LC UPC rau LC UPC luv khau raj Duplex OM3 Fiber Patch Cable rau siab -Density 10G/40G/100G Txuas

Glory Optical LC UPC rau LC UPC luv khau raj duplex OM3 fiber ntau thaj cable yog tsim rau cov chaw zov me nyuam, kev sib txuas lus thiab kev lag luam cabling ib puag ncig uas ceev ntsaws- thiab- ua si xa tawm, huv si hla- kev sib txuas thiab txwv qhov chaw khib nyiab yog qhov tseem ceeb.
Lub khoov-insensitive OM3 50/125μm fiber ntau, 12mm luv khau raj LC connectors thiab 2.0mm OFNR nruj-buffered aqua tsho ua rau nws haum rau luv- mus rau nruab nrab- nrug multimode Ethernet interconnects thiab siab -zones patching.
Ua ntej-Terminated Cable rau Fast Interconnect thiab Hla-Txuas
Ua ntej-tawm LC duplex jumpers muab kev npaj ua ntej-- siv ntsaws- thiab- ua si daws rau cov kab hluav taws xob loj. Lawv txo qhov kev txiav tawm ua haujlwm, txo lub sijhawm teeb tsa thiab ua kom txav mus, ntxiv thiab hloov pauv yooj yim dua hauv cov khoom siv chav, MDA / EDA zones, telecom racks thiab enterprise network txee.
Vim li cas Short Boot Matters
Lub 12 hli luv khau raj tshem tawm qhov xav tau rau lub tshav kub ntev -shrink tube thiab shortens lub connector los ua ke li ntawm 30% piv nrog ntau tus qauv- khau raj tsim. Qhov no muab cov neeg teeb tsa ntau txoj kev ywj pheej nyob rau hauv qhov chaw nqaim thaum txhim kho cable yooj yam tsis muaj kev cuam tshuam rau kev sib kis.
Ntsiab nta
Nplooj ntawv no tso lub cable nyob ib ncig ntawm tus nqi xa tawm tiag tiag: cov cab kuj- qib kis tau tus mob stability, compact khau raj tsim, khoov- insensitive routing thiab sai siab - ceev installation.
Technical Specifications
| Khoom npe | LC UPC rau LC UPC luv khau raj Duplex OM3 Multimode Fiber Patch Cable |
|---|---|
| Reference Length | 1 m / 3 ft |
| Connector A | LC UPC Duplex |
| Connector B | LC UPC Duplex |
| Fiber suav | 2 fibers |
| Fiber Qib | Khoov-sensitive fiber |
| Fiber hom | OM 3 50/125μm multimode |
| Lub wavelength | 850 / 1300 nm |
| Kev ntsuas nplaim taws | Riser / OFNR |
| Cable Outer Diameter | 2.0 hli |
| Hom khau raj | 12mm luv khau raj |
| Jacket Xim | Aqua |
| Polarity | A (Tx) to B (Rx) |
| Hom kab | Tight -buffed |
| Yam tsawg kawg Khoov Radius - Fiber | 7.5mm ib |
| Yam tsawg kawg Khoov Radius - Cable | 20D / 10D, dynamic / zoo li qub |
| Connector Durability | 1000 mating cycles |
| Tensile zog | 90 / 150N, ntev -term / luv-term |
| Insertion Loss | Tsawg dua lossis sib npaug li 0.3dB |
| Rov Los Los | Ntau dua lossis sib npaug li 30dB |
| Attenuation ntawm 850nm | Tsawg dua lossis sib npaug li 3.5dB / km |
| Attenuation ntawm 1300nm | Tsawg dua lossis sib npaug li 1.5dB / km |
| Ua haujlwm kub | -10℃rau +70 degree |
| Cia Kub | -20℃rau +70 degree |
| Ua raws | Cov ntaub ntawv ua raws li qhov project thiab cov ntaub ntawv xeem tuaj yeem muab tau raws li qhov yuav tsum tau ua. |
Kev sib txuas daws teeb meem
Qhov no duplex OM3 cable tuaj yeem txhawb nqa tau tshaj multimode transceiver channels thiab khib-theem interconnects thaum xaiv optics, kev ncua deb thiab cov peev nyiaj txuas tau raug sib raug zoo.
Daim ntawv thov Scenario
High -Density Rack Patching
Luv luv BIF cable yog tsim rau MDA thiab EDA thaj tsam thaj chaw uas cov cables yuav tsum dhau ntawm qhov chaw nqaim kom huv.
Cov khoom siv sib txuas
Txuas LC duplex multimode ports ntawm cov keyboards, panels thiab cov khoom siv kho qhov muag hauv chav sib tham hauv xov tooj.
Enterprise LAN Rooms
Siv rau kev txhim kho kev lag luam network, hloov - mus rau - vaj huam sib luag jumpers thiab hauv zos qaum qaum qaum - txuas.
10G SR Interconnect
OM3 muab bandwidth siab dua li qub multimode fiber ntau thiab yog tus nqi - siv tau rau luv - mus rau nruab nrab - nrug 10G Ethernet.
Tau tshaj Duplex Links
Yuav siv tau rau hauv 40G / 100G duplex multimode daim ntaub ntawv thaum ua ke nrog qhov tseeb optics thiab txoj kev deb.
Visual Port Identification
Aqua xim-cov tsho coded pab cov neeg teeb tsa txheeb xyuas OM3 txoj hauv kev sai, txo qis kev teeb tsa thiab sijhawm sim.
Installation thiab Maintenance Notes
Cov kab hluav taws xob luv luv ua kom yooj yim rau siab - kev teeb tsa ceev, tab sis txoj kev raug cai thiab kev soj ntsuam tseem tseem ceeb rau kev ua haujlwm ntev -.
- Siv nrog LC UPC duplex multimode ports thiab txuam OM3 los yog tshaj multimode raws.
- Tsis txhob siv no OM3 aqua jumper li hloov rau OS2 daj singlemode txuas.
- Ua raws li A-rau-B polarity rau cov ntawv thov kev siv duplex fiber ntau tshwj tsis yog qhov project tau qhia lwm yam.
- Tsis txhob khi nruj- qhwv, khoov ntse, txee lub qhov rooj siab thiab overfilled cable managers.
- Khaws cov kab hluav taws xob saum toj ntawm nws qhov tsawg kawg nkaus lub vojvoog khoov thaum lub sijhawm ua haujlwm thiab tom qab lub qhov rooj kaw.
- Ntxuav LC connector kawg- ntsej muag ua ntej zaum kawg patching los yog optical kuaj.
Common Ordering yuam kev kom zam
LC patch cables yuav zoo sib xws, tab sis qhov sib txawv me me hauv hom fiber ntau, khau raj ntev, polarity thiab lub tsho ntsuam xyuas tuaj yeem ua rau cov khoom tsis raug rau cov khoom khib nyiab.
Tshawb xyuas ua ntej yuav khoom
- Xaiv OM3 aqua rau OM3 multimode txuas, tsis yog OS2 daj singlemode txuas.
- Xaiv lub 12 hli luv khau raj thaum rear clearance yog txwv tom qab LC ports.
- Xaiv duplex thaum lub transceiver siv cais Tx / Rx fibers.
- Paub meej tias OFNR tau txais rau thaj chaw teeb tsa ua ntej xaj.
- Paub meej tias ntev nrog kev tswj cable slack, tsis tsuas yog chaw nres nkoj - mus rau - chaw nres nkoj deb.
Standard vs Short Boot Xaiv
Rau cov nplooj ntawv khoom Glory, qhov kev sib piv no pab cov neeg siv khoom nkag siab tias vim li cas cov qauv no yuav tsum raug xaiv los ntawm tus qauv LC OM3 thaj qaum.
Cov ntaub ntawv RFQ
Txhawm rau hais qhov tseeb cable, thov paub meej tias hom connector, hom khau raj, hom fiber ntau, ntev, lub tsho ntsuas, kab kab thiab ntim.
| RFQ khoom | Standard Configuration | Yuav Qhia Li Cas |
|---|---|---|
| Hom Connector | LC UPC Duplex rau LC UPC Duplex | Paub meej tias LC / LC lossis hybrid LC / SC, UPC lossis APC polish. |
| Hom khau raj | 12mm luv khau raj | Siv lub khau raj luv luv rau siab - cov khib nyiab ceev thiab nruj nraub qaum- tshem tawm vaj huam sib luag. |
| Fiber hom | OM3 50/125μm khoov- fiber ntau insensitive | Paub meej OM3, OM4, OM5, OM2 lossis OS2 raws li qhov txuas tsim. |
| Fiber suav | 2 fibers, duplex | Paub meej tias simplex lossis duplex nyob ntawm qhov xav tau ntawm transceiver. |
| Cable Jacket | 2.0 hli PVC OFNR | Qhia LSZH, plenum lossis lwm lub tsho yog tias qhov project xav tau. |
| Ntev | 1m / 3ft siv | Muab txoj kev ntev ntxiv rau slack rau cable tswj thiab vaj huam sib luag txav. |
| Ntim | 1 daim rau ib lub hnab lossis qhov project-raws li ntim | OEM daim ntawv lo, barcode, SKU daim ntawv lo lossis pob pob tuaj yeem sib tham rau ntim xaj. |
FAQ
Q: Dab tsi yog qhov txiaj ntsig tseem ceeb ntawm 12mm luv khau raj LC thaj cable?
A: The short boot reduces rear projection behind the connector, helping the cable bend more naturally in high-density racks, patch panels and switch ports with limited clearance.
Q: Puas yog qhov no cable singlemode lossis multimode?
A: Nplooj ntawv no yog rau OM{0}}/125μm multimode fiber ntau. Nws yuav tsum tsis txhob siv los hloov OS2 singlemode thaj cables.
Q: Lub tsho aqua txhais li cas?
A: Aqua feem ntau siv los txheeb xyuas OM3 multimode cabling, pab cov kws tshaj lij paub qhov txawv ntawm cov xim daj OS2 singlemode lossis lwm pawg fiber ntau hauv cov khoom sib xyaw.
Q: Cov kab no puas tuaj yeem siv rau 10G, 40G lossis 100G txuas?
A: Nws tuaj yeem siv rau kev sib txuas duplex multimode sib txuas thaum optics, nrug, tsim channel thiab kev sib txuas pob nyiaj tau raws li qhov yuav tsum tau ua. Ib txwm paub meej tias hom transceiver ua ntej xaj.
Q: Qhov no puas tuaj yeem OM3LCSDX- hom cable raug ntsia sab nraum zoov?
A: Tsis yog. Qhov no yog sab hauv tsev OFNR riser cable. Rau sab nraum zoov, huab cua, duct, ncaj qha faus los yog ib puag ncig hnyav, xaiv sab nraum zoov - ntsuas fiber ntau cable hloov.
Q: Dab tsi yog qhov txiaj ntsig ntawm qhov tsis muaj cua sov -shrink luv khau raj tsim?
A: Nws txhim kho kev yooj yim ntawm cable, ua rau cov khoom sib txuas yooj yim dua los ntawm qhov chaw nqaim, thiab ua kom yooj yim rau kev teeb tsa thiab kev saib xyuas yam tsis muaj kev cuam tshuam kev ua haujlwm kho qhov muag.

Peb Kev cog lus zoo
Comprehensive 3-xyoo Warranty
Peb ntseeg siab rov qab tag nrho peb cov khoom nrog a3 xyoo warranty. Peb txoj cai tshwj xeeb rau kev pabcuam yog: nyob rau hauv ib xyoos rau cov teeb meem zoo, peb muaj lub luag haujlwm tag nrho rau kev xa rov qab; hauv ob xyoos, rau kev hloov pauv; thiab nyob rau hauv peb xyoos, rau kev kho.
Clear & Sib tw MOQ
Peb txais tos ob qho tib si mus sib hais thiab ntau xaj. Peb tus qauvYam tsawg kawg nkaus Order Quantity (MOQ) yog 50 units. Peb kuj muabcov qauv dawb rau kev kuajlos pab koj ntsuas peb qhov zoo nrog kev ntseeg siab.
Fast & Reliable Logistics
Peb lav kev xa khoomhauv 10 hnubrau cov khoom txheem. Peb qhov txiaj ntsig logistics suav nrogtus nqi- qhov rooj zoo-rau- qhov rooj pabcuamkom yooj yim shipping rau koj.
Peb lub Foundation
Rov qab los ntawm18 xyoo ntawm kev paubtxij li xyoo 2008, peb tswj tau zoo los ntawm peb lub Hoobkas, txaisOEM / ODMthov, thiab tswjnpaj khoomrau wholesale. Peb tsom mus rau kev xa qhov zoo tshaj plaws tshuav ntawmnqe thiab zooncaj qha raucov neeg siv khoom kawgthoob ntiaj teb.
Koj qhov kev ntseeg siab yog peb qhov tseem ceeb. Koom tes nrog peb rau kev txhawb nqa fiber ntau optic daws kev txhawb nqa los ntawm kev cog lus meej.
Cim npe nrov: Lc upc rau lc upc luv khau raj duplex om3 fiber ntau thaj cable, Tuam Tshoj lc upc rau lc upc luv khau raj duplex om3 fiber ntau thaj cable manufacturers, lwm tus neeg, Hoobkas