1 × 32 PLC Fiber Optic Splitter: Daim ntawv qhia ua tiav rau Specs, Daim Ntawv Thov, thiab Kev Xaiv

Jun 24, 2026

Tso lus

info-1267-845

1 × 32 PLC Splitter yog dab tsi?

Ib qho 1 × 32 PLC (Planar Lightwave Circuit) splitter yog ib qho khoom siv kho qhov muag uas siv ib qho kev tawm tswv yim kho qhov muag thiab faib nws sib npaug thoob plaws 32 cov zis fibers. Nws yog "passive" vim tias nws yuav tsum tsis muaj lub zog thiab tsis muaj hluav taws xob ua haujlwm - nws tsuas yog faib lub teeb siv ib qho kev sib xyaw waveguide nti fabricated ntawm silica substrate.

Lub npe "1 × 32" txhais tau hais tias ib qho chaw nkag thiab peb caug -ob qhov chaw nres nkoj. Qhov sib cais yog 50/50, txhais tau hais tias lub zog tawm tswv yim raug faib sib npaug thoob plaws txhua qhov kev tawm, tsis hais cov tswv yim wavelength. Qhov kev ywj pheej wavelength no yog qhov txiaj ntsig tseem ceeb ntawm PLC thev naus laus zis: txawm tias koj tab tom khiav GPON ntawm 1490nm, XGS-PON ntawm 1577nm, lossis CATV ntawm 1550nm, lub splitter ua haujlwm tas li.

PLC splitters muaj nyob rau hauv ntau hom pob: ABS box modules, LGX cassettes, steel tube pob, thiab liab qab fiber ntau chips. ABS lub thawv hom- ntsuas tsuas yog 18 × 120 × 80mm- yog qhov ntau tshaj plaws rau FTTH kev xa tawm vim nws qhov loj me thiab yooj yim ntawm kev teeb tsa hauv txoj kev txee, lub thawv xa khoom, thiab kev sib txuas kaw.

 

PLC splitter ua haujlwm li cas?

Tsis zoo li cov tsoos fused biconical taper (FBT) splitters, uas yog tsim los ntawm cua sov thiab fusing ntau fibers ua ke, PLC splitters yog tsim los siv semiconductor photolithography.

Cov txheej txheem pib nrog lub silica substrate, mus rau qhov uas ib tug series ntawm optical waveguides yog etched. Cov waveguides no tsim cov qauv kev sib txuas- pib los ntawm ib qho kev tawm tswv yim channel thiab sib faib ua ntu zus los ntawm Y- zoo li junctions kom txog rau thaum 32 cov zis tawm tau tsim. Tag nrho cov nti yog tom qab ntawd ntim rau hauv ib lub vaj tsev tiv thaiv, nrog cov tswv yim thiab cov zis fibers txuas.

Txoj kev fabrication no muab ntau yam zoo:

Qhov tseeb channel uniformity: Txhua qhov tso zis tau txais yuav luag tib lub zog kho qhov muag.

Kev ywj pheej wavelength: Kev ua tau zoo nyob ib puag ncig ntawm qhov dav wavelength ntau yam.

Kev ntseeg siab: tsis muaj qhov txav mus los thiab tsis muaj cov khoom degradation dhau sijhawm.

PLC splitters yog qhov kev xaiv zoo tshaj plaws rau qhov loj - nplai, siab - kev ua tau zoo ntawm fiber ntau optic tes hauj lwm vim lawv cov precision, durability, thiab wavelength yooj.

 

Cov ntsiab lus tseem ceeb ntawm 1 × 32 PLC Splitter

info-2048-1142

Thaum ntsuas 1 × 32 PLC splitter, cov lus qhia hauv qab no yog qhov tseem ceeb:

Parameter

Specification

Hom pob

ABS Box

Port Configuration

1×32

Hom Fiber

G.657A1 (khoov-insensitive)

Fiber Diameter

2.0 hli

Fiber Length

1.5M

Insertion Loss (IL)

Tsawg dua lossis sib npaug li 17dB

Rov Los Loss (RL)

Ntau dua lossis sib npaug li 55dB

Uniformity (UF)

Tsawg dua lossis sib npaug li 1.5dB

Kev ncaj ncees (DIR)

Ntau dua lossis sib npaug li 55dB

PDL

Tsawg dua lossis sib npaug li 0.3dB

TDL

Tsawg dua lossis sib npaug li 0.5dB

WDL

Tsawg dua lossis sib npaug li 0.5dB

Ua haujlwm Wavelength

1260-1650 nm

Ua haujlwm kub

-40 ~ 85 degree

Cia kub

-40 ~ 85 degree

Qhov Loj (H × W × D)

18×120×80

 

To taub Cov Naj Npawb

Insertion poob (tsawg dua lossis sib npaug rau 17dB):Qhov no yog tag nrho optical fais fab poob thaum lub teeb liab dhau los ntawm lub splitter. Qhov poob ntawm 17dB txhais tau hais tias yog 0dBm nkag mus rau hauv lub splitter, kwv yees li -17dBm tawm txhua qhov chaw tso zis. Qhov no yog nyob rau hauv 28dB poob peev ntawm cov txheej txheem GPON systems thiab yooj yim nyob rau hauv Class C + pob nyiaj siv. Kev lag luam benchmarks qhia 1 × 32 splitters feem ntau muaj qhov poob ntawm 17.2dB.

Rov Los Loss (Ntau dua lossis sib npaug rau 55dB):Qhov no ntsuas ntau npaum li cas lub teeb rov qab mus rau qhov chaw. Kev poob rov qab ntau dua yog qhov zoo dua - nws txhais tau tias tsawg dua lub teeb cuam tshuam nrog lub teeb liab. Rau APC connectors, rov poob tuaj yeem ncav cuag Ntau dua lossis sib npaug li 65dB.

Uniformity (tsawg dua lossis sib npaug rau 1.5dB):Qhov no yog qhov sib txawv siab tshaj plaws hauv qhov poob ntawm ob qhov chaw tso zis. Kev sib raug zoo ua kom ntseeg tau tias txhua tus neeg siv khoom tau txais cov teeb liab tib lub zog, ua kom yooj yim rau kev npaj network.

Wavelength ntau yam (1260 ~ 1650nm):Qhov no suav nrog O-band los ntawm L-band, txhawb GPON (1490nm), XGS-PON (1577nm), NG-PON2, thiab CATV daim ntawv thov.

Qhov kub thiab txias (-40 ~ 85 ℃):Lub tshuab hluav taws xob ua haujlwm tau ntseeg tau los ntawm qhov txias txias mus rau qhov kub siab, ua rau nws tsim nyog rau cov khoom siv sab nraum zoov, kev teeb tsa hauv huab cua, thiab cov khoom siv tsis muaj cua sov.

 

PLC vs. FBT: Vim li cas PLC Yeej rau FTTH

 

Lwm txoj hauv kev rau PLC splitters yog FBT (Fused Biconical Taper) thev naus laus zis. Kev nkag siab txog qhov sib txawv pab piav qhia tias vim li cas PLC yog tus qauv rau cov tes hauj lwm niaj hnub no.

FBT splittersyog tsim los ntawm cua sov thiab fusing ntau fibers ua ke, ces tapering lawv los tsim ib co coupling cheeb tsam. Txoj kev no yooj yim thiab pheej yig tab sis muaj cov kev txwv tseem ceeb:

• Cov kev faib ua piv txwv yog txwv rau 1 × 2, 1 × 4, thiab qee zaus 1 × 8

• Uniformity degrades raws li qhov sib cais nce -qee cov zis tau txais lub zog ntau dua li lwm tus

• Kev ua tau zoo yog wavelength - nyob ntawm

• Tsawg dua kev ntseeg siab rau loj - kev xa tawm

PLC splitterskov yeej tag nrho cov kev txwv no:

• Split ratios mus txog 1 × 64, 1 × 128, thiab tshaj

• Zoo heev uniformity tsis hais qhov sib cais

• Wavelength -kev ua tau zoo

• Kev ntseeg siab dua thiab ua haujlwm ntev dua

FBT splitters tseem tsim nyog rau tus nqi -sensitive, me- nplai daim ntawv thov. Tab sis rau niaj hnub FTTH tes hauj lwm uas yuav tsum tau muaj kev ruaj ntseg, siab phua ratios, thiab ntev -lub sij hawm cia siab, PLC splitters yog qhov kev xaiv meej.

 

Daim ntawv thov: Qhov twg siv 1 × 32 PLC Splitter

 

Lub 1 × 32 PLC splitter yog siv nyob rau hauv ntau lub network txheej:

FTTH/FTTx Networks

Hauv Fiber-rau--Kev xa tawm hauv tsev, 1 × 32 splitter feem ntau yog nruab rau hauv txoj kev txee lossis lub tsev hauv qab daus. Nws siv lub feeder fiber ntau los ntawm OLT thiab faib cov teeb liab rau 32 lub tsev lossis kev lag luam. Ib qhov chaw nres nkoj OLT pub 32 tus neeg rau npe- qhov ceev uas sib npaug tus nqi thiab kev pab them nqi zoo.

PON Networks (GPON, XGS-PON, EPON)

PLC splitters yog lub hauv paus ntawm tag nrho cov passive optical networks. Lawv ua kom lub ntsiab lus -rau-ntau qhov chaw architecture uas ua rau PON raug nqi- zoo. Ib qho chaw OLT nkaus xwb tuaj yeem ua haujlwm rau 32 tus neeg siv yam tsis tau ntxiv cov khoom siv hluav taws xob hauv thaj chaw.

CATV Links

Cable TV tes hauj lwm siv PLC splitters los faib cov teeb liab video los ntawm headend mus rau ntau lub ntsiab lus.

Optical Signal Distribution

Tshaj li kev nkag tau mus rau hauv tes hauj lwm, PLC splitters yog siv nyob rau hauv qhov chaw xeem, lub tshuab sensing, thiab txhua daim ntawv thov uas ib tug optical teeb liab yuav tsum tau muab faib mus rau ntau qhov chaw.

info-2048-1142

Centralized vs. Distributed Splitting Architectures

Muaj ob txoj hauv kev los siv 1 × 32 splitters hauv FTTH network:

Centralized Spliting (Ib zaug -theem)

Ib qho 1 × 32 splitter yog ntsia rau ntawm qhov chaw nruab nrab- feem ntau yog lub txee rau txoj kev lossis lub hauv paus chaw ua haujlwm nws tus kheej. Feeder fibers khiav ncaj qha los ntawm lub splitter rau ib tus neeg rau npe. Qhov kev tsim qauv no yooj yim los tswj thiab muab qhov qis tshaj qhov poob, tab sis nws yuav tsum muaj fiber ntau feeder thiab tej zaum yuav nkim lub peev xwm yog tias tus neeg siv khoom noj - nce qis.

Kev faib tawm (ob-theem)

 

Splitting yog faib thoob plaws ob theem: piv txwv li, ib tug 1 × 4 splitter nyob rau hauv thawj theem thiab ib tug 1 × 8 splitter nyob rau hauv lub thib ob, ua tau ib tug sib npaug 1 × 32 phua ratio. Txoj hauv kev no siv cov khoom noj fiber ntau tsawg thiab tso cai rau kev nqis peev theem- koj nruab thawj theem pib thiab ntxiv thib ob -theem splitters raws li cov neeg siv npe. Txawm li cas los xij, qhov sib cais theem ntxiv ntxiv qhov poob thiab ua rau kom muaj pes tsawg lub teb.

Kev xaiv ntawm centralized thiab faib yog nyob ntawm cov neeg siv khoom ceev, thaj chaw, thiab lub sijhawm xa mus. Rau siab -cov cheeb tsam nroog ceev nrog ceev ceev- nce, centralized splitting nrog 1 × 32 feem ntau nyiam. Rau kev xa tawm mus nyob deb nroog lossis theem ntu, kev faib faib ua kom yooj yim dua.

 

Connector Options thiab Fiber Hom

 

Lub 1 × 32 PLC splitter yog muaj nrog ntau yam kev sib txuas thiab kev xaiv fiber ntau:

Connector Options:

• SC/APC (ntsuab, angled polish-pom zoo rau PON)

• SC / UPC (xiav, tiaj tus polish)

• LC/UPC (compact, rau siab - daim ntawv thov ceev)

• FC/UPC (xov, rau kev vibration-ib puag ncig)

• FC/APC

• ST/UPC

Fiber Options:

• 900µm xoob raj fiber ntau (rau splicing)

• 250µm liab qab fiber ntau (rau compact ntim)

• 2.0mm buffered fiber ntau (rau kev tiv thaiv ntxiv)

Rau feem ntau FTTH daim ntawv thov,SC/APC yog hom connector pom zoo. The angled physical contact (APC) polish provides superior return loss (>65dB), uas yog ib qho tseem ceeb rau PON systems uas qhov kev xav tuaj yeem cuam tshuam nrog cov teeb liab ntws.

CovG.657A1 fiber ntausiv nyob rau hauv no splitter yog khoov-insensitive, cia tighter khoov yam tsis muaj teeb liab poob-tseem ceeb rau installation nyob rau hauv cramped txee thiab faib lub thawv.

 

Installation Cov kev coj ua zoo tshaj plaws

 

Kev txhim kho kom zoo ua kom lub tshuab splitter ua tau raws li nws cov kev qhia tshwj xeeb rau xyoo:

1.Mount lub splitter ruaj ntseg:ABS lub thawv splitters tuaj yeem ntsia tau nrog cov ntsia hlau, nplaum, lossis cov hlua khi hauv cov khoom, qhov sib txuas kaw, lossis ODF thav ntawv.

2.Ntxuav tag nrho cov connectors:Ua ntej mating, ntxuav ob lub splitter connectors thiab mating cables nrog lint -dawb so thiab kho qhov muag tshuaj.

3.Kho qhov nkhaus nkhaus:Xyuas kom cov fibers raug xa mus nrog lub vojvoog khoov kom txaus-tsawg kawg 30 hli rau cov qauv fiber ntau, lossis cov chaw tsim khoom tau teev qhov tsawg kawg nkaus rau khoov- tsis muaj fiber ntau.

4.Label ports kom meej meej:Nrog 32 cov zis tawm, cov ntawv sau meej yog qhov tseem ceeb rau kev saib xyuas yav tom ntej.

5.Kuaj qhov txuas:Tom qab kev teeb tsa, txheeb xyuas qhov poob thiab rov qab poob ntawm txhua qhov chaw tso zis.

 

Kev Lag Luam Kev Lag Luam thiab Kev Loj Hlob

 

Kev lag luam optical splitter tau nthuav dav sai nrog rau kev xa tawm FTTH thoob ntiaj teb. Los ntawm nruab nrab-2026, ntau dua 700 lab FTTH / B cov neeg siv khoom tau txuas nrog thoob ntiaj teb. Lub ntiaj teb no PLC fiber ntau splitter kev ua lag luam raug nqi kwv yees li ntawm $ 1.615 nphom hauv 2025 ** thiab tau kwv yees tias yuav ncav cuag ** $ 2.307 billion los ntawm 2031, loj hlob ntawm CAGR ntawm 6.1%. Qhov dav dav passive optical splitter kev lag luam yog kwv yees li ntawm $ 4.844 billion hauv 2025 nrog CAGR ntawm 9.20%.

Qhov kev loj hlob no yog tsav los ntawm kev nthuav dav FTTH txuas ntxiv hauv cov lag luam tawm tshiab, 5G fronthaul kev xa tawm, thiab kev hloov kho ntawm PON networks uas twb muaj lawm rau XGS-PON thiab NG-PON2.

 

Yuav Ua Li Cas Xaiv Txoj Cai 1 × 32 PLC Splitter

Thaum xaiv 1 × 32 PLC splitter rau koj qhov project, xav txog cov yam ntxwv no:

1. Hom pob

• ABS Box: Feem ntau siv rau FTTH, haum rau hauv cov txee thiab kaw

• LGX Cassette: Rau khib- mount installations nyob rau hauv central chaw ua hauj lwm

• Steel Tube: Rau kev faus ncaj qha lossis hnyav ib puag ncig

• Bare Fiber: Rau kev koom ua ke rau hauv kev cai enclosures

2. Hom Connector

• SC/APC: Pom zoo rau PON tes hauj lwm (ntsuab, siab rov qab poob)

• SC / UPC: Haum rau kev siv dav dav (xiav)

• LC/UPC: Rau siab - ib puag ncig ceev

3. Fiber Ntev

Standard yog 1.5M input thiab tso zis. Kev cai ntev yog muaj rau cov kev xav tau tshwj xeeb.

4. Zoo thiab Warranty

Nrhiav cov neeg muag khoom nrog:

• Kev poob qis qis (tsawg dua lossis sib npaug rau 17dB siab tshaj plaws, qis dua yog qhov zoo dua)

• Kev poob siab rov qab (Ntau dua lossis sib npaug rau 55dB, Ntau dua lossis sib npaug rau 65dB rau APC)

• Cov ntaub ntawv pov thawj zoo

• Comprehensive warranty (xws li, 3-xyoo kev pab them nqi)

 

Xaus

 

1 × 32 PLC splitter yog ib qho tseem ceeb ntawm cov fiber ntau niaj hnub. Nws ua rau lub ntsiab lus -rau-multipoint architecture uas ua rau FTTH kev lag luam muaj txiaj ntsig, xa qhov sib npaug ntawm qhov ceev thiab qhov ua tau zoo kho qhov muag rau feem ntau cov xwm txheej xa tawm.

Nrog nws cov pob ABS compact, khoov-insensitive G.657A1 fiber ntau, thiab muaj zog -40℃mus rau 85℃kev khiav hauj lwm ntau yam, lub splitter no yog tsim los ua kom ntseeg tau nyob rau hauv lub xyoo. Txawm hais tias koj tab tom npaj ib qho tshiab FTTH rollout, nthuav lub PON network uas twb muaj lawm, los yog tsim lub CATV kev faib tawm, 1 × 32 PLC splitter tsim nyog qhov chaw hauv koj cov cuab yeej tsim.

Xa kev nug