LC UPC Rau LC UPC luv khau raj Duplex OM3 Fiber Patch Cable

Xa kev nug
LC UPC Rau LC UPC luv khau raj Duplex OM3 Fiber Patch Cable
Paub meej
Glory Optical LC UPC rau LC UPC luv khau raj duplex OM3 fiber ntau thaj cable yog tsim rau cov chaw zov me nyuam, kev sib txuas lus thiab kev lag luam cabling ib puag ncig uas ceev ntsaws- thiab- ua si xa tawm, huv si hla- kev sib txuas thiab txwv qhov chaw khib nyiab yog qhov tseem ceeb. Qhov khoov-insensitive OM3 50/125μm fiber ntau, 12mm luv khau raj LC connectors thiab 2.0mm OFNR nruj-buffered aqua tsho ua rau nws haum rau luv- mus rau nruab nrab{12}}ntau zaus multimode Ethernet interconnects thiab siab{13} cheeb tsam
Kev faib tawm yam khoom
Fiber Patch Cord
Share to
Hauj lwm lawm

LC UPC rau LC UPC luv khau raj Duplex OM3 Fiber Patch Cable rau siab -Density 10G/40G/100G Txuas

LC UPC to LC UPC Short Boot Duplex OM3 Fiber Patch Cable

Glory Optical LC UPC rau LC UPC luv khau raj duplex OM3 fiber ntau thaj cable yog tsim rau cov chaw zov me nyuam, kev sib txuas lus thiab kev lag luam cabling ib puag ncig uas ceev ntsaws- thiab- ua si xa tawm, huv si hla- kev sib txuas thiab txwv qhov chaw khib nyiab yog qhov tseem ceeb.

Lub khoov-insensitive OM3 50/125μm fiber ntau, 12mm luv khau raj LC connectors thiab 2.0mm OFNR nruj-buffered aqua tsho ua rau nws haum rau luv- mus rau nruab nrab- nrug multimode Ethernet interconnects thiab siab -zones patching.

 
LC UPC ⇄ LC UPCDuplex A-rau-B polarity
OM 3 50/125μmKhoov-sensitive multimode fiber ntau
12mm Short BootRau nruj khib clearance
2.0mm NPETight-buffed aqua riser cable

 

Ua ntej-Terminated Cable rau Fast Interconnect thiab Hla-Txuas

Ua ntej-tawm LC duplex jumpers muab kev npaj ua ntej-- siv ntsaws- thiab- ua si daws rau cov kab hluav taws xob loj. Lawv txo qhov kev txiav tawm ua haujlwm, txo lub sijhawm teeb tsa thiab ua kom txav mus, ntxiv thiab hloov pauv yooj yim dua hauv cov khoom siv chav, MDA / EDA zones, telecom racks thiab enterprise network txee.

Vim li cas Short Boot Matters

Lub 12 hli luv khau raj tshem tawm qhov xav tau rau lub tshav kub ntev -shrink tube thiab shortens lub connector los ua ke li ntawm 30% piv nrog ntau tus qauv- khau raj tsim. Qhov no muab cov neeg teeb tsa ntau txoj kev ywj pheej nyob rau hauv qhov chaw nqaim thaum txhim kho cable yooj yam tsis muaj kev cuam tshuam rau kev sib kis.

Ntsiab nta

Nplooj ntawv no tso lub cable nyob ib ncig ntawm tus nqi xa tawm tiag tiag: cov cab kuj- qib kis tau tus mob stability, compact khau raj tsim, khoov- insensitive routing thiab sai siab - ceev installation.

Carrier-Qib Cable

Kev ruaj ntseg kis tau zoo

Kev sib txuas cable zoo thiab kev txiav txim siab LC UPC pab tswj cov teeb liab ruaj khov thiab ntev - kev cia siab nyob rau hauv qhov chaw ntom ntom cabling.

Tight-Nruab

Tiv thaiv Fiber Core

Lub nruj- cov qauv kab hluav taws xob tiv thaiv cov tub ntxhais fiber ntau thaum tuav thiab pab txuas ntxiv lub neej kev pab cuam hauv tsev khib thiab kev teeb tsa.

Khoov Insensitive

7.5mm Fiber Khoov Radius

Khoov-insensitive OM3 fiber ntau tso cai rau kev sib tw nruj dua li cov tsoos multimode jumpers thiab pab txo qis kev khoov- lossis twist- ntsig txog teeb liab attenuation.

OFNR Jacket

Riser-Rated Sab Hauv Tsev Cable

PVC OFNR lub tsho sab nrauv txhawb nqa kev teeb tsa sab hauv tsev thiab pab txo cov nplaim hluav taws sib kis hauv txoj hauv kev tsim nyog.

Kev poob qis

Tsawg dua lossis sib npaug rau 0.3dB Insertion Poob

Kev poob qis qis txhawb kev kho qhov muag teeb liab lub zog thiab kev sib kis tau zoo hauv 1/10/40/100G tau tshaj duplex multimode raws.

Short Boot

Cleaner Siab -Density Patching

Lub khau raj luv luv pab cov cable hla dhau qhov chaw nqaim, txhim kho kev txhim kho kev ua haujlwm thiab ua kom yooj yim rau kev saib xyuas cable yav tom ntej.

 

Technical Specifications

Khoom npe LC UPC rau LC UPC luv khau raj Duplex OM3 Multimode Fiber Patch Cable
Reference Length 1 m / 3 ft
Connector A LC UPC Duplex
Connector B LC UPC Duplex
Fiber suav 2 fibers
Fiber Qib Khoov-sensitive fiber
Fiber hom OM 3 50/125μm multimode
Lub wavelength 850 / 1300 nm
Kev ntsuas nplaim taws Riser / OFNR
Cable Outer Diameter 2.0 hli
Hom khau raj 12mm luv khau raj
Jacket Xim Aqua
Polarity A (Tx) to B (Rx)
Hom kab Tight -buffed
Yam tsawg kawg Khoov Radius - Fiber 7.5mm ib
Yam tsawg kawg Khoov Radius - Cable 20D / 10D, dynamic / zoo li qub
Connector Durability 1000 mating cycles
Tensile zog 90 / 150N, ntev -term / luv-term
Insertion Loss Tsawg dua lossis sib npaug li 0.3dB
Rov Los Los Ntau dua lossis sib npaug li 30dB
Attenuation ntawm 850nm Tsawg dua lossis sib npaug li 3.5dB / km
Attenuation ntawm 1300nm Tsawg dua lossis sib npaug li 1.5dB / km
Ua haujlwm kub -10℃rau +70 degree
Cia Kub -20℃rau +70 degree
Ua raws Cov ntaub ntawv ua raws li qhov project thiab cov ntaub ntawv xeem tuaj yeem muab tau raws li qhov yuav tsum tau ua.

 

Kev sib txuas daws teeb meem

Qhov no duplex OM3 cable tuaj yeem txhawb nqa tau tshaj multimode transceiver channels thiab khib-theem interconnects thaum xaiv optics, kev ncua deb thiab cov peev nyiaj txuas tau raug sib raug zoo.

1/10G DuplexFeem ntau LC duplex kev sib txuas ncaj qha hauv LAN thiab cov khoom siv hauv tsev.
40/100G DuplexRau kev sib tw duplex multimode optics qhov twg txhawb nqa los ntawm tus qauv transceiver.
Hloov chaw nres nkojLC multimode transceiver lossis khoom siv interface.
Patch Vaj Huam Sib LuagHigh -Density LC adapter vaj huam sib luag los yog cassette.
Hla -TxuasMDA, EDA, LAN chav lossis chaw lag luam khib patching.

 

Daim ntawv thov Scenario

Data Center

High -Density Rack Patching

Luv luv BIF cable yog tsim rau MDA thiab EDA thaj tsam thaj chaw uas cov cables yuav tsum dhau ntawm qhov chaw nqaim kom huv.

Telecom Network

Cov khoom siv sib txuas

Txuas LC duplex multimode ports ntawm cov keyboards, panels thiab cov khoom siv kho qhov muag hauv chav sib tham hauv xov tooj.

LAN

Enterprise LAN Rooms

Siv rau kev txhim kho kev lag luam network, hloov - mus rau - vaj huam sib luag jumpers thiab hauv zos qaum qaum qaum - txuas.

10G Duplex

10G SR Interconnect

OM3 muab bandwidth siab dua li qub multimode fiber ntau thiab yog tus nqi - siv tau rau luv - mus rau nruab nrab - nrug 10G Ethernet.

40/100G

Tau tshaj Duplex Links

Yuav siv tau rau hauv 40G / 100G duplex multimode daim ntaub ntawv thaum ua ke nrog qhov tseeb optics thiab txoj kev deb.

Cable Management

Visual Port Identification

Aqua xim-cov tsho coded pab cov neeg teeb tsa txheeb xyuas OM3 txoj hauv kev sai, txo qis kev teeb tsa thiab sijhawm sim.

 

 

 

Installation thiab Maintenance Notes

Cov kab hluav taws xob luv luv ua kom yooj yim rau siab - kev teeb tsa ceev, tab sis txoj kev raug cai thiab kev soj ntsuam tseem tseem ceeb rau kev ua haujlwm ntev -.

  • Siv nrog LC UPC duplex multimode ports thiab txuam OM3 los yog tshaj multimode raws.
  • Tsis txhob siv no OM3 aqua jumper li hloov rau OS2 daj singlemode txuas.
  • Ua raws li A-rau-B polarity rau cov ntawv thov kev siv duplex fiber ntau tshwj tsis yog qhov project tau qhia lwm yam.
  • Tsis txhob khi nruj- qhwv, khoov ntse, txee lub qhov rooj siab thiab overfilled cable managers.
  • Khaws cov kab hluav taws xob saum toj ntawm nws qhov tsawg kawg nkaus lub vojvoog khoov thaum lub sijhawm ua haujlwm thiab tom qab lub qhov rooj kaw.
  • Ntxuav LC connector kawg- ntsej muag ua ntej zaum kawg patching los yog optical kuaj.

 

Common Ordering yuam kev kom zam

LC patch cables yuav zoo sib xws, tab sis qhov sib txawv me me hauv hom fiber ntau, khau raj ntev, polarity thiab lub tsho ntsuam xyuas tuaj yeem ua rau cov khoom tsis raug rau cov khoom khib nyiab.

Tshawb xyuas ua ntej yuav khoom

  • Xaiv OM3 aqua rau OM3 multimode txuas, tsis yog OS2 daj singlemode txuas.
  • Xaiv lub 12 hli luv khau raj thaum rear clearance yog txwv tom qab LC ports.
  • Xaiv duplex thaum lub transceiver siv cais Tx / Rx fibers.
  • Paub meej tias OFNR tau txais rau thaj chaw teeb tsa ua ntej xaj.
  • Paub meej tias ntev nrog kev tswj cable slack, tsis tsuas yog chaw nres nkoj - mus rau - chaw nres nkoj deb.

 

Standard vs Short Boot Xaiv

Rau cov nplooj ntawv khoom Glory, qhov kev sib piv no pab cov neeg siv khoom nkag siab tias vim li cas cov qauv no yuav tsum raug xaiv los ntawm tus qauv LC OM3 thaj qaum.

Short Boot OM3Qhov zoo tshaj plaws rau siab -racks, MDA/EDA zones thiab nruj rear{1}} clearance patching.
Standard Boot OM3Haum rau dav dav patching qhov chaw rear cable tsis txwv.
10-Pack SupplyMuaj txiaj ntsig rau kev xa tawm cov khoom siv, kev ntxuav khib nyiab thiab kev hloov cov kab hluav taws xob.
Custom LengthQhov project-raws li qhov ntev, daim ntawv lo thiab ntim rau cov neeg cog lus thiab cov neeg xa khoom.

 

Cov ntaub ntawv RFQ

Txhawm rau hais qhov tseeb cable, thov paub meej tias hom connector, hom khau raj, hom fiber ntau, ntev, lub tsho ntsuas, kab kab thiab ntim.

RFQ khoom Standard Configuration Yuav Qhia Li Cas
Hom Connector LC UPC Duplex rau LC UPC Duplex Paub meej tias LC / LC lossis hybrid LC / SC, UPC lossis APC polish.
Hom khau raj 12mm luv khau raj Siv lub khau raj luv luv rau siab - cov khib nyiab ceev thiab nruj nraub qaum- tshem tawm vaj huam sib luag.
Fiber hom OM3 50/125μm khoov- fiber ntau insensitive Paub meej OM3, OM4, OM5, OM2 lossis OS2 raws li qhov txuas tsim.
Fiber suav 2 fibers, duplex Paub meej tias simplex lossis duplex nyob ntawm qhov xav tau ntawm transceiver.
Cable Jacket 2.0 hli PVC OFNR Qhia LSZH, plenum lossis lwm lub tsho yog tias qhov project xav tau.
Ntev 1m / 3ft siv Muab txoj kev ntev ntxiv rau slack rau cable tswj thiab vaj huam sib luag txav.
Ntim 1 daim rau ib lub hnab lossis qhov project-raws li ntim OEM daim ntawv lo, barcode, SKU daim ntawv lo lossis pob pob tuaj yeem sib tham rau ntim xaj.

 

FAQ

Q: Dab tsi yog qhov txiaj ntsig tseem ceeb ntawm 12mm luv khau raj LC thaj cable?

A: The short boot reduces rear projection behind the connector, helping the cable bend more naturally in high-density racks, patch panels and switch ports with limited clearance.

Q: Puas yog qhov no cable singlemode lossis multimode?

A: Nplooj ntawv no yog rau OM{0}}/125μm multimode fiber ntau. Nws yuav tsum tsis txhob siv los hloov OS2 singlemode thaj cables.

Q: Lub tsho aqua txhais li cas?

A: Aqua feem ntau siv los txheeb xyuas OM3 multimode cabling, pab cov kws tshaj lij paub qhov txawv ntawm cov xim daj OS2 singlemode lossis lwm pawg fiber ntau hauv cov khoom sib xyaw.

Q: Cov kab no puas tuaj yeem siv rau 10G, 40G lossis 100G txuas?

A: Nws tuaj yeem siv rau kev sib txuas duplex multimode sib txuas thaum optics, nrug, tsim channel thiab kev sib txuas pob nyiaj tau raws li qhov yuav tsum tau ua. Ib txwm paub meej tias hom transceiver ua ntej xaj.

Q: Qhov no puas tuaj yeem OM3LCSDX- hom cable raug ntsia sab nraum zoov?

A: Tsis yog. Qhov no yog sab hauv tsev OFNR riser cable. Rau sab nraum zoov, huab cua, duct, ncaj qha faus los yog ib puag ncig hnyav, xaiv sab nraum zoov - ntsuas fiber ntau cable hloov.

Q: Dab tsi yog qhov txiaj ntsig ntawm qhov tsis muaj cua sov -shrink luv khau raj tsim?

A: Nws txhim kho kev yooj yim ntawm cable, ua rau cov khoom sib txuas yooj yim dua los ntawm qhov chaw nqaim, thiab ua kom yooj yim rau kev teeb tsa thiab kev saib xyuas yam tsis muaj kev cuam tshuam kev ua haujlwm kho qhov muag.


gloryoptic
Peb Kev cog lus zoo

Comprehensive 3-xyoo Warranty

Peb ntseeg siab rov qab tag nrho peb cov khoom nrog a3 xyoo warranty. Peb txoj cai tshwj xeeb rau kev pabcuam yog: nyob rau hauv ib xyoos rau cov teeb meem zoo, peb muaj lub luag haujlwm tag nrho rau kev xa rov qab; hauv ob xyoos, rau kev hloov pauv; thiab nyob rau hauv peb xyoos, rau kev kho.

Clear & Sib tw MOQ

Peb txais tos ob qho tib si mus sib hais thiab ntau xaj. Peb tus qauvYam tsawg kawg nkaus Order Quantity (MOQ) yog 50 units. Peb kuj muabcov qauv dawb rau kev kuajlos pab koj ntsuas peb qhov zoo nrog kev ntseeg siab.

Fast & Reliable Logistics

Peb lav kev xa khoomhauv 10 hnubrau cov khoom txheem. Peb qhov txiaj ntsig logistics suav nrogtus nqi- qhov rooj zoo-rau- qhov rooj pabcuamkom yooj yim shipping rau koj.

Peb lub Foundation

Rov qab los ntawm18 xyoo ntawm kev paubtxij li xyoo 2008, peb tswj tau zoo los ntawm peb lub Hoobkas, txaisOEM / ODMthov, thiab tswjnpaj khoomrau wholesale. Peb tsom mus rau kev xa qhov zoo tshaj plaws tshuav ntawmnqe thiab zooncaj qha raucov neeg siv khoom kawgthoob ntiaj teb.

 

Koj qhov kev ntseeg siab yog peb qhov tseem ceeb. Koom tes nrog peb rau kev txhawb nqa fiber ntau optic daws kev txhawb nqa los ntawm kev cog lus meej.

Cim npe nrov: Lc upc rau lc upc luv khau raj duplex om3 fiber ntau thaj cable, Tuam Tshoj lc upc rau lc upc luv khau raj duplex om3 fiber ntau thaj cable manufacturers, lwm tus neeg, Hoobkas

Xa kev nug