Peb tus lej uas txhais tau tias lub thawv fiber ntau lub peev xwm
Cov ntaub ntawv khaws cia cov ntaub ntawv teev cov thawv fiber ntau los ntawm cov chaw nres nkoj suav: 8-port, 24-port, 48-port. Tus lej ntawd piav qhia tsuas yog ib qho ntawm peb txoj kev muaj peev xwm ywj pheej. Nyob ntawm seb dab tsi mus rau hauv - adapters, splice trays, PLC splitters - koj tuaj yeem ntaus ib qho ntawm ob qhov txwv nrog cov chaw nres nkoj vaj huam sib luag tseem tsis tau siv.
1. Adapter chaw nres nkoj suav
Qhov no yog tus lej luam tawm ntawm daim ntawv lo thiab siv rau hauv cov ntaub ntawv kev yuav khoom: 4, 8, 12, 16, 24, 48, 96. Nws suav cov SC/APC lossis LC adapter sockets nyob rau pem hauv ntej lossis lub ntsej muag vaj huam sib luag ntawm cov ntaub thaiv npog - cov chaw nres nkoj lub cev uas muaj fiber ntau thaj cords lossis pre{droops txuas rau ib tus neeg ua ntej. ua ntej- txiav cables thiab yeej tsis muaj splices hauv lub thawv yuav tsoo qhov txwv no ua ntej. RauFastConnect- hom FTTH faib lub thawvuas siv lub Hoobkas- txiav tawm SC/APC cov zis, suav qhov chaw nres nkoj tsuas yog tus lej muaj peev xwm xwb.
2. Splice tais muaj peev xwm
Qhov no yog tus naj npawb ntawm cov fiber ntau fusion splices lub thawv tuaj yeem ruaj ntseg hauv tsev, tiv thaiv hauv tshav kub-shrink tes tsho thiab tuav hauv cov tais uas tshem tau. Hauv cov thawv txiav tawm uas sib txuas nrog cov khoom sib txuas nrog cov khoom sib txuas - qhov kev teeb tsa ntau tshaj plaws hauv FTTH xa tawm - splice tais txwv feem ntau khi ua ntej lub chaw nres nkoj puv. Standard splice tais tuav 12 los yog 24 ib leeg -fiber splices. Ib lub thawv uas tau tshaj tawm tias "16 qhov chaw nres nkoj" tuaj yeem xa nrog ib lub tais 12-fiber, txhais tau hais tias nws lub cev tsis tuaj yeem tuav 16 qhov huv si yam tsis muaj kev quab yuam nruj thiab ua txhaum qhov tsawg kawg nkaus khoov vojvoog.
3. Internal routing thiab splitter qhov chaw
Lub ntim sab hauv uas siv tau tom qab cov kab txuas txuas, lim-cov clamps nyem, thiab cov splice phaj pawg nyob rau hauv qhov chaw. Hauv cov phab ntsa compact-mount termination boxes, tag nrho 1 × 16 PLC splitter cassette tuaj yeem haus 30-40% ntawm cov kab noj hniav sab hauv, tawm hauv chav tsis txaus rau txoj kev pigtails yam tsis muaj micro- dabtsi yog khoov. Nyob rau sab nraum zoov enclosures, IP68 cable caj pas thiab grounding terminals ntxiv txo qhov chaw muaj rau kev tswj fiber ntau. CovFAT thiab ONT xaiv phau ntawv qhiahais txog qhov kev sib pauv no kom ntxaws rau cov neeg siv khoom - cov ntsiab lus txiav tawm sab.
Qhov laj thawj feem ntau ntawm cov tsheb thauj khoom tsis tau teem caij hauv FTTH tsim yog qhov chaw nres nkoj - suav / splice- tais tsis sib haum - tshwj xeeb, cov thawv tau lees tias yog 16 lossis 24 qhov chaw nres nkoj tab sis xa nrog ib qho 12-fiber tais. Tus kws tshaj lij pom pom ntawm splice 13, ntawm tus ncej, hauv nag. Kev suav cov tais ntim thiab lub tais ntim nrog cov chaw nres nkoj suav tshem tawm cov chav kawm ntawm kev rov ua haujlwm tag nrho.
Standard fiber ntau lub thawv: 4-chaw nres nkoj rau 144-core ntawm ib nrais muag
Fiber thawv poob rau hauv plaub lub peev xwm tiers. Kev sib tw qib rau cov txheej txheem network zam hauv qab - tsim ntawm cov ntsiab lus faib khoom thiab them nyiaj tshaj ntawm qhov poob.
Fiber box muaj peev xwm sib piv - raug configurations los ntawm tier. Tus nqi tiag tiag txawv ntawm cov chaw tsim khoom thiab cov qauv; ib txwm txheeb xyuas cov ntaub ntawv ua ntej xaj.
| Lub thawv hom / tier | Adapter chaw nres nkoj | Splice tais | Max splices | Splitter qhov | Tej daim ntawv thov |
|---|---|---|---|---|---|
| 2-4 port termination box | 2–4 | 0-1 (12- fiber ntau) | 0–12 | Tsis muaj los yog mini | FTTH chaw nyob poob, ONT- sab |
| 8 chaw nres nkoj termination box | 8 | 1 (12-24 fiber ntau) | 12–24 | 1 × 4 los yog 1 × 8 mini PLC | Ib leeg-tsev neeg pawg, villa |
| 12-16 port termination box | 12–16 | 1-2 (12-24 fiber ntau) | 24–48 | 1 × 8 los yog 1 × 16 | Me MDU, SME pem teb |
| 24 chaw nres nkoj faib lub thawv | 24 | 2 (24 fiber ntau txhua) | 48 | 1 × 16 los yog 1 × 32 | Medium MDU, NAP / FAT point |
| 48 chaw nres nkoj faib lub thawv | 48 | 4 (24 fiber ntau) | 96 | 1 × 32 (ib los yog ob) | Loj MDU, sab nraum zoov NAP/FAT |
| 96 chaw nres nkoj enclosure / ODF | 96 | 4-6 (24 fiber ntau) | 96–144 | Ntau 1 × 32 | CTO / DPU / faib txee |
| 144-core splice kaw | 0 (splice-tsuas yog) | 6 (24 fiber ntau) | 144 | Tsis siv tau | Feeder / qaum, faus los yog dav hlau |
| 288-core inline kaw | 0 (splice-tsuas yog) | 12 (24 fiber ntau) | 288 | Tsis siv tau | Metro nraub qaum, siab - suav feeder |
Splice tais muaj peev xwm: tus naj npawb buyers feem ntau nco
Lub tais splice yog cov yas tshem tau los yog txhuas ntxig rau hauv lub thawv fiber ntau uas tuav ib tus neeg fusion splices nyob rau hauv tshav kub-shrink tiv thaiv tes tsho. Lub tais khaws txhua qhov sib txuas tsis txav, tswj qhov khoov lub vojvoog kom raug rau cov fiber ntau tawm hauv cov splice, thiab tso cai rau tus kws tshaj lij nkag mus rau ib lub tais yam tsis muaj kev cuam tshuam rau lwm tus. Txhua fiber ntau uas yog spliced nyob rau hauv lub thawv - seb nws yog ib tug feeder pigtail, ib tug subscriber poob, los yog ib tug splitter pigtail - occupies ib txoj hauj lwm nyob rau hauv ib tug splice tais.
12-fiber vs 24-fiber tais: cov spec koj xav tau kom paub meej
Ob lub tais loj tshaj plaws tuav 12 lossis 24 ib zaug -fiber fusion splices. Qhov sib txawv suab yooj yim, tab sis nws muaj cov txiaj ntsig zoo. A 48-chaw nres nkoj txiav lub thawv nruab nrog ob lub 24-fiber trays muaj peev xwm splice ntawm 48 - txaus kom phim txhua qhov chaw nres nkoj rau ib qho kev sib tshuam. Tib lub thawv nruab nrog ob lub 12-fiber trays muaj peev xwm splice tsuas yog 24, ib nrab ntawm cov chaw nres nkoj suav. Txij li feem ntau fiber ntau lub thawv datasheets sau cov adapter ports prominently thiab tais cov ntsiab lus faus nyob rau hauv ib tug seem spec, buyers ib txwm nrhiav qhov tsis sib haum ntawm qhov chaw.
Thaum thov cov lus hais rau lub thawv txiav, ib txwm nug peb lo lus nug meej meej: (1) Lub thawv ntim khoom xa tuaj nrog pes tsawg? (2) Lub peev xwm ntawm txhua lub tais - 12 lossis 24 fibers yog dab tsi? (3) Dab tsi yog qhov ntau tshaj ntawm cov tais hauv lub thawv tuaj yeem tuav yog tias koj ntxiv ntxiv? Ib lub thawv nrog ob 24-fiber trays ntsia tab sis chav rau plaub txhais tau tias koj muaj 48 splices hnub no thiab 96 tag kis yam tsis tau yuav ib lub thawv tshiab.
Mass fusion splice tais
Siab - suav cov pob txha pob txha qee zaum siv cov khoom loj- fusion tais uas tuav 12-fiber los yog 24-fiber ribbon splices nyob rau hauv ib txoj hauj lwm, muab cov fiber ntau suav rau ib lub tais los ntawm 12 los yog 24. A 144-cov tub ntxhais dome kaw tuaj yeem tiv thaiv 1 ris 144 tus neeg fiber ntau splices - los yog, nrog ribbon cable, tib lub cev lub tais qhov chaw tiv thaiv 144 fibers spliced nyob rau hauv ribbon pawg ntawm 12. Yog hais tias koj feeder cable yog ribbon fiber (feem ntau nyob rau hauv high-count campus los yog metro cog), paub meej tias lub thawv lub tais yog ribbon-tshaj ua ntej xaj.
Qhov chaw nres nkoj-vs- tais tsis sib haum
Qhov kev puas tsuaj loj tshaj plaws yog lub thawv nrog ntau qhov chaw nres nkoj adapter dua li txoj haujlwm splice. A 24-chaw nres nkoj lub ntsej muag phaj nruab nrog ib qho 12- fiber ntau tais tuaj yeem nthuav tawm 24 txuas mus rau lub ntiaj teb sab nraud tab sis lub cev tsis tuaj yeem tuav 24 qhov tiv thaiv sab hauv. Thaum lub tais ntim rau ntawm 12 splices, qhov seem 12 pigtails yuav tsum tau muab tso tseg tsis muaj kev tiv thaiv, coiled unsupported, los yog lub thawv yuav tsum tau rov qhib dua thiab ib tug thib ob lub tais - piv txwv li lub enclosure muaj chav. Ntawm ib qhov project uas nkag tau yooj yim (ncej mount, underground, sab nrauv phab ntsa), qhov no txhais tau hais tias ib tug unscheduled tsheb yob.
Breakout ratio thiab splitter slot Planning
HauvPONKev xa tawm, lub thawv xa khoom muaj PLC splitter uas faib ib qho khoom xa tuaj rau hauv ntau cov neeg siv khoom tawm. Qhov sib cais (1 × 4 mus rau 1 × 32) ncaj qha txiav mus rau hauv lub peev xwm siv tau nyob rau hauv txoj kev feem ntau cov nplooj ntawv spec tsis nto.
Yuav ua li cas PLC splitter module siv lub ntim sab hauv
Ib tug liab qab 1 × 16 PLC splitter module yog me me: roughly 40 × 4 × 4 mm. Cassette- ntim, nws dhau los ua kwv yees li 100 × 75 × 12 hli, ntxiv rau txoj kab hluav taws xob rau 16 cov zis pigtails. Nyob rau hauv lub compact 16-chaw nres nkoj tis lub thawv, lub cassette siv kwv yees li ib nrab ntawm lub sab hauv pem teb cheeb tsam, tawm hauv lub 16 pigtails mus txog rau lub adapter phaj nyob rau hauv lub 30 hli ib leeg-hom khoov vojvoog yam tsawg kawg nkaus.
Xam cov neeg siv khoom tiag tiag tso zis muaj peev xwm
Plaub qhov sib txawv txiav txim siab lub thawv loj:
- Suav cov feeder fibers.Ib lub feeder fiber pub ib PLC splitter module. Ob lub feeder fibers pub ob lub PLC splitters, ua ob npaug ntawm cov khoom tso tawm.
- Muab faib ua piv txwv.1 feeder × 1 × 16 phua=16 muaj peev xwm tso tawm cov neeg siv khoom tawm. 2 feeders × 1 × 16=32 cov khoom muaj peev xwm.
- Txheeb xyuas qhov chaw nres nkoj adapter suav.Cov zis suav los ntawm kauj ruam 2 yuav tsum tsis pub tshaj tus naj npawb ntawm lub cev adapter chaw nres nkoj ntawm lub ntsej muag phaj.
- Txheeb xyuas qhov chaw splice tais.Txhua PLC splitter muaj ib lub tswv yim pigtail (ib qho splice) thiab N tso tawm pigtails (N splices). 1 × 16 module yuav tsum muaj 17 splice txoj haujlwm hauv lub tais. Ib lub thawv nrog ob lub 1 × 16 modules xav tau 34 splice txoj haujlwm - ob daim ntawv puv 24-fiber trays rho tawm 14 txoj haujlwm tsis siv, lossis peb 12-fiber tais.
| Splitter configuration | Subscriber outputs | Splice txoj hauj lwm xav tau | Yam tsawg kawg nkaus config |
|---|---|---|---|
| 1 × (1 × 8) PLC | 8 | 9 (1 hauv + 8 tawm) | 1 × 12-fiber tais |
| 1 × (1 × 16) PLC | 16 | 17 | 1 × 24-fiber tais |
| 2 × (1 × 16) PLC | 32 | 34 | 2 × 24-fiber tais |
| 1 × (1 × 32) PLC | 32 | 33 | 2 × 24-fiber tais (los yog 3 × 12) |
| 2 × (1 × 32) PLC | 64 | 66 | 3 × 24-fiber tais |
| 3 × (1 × 32) PLC | 96 | 99 | 5 × 24-fiber tais |
A 96-chaw nres nkoj enclosure khiav peb 1 × 32 PLC splitters xav tau yam tsawg kawg yog tsib 24-fiber trays - ib lub thawv shipping nrog ob los yog peb lub tais yuav khiav luv ua ntej cov splitters txuas.
Sab hauv thiab sab nraum lub thawv muaj peev xwm: vim li cas ib puag ncig hloov txhua yam
Ob lub thawv uas suav nrog cov chaw nres nkoj zoo ib yam tuaj yeem muaj qhov sib txawv ntawm qhov muaj peev xwm siv tau sab hauv ib zaug hauv cov qog, lim- cov khoom siv kho mob nyem, thiab cov tais ntim khoom sib txuas. Qhov txawv raws li ncaj qha los ntawm qhov kev sib khi sab nraum zoov lub cev xav tau.
IP ntsuam xyuas thiab siv tau qhov chaw sab hauv
IP68- ntsuas lub thawv yuav tsum kaw txhua qhov chaw nkag cable nrog lub caj pas compression uas protrudes 15-30 mm rau sab hauv. Hauv ib lub thawv ntim 8-chaw nres nkoj nrog plaub qhov chaw nres nkoj, cov qog no haus 15-20% ntawm cov ntim sab hauv ua ntej ib qho fiber ntau raug xa mus. Ntxiv strain-relief clamps thiab thaj chaw siv tau hauv pem teb nyob ze ntawm qhov chaw nkag cable shrinks ntxiv. Ib qhov loj 48-chaw nres nkoj enclosure nrog yim cable ports pom qhov feem pua me me, tab sis qhov kev txwv qhov chaw nyob ze ntawm qhov nkag tseem muaj tiag.
Splice tiv thaiv lub tes tsho nyob rau hauv sab nraum zoov enclosures
Thaum tshav kub kub -shrink splice tes tsho (60 mm × 3 mm tom qab shrinking) yuav tsum tau zaum tag nrho nyob rau hauv lub tais tuav rau sab nraum zoov enclosures cycling ntawm −40℃thiab +60℃. Cov seem uas tsis muaj kev txhawb nqa flex nyob rau hauv thermal expansion thiab tuaj yeem tsim micro- dabtsi yog khoov poob ntau zaus. Cov thawv sab hauv tsev, nrog lawv qhov ntsuas qhov ntsuas qhov nqaim, zam cov ntim ntim rau hauv tib lub tais hneev taw.
Thermal cycling thiab splice suav raws sijhawm
Txhua qhov fusion splice nyob rau hauv ib qho chaw sab nraum zoov muaj kev ntxhov siab txhua lub sij hawm lub qhov rooj nthuav dav thiab cog lus nrog qhov kub thiab txias. Lub splice tiv thaiv los ntawm cov cua sov uas tau muab tso rau kom zoo- lub tes tsho ntsws, clamped ruaj ntseg hauv lub tais, thiab ua haujlwm nrog lub voj voog slack txaus yog ruaj khov rau ntau xyoo ntawm kev caij tsheb kauj vab.
Ib qho splice uas dhau - ntim - kov lub tes tsho uas nyob ib sab, nrog tsis txaus slack - tuaj yeem tsim micro- dabtsi yog khoov poob ntawm tus nqi ntawm 0.02–0.05 dB ib xyoos nyob rau hauv kev rov ua dua. Qhov degradation no tsis pom ntawm commissioning thiab tshwm sim maj mam raws li lub hnub nyoog network. Qhov kev cuam tshuam zoo yog kev saib xyuas sab nraum zoov splice ntom ntom: sau splice trays rau 80% ntawm qhov muaj peev xwm nyob hauv kev teeb tsa sab nraum zoov, tawm hauv 20% headroom rau thermal expansion ntawm cov khoom slack.
Yuav ua li cas xam cov fiber ntau koj xav tau tiag tiag
Tsib inputs txiav txim seb lub thawv twg haum: cov neeg suav (tam sim no thiab 5-xyoo), sib faib piv, network topology, expansion headroom, thiab installation ib puag ncig.
Ntxiv 30–50% rau hnub no suav rau 5- xyoo kwv yees. Kev xa tawm FTTH tsis tshua hloov cov ntaub thaiv ib nrab ntawm -lub neej; sizing rau ib hnub-ib qho kev thov thiab nrhiav pom koj xav tau lub thawv thib ob hauv xyoo peb tus nqi ntau dua li kev yuav qhov loj me tom ntej pib.
Faib cov neeg siv khoom xav tau suav los ntawm koj xaiv qhov sib faib (feem ntau 1 × 8, 1 × 16, lossis 1 × 32) txhawm rau nrhiav cov lej ntawm PLC xav tau. Hloov mus rau tag nrho cov splitter tom ntej. Ib tug 28-subscriber node ntawm 1 × 16 splits xav tau ob 1 × 16 modules (32 outputs, 4 spare).
Cov neeg suav suav (kwv yees) + feeder fiber ntau + cov chaw nres nkoj (tsawg kawg 10%). Qhov no muab koj lub adapter chaw nres nkoj suav pem teb. Hloov mus rau qhov loj me (8, 12, 16, 24, 48).
Siv cov qauv: splice txoj hauj lwm xav tau=(ntau ntawm PLC modules × (split ratio + 1)) + tus naj npawb ntawm pass-los ntawm los yog qhia splices + 20% margin. Paub meej tias lub thawv muaj lub tais lub cev txaus los tuav cov suav no, thiab txhua lub tais tuav 24 (tsis yog 12) fibers tshwj tsis yog koj tau lees paub lwm yam.
Nug tus neeg muag khoom rau cov kab noj hniav hauv qhov ntev thiab paub meej tias koj lub PLC cassette lub cev haum nrog cov splice trays nrog tsawg kawg 30 mm khoov vojvoog clearance rau tag nrho cov pigtails. Qhov no yog cov kauj ruam uas tiv thaiv qhov ntawm - qhov chaw nrhiav pom tias txhua yam haum rau txoj kev xav tab sis tsis yog hauv kev xyaum.
Scenario:38-unit tsev apartment, GPON network, 1 × 16 phua ib pem teb, 4 pem teb, sab nraum zoov txoj kev hauv tsev installation.
Cov neeg yuav khoom suav:38 hnub no, 50 npaj ntawm 5 xyoo (ntxiv 32% headroom).
PLC modules:50 ÷ 16=3.125 → 4 modules ntawm 1 × 16 (64 outputs, 14 spare).
Adapter ports xav tau:64 tus neeg siv khoom + 2 feeder input + 6 spare=72 → xaiv 96-chaw nres nkoj enclosure.
Splice txoj haujlwm xav tau:4 modules × 17 txoj haujlwm=68 + 10% margin=75 → 4 × 24-fiber tais (96 txoj haujlwm).
Qhov tshwm sim:96-chaw nres nkoj sab nraum zoov nrog 4 × 24-fiber tais thiab ntim sab hauv rau 4 × 1 × 16 PLC cassettes. Lub thawv 48-chaw nres nkoj yuav sau tam sim; ib lub thawv 96-chaw nres nkoj muab tag nrho chav kom loj hlob.
5 kev yuav khoom yuam kev uas ua rau cov neeg yuav khoom luv luv ntawm lub peev xwm
Glory Optical fiber ntau lub thawv: muaj peev xwm ntawm ib nrais muag
Cov lus hauv qab no qhia txog Glory Optical thawj cov tsev neeg nyob rau hauv lawv lub peev xwm specs, nrog rau cov ntawv txuas rau cov ntaub ntawv thiab OEM customization xaiv.
| Tsev neeg khoom | Chaw nres nkoj / fiber ntau suav | Splice tais | Kev ntsuas IP | Thawj daim ntawv thov |
|---|---|---|---|---|
| GL-P2 series - Termination Box | 4, 8 ports | 1 × 12-fiber | IP65/66 | Qhov chaw nyob FTTH poob, ONT- sab |
| GL-P1 series - Distribution Box | 12, 16, 24 ports | 1-2 × 24-fiber | IP65 | MDU pem teb, SME, me NAP |
| GL-ODB-16R - Optical Distribution Box | 16 chaw nres nkoj SC / APC | Tig- qhib splice tais (pigtail cia) | IP68, IK10 | Sab nraum zoov FAT/NAP, GPON/XGS-PON |
| GL-A9-48R - Sab nraum zoov Distribution Enclosure | 48 ports | 4 × 24-fiber | IP65/66 | Loj MDU, sab nraum zoov NAP/FAT, CTO |
| GL-H series - Kab rov tav Splice Kaw | 48, 96, 144 cores (splice-tsuas yog) | 2-6 × 24-fiber | IP68 | Aerial/duct inline splice, feeder cable |
| GL-5601 - Dome Splice Kaw | 144 cores ib leeg / 432 cores ribbon | 6 × 24 - fiber ntau (ribbon-muaj peev xwm) | IP68 | Rov qab, faus feeder, aerial, metro |
Sab nraum zoov cov ntaub ntawv raug ntaus nqi IK09/IK10 rau ncej-mounted xa tawm. Lub GL-ODB-16R lees txais daim teb- hloov tau 1 × 4, 1 × 8, thiab 1 × 16 PLC cassettes - cov kev sib txuas uas twb muaj lawm nyob twj ywm nyob rau lub sijhawm sib pauv sib pauv, uas tseem ceeb ntawm cov txheej txheem theem uas tus nqi nce tom qab pib tsim.
Cov qauv thiab yam lawv lav txog fiber ntau lub thawv muaj peev xwm
Kev sim rau cov qauv no txhais tau tias muaj sia nyob nrawm dua - kev laus thiab kev ntxhov siab ib puag ncig - tsis yog ua raws li qhov loj me lossis qhov chaw nres nkoj - suav cov lus qhia.
- ITU-T L.100npog optical fiber cables thiab passive optical Cheebtsam nyob rau hauv cov nqe lus ntawm ib puag ncig haum thiab mechanical kev ua tau zoo yuav tsum tau rau sab nraum cog xa mus. Nws teeb tsa lub moj khaum nyob rau hauv uas FOSC thiab faib lub thawv ib puag ncig kev ntsuas raug ntsuas.
- Telcordia GR-771(Generic Requirements for Fiber Optic Splice Closures) txhais cov kev xeem ib puag ncig, tshuab, thiab sealing tsim nyog rau kev sib txuas sab nraum zoov - tus qauv uas ua rau IP68 lub ntsiab lus tshwj xeeb es tsis yog kev thov kev lag luam. Cov thawv uas tau sim tawm tsam GR-771 tau pom tias lawv cov kev sib khi ua haujlwm tau zoo nyob rau hauv thermal cycling (−40℃rau +70} degree), pressurized-dej immersion, vibration, thiab compression.
- IEC 61753-1: Covtxhais cov kev cai dav dav thiab cov qauv kev sim rau cov khoom siv kho qhov muag tsis pom kev nyob rau hauv ntau yam ntawm ib puag ncig pawg - los ntawm qhov chaw nyob sab hauv tsev (qeb U) mus rau qhov hnyav sab nraum zoov thiab hauv av (qeb O thiab E). Lub thawv fiber ntau tus IP thiab ntsuas qhov ntsuas kub tuaj yeem hla - hais tawm tsam IEC qeb kom paub meej tias tsim nyog rau thaj chaw xa khoom npaj.
- Lub koom haum Fiber Optic (FOA)Tshaj tawm cov lus qhia ua tau zoo ntawm kev xaiv cov ntaub thaiv npog, sib txuas cov kev coj ua zoo tshaj plaws, thiab kev npaj peev txheej uas ntxiv cov qauv kev cai nrog rau daim teb - tau txais cov lus pom zoo, suav nrog cov kev taw qhia ntawm qhov tsawg kawg nkaus txoj kab hluav taws xob tswj hwm hauv cov ntaub thaiv npog thiab splice tray loading txwv.
Glory Optical tsim cov thawv fiber ntau rau IEC 61753-1 pawg ib puag ncig, ua pov thawj IP ntsuas tiv thaiv IEC 60529, thiab kuaj cov ntaub thaiv sab nraum zoov kom ua raws li cov txheej txheem tsim nyog ib puag ncig ntawm Telcordia GR-771 hauv tsev ua ntej tso tawm batch.
Cov lus nug uas nquag nug
-
Q: Muaj pes tsawg fibers tuaj yeem ua tus txheej txheem fiber ntau txiav lub thawv tuav?
A: Nws nyob ntawm qib. Lub thawv 4–8 chaw nres nkoj nyob hauv qhov chaw txiav tawm feem ntau tuav 4–24 tus neeg fibers (chaw nres nkoj rau kev sib txuas sib txuas ntxiv rau 12- lossis 24-fiber splice tais). Lub 24-chaw nres nkoj MDU lub thawv ntim khoom tuav txog 24 cov khoom sib txuas thiab 48 splices (ob lub tais 24-fiber). 144-core sab nraum zoov splice kaw tuav 144 tus neeg fiber ntau splices nyob rau hauv rau 24-fiber tais tab sis tsis muaj connectorized ports - nws yog ib tug splice-tsuas enclosure. Cov lus teb luv luv yog: qhov chaw nres nkoj suav thiab suav suav yog cais tus lej thiab ob qho tib si yuav tsum tau teev tseg.
Q: Dab tsi yog qhov txawv ntawm lub thawv fiber ntau txiav thiab kaw fiber ntau splice?
A: Lub thawv fiber ntau txiav (tseem hu ua lub thawv fiber ntau lub thawv lossis lub thawv kho qhov muag) yog lub thawv ntim khoom sib txuas uas muab cov chaw txuas txuas txuas rau sab nraud rau thaj chaw sib txuas, ntxiv rau lub tais splice sab hauv rau cov pigtail - rau - feeder fiber splices. Fiber splice kaw yog ib lub kaw kaw rau fusion splices nkaus xwb - nws tsis muaj lwm qhov chaw nres nkoj adapter thiab yog siv los tiv thaiv cable-rau- cable splices nyob rau sab nraum zoov lossis hauv av. Qhov kev xaiv nyob ntawm seb qhov chaw xav tau kev sib txuas (lub thawv txiav tawm) lossis yog nruab nrab -span splice point uas tsis muaj kev sib txuas ntawm cov neeg siv ntawm qhov no (splice kaw).
Q: Muaj pes tsawg tus neeg siv khoom tuaj yeem ua 16-chaw nres nkoj fiber ntau faib lub thawv pab?
A: Txog li 16 tus neeg yuav khoom - ib qho ntawm qhov tso zis adapter chaw nres nkoj. Yog tias lub thawv muaj 1 × 16 PLC splitter, ib qho khoom noj fiber ntau nkag mus thiab 16 tus neeg siv khoom poob cables tawm. Yog tias lub thawv muaj cov pigtail ncaj qha -rau- cov neeg siv khoom txiav tawm yam tsis muaj kev sib cais, txhua qhov ntawm 16 qhov chaw nres nkoj txuas mus rau cov khoom noj fiber ntau thiab ib tus neeg siv khoom. Lub splitter{11}}raws li configuration yog ib yam nyob rau hauv FTTH tes hauj lwm; qhov ncaj qha- kev txiav tawm kev teeb tsa yog ib txwm nyob hauv tsev kawm ntawv lossis chaw lag luam Ethernet- dhau- cov pob txha fiber ntau.
Q: Vim li cas 144-core fiber ntau lub thawv qee zaum txhais tau tias 144 splices thiab qee zaum 144 chaw nres nkoj?
A: Vim tias "144-core" piav qhia txog fiber ntau suav, tsis yog qhov ua haujlwm. Nyob rau hauv 144-core dome splice kaw, tag nrho 144 fibers yog spliced nyob rau hauv lub enclosure thiab tsis muaj chaw nres nkoj tau nthuav tawm sab nraud. Hauv 144-chaw nres nkoj ODF (optical faib thav duab), 144 qhov chaw nres nkoj adapter tau nthuav tawm ntawm lub vaj huam sib luag pem hauv ntej thiab 144 qhov sib txuam pigtails yog spliced hauv. Cov khoom lag luam (kaw vs ODF) qhia koj txoj haujlwm; cov suav fiber ntau qhia koj lub peev xwm. Nco ntsoov lees paub ob qho tib si ua ntej xaj.
Q: Dab tsi yog qhov tsawg kawg nkaus khoov vojvoog hauv lub thawv fiber ntau, thiab vim li cas nws tseem ceeb?
A: Rau tus qauv ib zaug - hom fiber ntau (G.652.D), lub dynamic khoov vojvoog - lub vojvoog thaum lub sij hawm installation thiab routing - yog 30 hli. Lub vojvoog khoov zoo li qub - lub vojvoog nyob rau hauv uas fiber ntau tuaj yeem tawm mus tas li - kuj yog 30 hli rau tus qauv SMF raws li G.657.A1 specifications. Tshiab khoov-insensitive fiber ntau (G.657.A2 lossis B2) muaj qhov nkhaus zoo li qub ntawm 7.5-15 hli. Routing fiber nyob rau hauv nws qhov tsawg kawg nkaus khoov vojvoog ua rau micro-bending, uas ua rau kom attenuation. Nyob rau hauv ib lub thawv compact fiber, nruj pigtail routing nyob ib ncig ntawm cov ces kaum yog feem ntau qhov chaw ntawm micro- dabtsi yog khoov poob nyob rau hauv lub ntsia nroj tsuag.
Q: Kuv puas tuaj yeem ntxiv splice tais rau kuv lub thawv fiber ntau uas twb muaj lawm los ua kom muaj peev xwm?
A: Feem ntau yog, yog tias lub chassis tau tsim los txais cov tais ntxiv thiab lub thawv tsis tau raug thauj mus rau qhov siab tshaj plaws suav. Ua ntej yuav ib lub thawv fiber ntau, nug tus neeg muag khoom seb muaj pes tsawg lub tais qhov chassis muaj nyob rau hauv tag nrho cov piv txwv muaj pes tsawg lub tais nrog rau cov khoom xa tuaj. Ib lub thawv uas xa nrog ob 24- cov tais fiber ntau tab sis muaj plaub lub tais tuaj yeem hloov kho mus rau 96 splice txoj haujlwm hauv thaj teb yam tsis tau yuav ib lub thawv tshiab - qhov tseem ceeb rau kev txiav txim siab rau theem FTTH rollouts.
Q: Hom connector twg muab qhov chaw nres nkoj siab tshaj plaws hauv lub thawv fiber ntau?
A: LC connectors muaj 1.25 hli ferrule thiab daim ntawv me dua li SC (2.5 hli ferrule), yog li ib tug LC duplex adapter occupies roughly ib nrab ntawm lub vaj huam sib luag qhov chaw ntawm SC simplex adapter. Hauv siab - daim ntawv thov ceev - khib-mount ODFs, cov ntaub ntawv chaw thaj chaw thaj chaw - LC tso cai kwv yees li ob npaug ntawm qhov chaw nres nkoj suav ntawm tib lub ntsej muag phaj thaj tsam piv rau SC. Rau cov neeg siv khoom-faus FTTH lub thawv txiav tawm, SC/APC tseem yog hom sib txuas tseem ceeb thoob ntiaj teb vim nws tus nqi qis dua thiab qhov ntau ntawm SC-pigtailed ONTs.