Fiber optic handhole yuav tsum tsis txhob xaiv los ntawm fiber ntau suav ib leeg. Ob lub 144-fiber cables yuav xav tau ntau qhov chaw sib txawv vim hais tias txoj kab uas hla, khoov txwv, kaw hom, slack yuav tsum thiab duct kev taw qhia tuaj yeem sib txawv.

Qhov kev sim ua tau yooj yim: cov kws tshaj lij yuav tsum tuaj yeem nruab lub cable, teeb tsa lub slack thiab tshem tawm cov splice kaw tom qab. Lub chamber uas tsuas muaj cov khoom tom qab kev teeb tsa tuaj yeem tseem me me rau kev tsim kho kom zoo lossis kev saib xyuas.

Cov lus teb luv luv

Pib nrog qhov tseeb cable thiab splice kaw, tsis yog lub rooj loj loj.Paub meej tias qhov ntev kaw, cable- kev taw qhia nkag, cable khoov yuav tsum thiab xav tau slack. Tom qab ntawd txheeb xyuas lub qhov dej ntawm qhov pom tseeb hauv qhov ntev, npog qhov qhib thiab cov kav dej. Nominal qhov ntau thiab tsawg xws li 17 × 30, 24 × 36 thiab 30 × 48 ntiv tes yog cov ntsiab lus pib muaj txiaj ntsig, tsis yog kev ntsuas thoob ntiaj teb.

1. Txhais qhov yuav tsum tau haum rau hauv qhov Handhole

Pib nrog kev ua haujlwm ntawm qhov chaw. Ib qho rub taw tes tsuas yog coj ib lub cable ntawm cov ducts. Ib qho kev sib txuas kuj tseem tuaj yeem muaj lub dome lossis kab rov tav kaw, ob peb lub voj voog, ceg cables, mounting brackets thiab cov khoom seem. Ib ceg midspan ib txwm xav tau qhov chaw siv tau ntau dua li qhov sib txuas ncaj nraim vim tias cov khoom noj, nthuav qhia thiab ceg fibers yuav tsum nyob sib cais.

Pib nrog lub splice kaw

Sau qhov kev kaw kom tiav es tsis yog kuaj xyuas lub cev qhov ntev xwb:

  • kaw ntev, dav lossis txoj kab uas hla;
  • tus naj npawb, qhov loj me thiab kev taw qhia ntawm cov chaw nres nkoj cable;
  • dome, taub qab- nkag lossis inline configuration;
  • qhov chaw yuav tsum tau qhib thiab tshem tawm qhov kaw;
  • ncaj cable ntev yuav tsum tau ua ntej thawj khoov;
  • midspan thiab yav tom ntej ceg yuav tsum.

Lub Hwj ChimGL-L5-BR Dome Fiber Splice Kaw, piv txwv li, muaj qhov loj me ntawm 460 × Φ225 mm thiab lub pob tw - nkag. Nws tuaj yeem haum feeder thiab ceg cables los ntawm tib qho kev taw qhia. Qhov twg txoj kev cable txuas ntxiv los ntawm cov phab ntsa sab nraud, akab rov tav fiber ntau splice enclosuretuaj yeem ua kom zoo dua qub nrog txoj kev duct.

Paub meej tias cable khoov yuav tsum tau thiab slack

Cable sab nraud txoj kab uas hla thiab cov chaw tsim khoom khoov txwv cuam tshuam rau qhov xav tau lub voj qhov chaw ncaj qha ntau dua li suav fiber ntau. Sau cov qauv cable, OD, static thiab installation khoov yuav tsum, tus naj npawb ntawm cable xaus, midspan kev npaj thiab teev slack ntev.

Glory lubGYTS Sab nraum zoov Fiber Optic Cableluam tawm txawv diameters thiab khoov yuav tsum tau rau txawv fiber ntau. Cov khoom lag luam no- cov txiaj ntsig tshwj xeeb yuav tsum tau siv es tsis txhob siv ib qho kev xav dav dav rau txhua lub cable sab nraum zoov.

Slack yuav tsum txaus los nqa qhov kaw mus rau qhov xav tau splicing txoj hauj lwm, tab sis nws yuav tsum tsis txhob tso tseg raws li ib qho kev tswj tsis tau. CovFiber Optic Association txoj kev taw qhia kev teeb tsa hauv avpiav qhia vim li cas cov kev pabcuam kev pabcuam xav tau ntawm cov ntsiab lus hauv av. Qhov ntev tiag tiag tseem yuav tsum tau txhais los ntawm tus tswv network, cov lus qhia kaw thiab txoj cai kho dua tshiab.

Tsis txhob siv fiber ntau raws li txoj cai sizing

Ib qho kev sib cog lus 144-fiber cable yuav xav tau qhov chaw tsawg dua li qhov loj armored cable nrog tsawg fibers. Fiber suav pab xaiv splice muaj peev xwm; nws tsis ua pov thawj tias ib qho tshwj xeeb handhole tuaj yeem khaws lossis ua haujlwm ua tiav cable sib dhos.

2. Tshawb xyuas kev teeb tsa thiab kev pabcuam yav tom ntej

Ib qho kev pabcuam kev pabcuam yuav tsum dhau peb qhov kev kuaj xyuas: txhua yam tuaj yeem khaws cia, lub cable tuaj yeem ntsia tau yam tsis muaj kev khoov ntau dhau, thiab kaw tuaj yeem raug tshem tawm rau kev ua haujlwm yav tom ntej.

Khaws qhov xwm txheej

Txheeb xyuas qhov kaw, txhawb nqa slack loops, cable racks, cable tails, duct projections thiab reserved chaw ua ke.

Kev teeb tsa

Txheeb xyuas txoj kab ntawm txoj kab ntawm lub qhov ncauj, nrog rau qhov yuav tsum tau khoov loj dua uas yuav siv tau thaum lub cable raug rub los yog muab tso rau.

Re-kev nkag

Paub meej tias qhov kaw tuaj yeem dhau los ntawm kev qhib lub hau npog thiab ncav cuag txoj haujlwm ua haujlwm yam tsis muaj kev thauj mus los tsis cuam tshuam nrog cov cables.

Kev nthuav dav

Khaws ib txoj hauv kev meej rau ib ceg uas tau npaj tseg, kho lub voj lossis kaw thib ob es tsis txhob sau txhua qhov chaw siv tau thaum lub sijhawm thawj qhov kev teeb tsa.

Siv qhov dav dav, tsis yog lub npe khoom

Thov ib daim duab kos kom pom tseeb qhov tseeb ntawm qhov ntev, qhov dav thiab qhov tob, qhov qhib npog npog, sab hauv phab ntsa taper, npog kev txhawb nqa thiab khib txoj haujlwm. Lub chamber muag li 30 × 48 ntiv tes yuav muaj qhov qhib me me los yog nqaim qis dua.

Ib txoj kev npaj saib yuav tsum qhia qhov kaw, cov pawg slack thiab ducts ua ke. Ib sab saib yuav tsum paub meej tias cov hlua khi hlua khi tsis tau sau qhov tob lossis cuam tshuam nrog lub hau. Ib txoj kev tshem tawm cais yuav tsum qhia seb qhov kaw yuav raug tshem tawm li cas.

Tswj lub kav dej - cheeb tsam nkag

Cov kav dej nkag siv qhov chaw siv tau thiab feem ntau txiav txim siab thawj kab khoov. Daim duab pom zoo yuav tsum txheeb xyuas:

  • duct kom muaj nuj nqis thiab txoj kab uas hla;
  • phab ntsa nkag thiab tawm;
  • nkag siab thiab kev taw qhia;
  • qhov siab tshaj plaws nyob rau hauv lub chamber;
  • spare duct txoj hauj lwm thiab cov ntsaws ruaj ruaj;
  • lub hom phiaj rub txoj kev.

Lub kaum sab xis nkag tuaj yeem khaws cia qhov chaw nruab nrab ntawm lub voj voog, tab sis tsuas yog thaum lub cable tuaj yeem txuas ntxiv ib puag ncig ntawm phab ntsa. Random teb drilling feem ntau tso cov kav dej hauv thaj chaw npaj rau kev kaw lossis yuam kom rov qab khoov tam sim ntawd.

Zam cov layouts uas haum tab sis tsis tuaj yeem khaws cia

Feem ntau ua tsis tiav suav nrog kev siv qhov loj me me uas siv tau qhov ntev, tsis quav ntsej cov hlua ncaj nraim, tso cai rau cov ducts nyob hauv thaj chaw slack, xaiv lub hau qhib me dua qhov kaw thiab sib txuas ntau lub voj voog rau hauv ib lub nras tsis pom.

Tib lub hauv paus ntsiab lus kev pabcuam tseem nyob hauv qhov chaw kaw. Glory's guide tofiber optic splice tais teeb meemqhia tau hais tias kev ua haujlwm tsis zoo tuaj yeem ua rau muaj peev xwm txaus los tswj tau. Kev npaj ntawm tes yuav tsum tiv thaiv qhov kev sib tsoo ua ntej lub cable mus txog lub tais.

3. Xaiv lub Handhole thiab ua kom tiav Fiber Solution

Qhov ntau thiab tsawg ntawm tes yog qhov muaj txiaj ntsig zoo rau kev npaj ua ntej, tab sis kev xaiv zaum kawg yuav tsum ua raws li kev txheeb xyuas sab hauv.

Nominal handhole size Tej yam pib daim ntawv thov Lub ntsiab lus tseem ceeb kom paub tseeb
17 × 30 × 24 po Pulling point, me me slack voj los yog compact kaw Loop dav thiab ntshiab npog qhib
24 × 36 × 24 hli Nruab nrab splice point los yog txwv ceg node Kev txhim kho khoov thiab kaw - txoj kev tshem tawm
30 × 48 × 36 hli Loj kaw, ob peb ducts los yog ntau dua slack Rack txoj hauj lwm, duct layout thiab yav tom ntej expansion

 

Yog hais tias lub cable, kaw thiab txoj kev ua hauj lwm tsis tuaj yeem npaj tsis sib tshooj, cov lus teb tsis nruj dua. Txav mus rau qhov loj dua, lub hnab ntim khoom lossis cov qauv nkag tau. Glory lubHandhole vs Manhole rau Fiberphau ntawv piav qhia cov qauv dav dua - kev txiav txim siab xaiv.

Qhia txog kev thauj khoom, dej thiab cov ntaub ntawv sib cais

Internal sizing thiab structural loading yog txawv kev txiav txim. Tom qab qhov siv tau qhov ntev tau lees paub, xaiv cov chav kawm thauj khoom uas xav tau los ntawm qhov chaw teeb tsa thiab txoj haujlwm txoj cai.ANSI/SCTE 77hais txog kev ncaj ncees thiab kev ua haujlwm ntawm qib - qib underground enclosures; nws tsis suav qhov chaw xav tau los ntawm kev sib tw kaw lossis cov hlua cable.

RFQ yuav tsum tau hais txog cov dej hauv av, dej los yog cov ntaub pua tsev, kev sib khi, kev tiv thaiv -flotation yuav tsum, npog kev ruaj ntseg thiab cov ntaub ntawv yuav tsum tau ua - kuaj cov ntaub ntawv. Lub handhole tswj kev nkag thiab pej xeem tej yam kev mob; lub kaw splice kaw tiv thaiv qhov kev sib txuas ntawm qhov muag.

Siv ib qho RFQ rau tag nrho cov node

Ib qho kev thov kom muaj txiaj ntsig zoo yuav tsum ua ke:

  • yam tsawg kawg nkaus ntshiab sab hauv qhov ntev thiab lub qhov ncauj qhib qhib;
  • cable qauv, OD, khoov txwv thiab slack ib cable;
  • kaw qauv, qhov ntev, cable- nkag mus thiab txoj kev tshem tawm;
  • duct kom muaj nuj nqis, txoj kab uas hla, nkag phab ntsa thiab qhov projection;
  • installation nto, load yuav tsum tau thiab kua dej;
  • Diam duab kos duab, sab hauv layout thiab load-test report.

Kev nkag mus hauv av

GL58 Modular Fiber Optic Handhole

Sau nrog 30 × 48 nti sab hauv loj, 36 nti qhov siab thiab SCTE-77 Tier 22 configuration. Siv daim duab pom zoo kom paub meej tias lub hau npog qhib, cov kab nkag nkag thiab siv tau rau sab hauv.

Tshuaj xyuas Handhole Paub meej

Dome Splice Protection

GL-L5-BR Dome Splice Kaw

Lub pob tw- nkag dome configuration rau feeder thiab ceg cables. Nws lub cev, lub hauv paus, cable tails thiab txoj kev pabcuam yuav tsum suav nrog hauv qhov kev teeb tsa ntawm tes.

Saib xyuas cov ntsiab lus kaw

Inline Cable Routing

Kab rov tav Fiber Splice Enclosure

Ib qho kev xaiv inline enclosure rau txoj kev uas cov cables nkag mus thiab tawm mus rau sab nraud ntawm qhov chaw nkag mus hauv av.

Tshawb xyuas cov kev xaiv hauv kab

Sab nraum zoov Cable Input

GYTS Sab nraum zoov Fiber Optic Cable

Tshaj tawm cable diameters thiab khoov yuav tsum tau muab cov engineering inputs xav tau los xyuas lub voj qhov chaw thiab duct routing.

Tshawb xyuas Cable Cov ntsiab lus

Cov lus nug txog qhov loj me

Q: Qhov loj npaum li cas yog qhov xav tau rau 144-fiber cable?

A: Fiber suav ib leeg tsis txiav txim siab qhov loj. Txheeb xyuas cov kab kab thiab khoov qhov txwv, xaiv kaw, xav tau slack, duct txoj haujlwm, tshem tawm qhov chaw sab hauv thiab kaw - txoj kev tshem tawm.

Q: Puas yog 24 × 36 inch handhole loj txaus rau kev sib tw kaw?

A: Nws yuav haum rau lub kaw lus kaw thiab qhov kawg cable loops, tab sis nws tseem tuaj yeem ua me dhau rau kev teeb tsa cable lossis kev tshem tawm yav tom ntej. Paub meej qhov tseeb qhov ntev, npog qhib, cable khoov yuav tsum tau thiab duct layout.

Q: Ntau npaum li cas fiber ntau slack yuav tsum tau muab cia rau hauv ib lub handhole?

A: Siv tus tswv network tus qauv, cov lus qhia kaw thiab qhov kev ncua deb mus rau qhov kev npaj splicing. Qhov nruab nrab ntev yuav tsum tau teev tseg, teeb tsa thiab khaws cia.

Q: Puas yog ANSI / SCTE 77 qhia qhov ntev ntawm fiber ntau?

A: Tsis yog. Nws hais txog kev ncaj ncees ntawm cov ntaub thaiv npog thiab kev ua haujlwm ntawm kev thauj khoom. Nws tsis suav cov chamber qhov ntev uas yuav tsum tau los ntawm kev sib tw kaw, cable loops lossis duct nkag.

Q: Yuav tsum cov ducts nkag mus ze ntawm lub qhov rooj?

A: Lub kaum sab xis nkag tuaj yeem khaws cia qhov chaw hauv nruab nrab, tab sis tsuas yog thaum nws ua raws li txoj kev cable thiab zam kev rov qab khoov tam sim ntawd. Qhia txoj kev ua tiav ntawm daim duab kos duab pom zoo.

 

Ua kom lub qhov tuav nyob ib ncig ntawm qhov ua tiav fiber ntau

Xa cov qauv cable, splice- kaw qauv, xav tau slack, duct- nkag kos duab thiab teeb tsa kev teeb tsa. Hwjchim ci ntsa iab tuaj yeem ua raws li qhov tuav, kaw thiab sab nraum zoov cable specifications rau hauv ib qho kev pabcuam hauv av es tsis txhob kho lawv li cov khoom tsis sib xws.