Multiport Service Terminal (MST) rau FTTH: Daim Ntawv Qhia 2026 Deployment Guide

Apr 08, 2026

Tso lus

Multiport Service Terminal (MST) yog dab tsi? Txhais thiab Core Function

Mst Box

Multiport Service Terminal (MST) - kuj tseem hu ua MST fiber ntau davhlau ya nyob twg, MST lub thawv, los yog fiber ntau faib davhlau ya nyob twg - yog lub Hoobkas ua ntej- txiav tawm, kaw sab nraum zoov fiber ntau faib enclosure uas txuas lub feeder fiber ntau cables coj ncaj qha mus rau cov neeg siv khoom.

Tsis zoo li cov tsoos fiber ntau kaw, uas yuav tsum muaj fusion splicer, cov kws tshaj lij kev cob qhia, thiab 20-40 feeb ntawm kev ua haujlwm ntawm ib qho kev sib txuas, MST yog lub ntsaws-thiab- ua si. Cov kws kho mob tsuas txuas ua ntej -connectorized hardened drop cables rau nws cov zis ports - tsis muaj splicing, tsis muaj cuab yeej tshwj xeeb, tsis muaj fusion splicer yuav tsum tau.

Peb Txoj Haujlwm Tseem Ceeb uas MST Ua

Kev faib tawm cov teeb liab: faib cov khoom xa tawm fiber ntau cov teeb liab hla 2 mus rau 16 qhov chaw tso zis, txhua qhov kev pabcuam ib tus neeg siv khoom poob.

Kev tiv thaiv ib puag ncig: IP68- ntsuas cov vaj tsev kaw cov dej nkag ntawm 1-meter submersion qhov tob, talc plua plav nyob rau hauv qhov chaw siab, thiab qhov kub siab tshaj ntawm -40℃rau +70℃.

Kev xa mus nrawm: Ib tug ob -tus neeg ua haujlwm tuaj yeem txuas rau 8-chaw nres nkoj MST fiber ntau lub davhlau ya nyob twg hauv qis dua ob teev - piv rau plaub mus rau yim teev rau lub thawv ntim khoom raws li ib txwm muaj.

Qhov twg MST Fits hauv Koj FTTH ODN Architecture

MST nyob rau hauv kawg - mais txheej ntawm koj qhov Optical Distribution Network (ODN), nruab nrab ntawm Fiber Distribution Hub (FDH) thiab ib tus neeg rau ONTs:

OLT → Feeder Cable → FDH / Splice Kaw → MST Fiber Terminal → Pre-connectorized Drop Cable → ONT

Hauv GPON tes hauj lwm ua haujlwm ntawm 1: 32 qhov sib piv, ib qho MST nyob nruab nrab ntawm - kev faib tawm tuaj yeem pab 4-16 lub tsev los ntawm ib tus ncej, pedestal, lossis qhov chaw tuav - txo qis tag nrho cov xaim cable khiav thiab ua kom koj lub cev cable ntev luv thiab tswj tau.

Hom MST Fiber Terminals: Xaiv txoj cai Configuration

MSTs tsis yog ib qho -loj- haum- tag nrho. Ib puag ncig, chaw nres nkoj suav, connector ecosystem, thiab feeder cable hom txhua tus tsav txoj kev xaiv. Ntawm no yog qhov kev faib ua tiav:

Los ntawm Mounting Method

Aerial MST (Pole-Mounted lossis Strand-Mount)

Muab tso rau ntawm cov khoom siv hluav taws xob lossis dai los ntawm huab cua strand, MST hom no yog tsim los rau UV raug, cua load, thiab dav kub caij tsheb kauj vab. Nws yog qhov ceev tshaj plaws MST rau kev xa mus rau hauv suburban thiab nyob deb nroog vim nws yuav tsum tsis muaj underground trenching. Mounting hardware feem ntau suav nrog stainless hlau bands thiab universal bracket kits.

Qhov zoo tshaj plaws rau: FTTH nyob deb nroog thiab suburban rollouts, aerial distribution networks, greenfield deployments where trenching ROI is unfavorable.

Underground MST (Pedestal, Handhole, lossis Manhole)

Muab tso rau hauv lub tes tsho, pedestals, los yog hauv av vaults, lub underground MST yuav tsum tau txhim khu kev tiv thaiv thiab sealing. IP68 pov thawj - tau lees paub los ntawm IEC 61300-2-1 kev sim submersion - tsis yog sib tham ntawm no, vim tias lub kaw lus tuaj yeem zaum hauv dej sawv ntsug rau lub sijhawm ntev.

Qhov zoo tshaj plaws rau: Kev sib txuas hauv nroog hauv av, thaj chaw nyob tuab, cov phiaj xwm hauv nroog loj.

Phab ntsa-Mounted MST

Compact thiab low-profile, phab ntsa-mounted MST yog qhov zoo tagnrho rau ntau- tsev nyob (MDU) cov tsev, chaw ua lag luam, thiab thaj chaw hauv tsev kawm ntawv qhov twg tus ncej lossis underground installation tsis siv tau.

Qhov zoo tshaj plaws rau: Cov tsev tsev, cov zej zog gated, chaw ua haujlwm chaw ua si, MDU kawg - mais kev sib txuas.

Los ntawm Port Count

2–4 chaw nres nkoj: Taw tes- rau- taw tes rau kev xa tawm, tsawg- thaj chaw nyob deb nroog, cov tsev nruab nrab hauv cov zej zog gated.

6–8 chaw nres nkoj: Standard suburban FTTH - feem ntau configuration thoob ntiaj teb. Zoo tagnrho rau txoj kev - los ntawm - txoj kev suburban rollout.

12–16 cov chaw nres nkoj: Siab- kev xa tawm hauv nroog ceev, MDU cov ntsiab lus nkag, FDH hla kev teeb tsa.

Los ntawm Connector Ecosystem

Hom Connector

Geographic Market

Daim ntawv thov

Hwj chim Compatibility

OptiTap (Corning)

North America, Nyiv

Chaw nyob FTTH, tus qauv GPON/XGS-PON

Kev them nyiaj yug tag nrho - tau tshaj poob cable ntau yam

Mini SC (Huawei)

Ntiaj teb no (xws li Africa, SE Asia, Middle East)

Telecom tus neeg teb xov tooj loj - teev rollouts

Kev them nyiaj yug puv - Mini SC rau Mini SC cov rooj sib txoos

FullAXS LC (CommScope)

Teb chaws Europe, Latin America

ISP thiab kev lag luam fiber ntau nkag

Kev them nyiaj yug tag nrho - FullAXS LC ua ntej- txiav cables

H-Connector (Huawei variant)

Tuam Tshoj, Africa

National broadband network tej yaam num

Txhawb nqa tag nrho

ODVA SC/APC

Ntiaj teb no ntau- neeg muag khoom

Retrofit, upgrade scenarios

Txhawb nqa tag nrho

Glory Optical txhawb TAG NRHO tsib qhov loj hardened connector ecosystems - qhov widest compatibility ntawm lub lag luam. Cov neeg sib tw feem ntau tsuas yog txhawb nqa ib lossis ob lub kaw lus, yuam cov kev hloov pauv hloov pauv nyiaj txiag thaum ntsuas thoob plaws cheeb tsam.

Stub Tail vs Stubless MST: Qhov twg yog txoj cai rau koj qhov project?

Qhov no yog ib qho kev nkag siab yuam kev uas feem ntau cuam tshuam rau kev xa khoom xa mus:

Stub Tail MST: Lub tsev ships nrog lub Hoobkas - ua ntej - txiav tawm feeder fiber stub (feem ntau 2–10 m) protruding los ntawm lub enclosure. Lub installer txuas lub feeder cable los ntawm mechanical splice los yog fusion splice nyob rau hauv ib lub tais splice. Qhov zoo tshaj plaws rau tej yaam num uas pes tsawg feeder cable txiav lengths tsis paub ua ntej.

Stubless MST: Lub feeder nkag mus rau hauv lub thawv los ntawm qhov chaw nres nkoj ncaj qha nkag, thiab tag nrho cov kev sib txuas fiber ntau yog tsim los ntawm lub hoobkas. Zero teb splicing yuav tsum tau ntawm txhua qhov chaw nres nkoj. Kev xaiv xa mus ceev tshaj plaws, tab sis yuav tsum muaj qhov tseeb ua ntej - ntsuas qhov ntev cable. Qhov zoo tshaj plaws rau kev ua haujlwm zoo - phiaj xwm greenfield.

MST vs FAT vs Splice Kaw: Ua tiav kev sib piv rau FTTH Network Designers

Nkag siab qhov sib txawv ntawm peb hom cuab yeej no yog qhov tseem ceeb rau kev xaiv txoj cai ODN architecture. Cov lus hauv qab no suav nrog kev xa mus ceev, tus nqi, kev txawj ntse, thiab ntev - lub nra ntawm kev saib xyuas lub sijhawm - cov yam uas ua rau tag nrho cov nqi ntawm kev ua tswv cuab tshaj 20-xyoo network lub neej.

Kev ntsuas

MST Fiber Terminal

FAT (Fiber Access Terminal)

Splice Kaw

Txoj kev teeb tsa

Plug-thiab-ua si, tsis muaj cuab yeej

Ib feem ua ntej- xaus

Fusion splice nkaus xwb

Kev xa tawm ceev

ceev heev (< 2 hrs/node)

Nruab nrab (2-4 teev / node)

Slow (4-8 teev / node)

Kev txawj ntse

Tsawg - cov neeg ua haujlwm junior

Nruab nrab

Siab - ntawv pov thawj splicer

Cov nqi zog txuag vs splice

30-50% qis dua

15-25% qis dua

Lub hauv paus (0%)

Kev tiv thaiv ib puag ncig

IP68 ntsuas

IP65 / IP67 raug

IP68 (kev sib khi)

Tus neeg siv khoom qhib

Instant - ntsaws rau hauv poob

Tib hnub

Yuav tsum tau rov- qhib

Ntev - tu ncua sij hawm

Tsawg kawg - chaw nres nkoj kaw

Nruab nrab

Complex - splice tais nkag

Daim ntawv thov zoo tshaj plaws

FTTH xeem mais, 5G FTTA

Access txheej, hybrid ODN

Pem hauv ntej, feeder cable txuas

XGS-PON tau tshaj

Yog (wavelength-agnostic)

Nyob ntawm tus qauv

Yog (passive device)

Kev lag luam tus nqi qauv cov ntaub ntawv: A 192-lub tsev FTTH subdivision siv nrog MST hardened connector technology txo tag nrho OSP faib-sab nqi los ntawm kwv yees li 19% ib lub tsev dhau, nrog splicing nqi ib leeg txo los ntawm ~ 70%. (Source: TE Connectivity MST Tus Qauv Kawm Tus Nqi)

Cov Lus Qhia Tseem Ceeb thiab Cov Qauv Ntsuas rau Sab Nraud MST

Ib qho MST siv nyob rau sab nraum zoov FTTH lossis 5G FTTA ib puag ncig yuav tsum dhau qhov kev xeem nruj ib puag ncig, kev siv tshuab, thiab kho qhov muag pom kev. Ntawm Glory Optical, txhua qhov MST fiber ntau lub davhlau ya nyob twg tau lees paub raws li cov qauv hauv qab no ua ntej xa khoom xa tuaj:

Kev Tiv Thaiv IP68 - Kev kuaj plua plav thiab dej nkag

IP6X Plua Plav Test: Siab-concentration talc hmoov ib puag ncig, nqus tau thov rau 8 teev. Pass criterion: xoom plua plav ingress. Txuj: IEC 60529

IPX8 Water Test: Tag nrho submersion ntawm 1 meter qhov tob rau 1 teev. Dhau qhov ntsuas: xoom dej nkag mus rau txhua qhov chaw nres nkoj. Txuj: IEC 60529

Ntsev Txau Corrosion Resistance

Nruam nruab nrab ntsev tsuag ntawm 35℃rau 24 teev ib IEC 61300-2-26:2006. Glory MST units qhia xoom corrosion, xeb, lossis plating degradation post-kev sim - qhov tseem ceeb rau thaj chaw ntawm ntug dej hiav txwv, chaw sov, thiab cov av noo siab xws li Southeast Asia, West Africa, thiab Caribbean.

Siv:IEC 61300-2-26: Fiber Optic Interconnecting Devices - Kev ntsuas ntsev tsuag 

Mechanical Impact thiab Vibration

Poob pob cuam tshuam: 1 kg steel pob poob ntawm 1 meter qhov siab (IEC 61300-2-12: 2009 Txoj Kev B). Tsis pom kev puas tsuaj.

Vibration Test: 10 Hz sinusoidal kev co rau 30 feeb ib axis (IEC 61300-2-1: 2009). Cov qauv ruaj khov, tsis muaj qhov txuas txuas ntxiv, kho qhov muag txuas ntxiv.

Kev ua haujlwm kub

Kev khiav hauj lwm ntau: -40℃rau +70℃kev ua haujlwm tas mus li.

Qhov kub thiab txias caij tsheb kauj vab: Hloov nrawm ntawm -40℃rau +65℃. Tsis muaj deformation, foob tsis ua haujlwm, lossis kho qhov muag pom tom qab ntau lub voj voog.

Ntev -lub sijhawm kub caij tsheb kauj vab: Nthuav qis- lub voj voog siab tshaj 7+ hnub. Insertion poob variation <0.1 dB thoob.

Optical Performance Specifications

Parameter

Specification

Txuj

Insertion Loss (IL) ib qhov chaw nres nkoj

Tsawg dua lossis sib npaug li 0.35 dB

IEC 61754 Telcordia GR-326

Rov Los Loss (RL) - SC/APC

Ntau dua lossis sib npaug li 65 dB

IEC 61754-4: Cov

Rov Los Loss (RL) - SC/UPC

Ntau dua lossis sib npaug li 50 dB

IEC 61754-4: Cov

Repeatability (mating voj voog)

Ntau dua lossis sib npaug rau 500 cycles, IL hloov <0.2 dB

Telcordia GR-326

Fiber hom

OS2 SM G.652.D / G.657.A1 / G.657.B3

ITU-T G.652 / G.657

GPON lub wavelengths

1310nm / 1490nm / 1550nm (PON)

ITU-T G.984 (GPON)

XGS-PON wavelengths

1270 nm (US) / 1577 nm (DS)

ITU-T G.9807 (XGS-PON)

Siv:Telcordia GR-326 - Ib leeg-Mode Optical Connectors thiab Jumper Assemblies 

Siv:ITU-TG.657 - Cov yam ntxwv ntawm kev khoov- Loss Insensitive Ib Leeg-Mod Optical Fiber 

MST rau 5G FTTA (Fiber rau lub kav hlau txais xov): Ib Daim Ntawv Thov Ntxiv

Thaum MST fiber ntau cov davhlau ya nyob twg tau tsim los rau FTTH kawg- mais nkag, 5G network densification tau tsim kev lag luam loj thib ob: Fiber rau kav hlau txais xov (FTTA) ntawm macro cell thiab cov chaw me me.

Hauv 5G fronthaul architecture, MST txuas rau chav tsev Baseband (BBU) mus rau Chaw Taws Teeb Hluav Taws Xob (RRUs) mounted ntawm qhov siab ntawm cov yees thiab ru tsev. Tib IP68- ntsuas cov vaj tsev kaw, cov cuab yeej sib txuas hardened, thiab ua ntej txiav cable txoj hauv kev uas yooj yim rau kev xa tawm FTTH txhais ncaj qha rau hauv 5G cell site commissioning sai dua.

FTTA Solution

Cov Lus Qhia Tseem Ceeb rau 5G FTTA MST

Kev khiav hauj lwm kub ntawm -40℃rau +70℃rau pej thuam sab saum toj raug.

Cua thiab kev vibration tsis kam - IEC 61300-2-1 kev co tsim nyog.

Hardened DLC (Duplex LC) los yog MPO connectors rau siab -density fronthaul kev sib txuas.

Compatibility nrog Huawei AAU, Ericsson Xov tooj cua, thiab Nokia AirScale RRU interface qauv.

CPRI thiab eCPRI raws tu qauv transparency - lub passive MST yog raws tu qauv-agnostic, yuav tsum tsis muaj firmware los yog active Cheebtsam.

Glory Optical's MST portfolio npog ob qho tib si FTTH OptiTap/Mini SC nkag mus rau daim ntawv thov THIAB 5G FTTA hardened DLC/MPO configurations - nrog IEC- sim, IP68 enclosures tsim nyog rau -40℃rau +70℃ua hauj lwm nyob rau hauv ntauwd-saum ib puag ncig.

MST nrog Ua -hauv PLC Splitter: Simplified PON Distribution

Rau GPON thiab XGS-PON xa tawm, MST fiber ntau lub davhlau ya nyob twg tuaj yeem ua ke nrog PLC (Planar Lightwave Circuit) splitter ncaj qha rau hauv lub thawv. Qhov kev teeb tsa no - qee zaum hu ua MST splitter lossis MST faib lub thawv - tshem tawm cov vaj tsev cais cais hauv ODN, txo tag nrho cov khoom suav thiab cov ntsiab lus tsis ua haujlwm.

Nws ua haujlwm li cas

Ib qho OS2 feeder fiber ntau nkag mus rau hauv lub thawv. Sab hauv PLC splitter faib cov teeb liab kho qhov muag ntawm qhov sib piv (feem ntau 1 × 4, 1 × 8, lossis 1 × 16). Cov teeb liab sib cais yog xa mus rau ib tus neeg hardened output ports. Txhua qhov chaw nres nkoj txuas ncaj qha mus rau lub pre{10}}connectorized poob cable ua rau ib tus neeg siv ONT.

Thaum Yuav Siv MST nrog Ua -hauv Splitter

Greenfield FTTH deployments nrog paub cov neeg siv khoom ceev qhov twg ib qho kev sib cais ua haujlwm rau tag nrho cov node.

Kev xa mus nyob deb nroog qhov twg txo cov khoom siv hauv teb thiab cov ntsiab lus tsis ua haujlwm yog qhov tseem ceeb.

Cov tes hauj lwm tsom XGS-PON txij hnub ib, qhov twg cov neeg siv khoom xav tau ceev ua rau 1 × 8 lossis 1 × 16 faib kev lag luam tsim nyog.

Thaum Yuav Khaws Splitter cais

Brownfield hloov kho qhov twg uas twb muaj lawm feeder infrastructure twb muaj splitter infrastructure nyob rau hauv qhov chaw.

Siab -Kev xa tawm hauv nroog qhov ceev uas yuav tsum tau ua kom muaj kev sib npaug ntawm kev sib cais ntawm cov nodes.

Tus Nqi Tag Nrho Cov Tswv Cuab (TCO) Qauv: MST vs Traditional Splice Kaw

Tus nqi yuav ntawm MST fiber ntau lub davhlau ya nyob twg yog siab dua qhov yooj yim splice kaw. Txawm li cas los xij, thaum koj suav rau kev teeb tsa kev ua haujlwm, kev cob qhia cov kws tshaj lij, cov tsheb thauj khoom, thiab kev saib xyuas tsis tu ncua tshaj li 20- xyoo network lub neej, MST tsis tu ncua txo nqi tag nrho. Ntawm no yog ib qho yooj yim ib-tsev TCO qauv raws li cov ntaub ntawv kev lag luam:

Qeb Nqi

MST Approach (ib lub tsev dhau mus)

Splice Kaw Txoj Kev

Distribution-sab kho vajtse

Siab dua (MST chav tsev nqi)

Lower (tsuas yog kaw)

Distribution -sab cable nqi

-85% vs splice (pre-stub suav nrog hauv MST)

Siab dua (sib cais rub)

Splicing nqi zog

-70% (tsis muaj splicing yuav tsum tau)

Lub hauv paus

Txuag cable rub tus nqi

-25%

Lub hauv paus

Lub sijhawm ua kom cov neeg siv khoom

Tib -hnub - ntsaws rau hauv poob

Yuav tsum muaj neeg coob rov qab los

TOTAL OSP tus nqi ib lub tsev dhau mus

~ 19% LOWER dua li splice mus kom ze

Lub hauv paus (100%)

20-xyoo kev saib xyuas tus nqi

Tsawg heev (sau, tsis muaj rov- nkag)

Tsis tu ncua re- nkag thiab rov- sealing

Cov ntaub ntawv qhov chaw: TE Connectivity MST tus qauv kev kawm tus nqi sab hauv, phased 192-tsev subdivision nrog yim lub tsev ib lub thaiv, siv hardened drop connector architecture.

Siv:TE Connectivity MST Tus Nqi Ua Qauv Dawb 

Yuav Ua Li Cas Xaiv Txoj Cai MST: Ib Daim Ntawv Qhia Txog Tus Neeg Yuav Khoom

Siv daim ntawv txheeb xyuas no thaum qhia txog MST fiber ntau davhlau ya nyob twg rau koj qhov FTTH lossis FTTA qhov project:

Xaiv Factor

Yuav Qhia Li Cas

Kev xa tawm ib puag ncig

Aerial / underground / phab ntsa -mount - txiav txim siab qib enclosure thiab mounting hardware

Chaw nres nkoj suav

4-8 rau suburban FTTH; 12–16 rau MDU hauv nroog lossis siab - ceev

Hom Connector

OptiTap rau North America; Mini SC rau thoob ntiaj teb; FullAXS rau Europe

Feeder nkag txoj kev

Stub tail yog tias tsis paub qhov ntev ntawm cable; stubless yog tias tag nrho engineered

Splitter kev koom ua ke

Ua-hauv PLC rau GPON/XGS-PON faib cov nodes; sab nraud rau saj zawg zog ODN

Kev ntsuas IP

IP68 yuav tsum tau rau hauv av thiab dej nyab-kev pheej hmoo huab cua; IP65 yam tsawg kawg nkaus rau tag nrho lwm tus

Qhov kub thiab txias

-40℃rau +70℃rau sab nraum zoov siv; Paub meej nrog IEC 60068 cov ntaub ntawv ntsuas kev caij tsheb kauj vab

Network hom

Paub meej tias GPON lossis XGS-PON wavelength compatibility (G.657.A2 lossis B3 fiber)

Yuav tsum tau ntawv pov thawj

ISO 9001: 2015, CE, RoHS; Telcordia GR-326 rau North American cov haujlwm ua haujlwm

OEM / kev cai yuav tsum tau

Kev suav cov chaw nres nkoj, kev tsim khoom lag luam, ntim khoom - muaj nyob nrog 20-35 hnub ua haujlwm ntawm Glory

Tiag -World MST Deployment Scenarios: Regional Case Studies

Southeast Asia: National FTTH Rollout - Philippines Market

Ib tug loj Philippine ISP (tus qauv ntawm Converge ICT kev xa tawm profile) tau xa mus rau 8-chaw nres nkoj Mini SC MST units ntawm cov ncej dav hlau thoob plaws Luzon. Cov txiaj ntsig tseem ceeb tshaj li 18 lub hlis: lub sijhawm ua kom cov neeg siv khoom raug txo los ntawm 3 hnub (splice kaw txoj hauv kev) mus rau tib -hnub. Kev teeb tsa pawg neeg loj txo los ntawm plaub-tus neeg fusion splice pab pawg mus rau ob-tus neeg ntsaws-thiab- cov neeg ua si. Tag nrho cov nqi xa tawm mus rau ib lub tsev dhau los txo qis los ntawm kwv yees li 22% piv rau ODN tsim dhau los.

Western Europe: Chav tsev MDU Kev xa tawm - Ltalis Kev Lag Luam

Tus neeg teb xov tooj FTTP Italian (raws li Open Fiber's network expansion) siv phab ntsa-mounted 12-chaw nres nkoj MST units hauv ntau- tsev nyob (MDU) lub tsev risers, siv FullAXS LC hardened connectors. Lub ntsaws ntsaws ruaj ruaj-thiab- ua si txoj hauv kev tshem tawm rov- kev hu xov tooj hauv thawj ob xyoos ntawm kev ua haujlwm - ib qho kev txhim kho tseem ceeb ntawm txoj kev faib khoom yav dhau los uas tau siv hauv cov tsev laus retrofits.

Sub-Saharan Africa: Rural Infrastructure - Nigeria thiab Ethiopia

Hauv kev xa mus rau African nyob deb nroog, cov kws tshaj lij tsis txaus ntseeg tshwj xeeb. Glory Optical's Mini SC MST units tau raug xa tawm los ntawm cov neeg ua haujlwm thoob plaws hauv tebchaws uas tau tshaj tawm tias cov pab pawg me me nrog ob hnub ntawm kev cob qhia - es tsis yog ob - lub limtiam fusion splicing daim ntawv pov thawj txheej txheem - tuaj yeem nruab thiab qhib cov khoom xa tawm tiav. Kev xa tawm nrawm tau nce ntau dua 3x ib tus neeg ua haujlwm hauv ib hnub.

Glory OpticalMST Fiber Terminal: Factory-Direct Advantage

info-800-450

Glory Optical Communication tau tsim cov khoom siv kho qhov muag tsis pom kev (PON) ntawm peb lub chaw Ningbo, Zhejiang txij li xyoo 2008. Peb cov MST fiber ntau terminals yog tsim nyob rau hauv ISO 9001: 2015 kev tswj kom zoo - nrog tag nrho batch traceability los ntawm raw khoom tshuaj xyuas los ntawm lub Hoobkas - txiav tawm thiab ua ntej {{5}.OT.

Dab tsi ua rau Glory Optical's MST txawv

Widest connector compatibility: OptiTap, Mini SC, FullAXS LC, H-Connector, thiab ODVA SC/APC - tag nrho los ntawm ib lub Hoobkas, tag nrho cov poob - cable - kuaj.

Vertically integrated: Los ntawm kev txhaj tshuaj molding thiab txuas txuas txuas mus rau kev txiav tawm fiber ntau thiab kev soj ntsuam zoo - xoom outsourced Cheebtsam.

OEM/ODM tag nrho - kev pab cuam lub voj voog: Kev cai chaw nres nkoj teeb tsa, xim xim, cim npe, thiab ntim khoom. Prototyping ceev ceev hauv 5-7 hnub ua haujlwm; ntau lawm hauv 20-35 hnub ua haujlwm.

Cov ntaub ntawv pov thawj thoob ntiaj teb: MST units tau xa mus rau hauv lub teb chaws broadband network thoob plaws 50+ lub teb chaws hauv Asmeskas, Europe, Africa, Middle East, thiab Southeast Asia.

Factory-kuaj kho qhov muag specs: IL Tsawg dua lossis sib npaug ntawm 0.35 dB, RL Ntau dua lossis sib npaug li 65 dB (SC/APC), 500- voj voog mating durability - daim ntawv pov thawj muaj nyob ntawm kev thov.

Tag nrho Glory Optical MST units nkoj nrog IEC daim ntawv pov thawj (IP68, tshuaj tsuag ntsev, kub caij tsheb kauj vab, kev co) thiab lub Hoobkas OTDR cov ntaub ntawv teev tseg. ISO 9001: 2015 Daim ntawv pov thawj No.

Cov lus nug nquag

Cov 10 FAQ no yuav tsum tau cim nrog FAQPage Schema ntawm nplooj ntawv luam tawm kom ntes Google PAA lub thawv.

Q1: Dab tsi yog Multiport Service Terminal (MST) hauv FTTH?

Multiport Service Terminal (MST) yog lub Hoobkas ua ntej- tau txiav tawm, kaw cov khoom siv sab nraum zoov fiber ntau siv hauv FTTH thiab FTTx tes hauj lwm los txuas lub tshuab pub khoom noj rau ntau tus neeg siv khoom poob cables. Nws tshem tawm ntawm -site fusion splicing, tso cai ntsaws- thiab- ua si xa tawm nrog ua ntej- txuas txuas hardened drop cables.

Q2: Qhov txawv ntawm MST thiab FAT hauv fiber ntau yog dab tsi?

Ib qho MST (Multiport Service Terminal) yog tag nrho ntsaws - thiab - ua si - tsis tas yuav tsum muaj qhov sib txuas ntawm qhov chaw nres nkoj. Lub FAT (Fiber Access Terminal) feem ntau yuav tsum muaj ib feem splicing rau kev sib txuas ntawm feeder. MST kev xa tawm sai dua (tsawg dua 2 teev ntawm ib qho), yuav tsum muaj cov kws tshaj lij kev txawj ntse, thiab xa tawm kwv yees li 30-50% tus nqi ua haujlwm qis dua rau ib lub ntawm FAT.

Q3: Muaj pes tsawg qhov chaw nres nkoj MST txhawb nqa?

MST fiber ntau terminals muaj nyob rau hauv 2, 4, 6, 8, 12, thiab 16 chaw nres nkoj configurations. Rau tus qauv suburban FTTH, 6-8 chaw nres nkoj yog qhov kev xaiv tshaj plaws. High{10}}cov ntawv thov hauv nroog thiab MDU feem ntau siv 12–16 chaw nres nkoj.

Q4: Dab tsi connector hom siv nyob rau hauv MST fiber terminals?

Hom connector tseem ceeb rau MST yog: OptiTap (tseem ceeb hauv North America), Mini SC (tus qauv hauv kev lag luam thoob ntiaj teb suav nrog Africa, Southeast Asia, thiab Middle East), FullAXS LC (ib txwm nyob hauv Europe), thiab H-Connector (Huawei tes hauj lwm). Glory Optical MST units txhawb nqa tag nrho cov kev sib txuas loj ecosystems.

Q5: Puas yog MST siv tau nrog GPON thiab XGS-PON networks?

Yog lawm. MST yog ib qho khoom siv tag nrho - nws kis tau txhua qhov kev kho qhov muag tsis muaj kev ntxub ntxaug. Nws yog sib xws nrog GPON (1310/1490/1550 nm) thiab XGS-PON (1270/1577 nm) tes hauj lwm, nrog rau cov qauv PON yav tom ntej. Qhov kev xav tau tseem ceeb yog qhov poob cable fiber ntau hom (G.657.A2 lossis G.657.B3) phim koj tus qauv ODN.

Q6: IP68 txhais li cas rau lub thawv MST sab nraum zoov?

IP68 txhais tau hais tias lub kaw lus tsis muaj plua plav tag nrho (IP6X) thiab tuaj yeem tiv taus qhov dej tsis tu ncua ntawm 1-meter qhov tob rau yam tsawg 1 teev (IPX8) yam tsis muaj dej nkag. Qhov no yog tus qauv siab tshaj plaws rau sab nraum zoov fiber ntau enclosures thiab raug txheeb xyuas los ntawm IEC 60529 kev sim. IP68 yog qhov tseem ceeb rau hauv av (khole / manhole) thiab dej nyab-kev pheej hmoo huab cua MST xa tawm.

Q7: Dab tsi yog lub pob tw hauv MST, thiab thaum twg kuv yuav tsum siv nws?

Lub taub hau taub hau MST nkoj nrog lub Hoobkas - ua ntej - txiav tawm fiber ntau stub (feem ntau 2–10 m) protruding los ntawm qhov chaw nres nkoj feeder. Lub teb installer ua ib qho fusion splice nyob rau hauv ib lub tais splice kom txuas lub stub mus rau cov khoom xa tuaj. Siv lub taub hau taub hau MST thaum feeder cable txiav lengths tsis tau precisely ua ntej - npaj. Siv stubless MST thaum cable ntev yog tag nrho engineered ua ntej xa mus.

Q8: Puas tuaj yeem MST hloov FDH (Fiber Distribution Hub)?

Nyob rau hauv qis - mus rau - nruab nrab qhov ceev xa tawm, MST nrog kev sib xyaw PLC splitter tuaj yeem hloov FDH cais los ntawm kev sib koom ua ke fiber ntau faib thiab teeb liab sib cais hauv ib qho chaw kaw. Txoj hauv kev MST yog qhov ua tau zoo tshaj plaws rau kev faib tawm - mus rau - cov txheej txheem rau npe. Rau siab -cov chaw ntom ntom ua haujlwm rau 64+ cov neeg siv khoom, FDH nplooj siab tseem tsim nyog dua.

Q9: Tus nqi ntau npaum li cas ntawm Multiport Service Terminal?

MST tus nqi sib txawv ntawm cov chaw nres nkoj suav, hom txuas, thiab cov lus qhia tshwj xeeb. A 4-chaw nres nkoj Mini SC MST feem ntau pib ntawm kwv yees li $35–60 ib chav nyob hauv ntim. Ib qho 8-chaw nres nkoj OptiTap MST nrog stub tail feem ntau yog li ntawm $ 80-150 nyob ntawm kev teeb tsa. Hu rau Glory Optical pab pawg muag khoom rau qhov project tshwj xeeb BOM thiab ntim nqi.

Q10: Kuv yuav tsum tau ntawv pov thawj dab tsi rau tus neeg xa khoom MST?

Rau cov haujlwm thoob ntiaj teb kev sib txuas lus, xav tau: ISO 9001: 2015 (kev tswj hwm zoo), CE thiab RoHS ua raws, IP68 ntawv pov thawj rau IEC 60529, thiab rau North American cov haujlwm ua haujlwm, Telcordia GR-326 connector tsim nyog. Rau kev xa tawm mus rau kev tswj hwm kev lag luam hauv Tebchaws Europe thiab North America, CE daim ntawv pov thawj yog qhov yuav tsum tau ua.

Xa kev nug