Vim li cas PLC Splitters tau dhau los ua Tus Qauv Kev Lag Luam

Ua ntej kev tswj hwm ntawm PLC thev naus laus zis, FBT (Fused Biconical Taper) splitters yog qhov kev xaiv. Lawv yog tsim los ntawm twisting thiab fusing fibers ua ke, uas ua hauj lwm zoo rau me me phua ratios tab sis ua teeb meem raws li lub network teev. FBT splitters yog ntau wavelength-rhiab heev, tsis sib xws nyob rau hauv cov zis ports, thiab tsis ruaj khov nyob rau hauv qhov kub thiab txias.
PLC splitters, ntawm qhov tod tes, yog fabricated siv semiconductor manufacturing txheej txheem. Lub silica waveguide Circuit Court yog etched rau ntawm silicon nti, tsim ib txoj hauv kev kho qhov muag uas faib cov teeb liab tuaj rau hauv cov txiaj ntsig zoo kawg nkaus. Qhov tshwm sim yog ib qho khoom siv uas:
• Ua haujlwm thoob plaws qhov dav wavelength (1260-1650nm)
• Tswj kev sib cais zoo sib xws (feem ntau Tsawg dua lossis sib npaug rau 0.6 dB)
• Ua tau zoo los ntawm -40℃rau +85 degree
• Scales huv si mus txog 1 × 64 los yog txawm 1 × 128 splits
Hauv FTTH, PON, thiab cov ntaub ntawv chaw siv ntaub ntawv, PLC splitters tau dhau los ua qhov kev xaiv xaiv nyob qhov twg qhov kev ua tau zoo thiab kev ntseeg siab tsis tuaj yeem sib tham.
Cov Naj Npawb Qhov Tseem Ceeb
Thaum sib piv PLC splitters los ntawm cov chaw muag khoom sib txawv, peb qhov kev ntsuas kev tsim nyog tau txais kev pom zoo. Nov yog qhov kev ua tau zoo zoo li rau 1 × 8 splitter, tab sis cov hauv paus ntsiab lus siv thoob plaws txhua qhov sib faib.
Insertion Loss- Qhov no yog lub zog kho qhov muag poob thaum lub teeb liab dhau los ntawm lub splitter. qis dua yog zoo dua. Rau qhov ua tau zoo 1 × 8 splitter, cia siab tias qhov poob qis ib puag ncig Tsawg dua lossis sib npaug li 10.5 dB. Ib qho 1 × 32 splitter feem ntau yuav qhia tsawg dua lossis sib npaug rau 16.5 dB, thaum 1 × 64 tuaj yeem ncav cuag Tsawg dua lossis sib npaug li 20.5 dB. Kev nkag siab txog cov lej no yog qhov tseem ceeb rau kev suav koj lub network cov peev nyiaj kho qhov muag. GPON ib txwm muaj peev xwm siv nyiaj txog 28 dB ntawm OLT thiab ONT. Yog tias koj cov splitters ib leeg noj 20 dB ntawm qhov ntawd, koj muaj cov paj me me heev rau cov fiber ntau attenuation thiab connector poob.
Kev tsis sib xws- Qhov no ntsuas qhov ua tau zoo npaum li cas cov teeb liab tso tawm thoob plaws txhua qhov chaw nres nkoj. Ib qho tsis sib xws ntawm Tsawg dua lossis sib npaug ntawm 0.6 dB ua kom lub tsev txuas nrog rau qhov chaw nres nkoj 1 tau txais cov teeb liab zoo ib yam li lub tsev txuas nrog rau qhov chaw nres nkoj 32. Hauv kev xa tawm loj, qhov tsis zoo sib xws ua rau muaj kev sib txawv ntawm cov kev pabcuam uas nyuaj rau kev daws teeb meem. Piv txwv li, yog tias ib qho chaw nres nkoj poob 0.5 dB ntau tshaj qhov nruab nrab, qhov chaw nres nkoj yuav muaj qhov tsis tshua muaj txiaj ntsig rau yav tom ntej degradation - thiab cov neeg siv khoom ntawd yuav yog thawj tus tau ntsib teeb meem tsis sib xws thaum fiber ntau tau qias neeg lossis kub poob.
Rov Los Loss thiab Directivity- Rov qab poob (Ntau dua lossis sib npaug li 55 dB) ntsuas qhov zoo li cas lub splitter qhia txog cov cim tsis xav rov qab mus rau qhov chaw. Directivity (Ntau dua los yog sib npaug rau 55 dB) tiv thaiv cov teeb liab los ntawm kev tawm ntawm cov chaw nres nkoj tawm. Ob qhov kev ntsuas tseem ceeb hauv cov tes hauj lwm zoo. Kev coj tsis zoo tuaj yeem ua rau muaj kev sib tham ntawm cov neeg siv khoom ntawm tib ceg PON - qhov tsis tshua muaj tab sis tsis ua haujlwm tiag tiag.
Xaiv lub ntim zoo: Ib tsob ntoo txiav txim siab
Qhov no yog qhov uas ntau tus engineers tau daig. Lub splitter nti nws tus kheej yog tib yam; qhov txawv yog li cas nws tau ntim, uas txiav txim siab qhov twg thiab koj tuaj yeem nruab nws li cas. Hauv qab no yog plaub hom ntim ntau tshaj plaws, txhua qhov muaj qhov tseeb "zoo tshaj plaws" qhov xwm txheej.
Liab qab Fiber PLC Splitter - rau Tight Spaces thiab Custom Splicing
Raws li lub npe qhia, ib tug liab qab fiber ntau splitter tsis muaj vaj tse thiab tsis muaj connectors ntawm qhov kawg. Cov tswv yim thiab cov zis fibers raug nthuav tawm raws li 250 μm lossis 900 μm pigtails. Nws qhov loj me kom zoo dua yog qhov pom tseeb: nws yuav luag tsis muaj qhov chaw, ua rau nws zoo tagnrho rau kev teeb tsa hauv splice kaw, lub thawv davhlau ya nyob twg, lossis ib qho chaw kaw qhov twg koj twb tau ua fusion splicing.
Thaum twg los xaiv qhov no: Koj tab tom tsim ib qho me me faib ntawm hauv ib qho kev sib txuas uas twb muaj lawm kaw qhov twg txhua millimeter suav. Lub splitter yuav raug spliced ncaj qha rau feeder thiab poob fibers, yog li connectors yuav redundant. Zam hom no yog tias koj cov neeg ua haujlwm hauv teb tsis muaj kev paub txog kev cuam tshuam 250 μm fibers - lawv yog cov muag heev thiab yooj yim tawg.

Blockless (Mini Module) PLC Splitter - Qhov Qab Zib Spot rau Cov Thawv Xa Khoom

Qee lub sij hawm hu ua mini module lossis blockless splitter, qhov ntim no muaj qhov nruab nrab nruab nrab ntawm liab qab fiber ntau thiab tag nrho cov ntaub ntawv. Nws muab kev tiv thaiv fiber ntau dua li liab qab fiber ntau thaum tseem compact txaus kom haum rau hauv cov thawv me me. Cov qauv tsim tsis muaj qhov thaiv feem ntau muaj 0.9 hli tsis muaj fiber ntau pigtails thiab tuaj yeem ntsia tau rau hauv ntau lub thawv sib txuas, cov khoom siv hauv lub network, lossis txawm nyob hauv qhov sib txuas kaw thaum xav tau qee qhov kev tiv thaiv tab sis tag nrho ABS lub thawv yuav loj dhau.
When to choose this: You are deploying a medium‑density cabinet or a handhole terminal where space is tight but some cable management is required. Lub 0.9 hli pigtails muab rau koj txaus tuav lub zog yam tsis muaj ib lub thawv yas tag nrho.
ABS Box PLC Splitter - rau phab ntsa Mount thiab Sab nraum zoov txee
ABS lub thawv splitter lub tsev cov chips splitter nyob rau hauv ib tug compact yas enclosure (feem ntau nyob ib ncig ntawm 100 × 80 × 10 mm rau me me phua ratios) nrog pigtails tawm ob kawg. Qee cov qauv sib txuas SC / APC adapters ncaj qha rau hauv vaj tse, tig lub splitter rau hauv cov khoom siv plug-and-play.
Cov no yog cov neeg ua haujlwm ntawm FTTH kev faib khoom. Lawv muaj rugged txaus rau cov txee sab nraum zoov, compact txaus rau phab ntsa-mount enclosures, thiab ntau yam txaus kom haum rau ob qho tib si splicing thiab connectorized inputs. Ntau tus neeg ua haujlwm tsim qauv ntawm ABS lub thawv cais rau txhua daim ntawv thov cog sab nraum zoov vim tias lawv tawm tsam qhov sib npaug zoo ntawm kev tiv thaiv, nqi, thiab yooj yim ntawm kev tuav.
Thaum xaiv qhov no: Koj xav tau lub rugged, standalone splitter uas tuaj yeem txuas nrog cov hlua khi lossis cov ntsia hlau hauv lub thawv FTTH txheem. Cov ntawv txuas txuas (nrog SC / APC adapters ntawm cov tswv yim thiab cov zis) yog qhov tshwj xeeb tshaj yog thaum cov kws tshaj lij hauv teb tsis tau ntsib nrog splicing.

Plug-in (Cassette) Hom - rau ODF thiab High-Density Rack Environments

Rau cov chaw ua haujlwm hauv nruab nrab, cov chaw khaws ntaub ntawv, thiab cov chaw ua haujlwm headend, plug-in lossis cassette splitter yog qhov kev xaiv zoo. Cov splitters no yog nyob rau hauv ib tug modular cassette uas swb mus rau hauv ib tug 19-nti khib vaj huam sib luag (feem ntau LGX-tshaj) nrog rau thaj panels thiab lwm yam passive Cheebtsam.
Thaum xaiv qhov no: Koj yog centralizing tag nrho cov splitting nyob rau hauv lub telco central chaw ua hauj lwm los yog headend. Cov qauv tsim qauv tso cai rau koj ntxiv lossis hloov cov splitters yam tsis muaj kev cuam tshuam cov kev txiav tawm uas twb muaj lawm, thiab daim ntawv cassette ua rau ODF huv si thiab kev tshaj lij.
Centralized vs. Distributed Splitting: Cov Lus Nug Ntawm Architecture
Tshaj li lub splitter nws tus kheej, koj yuav tsum txiav txim siab yuav ua li cas faib splitting thoob koj lub network. Qhov no yog qhov tseem ceeb FTTH tsim kev xaiv uas cuam tshuam rau kev siv fiber ntau, kev xa tawm tus nqi, thiab kev saib xyuas tsis yooj yim.
Hauv qhov chaw nruab nrab (ib theem) architecture, ib qho loj splitter (1 × 32 lossis 1 × 64) raug teeb tsa ntawm OLT qhov chaw lossis hauv lub txee nyob ze. Txhua tus neeg siv khoom siv fiber ntau khiav rov qab mus rau qhov sib cais ib leeg. Qhov no ua rau kev siv OLT chaw nres nkoj thiab ua kom yooj yim daws teeb meem. Txawm li cas los xij, nws siv ntau fiber ntau hauv kev faib tawm vim tias txhua lub tsev xav tau cov fiber ntau los ntawm qhov sib cais.
Hauv kev faib (cascade) architecture, kev sib cais tshwm sim hauv ob theem. Ib qho 1 × 4 lossis 1 × 8 splitter yog muab tso rau ntawm qhov chaw faib khoom, thiab theem nrab 1 × 8 lossis 1 × 16 splitters raug teeb tsa ze rau cov neeg siv khoom. Qhov no yuav tsum muaj fiber ntau tsawg tab sis nthuav qhia ntau cov ntsiab lus splice thiab qhov poob qis dua me ntsis. Qhov poob ntawm tus qauv cascade tuaj yeem kwv yees kwv yees los ntawm kev ntxiv qhov poob ntawm cov thawj thiab theem nrab splitters. Rau ib tug raug 1 × 8 + 1 × 8 cascade, tag nrho cov poob yog hais txog 10.5 dB + 10.5 dB=21 dB, uas yog tseem nyob rau hauv GPON pob nyiaj siv rau luv mus rau nruab nrab nrug.
Yuav txiav txim li cas- Hauv cov cheeb tsam nroog loj uas muaj cov neeg siv khoom siab ceev, kev sib cais hauv nruab nrab feem ntau ua haujlwm tau zoo vim tias cov khoom noj fiber ntau luv luv. Hauv kev sib txuas hauv suburban lossis nyob deb nroog, kev sib faib faib txo cov fiber ntau uas koj xav tau faus. Tsis muaj lus teb "txoj cai" thoob ntiaj teb - nws nyob ntawm koj qhov chaw tshwj xeeb thiab cov kev txwv capex.
Saib ze dua: Glory's PLC Splitter Portfolio
Hwjchim ci ntsa iab muaj ntau yam ntawm PLC splitters npog cov feem ntau ntim hom thiab sib faib piv siv nyob rau hauv FTTH tej yaam num hnub no. Thaum cov qauv qhia sib txawv, cov ntaub ntawv muaj xws li:
Lub Bare Fiber PLC Splitter series muab cov kev daws teeb meem zoo tshaj plaws rau cov neeg tsim khoom uas npaj yuav splice ncaj qha rau hauv cov thawv xa khoom uas twb muaj lawm lossis cov splice kaw. Muaj nyob rau hauv symmetrical split ratios ntawm 1 × 2 mus rau 1 × 64, nrog cov tswv yim thiab tso zis pigtails nyob rau hauv 250 μm los yog 900 μm configurations. Cov no feem ntau siv hauv micro-duct cable systems uas qhov chaw nyob ntawm tus nqi.
Rau cov ntawv thov uas yuav tsum muaj kev tiv thaiv fiber ntau yam tsis muaj qhov chaw, Blockless (Mini) PLC Splitter muab cov kev daws teeb meem uas tsis tshua muaj siab rau cov khoom siv network thiab cov thawv xa khoom, nrog rau kev xaiv ntawm 0.9 hli tsis fiber ntau pigtails. Hom no tau dhau los ua neeg nyiam heev rau txoj kev xa khoom txee vim tias nws muaj sia nyob ntawm kev tuav nruj thaum lub sijhawm teeb tsa.
ABS Box PLC Splitter kab yog tsim los rau phab ntsa-mount thiab sab nraum zoov txee. Cov ntaub thaiv npog (ntau qhov ntev nyob ntawm qhov sib faib) muaj 2.0 hli lossis 3.0 hli jacketed pigtails thiab muaj nyob nrog lossis tsis muaj SC / APC adapters ua ntej. Kev sib cais sib txawv ntawm 1 × 4 txog 1 × 64, npog ob qho tib si hauv nruab nrab thiab faib cov qauv. Lub connectorized version (nrog cov tswv yim thiab tso zis adapters) tso cai rau cov kws tshaj lij los ua cov kev sib pauv thiab ua si hauv feeb, uas yog qhov zoo dua rau cov neeg ua haujlwm tu.
Rau qhov chaw ua haujlwm hauv nruab nrab thiab khib-mount ib puag ncig, LGX Cassette thiab 1U Rack Mount PLC splitters muab cov qauv kev sib txuas ua ke. Cov plug-in cassettes no haum seamlessly nrog rau lwm cov khoom khib nyiab, ua rau lawv nyiam xaiv rau kev xa tawm loj loj. Ntau tus neeg ua haujlwm siv cov kab ntawv no hauv lawv lub chaw haujlwm hauv nruab nrab ODFs los muab faib cov cim rau ntau qhov chaw GPON.
|
Hom Splitter |
Hom Siv Case |
Ntsiab Feature |
Zoo tshaj rau |
|
Fiber ntau |
Splice kaw, terminal thawv |
Tsawg hneev taw, 250/900 μm pigtails |
Kev sib xyaw ua ke, micro duct systems |
|
Blockless (Mini) |
Distribution boxes, txee |
0.9 hli pigtails, kev tiv thaiv zoo dua |
Txoj kev txee, handhole terminals |
|
ABS Box |
Phab ntsa mount, sab nraum zoov FTTx nodes |
Rugged box, yeem connectors |
Feem ntau FTTH faib cov ntsiab lus |
|
LGX Cassette / 1U Rack |
ODF, chaw ua haujlwm hauv nruab nrab, chaw zov me nyuam |
Standardized khib interface |
High density headend deployments |
Feem ntau yuam kev thiab yuav ua li cas zam lawv
Txawm tias muaj kev paub txog engineers qee zaum ua qhov tsis raug thaum xaiv lossis txhim kho PLC splitters. Ntawm no yog ob peb lub pitfalls tiag tiag.
Qhov yuam kev 1: Tsis quav ntsej lub pigtail ntev -Qee cov splitters tuaj nrog luv luv pigtails (piv txwv li, 1 meter). Yog tias koj lub thawv xa khoom muaj nws qhov chaw nres nkoj ntawm sab nraud, koj tuaj yeem xav tau qhov txuas txuas ntxiv. Nco ntsoov xyuas lub pigtail ntev tiv thaiv koj lub qhov rooj qhov rooj.
yuam kev 2: Siv cov fibers liab qab splitters hauv cov khoom ua teb- Bare fiber splitters yog txhais tau tias nyob rau hauv ib lub tsev tiv thaiv. Yog hais tias koj tso ib tug liab qab fiber ntau splitter ncaj qha rau hauv lub unsealed txee, ya raws thiab plua plav yuav nws thiaj li tawm tsam lub 250 μm fiber ntau txheej, ua rau micro-bending poob. Qhov no yog ib qho ua rau muaj kev cuam tshuam tsis sib xws uas nyuaj nrhiav.
Qhov yuam kev 3: Tshaj qhov qhia txog qhov sib cais- Ib qho 1 × 64 splitter yuav zoo li nws muab koj lub peev xwm tshaj plaws, tab sis nws kuj muaj qhov poob siab tshaj plaws (feem ntau Ntau dua lossis sib npaug li 20.5 dB). Tshwj tsis yog tias koj muaj qhov kev ncua deb heev thiab lub zog optics, koj tuaj yeem khiav tawm ntawm pob nyiaj siv hluav taws xob. Ntau lub FTTH ua tau zoo siv 1 × 32 raws li qhov siab tshaj plaws, nrog 1 × 16 rau ntau qhov chaw nyob deb nroog.
yuam kev 4: Tsis nco qab qhov kev ntsuam xyuas ib puag ncig- Tsis yog txhua lub thawv ABS yog tsim sib npaug. Rau cov khoom siv sab nraum zoov, xyuas kom lub splitter lub tsev yog ntsuas rau qhov ntsuas kub thiab UV raug. Rau underground handholes, koj xav tau kev tiv thaiv IP68. Ib qho yooj yim hauv tsev ABS lub thawv yuav tawg tsis pub dhau ib xyoos nyob rau hauv tshav ntuj ncaj qha.
yuam kev 5: Tsis tu cov connectorized splitters ua ntej deployment- Ib qho txuas txuas uas tuaj yeem ncaj qha los ntawm lub Hoobkas tseem tuaj yeem muaj plua plav ntawm lub ntsej muag kawg. Ib qho 0.3 dB poob los ntawm cov khoom siv qias neeg yog yooj yim zam nrog cov kauj ruam tu yooj yim. Ua nws ib feem ntawm koj cov txheej txheem installation.
Ib Qhov Kev Txiav Txim Siab Yooj Yim
Yog tias koj tsis paub meej qhov twg yuav xaiv, taug kev los ntawm cov kauj ruam no:
1.Txiav txim siab koj lub network architecture– Centralized lossis faib? Dab tsi sib faib piv koj cov peev nyiaj siv hluav taws xob tso cai? Yog tias koj tsis paub, pib nrog 1 × 32 - nws yog qhov pib tshaj plaws rau GPON.
2.Txheeb xyuas qhov chaw teeb tsa- Lub kaw lus kaw, txoj kev txee, lub hauv paus chaw ua haujlwm khib, lossis qhov tuav? Sib piv cov ntim rau ib puag ncig siv cov lus saum toj no.
3.Xaiv ntawm splice-on thiab connectorized - Cov kws tshaj lij puas yuav splice lub pigtails, lossis lawv puas yuav siv cov hlua txuas ua ntej txuas? Connectorized splitters raug nqi ntau dua tab sis txuag lub sijhawm teeb tsa.
4.Tshawb xyuas cov khoom siv xav tau- Rau khib-mount splitters, koj puas muaj lub vaj huam sib luag zoo? Rau liab qab fiber ntau splitters, koj puas muaj lub tes tsho kub-shrink thiab splice tais npaj?
5.Order ua ntej- Ua ntej yuav ntau pua tus splitters, xaj 5-10 units. Nruab lawv hauv koj qhov chaw ua haujlwm tiag tiag. Txheeb xyuas qhov poob qis nrog OTDR. Yog tias cov lej sib phim rau daim ntawv teev cov ntaub ntawv thiab qhov haum yog, ces ntsuas.
Txoj Cai Splitter yog ib qho uas haum rau koj txoj haujlwm tiag
Qhov zoo tshaj plaws PLC splitter tsis yog ib txwm yog ib qho uas muaj qhov poob qis tshaj plaws lossis tus nqi qis tshaj. Nws yog ib qho uas haum seamlessly rau hauv koj qhov tshwj xeeb xa tawm scenario. Thaum lub ntim khoom sib tw nrog lub kaw lus, qhov sib faib sib npaug sib npaug ntawm cov nyiaj siv kho qhov muag, thiab qhov ntev ntawm lub pigtail sib phim koj lub thawv layout, ib qho kev txo hwj chim ua haujlwm ntsiag to ua nws txoj hauj lwm rau nees nkaum xyoo yam tsis muaj ib qho kev tsis txaus siab.
Qhov ntawd yog qhov ntsuas tiag tiag ntawm qhov zoo splitter.