tau txiav txim siab los tshuaj xyuas thiab ua kom muaj kev sib raug zoo rau kev sib piv cov nqi.

Xa koj lub davhlau ya nyob twg uas twb muaj lawm lossis kev xa xov cable thiab tus lej ntawm cov neeg siv khoom xav tau. suav nrog cov duab txuas los pib xaiv cov tswv yim thiab tso zis.

Sib tham txog koj qhov Expansion Configuration

Xa kev nug