Txoj cai kev yuav khoom yog:
Qhov no muaj kev tiv thaiv ntau dua li kev pom zoo rau cable vim nws cov ntaub ntawv hais tias tsuas yog "G.657.A2," "sab nraum zoov," "armoured," lossis "IEC raws."
Cov ntsiab lus
- Corrigendum 1 hloov dab tsi
- Vim li cas G.657.A2 tsis tiav ib leeg
- Plaub cov ntaub ntawv pov thawj qhov tsis sib xws
- Ua pov thawj rau txoj kev
- Sau ib nqe lus-npaj RFQ
- Kev ua tom qab Cor.1 pom zoo
Dab tsi L.105 Corrigendum 1 Hloov-thiab Nws Tsis Yog
Corrigendum 1 rov kho cov lus piav qhia uas tsis tau tso tseg hauv 2025 hloov kho ntawm ITU-T L.105. Kev tshawb xyuas nyob rau 1 Cuaj Hlis 2026 pom tias covITU nplooj ntawv pom zoo rau L.105 Cor.1Cov ntaub ntawv pom zoo rau 10 Lub Xya Hli 2026, kev pom zoo rau 29 Lub Yim Hli 2026 thiab xwm txheej A (pom zoo).AAP tshaj tawm No. 43tau tshaj tawm rau lub Cuaj Hlis 1, 2026.
Tam sim noITU-T L.105 catalognpe L.105 (11/2025) raws li nyob rau hauv quab yuam thiab prepublished. Cor.1 cov ntsiab lus hais tias cov lus piav qhia uas ploj lawm yog:
- A.4.2 Kev laus;
- A.4.3 Longitudinal nkag mus rau dej;
- A.4.4 Moisture permeation; thiab
- A.4.6 Nas thiab kab puas tsuaj.
Tib lub ntsiab lus tseem ceeb muab txoj cai tswj hwm kev yuav khoom: kev teeb tsa kev teeb tsa sib txawv, yog li kev soj ntsuam ntxaws ntxaws yuav tsum tau pom zoo los ntawm tus neeg siv thiab tus neeg muag khoom rau ib puag ncig uas yuav siv cable.
Yog vim li cas G.657.A2 Tsis yog ib qho kev poob tag -Cable Specification
G.657.A2 txheeb xyuas qhov khoov -insensitive ib leeg- hom fiber ntau hom. Tiav lawm-kab kev tsim nyog cais npog lub tsho, cov tswv cuab lub zog, dej- thaiv qhov system, thaiv thaiv dej, hnav khaub ncaws thiab kev laus tus cwj pwm. Cov neeg yuav khoom yog li xav tau ob qhov kev sib txuas tshwj xeeb: ib qho rau cov fiber ntau thiab ib qho rau kev ua tiav cable.
Covtam sim no ITU-T G.657 Kev pom zootxhais khoov- poob-sensitive ib leeg- hom fiber ntau thiab cable yam ntxwv rau kev nkag mus rau hauv tes hauj lwm. Siv nws rau fiber ntau- cov kev xav tau ntawm pawg, tom qab ntawd daws cov kab hauv qab no- cov lus nug theem sib cais:
- Cov ntaub ntawv pov thawj puas tuaj yeem tiv taus txoj kev thermal thiab UV raug?
- Puas yog cov kua dej tso tseg ze ntawm lub tsho hauv zos ua txhaum cai, lossis nws puas tuaj yeem txav mus los ntawm txoj kab?
- Puas muaj qhov cuam tshuam txuas ntxiv qhov twg radial ya raws permeation yog qhov tsim kev pheej hmoo?
- Cov qauv twg hais txog cov nas uas raug txheeb xyuas los yog kab hem?
- Puas yog tus neeg muag khoom daim ntawv ntsuam xyuas rau qhov kev tsim kho tiag tiag?
Lub Glory Optical'sG.657.A1 piv rau G.657.A2 daim ntawv qhia kev yuav khoomnpog qhov twg ob pawg fiber ntau haum raws txoj kev FTTH. Khaws qhov kev txiav txim siab fiber ntau cais los ntawm ib puag ncig kev tsim nyog hais txog ntawm no.
| Kev tsim nyog txheej | Dab tsi nws tswj | Dab tsi nws tsis tuaj yeem ua pov thawj ib leeg |
|---|---|---|
| Fiber qeb, xws li G.657.A2 | Optical thiab macrobending yam ntxwv raws li tus qauv cov xwm txheej | Tiav lawm -cable dej, laus, sheath, tensile lossis nas ua haujlwm |
| Ua tiav -kev tsim kho kab | Jacket, lub zog, qhov ntev, kev thaiv, thaiv thiab kev txwv kev teeb tsa | Kev ua raws cai tshwj tsis yog cov ntaub ntawv pov thawj thiab cov txheej txheem raug muab |
| Txoj kev -cov pov thawj tshwj xeeb | Kev ua tau zoo raws li kev pom zoo ib puag ncig thiab kev sim tshuab | Kev teeb tsa tsis sib xws lossis cov khoom siv sib txawv ntawm cov cables |
Plaub Cov Ntaub Ntawv Pov Thawj Tsis Txaus Ntsig Los ntawm Kev Kho
Plaub lub ntsiab lus rov qab los tsim cov pov thawj muaj txiaj ntsig zoo: khaws cia lub neej, ua kua- dej tsiv teb tsaws, vapor permeation thiab kev puas tsuaj lom. Lawv muaj feem cuam tshuam, tab sis lawv tsis hloov pauv, thiab txhua tus yuav tsum coj mus rau cov lus nug sib txawv hauv kev yuav khoom tshwj xeeb.
1. Kev laus: thawj zaug attenuation tsis yog pov thawj ntawm lub neej
Thawj qhov kev kuaj pom pom pom tseeb tias lub cable ntawm ib qho taw qhia hauv lub sijhawm; Cov pov thawj kev laus tshawb xyuas seb cov khoom siv kho qhov muag lossis lub cev puas tseem siv tau tom qab tau hais tias siab - qhov kub thiab txias los yog caij tsheb kauj vab. RFQ yuav tsum yog li ntawd txhais tau hais tias ob qho tib si raug thiab qhov tso cai tshaj tawm - sim hloov.
IEC 60794-1-209: 2024 Kev Ua Haujlwmtxhais txoj kev laus F9 rau optical cables. IEC hais tias txoj kev siv siab - qhov kub thiab txias ntawm lub voj voog mus rau simulate lub neej tus cwj pwm ntawm attenuation los yog lub cev yam ntxwv. Nws kuj tseem sau txog qhov tseem ceeb ntawm 2024 kev kho dua tshiab: universal siab tshaj plaws attenuation-nce qhov tseem ceeb raug tshem tawm thiab muab tso rau hauv cov ntsiab lus kom tau teev tseg.
Qhov kev hloov ntawd txhawb nqa L.105 kev xav txog kev yuav khoom. "Tested rau F9" yog tsis tiav tshwj tsis yog cov ntaub ntawv yuav khoom kuj qhia, raws li muaj feem xyuam:
- cable qauv thiab preconditioning;
- raug kub, ncua sij hawm thiab lub voj voog ib ntus;
- ntsuas wavelengths thiab sijhawm;
- kuaj pom lossis cov khoom siv; thiab
- qhov tso cai attenuation lossis hloov lub cev.
Tsis txhob luam ib qho kev txwv los ntawm ib tsev neeg cable tsis sib xws tsuas yog ua kom muaj qhov khoob xwb. Cov txheej txheem yuav tsum yog los ntawm cov khoom siv tshwj xeeb, tus qauv tus neeg teb xov tooj lossis cov ntaub ntawv tus neeg yuav khoom - daim ntawv cog lus tus neeg muag khoom.
2. Kev nkag mus rau dej ntev: tswj dej tom qab kev ua txhaum cai hauv zos
Longitudinal dej nkag mus rau cov dej ua kua txav mus rau hauv cov kab hauv kab tom qab dej mus txog qhov tseem ceeb. Cov txiaj ntsig tau lees paub yuav tsum qhia tias cov khoom siv gel, swellable daim kab xev, xov paj lossis lwm yam thaiv kev ua haujlwm li cas raws li qhov ntsuas tau teev tseg; ib lub tsho PE, armor lossis "waterproof" daim ntawv lo ib leeg tsis muaj qhov tshwm sim.
CovIEC 60794 (IEC 60794) -1-22 ib puag ncig-kev xeem sivmuaj cov dej F5 luam tawm- txoj kev nkag mus tom qab, thaum IEC tab tom hloov kho tus kheej txoj hauv kev rau cov ntaub ntawv tshwj xeeb.IEC 60794-1-2: 2021muab cov ntaub ntawv hla- cov qauv siv rau cov lej tshiab thiab yav dhau los.
Rau kev piav qhia txog kev nkag mus radial, longitudinal migration thiab kaw interfaces, saib Glory Optical'sfiber cable waterproofing qhia. Cov ntaub ntawv kev pom zoo yuav tsum tseem muaj cov ntaub ntawv pov thawj ntawm cov ntaub ntawv qhia tseeb, nrog rau cov qauv ntev, lub taub hau dej lossis lub siab, lub sijhawm, tso cai rau xau lossis tsiv teb tsaws, thiab kev tsim kho kom pom tseeb.
3. Moisture permeation: dej vapor yog ib txoj kev sib txawv
Moisture permeation txhawj xeeb txog cov dej vapor dhau radially los ntawm ib lub hnab los yog thaiv, qhov kev nkag mus ntev yog kev txhawj xeeb txog cov kua dej taug kev raws kab. Cov dej qhuav- thaiv cov xov paj tuaj yeem txwv kev txav mus los ntev tom qab kev sib cuag nrog dej. Ib tug nruam radial vapor barrier yog ib qho kev txiav txim siab tsim kho.
Tam sim no ITU L-series kev taw qhia rau lwm hom kev teeb tsa qhia txog qhov sib txawv no.ITU-T L.110 (11/2025)sib tham txog kev thaiv cov hlau txuas txuas ntxiv rau kev tiv thaiv cov dej noo thaum sib cais kho cov gel lossis cov ntaub ntawv swellable siv los txwv cov kua longitudinal - dej txav. Qhov no yog analogous L-series xeem logic, tsis yog cov ntawv kawg ntawm L.105 Cor.1.
| Lus nug | Longitudinal dej nkag | Moisture permeation |
|---|---|---|
| Nruab nrab | Cov dej ua kua | Dej vapor / noo noo |
| Txoj kev loj | Tom qab nkag mus rau cable interstices | Radially los ntawm sheath los yog barrier |
| Cov qauv tsim teb | Gel, SAP daim kab xev, xov paj, hmoov los yog kaw core | Nruam nws yog xim hlau lossis lwm yam kev txwv tsis pub ya raws |
| Cov ntaub ntawv pov thawj | Lub npe dej -txoj kev nkag mus, kev teeb tsa, lub sijhawm thiab kev xau / kev tsiv teb tsaws | Kev tsim kho barrier thiab cov txheej txheem permeation / txheej txheem |
Tus neeg yuav khoom yuav tsum tsis txhob thov ib txheej hlau los ntawm lub neej ntawd. Nws yuav ntxiv txoj kab uas hla, nruj, hauv av lossis kev xav txog corrosion. Ua ntej txhim kho seb txoj kev puas muaj cov dej noo -permeation yuav tsum tau, tom qab ntawd sib piv cov qauv tsim ua tiav - tawm.
4. Cov nas thiab kab puas tsuaj: txhais cov pov thawj kev hem thawj thiab kev tiv thaiv
Qhia cov nas thiab kab tiv thaiv los ntawm tus qauv kev hem thawj. Cov ntawv sau dav dav xws li "armoured," "nas resistant" lossis "ntsia hauv duct" tsis qhia txog qib ntsuas thoob ntiaj teb. Cov pob ntawv pom zoo yuav tsum qhia txog kev tiv thaiv kev tiv thaiv, cov ntsiab lus nkag mus rau cable, kev lag luam kev lag luam - tawm thiab cov pov thawj pom zoo.
Tam sim no ITU cable kev taw qhia rau ncaj qha - faus thiab aerial daim ntaub ntawv kho nas tiv thaiv raws li kev teeb tsa- nyob ntawm. Piv txwv li,ITU-T L.101thiabITU-T L.102tuaj yeem pab cov neeg yuav khoom nkag siab qhov dav L-series mus kom ze, tab sis lawv yuav tsum tsis txhob siv los hloov cov lus kawg L.105 Corrigendum.
Nug plaub nqe lus nug ua ntej xaiv qhov kev tsim kho:
- Puas yog kev hem thawj rau nas, kab, noog lossis kev puas tsuaj rau txhua yam?
- Puas yog cable aerial, nthuav tawm ntawm lub façade, hauv cov kav dej, hauv qhov tuav lossis ncaj qha faus?
- Cov qauv twg yog npaj rau- iav xov, GRP cov ntsiab lus, corrugated hlau, hlau armour, conduit los yog ib tug ua ke system?
- Qhov kev sim, kev sib piv lossis qhov project-kev pom zoo tshwj xeeb txhawb kev tiv thaiv?
Ib yam khoom xws li Glory Optical'sROC poob cabletej zaum yuav yog tus neeg sib tw rau ib ntu sab nraum zoov tom qab nws tsim, rub txoj kev thiab cov ntaub ntawv pov thawj raug tshuaj xyuas. Qhov txuas yog ib qho kev xaiv khoom, tsis yog ib qho kev thov tias cov khoom tau lees paub rau L.105 Cor.1.
Muab cov ntaub ntawv pov thawj rau ntawm Txoj Kev
Txoj kev teeb tsa txiav txim siab seb qhov kev pheej hmoo yuav tsum muaj pov thawj; tsis muaj ib qho "sab nraum zoov poob cable" specification haum rau txhua qhov dav hlau, kav dej, faus thiab sab hauv tsev - ntu kev hloov pauv. Qhov twg ib lub cable hla ntawm sab nraum zoov mus rau sab hauv tsev NID lossis ONT txoj kev, nws yuav tsum tsim nyog rau ob qho tib si ib puag ncig thiab rau kev hloov pauv raws li cov cai hauv zos.
Cor.1 cov ntsiab lus tshwj xeeb sau tseg tias NID sab hauv tsev tuaj yeem ua rau cov xaim xaim xaim mus rau qhov chaw sab nraum zoov thiab sab hauv tsev. Qhov ntawd ua rau lub tsev nkag mus rau tus ciam teb tsim, tsis yog kev hloov pauv ntawm cov xim kos duab.
| Txoj kev ntu | Lub ntsiab lus tshuaj xyuas | Cov ntaub ntawv pov thawj thov |
|---|---|---|
| Tiv thaiv sab hauv tsev poob | Cov kev cai hluav taws kub hauv zos / haus luam yeeb, khoov thiab tuav, txiav geometry | Kev tshaj tawm lub tsho, cov ntaub ntawv pov thawj hluav taws uas siv tau, ua tiav - cable khoov thiab tensile txwv, batch kho qhov muag tau |
| Sab nraum zoov- mus rau- sab hauv tsev hloov pauv | UV / huab cua raug sab nraud; siv cov khoom siv sab hauv tsev / hluav taws kub hauv tsev; sealing ntawm nkag | Pom zoo dual-kev tsim kho ib puag ncig lossis lub ntsiab lus hloov pauv, muaj feem xyuam rau ib puag ncig / hluav taws pov thawj, teeb duab kos duab |
| Aerial lossis façade poob | Kub, UV, cua / dej khov qhov cuam tshuam, ncua / nro, clamps, tsiaj raug | Cable/clamp compatibility, tensile thiab kub pov thawj, UV yuav tsum tau, txoj kev - tshwj xeeb tsiaj tiv thaiv qhov twg xav tau |
| Underground duct / handhole | Cov kav dej yuav dej nyab; rub, crushing, nkag cov ntsaws ruaj ruaj thiab nas nyob twj ywm ua tau | Longitudinal ntsuas dej, rub / tsoo txwv, sib haum xeeb ntau yam, tiv thaiv nas yog qhov kev ntsuas kev hem thawj xav tau nws |
| Direct - faus ntu | Cov av ntub dej, cuam tshuam, tsoo, khawb, nas, corrosion thiab kho nyuaj | Lub hom phiaj-tsim ncaj qha- kev tsim kho faus, dej / dej pov thawj, kev tshuaj xyuas armour/corrosion thiab pom zoo tiv thaiv kab mob |
Siv covGlory Optical FTTH cable ntau yamlos sib piv cov qauv muaj tsuas yog tom qab tsim cov kev cai ntawm txoj kev. Rau cov haujlwm uas tseem xav tau terminals, splitters, kaw thiab cov neeg siv khoom tawm, covFTTH ODN network daws teeb meemmuab cov txheej txheem - theem ntsiab lus rau kev sib txuam cable nkag thiab cov seem ntawm txoj kev passive.
Sau ib nqe lus-Ready FTTH Drop Cable RFQ
Ib qho kev tsocai-npaj RFQ hloov txhua daim ntawv lo rau hauv ib cheeb tsam uas muaj pov thawj: cov qauv qauv, cov qauv xeem, qauv, txias, ntsuas, kev lees paub, qhia txog tus kheej thiab traceability. Qhov no ua rau cov neeg muab khoom sib piv muaj txiaj ntsig thiab tiv thaiv kev tshaj tawm rau ib qho kev siv cable los ntawm kev siv kom tsim nyog rau lwm tus.
| Cov lus tsis muaj zog | Quote-yuav tsum tau npaj |
|---|---|
| G.657.A2 FTTH cable | Qhia cov G.657 fiber ntau tam sim no ntxiv rau cov kab kos ua tiav, qhov ntev, qhov siab ntev, lub tsho, cov tswv cuab lub zog, thaiv / thaiv thiab ua tiav -kab txwv. |
| "Sab nraum zoov thiab tsis muaj dej" | Txhais lub dav hlau, façade, duct, handhole los yog faus ib puag ncig; npe cov dej uas xav tau ntev thiab/lossis cov dej noo- pov thawj permeation nyias. |
| "IEC ua raws" | Lub npe IEC tus qauv, xyoo, txoj kev, xeem cov xwm txheej thiab kev lees paub muaj feem xyuam rau cov kab lus hais. |
| "Kev laus dhau" | Lub xeev raug / lub voj voog cov xwm txheej, wavelengths, ntsuas lub sijhawm, tso cai hloov pauv thiab txais lub cev tom qab kuaj. |
| "Armoured thiab nas pov thawj" | Txheeb xyuas qhov kev hem thawj thiab txoj hauv kev, cov qauv kev tiv thaiv, kev sim / kev pom zoo thiab cov kev cai hauv av / corrosion. |
| "Test report include" | Yuav tsum tau tshaj tawm xov tooj / hnub tim, kuaj tus kheej, qauv qauv / kos duab / BOM kho, tsim qhov chaw uas cuam tshuam, tshwm sim thiab siv tau / hloov kho. |
| "Same as sample" | Txuag ib qho kev pom zoo kos duab thiab cov khoom siv / BOM kho; txhais cov ntawv ceeb toom hloov pauv thiab kev tsim nyog tau txais txiaj ntsig. |
| "Batch kuaj" | Txheeb xyuas seb qhov kev ntsuam xyuas niaj hnub ua tau li cas rau ib lub reel lossis ntau, qauv qauv, txwv kev lees paub thiab cov kab rov qab / ntau qhov traceability. |
Cov ntaub ntawv pov thawj yuav tsum teb peb cov lus nug tso tawm:
- Kev siv tau:Puas yog tus qauv thiab txoj kev siv rau qhov kev teeb tsa thiab hom kab no?
- Tus kheej:Puas yog qhov kuaj kab mob zoo ib yam li cov qauv thiab kev tsim kho?
- Txais:Puas yog cov xwm txheej thiab dhau / tsis ua tiav cov txheej txheem sau hauv daim ntawv cog lus yuav?
Rau kev tsim kho, Glory Optical'sOEM / ODM kev xaivdaim ntawv teev txoj kev ib puag ncig, hom fiber ntau, lub tsho, lub zog cov tswv cuab, ntev thiab kos npe raws li thaj chaw configurable. Ntxiv cov ntaub ntawv xeem uas xav tau thiab cov ntaub ntawv taug qab mus rau qhov kev teeb tsa ua ntej kev pom zoo ua qauv. Thaum cov txheej txheem matrix thiab cov ntaub ntawv pov thawj npaj txhij, xa lawv nrog rauthov kom haises tsis yog thov rau ib tug generic "L.105 cable."
Cov neeg yuav khoom yuav tsum ua li cas tom qab pom zoo Cor.1
Kev pom zoo Cor.1 yuav tsum ua rau muaj kev tshuaj xyuas ntawm cov khoom poob tam sim no -cov kab lus tshwj xeeb thiab cov ntaub ntawv pov thawj. Txoj haujlwm tam sim no yog daim ntawv qhia kev pom zoo kho rau txoj hauv kev tiag tiag, txheeb xyuas cov pov thawj muaj feem cuam tshuam thiab hloov kho tus neeg yuav khoom- daim ntawv cog lus tus neeg muag khoom yam tsis muaj kev hloov pauv tag nrho plaub lub ntsiab lus rau hauv kev sim thoob ntiaj teb.
Siv tsab xov xwm no tsib -qhia kev siv cov kauj ruam:
- Txuag cov ntaub ntawv tswj kev teeb tsa.Cov ntaub ntawv L.105 (11/2025), daim ntawv pov thawj Corrigendum siv, hnub pom zoo thiab daim ntawv tswj tau siv rau RFQ.
- Sib piv cov kev kho nrog cov specification tam sim no.Txheeb xyuas seb puas muaj kev laus zuj zus, kev nkag mus rau hauv dej ntev ntev, kev ya raws kev ya raws thiab kev puas tsuaj rau nas / kab puas twb tau them, ib nrab los yog tsis tuaj.
- Segment txoj kev.Kos rau sab hauv tsev, kev hloov pauv, huab cua, kav dej, qhov tuav thiab ncaj qha - faus seem es tsis txhob siv ib daim ntawv lo rau tag nrho cov poob.
- Teem pov thawj ciam teb.Rau txhua qhov kev pheej hmoo, pom zoo cov qauv luam tawm, qauv, qauv, cov xwm txheej, kev ntsuas thiab kev lees paub. Sau qhov laj thawj qhov twg lub ntsiab lus tsis siv tau.
- Kaw tus kheej thiab hloov pauv - tswj qhov khoob.Muab txhua daim ntawv tshaj tawm rau cov qauv hais, kos duab thiab cov khoom siv / BOM kho; txheeb xyuas qhov kev tsim kho hloov ua rau kev tshuaj xyuas lossis rov kuaj dua.