Cov khoom sib txawv: PU vs PVC

Feem ntau cov qauv sab hauv tsev patch cords siv PVC (polyvinyl chloride) tsho. Nws yog pheej yig, hloov tau, thiab tsim nyog rau kev tswj hwm hauv tsev ib puag ncig zoo li cov chaw zov me nyuam, cov khoom siv chav, thiab chaw ua haujlwm cabling.

 

Sab nraum zoov thaj cords siv lwm yam nkaus. Lub OM3 sab nraum zoov qaum nta cov nplaim hluav taws-retardant, siab-toughness polyurethane (PU) elastomer sheath. Qhov no tsis yog qhov txawv ntawm kev lag luam - nws yog ib qho tseem ceeb ntawm cov khoom sib txawv nrog rau qhov tiag - ntiaj teb cuam tshuam.

 

PU Jacket muaj:

• Cov pa oxygen siab siab thiab cov nplaim hluav taws zoo heev - nws tiv thaiv hluav taws thiab tsis tuaj yeem tawm nplaim taws

• Roj thiab tshuaj tiv thaiv - qhov tseem ceeb rau kev lag luam ib puag ncig uas cov cables yuav raug rau cov kua dej hydraulic, cov kuab tshuaj, los yog lwm yam khoom corrosive

• Tear resistance - nws tiv taus lub cev puas thiab cov npoo ntse uas yuav ua rau PVC sai sai

• Tsawg-kub yooj yim - nws tseem pliable nyob rau hauv txias tej yam kev mob uas PVC ua nkig thiab tawg

• Kev ntxhov siab buffering thiab siab -resistant durability - nws absorbs txhua yam kev ntxhov siab uas yuav hloov mus rau cov fibers hauv qhov muag

Standard PVC tsis muaj cov khoom no. Nws yog qhov zoo rau kev tswj hwm ib puag ncig sab hauv tsev. Sab nraum zoov, nws yog lub luag haujlwm. Sab hauv PVC thaj cords tej zaum yuav muaj hnub nyoog, tawg, los yog tawv nyob rau hauv lub sij hawm ntev - raug tshav ntuj, ua rau lawv tsis haum rau kev siv sab nraum zoov tas li.

info-864-576

Qhov Sib txawv ntawm Cov Qauv: Ua kom Tau Txais Kev Sib Tw

Tus qauv sab hauv tsev patch cords muaj kev tsim kho yooj yim: fiber ntau, tsis muaj zog, cov tswv cuab lub zog (feem ntau aramid xov paj), thiab lub tsho. Lawv tau tsim los ua tib zoo saib xyuas hauv ib puag ncig tiv thaiv.

 

Sab nraum zoov thaj cords yog tsim txawv. OM3 sab nraum zoov qaum suav nrog ntau yam qauv uas ua rau nws muaj zog dua:

Aramid- txhawb nqa ib leeg-strand configurations muab lub cable nrog lub qhov rais dav tensile lim. Hauv lus Askiv dawb: koj tuaj yeem rub nws nyuaj dua yam tsis muaj kev puas tsuaj rau cov fibers hauv. Qhov no tseem ceeb thaum lub sij hawm installation los ntawm conduits, nyob ib ncig ntawm cov ces kaum, thiab hla cable tais - tag nrho cov kev khiav hauj lwm uas cuam tshuam cov cable rau mechanical stress.

 

Ib txheej txheej txheej tshwj xeeb thiab cov qauv sib xyaw thib ob nqus cov neeg kho tshuab thiab ib puag ncig kev ntxhov siab, txo qis ntxiv qhov muag cable poob. Standard patch cords tsis muaj cov txheej txheem tiv thaiv no. Thaum lawv khoov, rub, lossis raug kub hloov pauv, cov fibers muaj micro- dabtsi yog khoov uas ua rau cov teeb liab poob.

 

Me me - suab SZ-stranded optical fibers ua ke nrog aramid reinforcement muab lub qhov rais dav tensile strain. Qhov no txhais tau hais tias lub cable tuaj yeem ua haujlwm rov qab khoov thiab flexing yam tsis muaj degradation - ib qho tseem ceeb rau cov ntawv thov uas siv cov cables thiab rov thim rov qab dua.

 

Lub zog siab -rau- qhov hnyav piv thiab cov qauv me me puag ncig lub tsho ua rau lub teeb yuag rau nws lub zog thiab tsim nyog rau kev rov qab siv dua.

 

Tight-buffed xim coding ua raws li TIA-598-A tus qauv rau kev yooj yim fiber ntau routing thiab txiav. Qhov kev saib xyuas rau cov qauv no ua kom ntseeg tau tias txawm tias nyob rau hauv txoj kev xa tawm nyuaj, cov kws tshaj lij tuaj yeem txheeb xyuas sai thiab tswj tus kheej fibers.

 

Cov ntaub ntawv luam tawm cov khoom lag luam thiab cov cim ntev ntawm lub tsho cable muab kev qhia yooj yim - ib qho me me tab sis muaj txiaj ntsig zoo thaum koj tswj ntau ntau lossis ntau pua lub cables hauv kev xa tawm.

 

Qhov tshwm sim yog ib lub cable uas muaj peev xwm ciaj sia nyob rau hauv tej yam kev mob uas yuav sai sai rhuav tshem ib tug qauv nyob rau hauv tsev qaum. Qhov no tsis yog speculation - nws yog engineering.

 

Qhov txawv ntawm ib puag ncig: Dab tsi sab nraum zoov Cables tiag tiag ciaj sia

 

Standard indoor patch cords yog nyob rau hauv tsev siv. Qhov ntawd txhais tau hais tias tswj qhov kub thiab txias, tsis muaj dej raug, tsis muaj hluav taws xob UV, tsis muaj tshuaj lom neeg, thiab kev ntxhov siab ntawm lub cev tsawg. Lub OM3 sab nraum zoov thaj qaum yog ntsuas rau cov xwm txheej uas muaj qhov sib txawv:

Qhov kub thiab txias: OM3 sab nraum zoov qaum ua haujlwm los ntawm -20℃rau +70℃. Cov kab hluav taws xob sab hauv tsev feem ntau muaj qhov ua haujlwm nqaim (feem ntau 0℃rau +60℃) thiab tsis muaj qhov hloov pauv kub ntawm PU tsho.

 

Mechanical Strength: Lub cable muaj qhov tsawg kawg nkaus khoov vojvoog ntawm 248mm thaum lub sij hawm installation thiab 124mm thaum pw. Standard patch cords, tshwj xeeb tshaj yog cov uas muaj 2 hli los yog 3 hli lub tsho, muaj ntau nruj dua khoov vojvoog txwv thiab muaj kev cuam tshuam rau kev puas tsuaj los ntawm ntau tshaj - dabtsi yog khoov.

Pulling Force: Cov hlua sab nraum zoov tiv taus qhov siab tshaj plaws rub tawm ntawm 150N (15kg). Cov kab hluav taws xob sab hauv tsev feem ntau muaj qhov ntsuas qis dua, thiab dhau ntawm lawv ua rau micro-bending thiab teeb liab mus tas li degradation.

 

Cov kev pab rub tawm (42mm txoj kab uas hla) ntawm ob qhov kawg tso cai rau kev txhim kho yooj yim dua los ntawm cov kav dej thiab cov kab sib tw. Standard patch cords tsis muaj qhov tshwj xeeb no nkaus.

 

Kev ua tau zoo ntawm cov nplaim taws thiab cov pa luam yeeb: OM3 sab nraum zoov qaum lub tsho yog tsim los tsim cov pa luam yeeb tsawg heev thaum muaj hluav taws kub thiab tsis tawm cov pa phem -cov kua qaub sib xyaw lossis cov pa phem thaum raug nplaim taws. Thaum nyob sab hauv- cov kab hluav taws xob hauv tsev kuj tseem muaj qhov ntsuas hluav taws xob (xws li OFNR lossis LSZH), cov kab hluav taws xob sab nraum zoov feem ntau muab cov khoom muaj kev nyab xeeb nrog cov khoom siv dag zog uas xav tau rau qhov chaw sab nraud.

 

UV Resistance: Sab hauv PVC tsho degrade nyob rau hauv raug ultraviolet. Sab nraum zoov PU tsho yog tsim los tiv thaiv UV kev puas tsuaj, tswj lawv txoj kev ncaj ncees txawm tias tom qab lub hnub raug ntau xyoo.

 

Kev tiv thaiv dej thiab noo noo: Cov kab hluav taws xob sab hauv tsev tsis muaj qhov muaj txiaj ntsig tiv thaiv dej. Cov kab hluav taws xob sab nraum zoov yog tsim los tiv thaiv nag, av noo, thiab txawm tias nyob rau ib ntus - qhov tseem ceeb rau kev xa tawm sab nraum zoov.

 

Tensile Strength Comparison: Sab nraum zoov FTTA thaj cables feem ntau muaj ntau lub zog aramid cov tswv cuab lossis cov cuab yeej hlau, muab lawv lub zog tensile ntau dua li cov jumpers sab hauv. Qhov sib txawv no yuav tshwm sim tam sim ntawd thaum koj rub lub cable los ntawm cov kav dej - qaum sab nraum zoov yuav siv sij hawm; txoj hlua sab hauv tsev siv qhov kev puas tsuaj.

 

info-730-730

Daim ntawv thov tsis sib haum: Qhov chaw sab nraum zoov Cables tsis yog -Ngotiable

 

Standard indoor patch cords yog rau kev tswj ib puag ncig. Sab nraum zoov thaj qaum yog rau txhua yam. Daim ntawv thov OM3 sab nraum zoov qaum daim ntawv teev npe qhia txog thaj tsam ntawm qhov chaw nyob sab hauv tsev - cov kab hluav taws xob tsuas ua tsis tau:

 

Telecom & 5G (5G & LTE Infrastructure): FTTA kav hlau txais xov feeder cables, 4G LTE thiab 5G NR puag chaw nres tsheb, RRH-rau-RRU-rau-BBU CPRI txuas, me me ntawm tes sab nraum zoov xa tawm, thiab Tshaj Tawm Kav Hlau Kav (DAS). Cov no yog qhov chaw sab nraum zoov, qhov chaw uas cov cables yuav tsum tiv taus UV, qhov kub thiab txias, thiab huab cua. Txheem sab hauv tsev patch cords yuav degrade sai heev.

 

Industrial Networks (Smart Factory & Automation): Harsh-ib puag ncig lub Hoobkas hauv pem teb, neeg hlau thiab kev tswj kev sib txuas lus, sab nraum zoov muaj Ethernet, roj teb thiab kuv cov kev sib txuas lus, tshuaj lom neeg cog sensor tes hauj lwm. Cov cheeb tsam no cuam tshuam txog kev raug tshuaj lom neeg, kev puas tsuaj rau lub cev, thiab kev ntxhov siab ntawm cov khoom siv hluav taws xob uas cov kab hluav taws xob tsis tuaj yeem daws tau.

 

Tsheb thauj mus los & Ntse Lub Nroog (Infrastructure & Kev soj ntsuam): Kev saib xyuas kev tsheb, kev sib txuas lus hauv qhov chaw, txoj kev ITS units, sab nraum zoov PTZ video soj ntsuam, thiab lub nroog ntse sensor hubs. Cov no yog sab nraum zoov, nthuav tawm, feem ntau nyob deb qhov chaw uas tsis muaj cable txhais tau tias muaj kev cuam tshuam kev pabcuam thiab cov tsheb thauj khoom kim.

 

Lub Hom Phiaj Tseem Ceeb (Kev Tiv Thaiv & Kev Kub Ntxhov): Cov tub rog sib txuas lus, cov chaw hauv hiav txwv thiab ntug dej hiav txwv, kev sib tham thaum muaj xwm txheej ceev, chaw saib xyuas chaw taws teeb, thiab fiber ntau optic sensing systems. Cov no yog cov cheeb tsam uas tsis ua hauj lwm tsis yog ib qho kev xaiv - thiab qhov sib txawv ntawm ib sab hauv tsev - ntsuas qaum thiab sab nraum zoov - ntsuas qaum tuaj yeem ua lub luag haujlwm- tseem ceeb.

 

Field thiab thaiv ib ntus: OM3 sab nraum zoov qaum yog tsim tshwj xeeb rau cov ntawv thov thaiv ib ntus uas nws yuav raug xa mus thiab rov thim rov qab. Standard patch cords yuav sai sai poob nyob rau hauv rov qab tuav.

 

Qhov tshwm sim ntawm kev siv cov kab hluav taws xob sab hauv tsev sab nraum zoov tuaj yeem ua rau hnyav heev. Sab hauv cov hlua khi tsis muaj kev sib khi zoo thiab UV stabilization; lawv tuaj yeem ua tsis tiav hauv lub lis piam thaum raug huab cua. Ib lub cable uas tsis nyob hauv ib lub chaw khaws ntaub ntawv tuaj yeem hloov tau hauv feeb. Ib lub xov tooj uas ua tsis tau rau saum tus pej thuam, hauv qhov manhole, lossis ntawm qhov chaw ua haujlwm nyob deb yuav tsum muaj lub tsheb thauj khoom, tus kws tshaj lij, thiab muaj peev xwm nce siab - tus nqi uas deb tshaj qhov pib txuag ntawm kev xaiv cov kab pheej yig dua.

 

Sab Hauv Tsev vs. Sab Nraud: Ib qho piv txwv ncaj qha

 

Feature

Standard Indoor Patch Cord

OM3 Sab nraum zoov Patch Cord

Jacket Khoom

PVC

Nplaim taws-retardant, siab- tawv PU elastomer

UV Resistance

Tsis muaj

Zoo heev (PU tsho)

Kev tiv thaiv dej / noo noo

Tsis muaj

Huab cua-resistant, haum rau sab nraum zoov raug

Tensile zog

Tsawg

Siab (aramid reinforcement)

Rub qhov ntsuas

txwv

150N (15kg)

Yam tsawg kawg nkaus Khoov Radius (nruab)

Nws txawv (feem ntau nruj dua)

12 4mm

Qhov kub thiab txias

Nqaim (feem ntau yog 0℃rau +60 degree)

-20℃rau +70 degree

Roj/Chemical Resistance

pluag

Zoo heev

Tear Resistance

pluag

Zoo heev

Tsawg-Tsub Flexibility

Tsis zoo (PVC ua nkig)

Zoo heev

Pulling Aid

Tsis muaj

42mm txoj kab uas hla rub pab ntawm ob qho kawg

Nplaim/Smoke Performance

Ntau yam

Cov pa luam yeeb tsawg, cov pa phem tsawg tsawg

Rov ua dua Retractable siv

Tsis pom zoo

Tsim rau nws

 

Vim li cas qhov no tseem ceeb rau Network Kev Ntseeg

 

Network tsis ua haujlwm tsis tshua muaj tshwm sim los ntawm ib qho kev puas tsuaj loj. Ntau zaus, lawv yog qhov tshwm sim ntawm kev ua kom degradation - cable uas "zoo txaus" rau ib puag ncig maj mam poob kev ua haujlwm kom txog rau thaum ib hnub, nws tsis ua haujlwm.

 

Cov kab hluav taws xob hauv tsev siv sab nraum zoov tsis ua li no. Lub tsho tawg los ntawm kev raug UV. Cov dej noo nkag mus rau hauv thiab ua rau poob hydrogen. Kev kub ceev caij tsheb kauj vab ua rau PVC nkig. Tus kws tshaj lij rub me ntsis nyuaj thaum lub sijhawm tu thiab fiber ntau so.

 

Sab nraum zoov cables yog tsim los tiv thaiv no cumulative degradation. Lub tsho PU tsis tawg. Lub aramid reinforcement tuav lub zog rub. Txheej txheej tshwj xeeb absorbs mechanical stress. Qhov tshwm sim yog lub cable uas tswj nws qhov kev ua haujlwm kho qhov muag txhua xyoo, txawm tias nyob rau hauv cov xwm txheej nyuaj.

 

Qhov no yog qhov tseem ceeb tshwj xeeb hauv cov ntawv thov uas nkag tau yooj yim. Ib lub xov tooj ntawm tus pej thuam saum toj kawg nkaus, hauv ib lub qhov, lossis ntawm qhov chaw ua haujlwm nyob deb tsis yooj yim los hloov. Tus nqi ntawm lub tsheb thauj khoom, tus kws tshaj lij, thiab muaj peev xwm nce siab tshaj qhov sib txawv ntawm tus nqi hauv tsev thiab sab nraum zoov. Kev nqis peev hauv txoj cai cable los ntawm qhov pib tsis yog kev siv nyiaj - nws yog txoj cai pov hwm tiv thaiv kev cuam tshuam kev pabcuam yav tom ntej.

 

Cov kab hauv qab: Nws tsis yog ib lub tsho tuab xwb

 

Sab nraum zoov fiber ntau thaj qaum tsis yog ib qho hlua sab hauv tsev nrog cov txheej tuab ntawm cov yas. Nws yog ib yam khoom sib txawv - cov ntaub ntawv sib txawv, kev tsim kho sib txawv, cov yam ntxwv sib txawv.

 

Lub OM3 sab nraum zoov thaj qaum los ntawm GLORY Optical qhia qhov txawv qhov zoo li hauv kev xyaum: PU tsho rau cov tshuaj tiv thaiv thiab qis - qhov kub thiab txias, aramid reinforcement rau tensile lub zog, coatings tshwj xeeb rau kev ntxhov siab, thiab cov qauv tsim uas tso cai rau rov xa rov qab xa thiab thim rov qab. Nws yog tsim rau ib puag ncig uas tus qauv cords yooj yim mus tsis tau.

 

Yog tias koj siv cov fiber ntau hauv ib puag ncig sab hauv tsev, cov kab hluav taws xob ua haujlwm zoo. Yog tias koj siv fiber ntau sab nraum zoov, hauv ib puag ncig kev lag luam, lossis txhua qhov chaw uas cov hlua khi yuav raug kev nyuaj siab, huab cua, lossis tshuaj lom neeg - koj xav tau ib lub hlua sab nraum zoov. Qhov txawv tsis yog hloov maj mam. Nws yog qhov sib txawv ntawm lub network uas kav ntev thiab lub network tsis ua haujlwm.

Xa kev nug