Lub thaj vaj huam sib luag yog qhov feem ntau kov cov khoom tiv thaiv passive hauv txhua lub network fiber ntau. Tshaj li lub neej ua haujlwm ntawm lub chaw khaws ntaub ntawv lossis FTTH faib cov node, cov kws tshaj lij txuas, txiav tawm, ntxuav, daim ntawv lo, thiab rov ua cov hlua khi ntawm cov vaj huam sib luag ntau pua zaus.Txhua qhov kev txiav txim siab tsim koj ua ntawm kev teeb tsa - qhov ntom ntom, daim foos, MPO hom, cassette vs. tsau, labeling system - compounds over every one of the touches.
Kab lus no tsis piav txog thaj vaj huam sib luag feem ntau. Nws piav qhia txog cov kev ua tsis tiav tshwj xeeb uas tshwm sim hauv kev xa tawm tiag tiag, vim li cas lawv thiaj li kwv yees los ntawm qhov kev txiav txim siab tsim qauv, thiab dab tsi engineering txwv tswj kev lag luam. Ob lub ntsiab lus xa tawm peb tshuaj xyuas yog cov ntaub ntawv chaw txha nraub qaum- nplooj ntaub ntawm 400–1000 chaw nres nkoj ntom ntom, thiab FTTH ODF ntawm 5,000- cov neeg siv khoom faib cov node - vim tias lawv sawv cev rau qhov sib txawv ntawm qhov teeb meem tib yam: tswj kev sib txuas fiber ntau ntawm qhov ntsuas, nyob rau hauv ib puag ncig ntawm kev saib xyuas.
Qhov Kev Txiav Txim Siab: Vim Li Cas Koj Tsis tuaj yeem "mus Siab"
Kev lag luam fiber ntau tau hloov mus rau qhov chaw nres nkoj siab dua rau 20 xyoo . 1U panels tau txav los ntawm 12 chaw nres nkoj mus rau 24 mus rau 48 mus rau 96 LC duplex. High-ntaus MPO cassette thav duab tam sim no ua tiav 144 txog 288 LC sib npaug sib txuas hauv 1U. Kev lag luam pitch yog ncaj nraim: ntau qhov chaw nres nkoj ib chav tsev rack txo hneev taw, txo tag nrho qhov chaw khib nyiab, txo tus nqi ib qho chaw nres nkoj.
Qhov teeb meem no tshem tawm yog qhov tshwm sim ntawm kev ua haujlwm. Hauv 48-chaw nres nkoj 1U LC duplex vaj huam sib luag, txhua qhov txuas tuaj yeem siv tau nrog kev ncaj, txhais tes ncaj qha. Tus kws tshaj lij nrhiav qhov chaw nres nkoj, ntxuav lub ferrule, ntxig rau txoj hlua, thiab txav mus. Hauv 96-chaw nres nkoj lossis 144-chaw nres nkoj ultra-high-density vaj huam sib luag, lub cev geometry hloov pauv: cov chaw nres nkoj ze dua ua ke, qee qhov xav tau cov khoom sib txuas lossis cov cuab yeej pabcuam, thiab rub ib lub qaum rau hauv lub vaj huam sib luag uas muaj neeg nyob sib ze txav cov hlua nyob sib ze.Tus nqi tiag tiag ntawm siab - ntom ntom panels tsis yog lub vaj huam sib luag nws tus kheej. Nws yog kev ua haujlwm rau ib qhov chaw nres nkoj- kov ntawm lub vaj huam sib luag lub neej ua haujlwm.
Panels rated above 48 LC duplex per 1U (i.e., >2.0 ports/cm ntawm vaj huam sib luag dav) yuav luag universally xav tau ib co hom ntawm angled los yog thawb-rub LC connector kom ua tau huv si nyob rau hauv ib tug tag nrho cov pejxeem. Angled connectors nce ib - connector nqi los ntawm 30–60% thiab tsim labeling teeb meem uas compound lub sij hawm. Qhia qhov no rau hauv tag nrho cov nqi ntawm cov tswv cuab ua ntej cog lus rau ultra- siab- qhov ceev thaum pib qhov khoom.
Kuj tseem muaj kev xav txog airflow uas feem ntau tsis tuaj ntawm thaj chaw sib tham txog kev yuav khoom. Fiber optic panels lawv tus kheej tsim tsis muaj cua sov, tab sis nyob rau hauv siab - ib puag ncig ceev, cable bundles tom qab panels tsim tsis kam rau airflow. Lub vaj huam sib luag muaj 2U siab- ntom ntom ntom ntom ntom nrog 144 qhov chaw nres nkoj tuaj yeem khaws cov kab txuas hauv qhov tob ntawm 80-120mm nyob rau tom qab, uas, nyob rau pem hauv ntej- mus rau- rov qab airflow architecture, tsim cov airflow tseem ceeb rau cov khoom siv nyob rau hauv qhov chaw khib nyiab.
Qhov tseeb engineering ncej yog:Dab tsi yog qhov ntom ntom uas tsim nyog rau txoj haujlwm khib nyiab tshwj xeeb, muab qhov kev xav tau ntawm kev ua haujlwm cadence (yuav ua li cas feem ntau cov chaw nres nkoj yuav txav mus los), cov kev tswj xyuas cable qhov tob muaj, thiab kev tu cov kev txwv ntawm ib puag ncig?Ultra-high density yog cov lus teb zoo rau sab saum toj passive- ntawm - khib ua ntej- lub cev txiav tawm uas tau kov ib zaug. Nws yog cov lus teb tsis ncaj ncees rau kev ua haujlwm - cheeb tsam vaj huam sib luag nrog MAC nquag (tsav, ntxiv, hloov).
Cassette-Based Systems: Lub Flexibility uas tsim cov ntsiab lus tsis ua tiav tshiab
Cassette-raws li (los yog "modular") thaj vaj huam sib luag tshuab tau dhau los ua tus qauv hauv siab -cov ntaub ntawv ceev ceev xa tawm. Cov qauv tsim yog yooj yim: 1U lossis 2U chassis lees txais cov khoom sib hloov pauv tau, txhua tus muaj ib qho ua ntej - txiav tawm fiber ntau array - feem ntau 12 LC duplex ports nyob rau pem hauv ntej thiab MPO -12 lossis MPO-24 connector nyob rau sab nraub qaum uas lees txais cov kab txuas ua ntej.
Qhov zoo ntawm installation yog tiag tiag. Cov khib nyiab ntawm cov kab ntawv xov xwm-raws li cov vaj huam sib luag tuaj yeem ua haujlwm tag nrho hauv ib feem ntawm lub sijhawm xav tau rau kev sib txuas lossis teb- cov kev daws teeb meem. MPO trunk cables txuas lub cassette rear mus rau qhov kawg tej thaj chaw deb - feem ntau yog lwm lub cassette, ib tug fiber ntau faib thav duab, los yog ib tug transceiver - uas tsis muaj teb splicing, tsis connectorization, thiab tsis muaj OTDR kuaj ntawm ib tug fibers thaum lub sij hawm installation.
Lub hom tsis ua hauj lwm kuj yog tiag tiag, thiab nws tshwm sim los ntawm tib yam ntxwv yam ntxwv uas tsim lub installation kom zoo dua.
Cov teeb meem kev sib kis
Txhua lub cassette module qhia ob lub ntsiab lus txuas ntxiv ntsig txog qhov ncaj qha -txuas kev daws teeb meem: MPO- mus rau -MPO kev sib txuas nyob rau tom qab ntawm lub chassis, thiab sab hauv txoj kev los ntawm MPO array mus rau LC ports ntawm lub ntsej muag pem hauv ntej. Nyob rau hauv ib tug raug cov ntaub ntawv center txuas, txoj kev yuav yog:
Txhua qhov txuas txuas txuas yog qhov kev pheej hmoo kis kab mob. IEC 61300-3-35 txhais qhov pass/fail threshold rau connector kawg-fim contamination ntawm 0.2 dB ntxiv insertion poob rau ib leeg-hom, tab sis kev kis kab mob tsis tshua muaj ua rau ib qho kev huv si tsis ua hauj lwm - nws accumulates maj mam, raws li particulates adhere rau lub ntsej muag possibilities nyob rau hauv ib feem, ferial kev huam yuaj thiab cov txheej txheem tu tsis txaus. Nyob rau hauv lub kaw lus kaw lus, lub MPO txuas tom qab feem ntau siv tsis tau yam tsis tau tshem lub cassette ntawm lub chassis.Cov connectors no yuav luag tsis tau ntxuav hauv qhov chaw ua haujlwmvim hais tias cov txheej txheem ntxuav yuav tsum tau ib nrab disassembly ntawm lub vaj huam sib luag sib dhos thiab tsis suav nrog hauv cov qauv ua ntej - teb cov txheej txheem daws teeb meem.
Nyob rau hauv siab -MAC ib puag ncig, feem ntau unexplained intermittent link degradation (link flapping, BER nce, transceiver Rx fais fab poob) nyob rau hauv cassette-raws li panels yog rear MPO connector contamination - tsis pom pem hauv ntej LC kev sib txuas uas cov kws kho mob huv si. Vim tias cov khoom sib txuas no tsis pom thiab tsis suav nrog hauv cov lus qhia ua haujlwm, feem ntau lawv tsis raug tshuaj xyuas kom txog thaum tag nrho lwm cov laj thawj raug txiav tawm. Lub sij hawm nruab nrab los txheeb xyuas hom kev ua tsis tiav no hauv thaj teb: 4-8 teev ntawm kev daws teeb meem ntawm qhov txuas cuam tshuam.
- Lub sij hawm txhim kho: 60–80% sai dua qhov chaw- xaus
- Tsis muaj OTDR rau -kev kuaj fiber ntau ntawm kev teeb tsa
- Modular reconfiguration: swap cassette hom yam tsis re-cabling trunk
- Factory- kuaj IL/RL ntawm txhua lub tshuab luam ntawv - kev ua tau zoo ib yam
- Txhawb B2B thiab Txoj Kev B MPO polarity hauv tib lub chassis
- 8 connector interfaces ib qhov txuas vs . 4 (kev pheej hmoo kis kab mob ob npaug)
- Tsheb MPO connectors nkag tsis tau yam tsis muaj ib nrab disassembly
- Siab dua rau -port IL: cassette feem ntau ntxiv 0.35–0.55 dB vs. tsau vaj huam sib luag
- Polarity yuam kev ntawm rear MPO multiplied hla tag nrho 12 pem hauv ntej LC ports
- Tus nqi siab dua: chassis + cassette + MPO lub cev vs. vaj huam sib luag + thaj qaum
MPO Polarity: Qhov Kev Ua Tsis Zoo Uas Ncua Nrog Koj Kev xa tawm
MPO polarity yog ib qho ntaub ntawv tshaj plaws ntawm kev xa tawm tsis ua haujlwm nyob rau hauv ua ntej - txiav cov fiber ntau, thiab nws tseem nkag siab tsis zoo hauv thaj chaw. Qhov teeb meem tseem ceeb: MPO connector muaj 12 los yog 24 fibers teem nyob rau hauv ib tug linear array. Kev xa tawm fiber ntau ntawm txoj hauj lwm 1 ntawm ib qho kawg ntawm qhov txuas yuav tsum tau txiav tawm ntawm qhov chaw nres nkoj txais ntawm txoj hauj lwm 1 (los yog txoj hauj lwm sib thooj) ntawm qhov kawg. Yog hais tias txoj kev polarity tsis tu ncua nyob rau hauv tag nrho cov txuas - trunk cables, cassettes, cassette orientation nyob rau hauv lub chassis - qhov tshwm sim yog ib qho Rx-rau-Rx kev twb kev txuas (tsis muaj teeb liab) los yog tus ntoo khaub lig- txuas mus txuas rau parallel channel.
TIA-568.3-D txhais peb txoj kev polarity: Txoj Kev A, Txoj Kev B, thiab Txoj Kev C. IEC 61754-7-1 muab lub cev MPO connector specification. Cov kev txwv tseem ceeb uas cov neeg ua haujlwm niaj hnub tsis pom zoo:Txoj kev polarity tsis yog cov cuab yeej ntawm ib feem. Nws yog ib qho cuab yeej ntawm tag nrho cov kab ke txuas.Ib Txoj Kev B lub cev cable ua ke nrog Txoj Kev A cassette ntawm ib qho kawg thiab Txoj Kev B cassette ntawm lwm qhov ua rau tsis raug polarity ntawm txhua khub fiber ntau. Qhov kev ua yuam kev no tsis tuaj yeem kho los ntawm kev hloov cov ntawv xov xwm - nws yuav tsum muaj kev rov ua dua tshiab - kev tshuaj xyuas ntawm txoj kev txuas tiav.
Cov txiaj ntsig tseem ceeb ntawm kev ua haujlwm: hauv 400- chaw nres nkoj MPO xa tawm nrog cov txheej txheem sib xyaw polarity, txheeb xyuas thiab kho qhov tsis raug polarity yuav tsum muaj kev taug qab ntawm txhua tus neeg txuas - cov txheej txheem uas, ntawm cov kws tshaj lij kev ua haujlwm zoo, yuav tsum siv 8-15 feeb rau ib qhov txuas. Ib qho 20% yuam kev thoob plaws 400 qhov txuas yields 80 txuas × 12 feeb=kwv yees li 16 tus neeg-teev ntawm kev ua haujlwm kho kom raug, tsis muaj cov khoom tsim tawm.
Kev tiv thaiv yog ncaj nraim tab sis yuav tsum tau ua ntej kev tsim qauv kev qhuab qhia: txhais cov txheej txheem polarity thaum pib ntawm txoj haujlwm, sau nws hauv cov ntaub ntawv cabling, qhia nws ntawm kev xaj xaj rau txhua qhov khoom (cov pob tw, cassettes, adapter phaj), thiab txheeb xyuas qhov polarity ua ntej lub vaj huam sib luag yog populated. Cov neeg ua haujlwm feem ntau uas tau tswj hwm MPO qhov kev daws teeb meem loj polarity project siv qhov yuav tsum tau tshuaj xyuas "polarity matrix" raws li lub rooj vag raug cai hauv lawv daim ntawv txheeb xyuas.
Thaum muab cov khoom siv los ntawm ntau tus neeg muag khoom rau MPO system, tau txais daim ntawv lees paub ntawm txoj kev polarity siv nyob rau hauv txhua hom khoom. Tsis txhob xav tias qhov sib xws ntawm cov npe lossis txawm tias hla cov khoom tsim los ntawm tib hom. Thaum Glory Optical muab MPO pob tw cables thiab cassettes ua ib qho system, tag nrho cov khoom yog lub Hoobkas - qhia rau ib txoj kev tshaj tawm polarity thiab sau npe raws li.
Kev poob nyiaj txiag: Vim li cas Koj Qhov Txuas Ua Haujlwm ntawm Kev Ua Haujlwm thiab Tsis Ua Haujlwm ntawm Xyoo 3
Kev siv nyiaj siv hluav taws xob kho qhov muag tau ua nyob rau theem tsim txuas. Rau ib tug raug 100G SR4 multimode txuas siv OM4 fiber ntau, cov peev nyiaj poob yog 3.0 dB (IEEE 802.3bm). Rau 10G LR ib zaug - hom txuas dhau OS2, cov peev nyiaj tau loj dua - 10.0 dB (IEEE 802.3ae) - uas ua rau muaj kev nkag siab tsis tseeb ntawm cov paj hauv lub sijhawm ntev - kev npaj.
Qhov teeb meem yog qhov poob accumulates nyob rau hauv lub sij hawm los ntawm mechanisms uas tsis pom ntawm commissioning:
Cov kab mob sib kis.Ib qho huv LC connector ntawm OM4 fiber ntau pab kwv yees li 0.1-0.2 dB qhov poob ntawm commissioning. Tom qab 12-18 lub hlis ntawm kev ua haujlwm nyob rau hauv ib puag ncig cov ntaub ntawv (plua plav, huab cua zoo, ib ntus tsis sib haum), kev sib kis tuaj yeem nce qhov no mus rau 0.4-0.8 dB. Hla 4- txuas txuas, qhov no sawv cev rau 0.8–2.4 dB ntawm qhov poob ntxiv - uas muaj peev xwm tshaj tag nrho cov npoo rau qhov txuas luv-mus txog multimode.
Connector hnav.IEC 61754-4 qhia txog LC connector mechanical durability ntawm 500 mating cycles yam tsawg kawg nkaus. High-turnover ports nyob rau hauv active thaj chaw yuav mus txog qhov kev txwv no nyob rau hauv 3-5 xyoo ntawm kev ua hauj lwm. Hnav ua rau nce qhov poob thiab rov qab poob degradation ib txhij.
Khoov vojvoog ua txhaum cai.Patch cord tswj nyob rau hauv siab - ntom ntom panels feem ntau tsim khoov radii hauv qab IEC 61300-3-1 yam tsawg kawg nkaus (feem ntau 30mm rau tus qauv ib hom, 7.5mm rau G.657A2 khoov-insensitive). Ib lub vojvoog khoov ib leeg ntawm OS2 fiber ntau tuaj yeem ua rau 0.3-1.0 dB ntawm kev poob ntxiv nyob ntawm qhov hnyav thiab qhov ntev. Vim tias qhov ua txhaum cai yog nyob rau hauv txoj kev teeb tsa cable es tsis yog ib qho txuas, nws tsis raug txheeb xyuas los ntawm kev tu tus qauv thiab rov kho qhov teeb meem.
Qhov cuam tshuam txog kev tsim vaj tsev: kev suav nyiaj poob pib yuav tsum suav nrog kev degradation reserve - yam tsawg kawg nkaus ntawm 0.5–1.0 dB tuav tseg rau kev cia siab 3- xyoo sib kis. Rau ntau hom kev sib txuas nrog cov peev nyiaj nruj (3.0 dB tag nrho), qhov kev cia no tsis tas yuav muaj yam tsis muaj kev txo qis mus txog. Rau ib qho - hom kev sib txuas nrog cov peev nyiaj dav dav (10 dB+), cov khoom cia muaj tab sis tsis tshua muaj kev faib tawm, uas ua rau pom qhov "tsis piav qhia" qhov txuas tsis ua tiav hauv xyoo 4-6 uas yog qhov kev kwv yees tau tshwm sim ntawm kev tsis quav ntsej txog kev poob mus ntev.
Cable Management Tom qab Vaj Huam Sib Luag: Qhov twg Installations tsis ua hauj lwm
Kev tswj xyuas lub cev ntawm cov hlua khi tom qab lub vaj huam sib luag fiber ntau yog qhov kev xav txog kev ua haujlwm feem ntau tsis saib xyuas thaum lub sijhawm tsim qauv, thiab ib qho yuav ua rau muaj teeb meem kev saib xyuas tsis tu ncua. Nyob rau hauv ib puag ncig cov ntaub ntawv, qhov no yog ib qho kev txwv tiag tiag: lub vaj huam sib luag uas muaj 2U vaj huam sib luag tuaj yeem muaj 144 LC duplex kev sib txuas, txhua tus nrog ib txoj hlua txuas tawm tom qab. Kev tswj kom raug thiab tswj 144 tus tib neeg txoj hlua khi hauv qhov chaw 1-2U, thaum tswj qhov qis kawg ntawm lub vojvoog khoov, siv tau daim ntawv lo, thiab muaj peev xwm taug qab thiab hloov ib tus neeg qaum yam tsis muaj kev cuam tshuam rau nws cov neeg nyob ze, yog ib qho teeb meem engineering.
Cov qauv kev tsis ua haujlwm feem ntau pom hauv thaj chaw:
Cord bunching ntawm cov ces kaum nkag.Thaum patch cords tawm tom qab ntawm lub vaj huam sib luag nyob rau hauv ib lub nras thiab raug xa mus los ntawm ib tug cable tswj caj npab los yog kab rov tav tus neeg saib xyuas, cov hlua sab nraud ntawm lub nras khoov ntau dua li cov hlua sab hauv. Hauv 144-chaw nres nkoj vaj huam sib luag, cov hlua sab nraud hauv 15- qaum qaum yuav ncav cuag qhov khoov radii ntawm 15–20mm - qis dua 30mm yam tsawg kawg nkaus rau tus qauv OS2 ib hom. Cov hlua sab hauv yog raug cai; cov sab nrauv yog nyob rau hauv kev khoov khoov ntev. Txij li thaum tsis muaj qhov qhia tau yooj yim pom ntawm qhov kev ua txhaum cai no, nws tseem nyob mus ib txhis.
Label obscuration.Cov kab ntawv siv rau ntawm thaj chaw qaum ntawm lub vaj huam sib luag kawg yog obscured los ntawm cov ntaub ntawv cable nyob rau hauv lub lis piam ntawm lub vaj huam sib luag yog tag nrho cov neeg. Qhov no yuam cov kws tshaj lij txhawm rau taug qab cov hlua ib tus neeg los ntawm kev ua raws lawv mus rau lwm qhov kawg - ib zaug - siv cov txheej txheem uas nws tus kheej txaus ntshai cuam tshuam cov hlua uas nyob ib sab. Hauv siab -MAC ib puag ncig, qhov no ua rau kev txheeb xyuas kab tsis raug thiab ua rau mis- tsis sib xws, uas tuaj yeem ua rau muaj kev pabcuam tsis raug.
Vaj huam sib luag strain tsub zuj zuj.Patch cords uas tsis txaus siab nyob rau hauv 150 hli ntawm lawv lub vaj huam sib luag connector (ib TIA-569-D cov lus pom zoo rau fiber ntau cabling kev pab cuam lub sij hawm) tsim ib tug nruam lateral strain ntawm LC los yog SC connector lub cev. Sij hawm dhau mus, qhov no degrades cov mating kev sib cuag ntawm lub connector ferrule thiab lub vaj huam sib luag adapter, ua rau poob poob. Qhov no yog teeb meem tshwj xeeb rau kab rov tav panels qhov twg lub ntiajteb txawj nqus ua perpendicular mus rau connector axis.
Npaj rau qhov tsawg kawg nkaus 150mm ntawm cable tswj qhov tob tom qab ib lub vaj huam sib luag nrog ntau tshaj 48 qhov chaw nres nkoj, thiab 200mm rau panels saum 96 chaw nres nkoj. Siv 1U kab rov tav tus thawj tswj hwm (lub vojvoog- txwv hom, tsis yog D -rings) ntawm txhua lub vaj huam sib luag. Rau kev tswj cov kab ntsug ntsug, siv lub vojvoog cable nrog lub vojvoog- txwv cov kev taw qhia ntawm cov ntsiab lus nkag thiab tawm. Tsis txhob siv cov hlua khi ntawm cov hlua fiber ntau cov hlua khi - siv nuv-thiab- hlua hlua ntawm qhov siab tshaj plaws ntawm 0.1 N·m (ntiv tes- nruj).
FTTH ODF Cov Ntsiab Lus: Txawv Scale, Tib Hom Kev Ua Tsis Zoo
Lub fiber faib thav duab (FDF) los yog kho qhov muag tis ncej (ODF) nyob rau hauv ib tug FTTH ODN ib puag ncig yog structurally analogous mus rau ib tug data center thaj vaj huam sib luag, tab sis lub teev thiab kev ua hauj lwm txwv txawv heev. Ntawm 5,000-cov neeg siv khoom faib tawm, lub chaw ua haujlwm hauv nruab nrab ODF tuaj yeem txiav tawm 500–2,000 fibers los ntawm cov txheej txheej pub khoom noj, taug kev los ntawm ntau lub PLC splitters (feem ntau 1:32 lossis 1:64 hauv ob-theem faib cov qauv), thiab faib rau cov neeg siv khoom xa tuaj.
Qhov kev ua haujlwm tseem ceeb sib txawv los ntawm cov ntaub ntawv chaw nruab nrab: FTTH ODFs tau nkag mus tsis tshua muaj rau cov neeg siv khoom tab sis siv zog thaum lub sijhawm ua txhaum cai - thaum qhov kev sib txuas tsis ua haujlwm, lossis cov xaim xaim raug puas, ntau cov kev pabcuam raug cuam tshuam ib txhij, thiab ODF dhau los ua qhov sib koom ua ke rau kev kho cov haujlwm. Nyob rau hauv ib puag ncig no, kev sib kis kab mob sib kis thiab cov ntawv sau tsis raug muaj kev sib raug zoo ncaj qha rau lub sijhawm kho (MTTR) rau kev kho cov neeg siv khoom.
Qhov kev sib tw ua haujlwm hauv FTTH ODF yog qhov kev siv nyiaj poob qis yog siv los ntawm PLC splitter theem (~ 10.5 dB rau 1: 8 ib theem). Lub ODF connector pab, thaum tshwm sim me me (0.5-1.0 dB tag nrho ntawm commissioning), siv ib tug disproportionate feem ntawm cov muaj, vim hais tias lub splitter poob yog tsau thiab tsis tuaj yeem txo. Txhua qhov kev sib kis- ua rau muaj kev nce ntxiv ntawm ODF theem ncaj qha rho tawm los ntawm cov neeg siv khoom tau txais cov nyiaj tau los.
Qhov no ua rau FTTH ODF connector txij nkawm ua haujlwm tseem ceeb dua hauv cov ntaub ntawv chaw siv feem ntau - ib qho kev sib kis SC/APC connector ntawm ODF yuav degrade 8 mus rau 64 cov kev pab cuam ib txhij, nyob ntawm qhov sib faib theem theem uas nws tshwm sim.
LC Duplex vs. MPO: Qhov Kev Txiav Txim Migration Koj Tsis Tau Rov Qab
Hauv cov ntaub ntawv chaw ib puag ncig, kev hloov pauv ntawm 10G mus rau 100G, thiab kev cia siab tias yuav hloov mus rau 400G, tau yuam cov lus nug uas cov koom haum feem ntau cuam tshuam:Thaum twg lub thaj vaj huam sib luag yuav tsum cog lus rau MPO qaum?
Cov lus nug tsis yog tsuas yog hais txog bandwidth tam sim no. MPO-raws li kev tsim kho vaj tse, ib zaug ntsia raws li tus txha caj qaum, nws nyuaj rau txuas ntxiv siv tus qauv ib zaug -fiber LC-raws li kev sib txuas vim nws yuav tsum muaj LC breakout cassettes (uas ntxiv cov suav txuas thiab cov kev pheej hmoo sib kis tau piav qhia hauv Tshooj 02) lossis tag nrho MPO connectorization ntawm ob qho kawg ntawm txhua qhov txuas. Hloov pauv, LC duplex caj qaum, txuas ntxiv los txhawb 100G lossis 400G parallel optics, yuav tsum yog:
- → Parallel ib leeg -mode breakout cables(8-fiber lossis 4-fiber bundles ib 100G lossis 25G txoj kab) - ua tiav cov qauv sib luag yam tsis muaj MPO, tab sis ntawm tus nqi siab ntawm qhov chaw nres nkoj thiab kev tswj hwm cable tsis yooj yim ntawm qhov ntsuas.
- → Tag nrho kev tsiv teb tsaws mus rau MPO qaum- yuav tsum tau recabling los yog overlaying ib tug parallel MPO infrastructure, uas nyob rau ntawm 400+ chaw nres nkoj nplai muaj peev xwm loj thiab nqi zog, thiab lub sij hawm ua hauj lwm uas ob qho tib si infrastructures coexist, nce complexity.
- → BiDi (bidirectional) optics ntawm ib leeg -fiber LC- ua tiav 40G lossis 100G ntawm ob lub fibers siv dual -wavelength CWDM, zam qhov yuav tsum tau muaj fiber ntau tib yam nkaus. Qhov kev txwv yog tus nqi transceiver (BiDi QSFP28 ntawm kwv yees li 2–3 × tus qauv SR4) thiab tus neeg muag khoom xauv -nyob rau hauv kev xaiv optic.
Cov kev taw qhia txog kev tsim vaj tsev: cov koom haum npaj kev tsim kho vaj tse uas yuav xav tau kev txhawb nqa 400G hauv 3-5 xyoo yuav tsum muab MPO-npaj thaj vaj huam sib luag (chassis-raws li, cassette- sib haum) txawm tias thawj cov pej xeem siv LC duplex cassettes. Lub chassis sawv cev rau tus nqi qis me me tab sis khaws lub peev xwm los pauv mus rau MPO cassettes yam tsis tau rov ua cov pob txha caj qaum.
| Qhov xwm txheej | LC Duplex Vaj Huam Sib Luag | MPO Cassette Vaj Huam Sib Luag | Kev soj ntsuam |
|---|---|---|---|
| Tus nqi pib qhov chaw nres nkoj | qis | Siab dua (+20–40%) | LC yeej |
| 400G npaj | Yuav tsum tau recabling qaum | Swap cassette hom nkaus xwb | MPO yeej |
| Connector suav rau ib qhov txuas | 4 interfaces | 8 interfaces | LC yeej |
| Installation ceev | Standard (kev txiav tawm los yog patching) | Ceev ceev (ua ntej-tawm lub cev) | MPO yeej |
| Poob nyiaj txiag ib qhov txuas | Tsawg tag nrho (4 connectors) | Siab dua (0.3-0.5 dB MPO nyiaj siv ua haujlwm) | LC yeej |
| Parallel 100G / 400G kev txhawb nqa | Yuav tsum tau BiDi lossis breakout pob | Native 8-fiber / 4-fiber parallel | MPO yeej |
| Polarity yuam kev txaus ntshai | Tsawg kawg (ib tus neeg fiber ntau) | Qhov tseem ceeb (12/24 fibers cuam tshuam) | LC yeej |
| Maintenance access (rov qab) | Direct LC nkag, yooj yim tu | MPO rear nkag yuav tsum tau ib nrab disassembly | LC yeej |
Lub rooj tsis tsim ib tug meej yeej - uas yog lawm. Qhov kev txiav txim siab yog cov ntsiab lus - nyob ntawm, thiab qhov tseem ceeb ntawm qhov sib txawv yog qhov xav tau ntawm lub sijhawm tsiv teb tsaws mus rau qhov sib npaug ntawm optics. Yog tias 400G kev xa tawm raug npaj ua ntej 3 xyoos, MPO tus nqi tsim nyog tau tsim nyog. Yog tias 400G yog 7-10 xyoo qab ntug, LC duplex mus kom ze nrog BiDi optics ntawm txheej transceiver yuav raug nqi qis dua.
Labeling Systems Uas Fail ntawm Scale
Fiber thaj vaj huam sib luag daim ntawv lo yog kho raws li qhov kev txhawj xeeb ntawm lub sijhawm tsim thiab qhov teeb meem tseem ceeb ntawm kev ua haujlwm ntawm xyoo 2. Cov hom kev ua tsis tiav yog zoo ib yam nyob rau hauv ntau hom kev xa tawm:
Adhesive daim ntawv degradation.Cov ntawv nplaum txheem siv rau cov hlua khi hlua khi degrade hauv cov ntaub ntawv chaw ib puag ncig vim cua sov, kev co, thiab rov sib cuag thaum lub sij hawm tswj kav. Hauv 3- lub sijhawm ua haujlwm xyoo, 30–50% ntawm cov ntawv nplaum hauv thaj chaw ua haujlwm siab yuav qhia tau tias txo qis, nrog 10-20% dhau los ua tsis tau tag nrho. Qhov no ua rau lub luag haujlwm saib xyuas lub luag haujlwm uas tsis tshua muaj peev txheej hauv kev siv nyiaj txiag.
Lub npe hu ua convention drift.Hauv ib puag ncig uas tswj hwm los ntawm ntau tus kws tshaj lij tshaj li ntau- xyoo, tsis muaj cov ntaub ntawv sau npe nruj me ntsis, cov ntawv sau npe sib txawv ntawm lub rooj sib tham dhau sijhawm. Chaw nres nkoj A-1-24 dhau los ua "switch-3-port-24" ua "sw3p24" dhau los "sw3-24" raws li cov kws tshaj lij sib txawv siv lawv tus kheej shorthand. Cov ntawv hla kev xa mus rau cov ntaub ntawv hauv lub network yuav tsis ntseeg tau.
High -Density label occlusion.Ntawm 96 lossis ntau qhov chaw nres nkoj ib 1U, ib tus neeg cov ntawv cim chaw nres nkoj ntawm lub ntsej muag ntawm lub ntsej muag yog lub cev me me rau kev nyeem ntawv zoo yam tsis muaj kev nthuav dav hauv cov ntaub ntawv chaw teeb pom kev zoo ib puag ncig. Qhov teeb meem no tsis muaj kev daws teeb meem ntawm ultra-high density - nws yog ib qho kev txwv lub cev ntawm daim ntawv.
Kev ua haujlwm ruaj khov rau daim ntawv lo rau thaj chaw yuav tsum tau: luam tawm cov cua sov-shrink lossis clip- ntawm cov ntawv sau rau ntawm ob qho kawg ntawm txhua txoj hlua (tsis nplaum), ib daim ntawv pov thawj thiab kev tswj hwm lub npe tau ntes hauv cov ntaub ntawv tswj hwm network, thiab vaj huam sib luag- cov duab kos duab (lub cev lossis digital). Rau kev xa tawm saum 200 qhov chaw nres nkoj, ib qho kev tswj xyuas cable tshwj xeeb (xws li NetBox lossis cov cuab yeej DCIM zoo sib xws) synchronized rau cov ntaub ntawv teeb tsa lub cev ua rau txo qis lub sijhawm sib cais.
Kev Tshawb Fawb Txog Kev Lag Luam: Yuav Ua Li Cas Qhia Tias Feem Ntau Cov Neeg Yuav Tsis Ua
Standard thaj vaj huam sib luag kev yuav khoom specifications feem ntau chaw nyob: chaw nres nkoj suav, chaw nres nkoj hom (LC/SC/MPO), fiber ntau hom (OS2/OM4), thiab vaj huam sib luag daim foos (1U/2U). Cov kev ntsuas no tsim nyog tab sis tsis txaus. Cov lus qhia hauv qab no feem ntau raug tshem tawm los ntawm kev yuav khoom thiab tom qab ntawd dhau los ua qhov chaw ua haujlwm lossis teeb meem kev ua haujlwm:
Engineering Summary: Kev txiav txim siab uas txhais tau ntev -Lub Sijhawm Ua Haujlwm
Fiber thaj vaj huam sib luag yog cov khoom tsis muaj zog uas tsis muaj qhov txav ntawm qhov chaw. Lawv cov qauv tsis ua tiav yog txiav txim siab tag nrho los ntawm kev txiav txim siab tsim ua ntej kev teeb tsa, thiab los ntawm kev saib xyuas cov txheej txheem siv tom qab kev teeb tsa. Cov kev txiav txim siab uas tsim cov nuj nqis txij nkawm yog kwv yees:
Xaiv ultra- siab- cov vaj huam sib luag ntom ntom rau siab -MAC cov cheeb tsam tsim rau ib - cov nqi ua haujlwm chaw nres nkoj uas ua rau cov nqi txuag nyiaj hauv 18-24 lub hlis. Kev siv cov tshuab cassette yam tsis muaj kev suav nyiaj rau tom qab MPO connector accessibility tsim kom muaj cov kab mob sib kis uas tsis tuaj yeem nkag mus rau kev tu tus qauv. Tsis quav ntsej txoj kev polarity ntawm kev tsim qauv tsim cov kev ua yuam kev uas ntsuas linearly nrog cov chaw nres nkoj suav. Kev sib txuas ua haujlwm yam tsis muaj kev cuam tshuam nyiaj txiag kev lag luam degradation reserves lav tsis tau piav qhia hauv xyoo 3-5.
Tsis muaj ib qho ntawm cov kev ua tsis tiav no yuav tsum muaj cov xwm txheej txawv txawv. Lawv yog cov txiaj ntsig ntawm kev ua haujlwm ib txwm ua ntawm kev txiav txim siab engineering ib txwm ua yam tsis suav nrog kev ua haujlwm tiag tiag.
Txoj hauv kev kom raug yog los tsim lub vaj huam sib luag los ntawm kev ua haujlwm kawg rov qab: txhais cov kev xav tau ntawm MAC cadence, txhais cov kev xav tau kev nkag mus rau kev tu, txhais cov qauv polarity raws li qhov system-wide attribute, qhia txog cov peev nyiaj poob uas suav nrog cov degradation reserves, thiab muab cov khoom sib xyaws - panels, cassettes, trunks} cov ntaub ntawv raws li kev ua tau zoo ntawm tus neeg siv cov kab ke cov khoom optimized ntawm tus nqi tsev.
Glory Optical khoom siv siab- ntom fiber ntau thaj vaj huam sib luag, MPO/MTP cassette systems, OS2 thiab OM4/OM5 ua ntej-tawm lub cev cables, thiab ODF thav duab raws li cov txheej txheem teeb tsa. Tag nrho cov khoom cassette nkoj nrog rau ib -chaw nres nkoj IL/RL cov ntaub ntawv xeem. Txoj kev polarity yog sau tseg ntawm txhua yam khoom MPO. Kev cai vaj huam sib luag configurations, cassette hom mixs, thiab OEM labeling muaj. Cov qauv dawb rau cov kev ntsuam xyuas tsim nyog; 2-teev nqe lus teb.
→ Data Center Cabling Product Range · Thov Kev Sib Tham Engineering
Standards thiab Specifications Referenced
IEC 61754-4: Cov.Fiber optic connector interfaces - Hom LC connector tsev neeg. Txhais LC mechanical interface geometry thiab mating durability yuav tsum.
IEC 61754-7-1: Cov.Fiber optic connector interfaces - Hom MPO connector tsev neeg. Txhais MPO lub cev tshwj xeeb nrog rau kev taw qhia tseem ceeb thiab fiber ntau array geometry.
IEC 61300-3-4: Kev qhiaFiber optic interconnecting pab kiag li lawm - ntsuas ntsuas ntawm qhov poob thiab rov poob. Txhais kev ntsuas kev ntsuas rau kev ua haujlwm kho qhov muag txuas.
IEC 61300-3-35: Kev qhiaKev tshuaj xyuas thiab ntsuas ntawm fiber ntau optic connectors - kev soj ntsuam pom thiab automated. Txhais kev sib cais ntawm cov kab mob sib kis rau qhov kawg connector -kev tshuaj xyuas ntsej muag.
TIA-568.3-D:Optical Fiber Cable Cheebtsam Standard. Txhais txoj kev polarity (A/B/C) rau MPO-raws li cov kab ke.
TIA-569-D:Telecommunications Pathways thiab Chaw. Txhais qhov tsawg kawg nkaus khoov lub vojvoog thiab txhawb nqa lub caij nyoog rau fiber ntau cabling hauv kev teeb tsa.
IEC 60529 Tus IP Code:Qib ntawm kev tiv thaiv muab los ntawm enclosures. Muaj feem xyuam rau FTTH ODF kev teeb tsa sab nraum zoov -ib puag ncig lossis OSP ib puag ncig.
IEEE 802.3bm:40 Gb / s thiab 100 Gb / s fiber ntau optic ua hauj lwm quab yuam. Txhais cov peev nyiaj siv hluav taws xob kho qhov muag rau 100GBASE-SR4 OM4 multimode txuas.