Pre-Connectorized ODN RFQ Daim Ntawv Teev Npe rau FTTH Kev Muag Khoom

Oct 13, 2026

Tso lus

Pre-connectorized ODN cov qauv tuaj txog raws li plaub yam ntaub ntawv: Suav cov qauv kev lag luam (YD / T), ETSI cov ntaub ntawv kev, Telcordia thiab IEC xeem txoj kev, thiab tus neeg muag khoom tus kheej cov ntaub ntawv. Lawv siv cov yardsticks sib txawv rau qhov poob, kev tiv thaiv ingress thiab tuav cable. Ib qho RFQ uas sau npe tsuas yog tus lej qauv tso cai rau txhua tus neeg muag khoom teb cov lus nug sib txawv. Phau ntawv qhia no qhia txhua yam uas koj yuav (lub davhlau ya nyob twg, connector interface, cable sib dhos, daim ntawv lo thiab qhov txuas txuas) rau cov ntaub ntawv thov thiab cov pov thawj uas koj tuaj yeem thov.

Teb ceev

  • Peb Suav cov qauv pom zoo tam sim no npog sab nraum zoov ua ntej txiav tawm.YD/T 6889.1-2026 (lub thawv xa khoom) thiab YD/T 6954-2026 (kab sib dhos) tau siv rau lub Cuaj Hlis 1, 2026. YD/T 6889.2-2026 (splitter lub thawv) yuav siv tau rau 1 Kaum Ib Hlis 2026.
  • YD/T 7067-2026coj los siv rau 1 Cuaj hlis 2026. Nwscov ntaub ntawv raug cainpog lub cabling system, nrog rau kev sib txuas attenuation, xeem txoj kev thiab kev lees txais installation.
  • Xaiv cov ntaub ntawv los ntawm qhov project scope.Siv tus neeg yuav khoom cov khoom siv thiab cov kev xav tau hauv lub network los xaiv cov kev cai ETSI, YD/T, Telcordia thiab IEC. Kev siv cov lus xaiv kho vajtse tsis tsim kom muaj kev ua raws li kev ua tiav digitalized Quick ODN specification.
  • Txhais txoj cai lees txais:cov khoom ntsuas, tus kheej txwv, ib qho piv txwv ntxiv txheeb cais, mating xeev, wavelength, xeem ntev thiab cable profile. Ib qho piv txwv lossis feem pua ​​​​ntawm cov txheej txheem ib leeg tsis teeb tsa qhov siab tshaj plaws rau txhua chav.
  • Nug rau daim ntawv qhia txog tus qauv.Tus lej qauv ntawm daim ntawv teev cov ntaub ntawv yog kev thov; ib daim ntawv qhia theem-qib rau qhov tseeb configuration yog pov thawj.

Txhais lub hardware thiab system Scope ua ntej

Phau ntawv qhia no tsom rau cov terminals, connector interfaces, cable sib dhos thiab lawv cov ntaub ntawv txais. ODN txhais tau tias optical faib network; RFQ txhais tau hais tias thov kom hais. Pre-terminated thiab pre-connectorized piav txog lub Hoobkas ua tiav kev sib txuas ntawm no; ib qho digitalized Quick ODN kuj suav nrog cov ntaub ntawv network thiab kev tswj hwm kev ua haujlwm.

  • Kev yuav khoom Hardware:txheeb xyuas lub thawv, cable thiab interface yuav tsum tau muab, nws qhov chaw teeb tsa thiab cov khoom siv sib txuas. Ib puag ncig yog qhov xaiv qhov kev xeem qhov hnyav:IEC 61753-1: Covtxhais cov kev khiav hauj lwm kev pab cuam ib puag ncig thiab cov txheej txheem xeem, qhov hnyav thiab dhau / tsis ua haujlwm tom qab txhua tus, thiab ETSI TR 103 775 cov ntsiab lus 5.3.4 cov ntsiab lus passive ntsiab - FAT, kaw, splitters thiab connectors - ntawm nws. Ib daim ntawv qhia txog kev txhawb nqa tsuas yog kev teeb tsa thiab cov cai uas nws npog.
  • Digitalized Quick ODN: ETSI TS 104 021-1, clauses 1 and 6.1, hais txog cov kev sib tham digitalized thiab tsom mus rau nws cov kev sib tham sib tham ntawm qhov tsis sib xws ntawm QuickConnect networks. Txais yuav xaiv lub cev uas yuav tsum tau them raws nraim cov nqe lus uas koj teev; ib daim ntawv thov tag nrho tseem hu rau cov pov thawj ntawm kev txheeb xyuas, cov ntaub ntawv kho qhov muag thiab kev tswj hwm kev ua haujlwm.
  • Mounted cable system:txhais txoj kev kho qhov muag kom tiav, kev siv nyiaj poob nyiaj thiab kev lees txais daim teb. Qhov twg YD/T 7067-2026 tau txais yuav, tau txais nws cov ntawv nyeem thiab nqa nws cov kev xav tau rau hauv txoj kev npaj ntawd; nws cov pej xeem muaj peev xwm npog qhov txuas txuas thiab kev sim, thiab cov lej txwv zaum hauv cov ntawv sau tag nrho. Rau qhov kev tsim ua ntu zus thoob plaws plaub ntu ODN, saibFTTH ODN Deployment Guide: Standards, Component Selection & Field Practice.

Pre-connectorized ODN cov qauv: qhov twg cov ntaub ntawv sawv

Cov lus teev npe dab tsi ua ntej-connectorized ODN RFQ tuaj yeem siv tau raws li 13 Lub Kaum Hli 2026. Cov npe lus Askiv ntawm Suav cov qauv yog Kev Txhais Lus Txhais; Cov npe suav suav suav nrog kom koj tus neeg muag khoom cov ntaub ntawv tuaj yeem sib phim raws nraim.

Cov ntaub ntawv sib txuas ua ntej ODN RFQ tuaj yeem siv tau, nrog cov xwm txheej luam tawm raws li 13 Lub Kaum Hli 2026
Cov ntaub ntawv Qhov nws npog Hnub tim xwm txheej Xwm thiab scope sau ntawv
YD/T 6889.1-2026 Sab nraum zoov kev sib txuas ua ntej kev sib txuas cov chaw, Ntu 1: cable faib lub thawv Luam tawm 1 Lub Rau Hli 2026; pib txij lub Cuaj Hlis 1, 2026 Pom zoo (推荐性) tus qauv kev lag luam. Cov ntawv nyeem: tsim, tsim khoom thiab tshuaj xyuas cov thawv xa khoom ua ntej txiav tawm hauv ODN.
YD/T 6889.2-2026 Part 2: pre-terminated splitter davhlau ya nyob twg lub thawv Luam tawm 15 Lub Xya Hli 2026; nyob rau hauv yuam los ntawm 1 Nov 2026 (tseem tsis tau siv rau 13 Oct) Cov qauv kev lag luam pom zoo. Tib lub ntsiab lus raws li Ntu 1: tsim, tsim khoom thiab tshuaj xyuas.
YD/T 6954-2026 Pre-terminated sab nraum zoov cable sib dhos rau kev nkag mus rau tes hauj lwm Luam tawm 1 Lub Rau Hli 2026; pib txij lub Cuaj Hlis 1, 2026 Cov qauv kev lag luam pom zoo. Npog kev faib tawm thiab kev sau npe, kev ua haujlwm, kev sim, kev soj ntsuam xyuas, cim, ntim, khaws cia thiab thauj. Scope ntawv suav nrogtxais, uas 6889 series scope ntawv tsis.
YD/T 7067-2026 Pre-connected optical faib network cable system Luam tawm 1 Lub Rau Hli 2026; pib txij lub Cuaj Hlis 1, 2026; daim ntawv no . 106722-2026 Pej xeem Scope muaj xws li cov qauv system, fiber ntau thiab cable yuav tsum tau, txuas hardware, link attenuation, xeem txoj kev thiab kev tswj; siv rau kev tsim, ntau lawm, kev teeb tsa thiab kev lees paub. Tus lej clauses xav tau cov ntawv tag nrho.
ETSI TR 103 775 V1.1.1 ODN kev tsim kho sai thiab digitalization; suav nrog kev ua tau zoo Table 5-1 rau pre-connectorized cables Lub Yim Hli 2021 Daim ntawv qhia kev. Lo lus yog kev tawm tswv yim ("yuav tsum"), yog li nws muab lub hauv paus ntsuas koj tuaj yeem txais hauv RFQ.
ETSI TS 104 021-1 V1.1.1 ODN kev tsim kho sai thiab digitalization, Ntu 1: dav dav thiab kev taw qhia Lub Ob Hlis 2025 Technical Specification rau digitalized Quick ODN, suav nrog cov khoom siv thiab kev tswj hwm kev ua haujlwm. Txheeb xyuas cov kab lus kho vajtse uas tau xaiv cais los ntawm ib qho kev thov ua raws li qhov kev thov.
ITU-T L.208 (08/08/2019) Yuav tsum tau rau passive optical nodes: fiber ntau faib lub thawv Hauv quab yuam Annex B xeem qhov kev pab cuam: cable tuav, khoov, torsion, cuam tshuam, kub cycling, rov nkag, ntsev pos huab, aggressive media, ntxiv rau qhov ntsuas qhov muag.
Telcordia GR-3120-CORE, Issue 2 Hardened fiber optic connectors thiab adapters 2013; Cov npe tam sim no hauv Intertek Inform catalog tshuaj xyuas thaum Lub Kaum Hli 13, 2026 Tsab ntawv thiab xwm txheej txheeb xyuas ntawm qib catalog nkaus xwb; Cov ntawv sau tag nrho thiab cov kev hloov pauv cais tsis raug tshuaj xyuas. Npe Qhov Teeb Meem 2 thiab cov kev hloov kho thiab cov nqe lus uas siv tau hauv lub sijhawm ua haujlwm; xav kom daim ntawv tshaj tawm los txheeb xyuas tib lub hauv paus.
IEC 60529 (TSI) Degree ntawm kev tiv thaiv muab los ntawm enclosures (IP Code) Tsab ntawv 2.2 consolidated version, 2013 Classifications enclosures rau cov khoom siv hluav taws xob txog li 72.5 kV.
IEC 61753-1: Cov Fiber optic interconnecting devices thiab passive Cheebtsam - Kev ua tau zoo tus qauv, Ntu 1: General thiab kev taw qhia Thib ob, 2018 (corrigendum May 2019; AMD1: 2020) Txhais cov kev pabcuam kev ua haujlwm thiab, hauv Annex A, cov qauv ntsuas ntsuas, qhov hnyav thiab dhau / tsis ua haujlwm rau txhua tus. Cov vaj tse tiv thaiv siv pawg A (aerial), G (hauv av) thiab S (subterranean); Cheebtsam siv C, OP, OP +, I thiab E, nrog rau HD suffix rau vaj tse uas tseem nqa cov khoom siv hluav taws xob. Conformance yog ib qho kev qhia tawm ntawm kev ua haujlwm kho qhov muag raws li qhov hnyav; Kev cia siab rau lub neej yog ib txoj haujlwm cais raws li IEC 62005 series.
Verification Scope - dab tsi tau kuaj

YD/T hnub tim thiab cov lus hais saum toj no yog los ntawm cov ntaub ntawv pej xeem; lawv tsis yog ib qho kev tshuaj xyuas ntawm cov qauv suav ua tiav. ETSI cov ntaub ntawv qhia txog cov khoom siv hauv phau ntawv qhia no. GR-3120 nkag mus siv cov khoom lag luam catalog rau ib tsab ntawv metadata, tsis yog pov thawj ntawm cov khoom lag luam. IEC 61753-1 tau nyeem nyob rau theem ntawm nws cov peev txheej thiab qeb txhais. Sau cov ntawv tseeb thiab cov kev hloov kho uas tau txais los ntawm qhov project ua ntej tshaj tawm RFQ.

Qhov kev pom zoo Suav tus qauv muab rau tus neeg yuav khoom xa tawm

Lub platform teev YD / T 6889.1, YD / T 6889.2 thiab YD / T 6954 raws li cov qauv kev lag luam pom zoo. Lawv cov koom haum sau ntawv sau npe suav nrog cov neeg ua haujlwm, cov koom haum tsim qauv, cov chaw kuaj sim thiab cov chaw tsim khoom. Rau ib txoj haujlwm txawv teb chaws, txheeb xyuas seb tus neeg yuav khoom puas tau txais cov kev cai tshwj xeeb raws li kev yuav khoom lossis siv lawv tsuas yog tsim cov ntaub ntawv siv; tsis txhob xav tias txhua qhov project txais tib cov ntaub ntawv. Lawv tsis yog cov kev cai thoob ntiaj teb, thiab tus neeg muag khoom cov lus hais tias tus qauv "ua raws" nqa hnyav tsuas yog thaum daim ntawv tshaj tawm npe cov ntaub ntawv, ib tsab, nqe lus, qhov kev xeem thiab cov qauv raug kuaj.

Glory txoj hauj lwm.Lub hwjchim ci ntsa iab tsis lees tias txhua yam khoom ua raws li cov ntaub ntawv no. Rau ib qho qauv hauv koj lub BOM, nug rau daim ntawv tshaj tawm uas npog cov qauv thiab teeb tsa.

Sib piv qhov poob, kev tiv thaiv thiab khaws cia rau tib lub hauv paus

Tib yam khoom tshwm nyob rau hauv ob peb cov ntaub ntawv nrog txawv ciam teb. Lub rooj teeb tsa cov kev cai luam tawm ntawm ib sab ntawm ob nplooj ntawv Glory cov khoom lag luam los qhia tias yog vim li cas RFQ yuav tsum hais tias lub yardstick twg siv. Cov duab yeeb koob yog lub tuam txhab luam tawm cov ntaub ntawv tseem ceeb, teev rau kev sib piv; lawv tsis yog thov kom ua raws li ETSI lossis YD/T cov ntaub ntawv. Nyeem ob kab ntawv raws li kev ntsuas sib txawv, tsis sib tw cov qhab nia: ETSI cov duab sib txuas yog cov txheeb cais sib cais, thaum lub Hwj Chim adapter-chaw nres nkoj daim duab yog ib qho txiaj ntsig ntawm ib qho nqi ntawm ob lub voj voog ruaj khov. Rau qhov kev pab cuam enclosure-theem qab cov lej, saibFiber Distribution Box FAT: Vibration & Optical Tests.

Insertion poob, rov qab poob, sealing, tuav thiab hnub nyoog: luam tawm ETSI cov cai ntawm ib sab ntawm ob lub Hwjchim ci ntsa iab luam tawm cov ntaub ntawv tseem ceeb

 

Khoom ETSI TR 103 775 (2021) ETSI TS 104 021-1 (2025) Glory luam tawm cov ntaub ntawv
Insertion poob Ib leeg-ntxhais cable IL Tsawg dua lossis sib npaug ntawm 0.3 dB nrog qhov nruab nrab Tsawg dua lossis sib npaug rau 0.1 dB; multi-core feeder Tsawg dua los yog sib npaug rau 0.35 dB. Random-mated single-core connectors: txhais tau tias tsawg dua lossis sib npaug rau 0.12 dB thiab tsawg kawg 97% ntawm kev sib txuas Tsawg dua lossis sib npaug rau 0.25 dB; multi-core: tsawg kawg yog 97% Tsawg dua lossis sib npaug rau 0.5 dB. Cov feem pua ​​​​cov txheej txheem no tsis qhia meej txog qhov txwv siab tshaj plaws rau txhua qhov kev sib txuas. Distribution cables: nruab nrab attenuation ntawm random mated ib leeg-core hardened connectors Tsawg dua los yog sib npaug rau 0.08 dB. GL-FTB-10E: Tsawg dua lossis sib npaug li 0.2 dB ntawm txhua qhov chaw nres nkoj adapter, 1310 thiab 1550 nm, tau hais tias yog lub adapter-port interface nkaus xwb. Sticklok: siab tshaj IL 0.4 dB rau cable-profile los ua ke; ceg terminals Tsawg dua los yog sib npaug rau 0.45 dB.
Rov qab poob Ntau dua lossis sib npaug rau 60 dB (APC), Ntau dua lossis sib npaug rau 50 dB (UPC) Tsis muaj daim ntawv teev nyob rau hauv cov nqe lus tshuaj xyuas GL-FTB-10E: APC Ntau dua lossis sib npaug rau 60 dB, UPC Ntau dua lossis sib npaug rau 50 dB
Ingress thiab cuam tshuam Kev ntsuas kev sib khi ntawm −15℃thiab +45℃tom qab kev sim tshuab; 40 kPa nruj test IPx5 (them nyiaj siv ua haujlwm) lossis IPx8 (hauv av) rau lub thawv, hloov pauv thiab cov khoom sib txuas; IK08 (overhead) lossis IK09 (hauv av) rau lub thawv GL-FTB-10E: IP65 vaj tse nrog IP67 ib-chaw nres nkoj adapter ntsaws ruaj ruaj. Tus Qauv Zauv: IP68 thiab IK08.
Connector-rau-cable retention Poob (ib leeg-ntxhais): 300 N rau 2 feeb ntawm ib lub cable rau qhov ntsuas kub, ΔIL Tsawg dua lossis sib npaug rau 0.2 dB. Multi-core feeder: 800 N, ΔIL Tsawg dua lossis sib npaug rau 0.5 dB, RL Ntau dua lossis sib npaug rau 60 dB. Distribution cable connectors Ntau dua los yog sib npaug rau 800 N; poob cable connectors Ntau tshaj los yog sib npaug rau 300 N Sticklok, los ntawm cable profile: 600 txog 1200 N rau 2 feeb thiab 200 txog 400 N rau 10 feeb
Kub thiab kev laus Kev khiav hauj lwm −40 rau +70℃; caij tsheb kauj vab −40 rau +65 degree, 12 cycles, 4 h nyob; 1000 h ntawm +75℃thiab 95% RH, ΔIL Tsawg dua lossis sib npaug rau 0.2 dB 1000 h ntawm +75℃thiab 95% RH GL-FTB-10E: −40 rau +85℃ua haujlwm. Sticklok: −18 txog +75℃kev khiav hauj lwm, −18 rau +40℃installation.
Kev piav qhia poob nyiaj txiag - qhov kev xav zoo

Rau 6 tus khub sib txuas sib txuas, qhov kev xav nruab nrab poob ntawm 0.12 dB ib khub muab kev npaj kwv yees ntawm 0.72 dB. Qhov poob ntawm ib qho txuas tshwj xeeb los ntawm kev ntsuas qhov txuas. HauvETSI TR 103 775, Table 5-1, tus nqi 0.25 dB siv rau tsawg kawg 97% ntawm kev sib txuas ntawm ib leeg-ntxhais sib txuas; nws tsis yog qhov siab tshaj plaws rau txhua tus khub.

Yog tias qhov project cais tshwj xeeb thiab txheeb xyuas tus kheej txwv ntawm 0.25 dB rau txhua qhov ntawm rau qhov sib txuas, lawv qhov kev sib txuas ua ke-tsawg nyiaj yog 1.50 dB. Qhov kev txwv ntawm tus kheej yog qhov yuav tsum tau ua, tsis yog qhov tshwm sim ntawm 97% cov qauv. suav nrog fiber ntau, splitter thiab splice poob thiab engineering margin cais, thiab ntsuas txoj kev teeb tsa.

Lub pre-connectorized ODN qauv-rau-RFQ matrix

Siv ib kab rau ib yam khoom ntawm koj daim nqi ntawm cov ntaub ntawv. Xaiv cov ntaub ntawv uas haum rau cov khoom thiab qhov project scope; daim ntawv teev npe tsis yog qhov yuav tsum tau siv txhua daim ntawv rau txhua tus qauv. Txhua kab qhia cov pov thawj los thov thiab nws cov kev txwv. Rau kev sib piv ua haujlwm ntawm yuav ua li cas cov neeg muag khoom hais txog tib lub thawv xa khoom, saib covFTTH Fiber Distribution Box RFQ Qhia.

Cov qauv-rau-RFQ matrix: ib kab ib yam khoom ntawm daim nqi ntawm cov ntaub ntawv

 

Yam koj yuav Cov ntaub ntawv xa mus Cov ntaub ntawv pov thawj thov Qhov twg cov pov thawj nres
Sab nraum zoov FAT lossis faib lub thawv YD / T 6889.1 rau cov thawv xa khoom lossis 6889.2 rau cov thawv cais lub thawv thaum tau txais; xaiv ETSI TS 104 021-1 clause 6.2 cov cai; ITU-T L.208; IEC 61753-1 rau qeb kev pabcuam-ib puag ncig; IEC 60529 (TSI) Hom-test daim ntawv qhia rau tus qauv thiab configuration (ports, splitter, cable nkag); IP code teev ib lub caij thiab xeem lub xeev; cable-nkag sealing txoj kev thiab txoj kab uas hla; per port IL Cov kev ntsuam xyuas lub thawv piav qhia txog kev kho vajtse. Qhov txuas txuas tseem xav tau kev ntsuas.
Hardened connector thiab adapter interface GR-3120-CORE Issue 2 (2013), nrog rau kev hloov kho thiab cov nqe lus sau tseg; xaiv ETSI TS 104 021-1 clauses 6.2.4 txog 6.2.6; IEC 61753-1 rau qeb kev pabcuam-ib puag ncig; Cov txheej txheem IEC 61300 cuam tshuam Kev kos duab interface; converter daim ntawv nrog ntsuas poob ntawm txhua khub niam txiv; tensile cov ntaub ntawv los ntawm cable profile thiab lub sijhawm kuaj Ib tug xauv connector paub meej tias txhua yam kev koom tes nkaus xwb. Glory's Sticklok nplooj hais tias kev sib khi, qhov kawg ntawm lub ntsej muag huv thiab poob tseem xav tau kev kuaj xyuas.
Pre-terminated cable los ua ke YD/T 6954-2026; ETSI TR 103 775 Table 5-1; tus txheej txheem cable-theem koj teev rau cable nws tus kheej Per-assembly IL thiab RL ntawm qhov teev wavelengths; xaj ntev thiab kam rau ua; daim ntawv lo; rub lub taub hau qhov ntev; cov duab kawg Daim ntawv qhia txog lub Hoobkas npog lub rooj sib txoos. Txoj kev tshawb fawb thiab rub cov kev txwv txiav txim siab seb nws puas tuaj yeem ntsia tau; saib Pre-Terminated Fiber Pulls: Plaub Daim tshev ua ntej koj xaj.
Cov ntawv sau thiab cov ntaub ntawv ETSI TS 104 021-1 clause 5 thiab QuickConnect cable clauses Cim code rau ib lub cuab yeej; zoo tib yam code ntawm ob lub connector kawg ntawm ib tug cable; pov thawj tias daim ntawv lo muaj sia nyob ntawm cov khoom lag luam kev sim ib puag ncig Cov ntawv sau txhawb nqa lub npe chaw nres nkoj. Lawv tsis hloov kho qhov muag kuaj.
Ua kom tiav ODN txuas ua ntej YD/T 7067-2026 qhov twg tau txais; ETSI TS 104 021-1 rau cov txheej txheem digitalized Quick ODN Kev kos duab; poob nyiaj txiag; clause-by-clause txoj kev lees txais, suav nrog cov haujlwm digital uas siv tau Txoj kev lees txais yuav tsum ua raws li cov cai tau txais thiab cov kev txwv qhov project. Kev teeb tsa-txuas thiab kev tswj hwm digital tau pom los ntawm txoj kev npaj ntawd, nrog cov ntaub ntawv qhia txog kev txhawb nqa pov thawj.

Xaiv cov ntaub ntawv pov thawj uas npog qhov yuav tsum tau ua

Ntsuam xyuas cov pov thawj tawm tsam qhov kev yuav khoom thiab qhov kev thov tau ua. Hom ntaub ntawv hauv qab no ua haujlwm sib txawv; lawv tsis yog universal qeb duas.

  • Design reference:txheeb xyuas cov ntaub ntawv txiav txim siab thaum lub sijhawm txhim kho; ib qho kev ntsuas dhau qhov tshwm sim los ntawm ib daim ntawv xeem.
  • Supplier Test Report:tuaj yeem txhawb nqa cov khoom xa tuaj raws sij hawm los yog kuaj kev tsim nyog. Txheeb xyuas tus qauv lossis tus lej xov tooj, txoj hauv kev, cov xwm txheej, cov txiaj ntsig, cov khoom siv calibration thiab qhov txuas mus rau qhov khoom siv.
  • Daim ntawv ceeb toom kuaj pom zoo:ntxiv cov kev xeem nyob rau hauv lub luag hauj lwm muaj peev xwm lees paub. Txheeb xyuas tias cov txheej txheem cuam tshuam yog nyob rau hauv lub chaw soj nstuam qhov kev lees paub thiab daim ntawv tshaj tawm hais txog tus qauv txiav txim. Kev lees paub thiab kev ywj pheej yog cais cov tshev.
  • Cov khoom pov thawj nrog kev soj ntsuam:tuaj yeem ntxiv kev saib xyuas kev tsim khoom tsis tu ncua nyob rau hauv ib qho kev npaj. Piv txwv li,TÜV SÜD's optical fiber certification tswvyimsuav nrog kev sim khoom thiab rov tuaj xyuas lub Hoobkas. Txheeb xyuas daim ntawv pov thawj siv tau, txheej txheem, qauv kev pab them nqi thiab tsis suav nrog; kev pab them nqi mus txog tus qauv ntau thiab xa cov ntawv pov thawj npe.

Rau txhua yam khoom, qhia cov pov thawj xav tau ntawm kev tsim nyog, kev xa khoom thiab qhov chaw txais. Ib tus neeg yuav khoom tuaj yeem thov kev sim ywj pheej rau lub interface tshiab lossis kev teeb tsa tsis tuaj yeem thiab siv cov ntaub ntawv pov thawj lub Hoobkas rau kev ntsuas kev xa khoom niaj hnub. Cov no yog cov kev xaiv ntawm kev yuav khoom los ua pov thawj rau qhov project, tsis yog qhov yuav tsum tau thov rau feem ntau cov haujlwm. Muab daim ntawv pov thawj rau qhov kev teeb tsa raug xaj thiab rau cov khoom xa tuaj uas nws npog. Rau qhov chaw nres nkoj-theem sealing pov thawj ntawm lub thawv sab nraum zoov, saibSab nraum zoov FDB Waterproof Sealing Txais: Cable Gland & Chaw Nres Nkoj Checklist.

ODN daim ntawv lees txais: pov thawj rau txhua theem

ETSI TR 103 775 clause 5.4 teev cov kev sib txuas ua ke ua ntej: xaiv cable ntev los ntawm kev tsim duab kos duab thiab rov kuaj dua, xyuas cov cables, nruab cov xaim xaim xaim, coil lawv, nruab qhov kaw, tsim cov tee, khiav kev kuaj xyuas tom qab kev teeb tsa, tom qab ntawd khiav qhov kev lees paub los ntawm cov qauv kev lees paub. Daim ntawv txheeb xyuas hauv qab no muab pov thawj rau cov kauj ruam ntawd.

  1. Nkag mus kuaj.Sib piv cov kab ntawv thiab lub thawv ntawv nrog cov ntawv ntim khoom thiab kev txiav txim. Paub meej tias daim ntawv lo code ntawm ob qhov kawg ntawm txhua kab.
  2. Hoobkas cov ntaub ntawv.Txuas txhua tus lej rau nws daim ntawv tshaj tawm: IL, RL, ntev, hom txuas thiab polish.
  3. Ntxuav thiab tshuaj xyuas ua ntej txhua tus khub thawj zaug.FOA cov lus qhia txogFTTH poob cablessau tseg tias cov khoom siv qias neeg ua rau muaj teeb meem hauv network feem ntau, thiabIEC 61300-3-35: 2022 Kev Ua Haujlwmtxhais qhov kawg-ntsej muag kev soj ntsuam. Kev soj ntsuam ntxiv attenuation thiab rov qab-tsis ntsuas.
  4. Mount, lub rooj thiab lub hau.Lub rooj zaum txhua qhov sib txuas hardened tag nrho, haum lub kaus mom plua plav ntawm cov chaw nres nkoj uas tsis siv thiab sau cov txheej txheem mounting.
  5. Ntsuas txoj kev teeb tsa.Ua raws li qhov kev pom zoo pom zoo: ntsuas qhov kawg, wavelengths, txoj kev, kev teeb tsa, ntsuas ntsuas, txwv thiab txiav txim siab txoj cai. Txheeb xyuas seb qhov ntsuas twg ua rau pom tag nrho txoj hauv kev poob thiab qhov twg nrhiav lossis qhia cov xwm txheej; ib daim ntawv tshaj tawm yuav tsum phim nws lub hom phiaj kev lees txais.
  6. Reconcile lub chaw nres nkoj register.Sib piv cov chaw nres nkoj lub cev thiab cov ntawv sau nrog cov ntaub ntawv tsim thiab hloov kho ob qho tib si.
  7. Kaw kev zam.Cov ntaub ntawv ua tsis tiav, tsis tau kuaj thiab rov ua dua cov khoom sib cais. Muab cov kev kho kom raug thiab rov ntsuam xyuas cov txiaj ntsig, lossis qhov kev tso cai sib txawv nrog nws cov peev txheej thiab qhov cuam tshuam. Khaws cov khoom uas tsis tau daws teeb meem.
  8. Tes tshaj.Xa cov kev pom zoo configuration, Hoobkas qhia, ntsuas teb, duab, chaw nres nkoj register thiab kaw deviation cav. Sau ntawv leej twg tso cai txais zaum kawg. Daim ntawv kos npe-rau-theem-rau-theem rau daim ntawv xa mus no tau teev tseg hauvFTTP Installation Acceptance Checklist.

Teem cov kev txwv ua ntej nug cov neeg xa khoom los hais

Cov haujlwm hauv qab no yog cov txheej txheem kev yuav khoom. Cov lej txwv tsis pub dhau los ntawm qhov yuav tsum tau ua thiab kev pom zoo tsim, tsis yog los ntawm tus nqi qis tshaj plaws hauv cov lus sib piv.

  1. Khov daim ntawv thov.Sau cov kev lag luam thiab tus neeg teb xov tooj specification, topology, installation ib puag ncig, chaw nres nkoj thiab interface hom, cable profile, PON system thiab kev khiav hauj lwm wavelengths. Sau cov qauv tsim thiab cov kab lus cuam tshuam.
  2. Faib nyiaj poob.Rau txhua txoj hauv kev, pib nrog kev tso cai poob rau qhov kev xaiv kho qhov muag, khaws cov khoom siv hluav taws xob, thiab faib nyiaj rau fiber ntau, splitters, splices thiab connector khub. Txhais kev ntsuas ciam teb kom muaj kev sib dhos lossis chaw nres nkoj poob raug suav ib zaug. Tshawb xyuas txhua qhov wavelength thiab txoj kev uas yuav tsum tau ua los ntawm tus tsim.
  3. Qhia seb yuav txiav txim siab li cas.Cais cov kev txwv ntawm tus kheej los ntawm cov qauv piv txwv thiab cov qauv feem pua. Qhia meej txog kev tsim nyog piv rau kev xa khoom xa tuaj, kev xaiv cov qauv, cov qauv ntsuas, kev kho tsis paub meej, rov kuaj dua thiab kev tuav ntawm cov chav tsis sib haum. Tsis txhob siv tus piv txwv dhau los los zam txim rau tus neeg tsis tau txais kev txwv.
  4. Pom zoo lub sijhawm.Tus neeg yuav khoom tus kws tshuaj xyuas kev daws teeb meem tsis sib haum xeeb ntawm tus qauv tsim, tau txais cov ntaub ntawv thiab muab qhov tseem ceeb ua ntej khoom plig. Qhov twg tus neeg muag khoom tsis tuaj yeem ua tau raws li qhov yuav tsum tau ua, thov kom muaj qhov sib txawv ntawm qhov nws cuam tshuam. Sau txhua qhov kev tso cai hloov pauv hauv kev yuav khoom tshwj xeeb thiab rov muab cov lus cuam tshuam, kom cov lus hais thiab cov khoom xa tuaj ob leeg siv tib cov ntawv nyeem.

Pre-terminated fiber ntau davhlau ya nyob twg RFQ: ib tug clause bank

Cov kab lus no tau sau rau tus neeg yuav khoom los tawm rau cov neeg muag khoom; cov neeg muag khoom teb lawv kab los ntawm kab. Siv lawv tom qab ua tiav cov sijhawm txwv saum toj no. Ua kom tiav cov kab kos, txuas cov duab kos thiab cov phiaj xwm kev sim, thiab kos cov kev xav tau ntawm cov ntaub ntawv pov thawj raws li muaj los yog tsis siv. Cov teb tsis daws teeb meem yuav tsum tau daws ua ntej kev txiav txim tso tawm.

Draft RFQ clauses rau lub pre-terminated fiber ntau davhlau ya nyob twg; bracketed teb yog sau los ntawm tus neeg yuav khoom

 

Clause Draft wording Cov ntaub ntawv pov thawj
Cov qauv hauv paus Rau txhua tus qauv, txheeb xyuas cov ntaub ntawv tau txais, ib tsab, kev hloov kho thiab cov kab lus. Qhia tus kws tshaj tawm cov ntawv tshaj tawm, tus lej, hnub tim thiab kuaj kev teeb tsa. Tshaj tawm cov kev sib txawv thiab cov kev xav tau uas tsis tau sim cais. Rau GR-3120-CORE, txheeb xyuas Qhov Teeb Meem 2 (2013) thiab cov kev hloov kho uas suav nrog hauv qhov kev sim pom zoo. Ua raws matrix thiab daim ntawv qhia index
Ingress tiv thaiv Lub xeev IP [__] rau IEC 60529 rau lub davhlau ya nyob twg raws li kev xa khoom, thiab npe cov khoom ntsuas (tsev, adapter foob lossis khub niam txiv) thiab nws lub xeev (capped, mated, nrog cable). Daim ntawv qhia txog IP nrog cov duab teeb tsa
Kev poob ntawm tus kheej Ntsuas txhua qhov muab [assembly / chaw nres nkoj / txhais mated kev sib txuas] ntawm [__] nm siv txoj kev thiab siv teeb tsa [__]. IL yuav tsum tsis pub tshaj [__] dB rau ib yam khoom ntsuas raws li txoj cai txiav txim [__]. Sau cov lej lej, ntsuas qhov kawg thiab cov txiaj ntsig. Qhia seb qhov txuas, fiber ntau, splitter thiab splice poob puas suav nrog. Per-serial cov qhabnias thiab xeem txoj kev
Ntxiv kev tsim nyog ntawm kev txheeb cais, yog tias tau txais Rau qhov kev ntsuam xyuas random-mating, qhia cov qauv xaiv [__], qauv loj [__], kev sib koom ua ke [__] thiab txoj kev [__]. Xav tau tus qauv txhais tau tias IL Tsawg dua lossis sib npaug rau [__] dB thiab tsawg kawg [__]% ntawm kev ntsuas kev sib txuas Tsawg dua lossis sib npaug rau [__] dB. Xa tag nrho cov txiaj ntsig thiab suav tshaj qhov pib. Txhais cov kev xeem rov qab thiab tso cai [__]; Cov txheej txheem no tsis zam qhov txwv kev xa khoom ntawm tus kheej. Daim ntawv ntsuam xyuas tag nrho, cov ntaub ntawv sib koom ua ke thiab cov ntsiab lus sau tseg
Rov qab poob Qhia RL ntawm [__] nm; yam tsawg kawg nkaus [__] dB rau [APC / UPC] polish. Ib-serial xeem ntawv
Cable tuav Connector-rau-cable tuav tsawg kawg [__] N rau [__] feeb ntawm cable profile [__], nrog ΔIL tsis saum [__] dB. Mechanical test report los ntawm cable profile
Interface compatibility Sau txhua lub hardened interface tsev neeg lub davhlau ya nyob twg lees txais, tus qauv converter rau txhua tus, thiab ntsuas qhov poob ntawm txhua tus converter khub. Compatibility kos duab thiab qauv kuaj
Cable profile Lub xeev sab nraud qhov ntev, cov duab (puab, tiaj tus, daim duab-8), hom fiber ntau thiab lub zog tus tswv cuab ntawm txhua qhov poob thiab xaim cable. Cable cross-section daim duab
Ntev txoj kev npaj Muab qhov ntev los ntawm daim ntawv teev npe nrog rau kev kam rau ua. Hais tias qhov kawg yog qhov kawg rub rau ib qho kawg-tawm cov rooj sib txoos. Lub sijhawm ntev
Kev txheeb xyuas Muab txhua lub thawv thiab cable ib lub cim tshwj xeeb. Cov cai ntawm ob qho tib si txuas kawg ntawm ib lub cable yuav tsum sib phim, thiab daim ntawv lo yuav muaj sia nyob ntawm cov khoom lag luam kev ntsuas ib puag ncig. Daim ntawv lo qauv thiab cov ntaub ntawv pov thawj
Splitter Qhia qhov sib piv, sib npaug lossis tsis sib npaug, IL ib qhov tso zis ntawm PON wavelengths ntawm cov txheej txheem xaiv, thiab kev sib xws. Splitter test report
Cov khoom seem suav nrog [__] lub kaus mom plua plav thiab cov khoom siv rau ib lub davhlau ya nyob twg. Cov ntawv ntim khoom
Kuaj pob Xa batch ID, serial tooj, lub ntsej muag lub ntsej muag, ntsuas cov txiaj ntsig, txoj hauv kev, txwv thiab kos npe rau cov khoom xa tuaj. suav nrog cov ntawv qhia tsim nyog uas xav tau los ntawm kev txiav txim. Cov ntaub ntawv xa khoom
Deviations thiab tso tawm Rau txhua kab RFQ, lub xeev tau txais kev txhawb nqa, kev sib txawv, lossis tsis qhia, nrog rau daim ntawv qhia siv. Tshaj tawm qhov kev thov lwm txoj hauv kev thiab nws cov txiaj ntsig ntawm kev sib raug zoo, ib puag ncig thiab nyiaj txiag poob. Kev xa khoom lossis kev lees txais ntawm qhov sib txawv yuav tsum tau sau ntawv tso cai los ntawm [lub luag haujlwm]; txwv tsis pub muab qhov hloov pauv hloov lossis ua kom tiav qhov kev pom zoo kho thiab rov kuaj dua. Deviation log thiab tso cov ntaub ntawv

Qauv RFQ extract: sab nraum zoov pre-connectorized davhlau ya nyob twg ntawm txoj kev dav hlau

Cov extract siv cov txiaj ntsig luam tawm los ntawm Lub Hwj ChimGL-FTB-10E FAT davhlau ya nyob twgthiab covSticklok davhlau ya nyob twg platformua piv txwv inputs. Cov no yog cov tswv yim sib tw, tsis yog cov ntaub ntawv pov thawj uas tau lees paub los yog kev lees paub ua tiav. Tus neeg yuav khoom thawj zaug xyuas lawv tawm tsam qhov kev pom zoo tsim; tus neeg muag khoom mam li lees paub txhua kab rau kev txiav txim teeb tsa nrog daim ntawv tshaj tawm.

Qauv RFQ extract rau lub dav hlau sab nraum zoov ua ntej txuas lub davhlau ya nyob twg, siv cov khoom lag luam luam tawm Hwjchim ci ntsa iab raws li cov neeg sib tw nkag

 

Teb Piv txwv nkag
Daim ntawv thov Aerial FTTH faib ntawm ntawm ODN passive; OLT optics chav kawm [__]; wavelengths [__]
Terminal 10 hardened adapter ports ntawm lub tsev nyob, siv tau yam tsis tau qhib lub thawv; 4F splice cassette; splitter tais rau 1 × 2 ntxiv rau 1 × 8
Port poob Tsawg dua los yog sib npaug rau 0.2 dB ib qhov chaw nres nkoj adapter ntawm 1310 thiab 1550 nm (GL-FTB-10E tus nqi luam tawm); poob ntawm splitter thiab splices qhia cais
Rov qab poob APC Ntau dua lossis sib npaug rau 60 dB
Ingress tiv thaiv Tsev IP65 thiab adapter foob IP67 raws li luam tawm; Tus neeg muag khoom hais txog lub xeev xeem thiab tshaj tawm tawm tsam IEC 60529
Poob kev sib dhos 4 × 7 mm ca drop cable, G.657.A1, hardened-to-SC/APC, siab tshaj IL 0.4 dB, 600 N rau 2 feeb (Sticklok luam tawm tus nqi rau qhov profile no); tus neeg muag khoom lees paub qhov profile tshwj xeeb connector code
Interface Hardened interface tsev neeg [__]; converter rau [__] tau lees paub los ntawm kev kos duab thiab qauv ua ntej xa khoom ntau
Daim ntawv lo Cim code rau ib lub thawv thiab ib lub cable, zoo ib yam ntawm ob lub connector kawg
Pov thawj Traceable Hoobkas cov txiaj ntsig rau cov khoom siv; Cov ntaub ntawv qhia txog kev tsim nyog suav nrog qhov tseeb configuration thiab cov clauses xav tau. Qhia qhov kev xeem ywj pheej lossis ntawv pov thawj qhov twg tus neeg yuav khoom txoj kev npaj tsim nyog xav tau.
Kuaj pob Ib-serial IL thiab RL nplooj ntawv, cov duab kawg ntsej muag thiab batch ID nrog txhua cov khoom xa tuaj

Tshawb xyuas cov lus teb ntawm tus neeg muag khoom: lees txais, qhia meej lossis tsis lees paub

Siv cov lus teb sau npe nrog ib kab ib qhov yuav tsum tau muaj: yam khoom thiab teeb tsa; cov ntaub ntawv thiab kab lus; yuav tsum tau txwv thiab txoj kev; muab tus nqi; qhia siv; sib txawv; tus saib xyuas; kev xav; hnub kaw. Cov kev cai hauv qab no yog cov neeg yuav khoom tswj hwm, tsis yog daim ntawv pov thawj. Ib daim ntawv teev npe ua haujlwm rau cov khoom sib piv ua ntej txuas yog nyob rau hauvMST Box RFQ Checklist: Ports, Connector, Stub Cable & Mounting.

Tus neeg muag khoom teb cov cai txiav txim siab rau RFQ cov lus teb rau npe

 

Tus neeg muab khoom teb Kev txiav txim siab Dab tsi kaw qhov khoom
Cov kev teeb tsa, kev sim thiab cov txiaj ntsig tau ua raws li qhov yuav tsum tau ua. Txais qhov yuav tsum tau muaj nyob rau theem tshuaj ntsuam xyuas. Sau cov ntaub ntawv qhia siv thiab tshuaj xyuas. Kev lees txais Kev Tsim Nyog tsis hloov cov khoom xa tuaj lossis qhov txuas-kev lees txais.
Tus nqi zoo li tsim nyog, tab sis daim ntawv tshaj tawm, ib tsab, tus qauv ntawm tus kheej lossis qhov kev kuaj mob ploj lawm. Tuav kom paub meej; kev sib haum xeeb tseem tsis tau pom. Tau txais cov ntaub ntawv pov thawj uas ploj lawm lossis qhov kev sim pom zoo ua ntej tso tawm. Ib daim ntawv qhia uas ploj lawm ib leeg tsis yog pov thawj ntawm lub cev tsis ua haujlwm.
Cov qauv muab los yog qhov tshwm sim txawv ntawm qhov tshwj xeeb. Txheeb xyuas qhov kev sib txawv uas tau tshaj tawm. Txoj cai tswj xyuas kev cuam tshuam, ib puag ncig thiab tag nrho cov peev nyiaj poob. Pom zoo tsuas yog qhov tso cai, cov ntaub ntawv hloov pauv; txwv tsis pub yuav tsum tau kho lossis tsis lees txais qhov kev thov cuam tshuam.
Ib qho kev xav tau uas tsis raug zam tsis ua tiav, cov peev nyiaj tau txais kev pom zoo dhau lawm, lossis qhov sib txawv tseem tsis tau daws. Tsis lees txais cov khoom cuam tshuam lossis txiav tawm. Yuav tsum tau ua raws li kev hloov pauv lossis kev pom zoo kho thiab rov kuaj dua. Sau qhov kev txiav txim zaum kawg thiab kev xa khoom xa tuaj lossis kev tso cai lees paub.

Kev tshuaj xyuas cov duab:Yog tias RFQ xav tau ib tus neeg IL txwv ntawm 0.30 dB rau ib lub rooj sib tham, tus neeg muag khoom qhov txhais tau tias ntawm 0.10 dB tsis pom qhov txwv. Qhov tshwm sim ntawm 0.42 dB rau ib lub rooj sib txoos hauv tib txoj kev ua tsis tau raws li tus neeg xav tau, txawm tias tus qauv txhais tau dhau los. Cov no yog cov kev ntsuam xyuas qhov tseem ceeb, tsis yog cov txiaj ntsig kev xeem lossis kev txwv ODN universal.

Tshaj tawm cov qauv hauv paus rau Tuam Tshoj-txheej txheem thiab export tej yaam num

Xaiv cov ntaub ntawv los ntawm cov khoom yuav khoom, kev teeb tsa kev teeb tsa thiab cov neeg yuav khoom xav tau. Lub hom phiaj teev ib feem ntawm cov ntsiab lus; peb cov tswv yim ua ke txhais cov kev qhia tshwj xeeb.

  • Suav teb."Rau txhua tus qauv, ceeb toom tawm tsam cov ntaub ntawv siv tau hauv lub sijhawm pom zoo: YD / T 6889.1-2026 rau cov thawv xa khoom, YD / T 6889.2-2026 rau cov thawv splitter, thiab YD / T 6954-2026 rau cable assemblies qhov twg saws. txheeb xyuas ib qho kev siv ua ntej ntawm Y208.T26. Cov peev txheej suav nrog kev lees txais cabling-system, txheeb xyuas cov cai tau txais los ntawm YD / T 7067-2026 Txuas cov ntaub ntawv pov thawj thiab tshaj tawm qhov sib txawv ntawm ib nqe lus.
  • Export."Ua tau raws li tus neeg yuav khoom tau teem caij kho vajtse, suav nrog cov lus pom zoo ETSI TS 104 021-1 cov lus rau [npe lub npe thiab cov xwm txheej ntawm kev teeb tsa]. Tshaj tawm cov ntaub ntawv pov thawj rau txhua qhov yuav tsum tau ua. Cov lus thov tsuas yog them cov nqe lus no tshwj tsis yog kev ua raws li tag nrho cov cai yuav tsum tau cais thiab ua qauv qhia. Qhia txog cov kev cai YD/T siv raws li kev yuav khoom los yog raws li kev tsim qauv. "
Kev nyeem keeb kwm: 2023 engineering kev sab laj kev tsim qauv

CovKev sib tham hauv tsab xov xwm ntawm digitized thiab preconnectorized ODN engineeringyog cov ntaub ntawv keeb kwm yav dhau. Phau ntawv qhia no tsis tau txais nws txoj kev-ntev, topology lossis kev npaj-poob cov nuj nqis raws li kev lees paub. Nws qhov kev tshaj tawm zaum kawg tseem tsis tau txiav txim siab ntawm no; siv qhov kev pom zoo tsim tsim thiab tau txais cov kev cai luam tawm rau kev yuav khoom.

Cov lus nug uas nquag nug

Q: Puas yog YD / T 6889.1-2026 thiab YD / T 6954-2026 yuav tsum tau nyob sab nraud Suav teb?

A: Tsis yog. Cov txheej txheem platform teev ob qho tib si raws li cov qauv kev lag luam pom zoo, thiab tsis yog kev cai thoob ntiaj teb. Cov neeg yuav khoom xa tawm tuaj yeem siv lawv raws li tus neeg muag khoom tsim cov ntaub ntawv pov thawj thiab nug cov qauv qhia tshwj xeeb rau txhua qhov kev thov ua raws.

Q: Thaum twg 2026 cov qauv kev txiav txim ua ntej yuav siv tau?

A: YD/T 6889.1-2026, YD/T 6954-2026 thiab YD/T 7067-2026 tau pib siv rau 1 Cuaj hlis 2026. YD/T 6889.2-2026 yuav siv sij hawm rau 1 Kaum ib hlis 2026 thiab tseem tsis tau muaj nyob rau hauv kev tshuaj xyuas hnub tim 10 lub 9 Hlis 2026.

Q: Qhov txawv ntawm YD / T 6889.1 thiab YD / T 6889.2 yog dab tsi?

A: Ntu 1 npog cov thawv ntim khoom sab nraum zoov ua ntej txiav tawm (光缆分纤箱). Ntu 2 npog cov thawv ua ntej txiav tawm lub davhlau ya nyob twg (分光终端盒). Ob leeg hais txog kev tsim, tsim khoom thiab tshuaj xyuas hauv ODN.

Q: Yuav ua li cas poob poob ETSI TR 103 775 muab rau cov cables ua ntej txuas?

A: Rau ib leeg-core cables nws muab IL Tsawg dua los yog sib npaug rau 0.3 dB nrog qhov nruab nrab ntawm Tsawg dua lossis sib npaug rau 0.1 dB, thiab rau cov tub ntxhais cov tub ntxhais feeder cables IL Tsawg dua lossis sib npaug rau 0.35 dB. Rau randomly mated ib leeg-core connectors nws muab ib tug txhais tau tias tsawg dua los yog sib npaug rau 0.12 dB thiab yuav tsum muaj tsawg kawg yog 97% ntawm kev sib txuas yuav tsum tsawg tshaj li los yog sib npaug rau 0.25 dB. Qhov feem pua ​​​​kev ntsuas tsis yog qhov txwv siab tshaj plaws rau txhua qhov kev sib txuas. Txais yuav cov kev xeem uas cuam tshuam thiab txheeb xyuas cov qauv qhia meej, thiab qhia txog kev txwv kev xa khoom ntawm tus kheej.

Q: Puas yog IP68 ntawm daim ntawv pov thawj txaus?

A: Nws nyob ntawm seb lub caij twg yog qhov ntsuas thiab nyob rau hauv lub xeev twg. Rau cov khoom nyob rau hauv nws cov peev txheej, ETSI TS 104 021-1 qhia txog IPx5 rau nyiaj siv ua haujlwm thiab IPx8 rau kev siv hauv av. Kev ua raws li cov txheej txheem tag nrho hu rau cov pov thawj tawm tsam txhua qhov yuav tsum tau ua, thiab ib qho kev ntsuam xyuas nkag teb nws cov lus. Nug tus neeg muag khoom rau lub npe ntawm cov khoom ntsuas, lub xeev xeem (capped, mated, nrog cable) thiab daim ntawv qhia uas qhia nws.

Q: Ib tus tsim lub davhlau ya nyob twg puas tuaj yeem lees txais lwm tus neeg tsim khoom poob cable?

A: Tsuas yog thaum tsev neeg interface thiab lub converter tau lees paub rau cov qauv tseeb. Glory's Sticklok nplooj ntawv teev cov kev xaiv hloov pauv rau Sticklok, OptiTAP, Huawei thiab ZTE interface cov tsev neeg thiab hais tias kev sib raug zoo yog cov qauv tshwj xeeb thiab yuav tsum tau lees paub nrog cov duab kos thiab cov qauv ua ntej xa tawm ntau.

Cov kauj ruam tom ntej: xa qhov project inputs

Xa koj qhov project lag luam, davhlau ya nyob twg interface, suav chaw nres nkoj, cable profile thiab kev lees paub yuav tsum tau ua. Lub hwjchim ci ntsa iab rov qab cov qauv neeg sib tw thiab cov ntawv teev npe uas mus nrog lawv.

GL-FTB-10E FAT pre-connectorized terminal box

GL-FTB-10E FAT davhlau ya nyob twg

10 waterproof adapter ports, 4F splice cassette, splitter tais, IP65 vaj tse.

Saib cov khoom

Sticklok tool-free locking FTTH terminal

Sticklok davhlau ya nyob twg platform

Ceg, splitter thiab TAP versions nrog cable-profile-specific connector sib dhos.

Saib cov khoom

 

 

 

 

 

 

FTTH ODN daws

Feeder, faib, nkag mus thiab cov neeg siv khoom kho vajtse npaj ua ib qho BOM nrog cov ntaub ntawv pov thawj.

Saib kev daws teeb meem

Qhov chaw

Xa kev nug