Ntu 1: Nkag siab Gel Sealing - Tus Qauv Niaj Hnub No
1.1 Gel Sealing yog dab tsi?

Gel sealing siv cov mos, elastic compound (feem ntau yog cov thermoplastic elastomer) uas yog mechanically compressed nyob ib ncig ntawm cables hauv lub kaw. Thaum lub kaw lus kaw lawm, cov gel ntws mus rau txhua qhov chaw ntawm lub tsho cable, tsim kom muaj 360℃watertight thiab plua plav- nruj barrier. Tsis zoo li cov gaskets nruj, gel yog ib nrab - kua uas tuaj yeem hloov mus rau qhov tsis sib xws ntawm cov kab hluav taws xob, cov kab sib txawv, thiab txawm tias ntau lub cables sib koom tib qhov chaw nres nkoj.
1.2 Yuav Ua Li Cas Piv rau Cov Txheej Txheem Txheej Txheem Txheej Txheem
|
Feature |
Thaum tshav kub kub Shrink |
Mechanical O Ring |
Gel Sealing |
|
Cov cuab yeej installation |
Rhaub rab phom los yog teeb |
Torque wrench |
Tsis muaj (tes nruj) |
|
Re nkag tau |
Tsis muaj (kev puas tsuaj) |
Yog lawm |
Yog (ntau zaus) |
|
Cable txoj kab uas hla yooj |
Ib qhov loj rau ib lub tes tsho |
Yuav tsum tau sib txawv grommets |
Dav dav hauv tib qhov chaw nres nkoj |
|
Foob zoo nrog cov kab sib xyaw |
pluag |
Nruab nrab |
Zoo heev ( ntws ncig) |
|
Kev txhawj xeeb txog kev laus |
Shrinkage raws sijhawm |
Roj hmab hardens, poob elasticity |
Tseem pliable rau xyoo lawm |
|
Kev kho teb |
Hloov tag nrho lub tes tsho |
Hloov gasket |
Kev kho tus kheej (gel ntws rov qab) |
Vim li cas cov cua sov tseem siv tau: Nws yog qhov muaj zog heev rau kev ruaj khov, tsis txhob -kom-tau- qhib splices (xws li, tob- faus lub cev cables).
Yog vim li cas mechanical O-rings yog ib txwm: Lawv yog re- nkag tau thiab nkag siab zoo, tab sis torque rhiab heev thiab roj hmab laus yog cov kev txwv tiag tiag.
Vim li cas gel sealing yeej rau feem ntau cov nroj tsuag sab nraud: Nws ua ke rov qab - nkag, cuab yeej - kev teeb tsa dawb, thiab cable- tus phooj ywg yoog raws.
1.3 Kev Tshawb Fawb Txog Tus Kheej-Kho Gel
High -cov gels zoo yog tsim los ntawm kev sib npaug ntawm viscosity, elasticity, thiab cohesion. Thaum koj thawb ib lub cable rau hauv gel- chaw nres nkoj, cov gel qhov chaw nyob ib ncig ntawm nws - tsis yog los ntawm kev txiav los yog kua muag, tab sis los ntawm ntws. Thaum koj tshem lub cable, gel lub ntuj cohesion rub nws rov qab rau hauv qhov khoob, kho qhov qhib. Qhov kev kho tus kheej no - kho tuaj yeem tshwm sim ntau zaus yam tsis muaj kev ntsuas qhov degradation ntawm sealing kev ua tau zoo.
Ntxiv mus, gel tsis tas yuav deform. Nws tseem mos dhau qhov kub ntawm qhov dav (–40℃rau +65℃, lossis dav dua rau cov qauv tshwj xeeb). Nyob rau hauv huab cua txias, pheej yig gels ua nkig thiab tawg; Thaum tshav kub kub, qis- zoo gels yuav ooze tawm. Hwm gels nyob pliable, tswj lub siab tas li tiv thaiv lub tsho cable.
1.4 Vim li cas IP68 thiab Dav Dav Kub Kub Tsis Muaj Kev Sib Tham
Ib lub thawv tuaj yeem thov "gel kaw," tab sis tsis muaj ntawv pov thawj zoo, cov lus cog tseg yog khoob. Nrhiav:
• IP68 - Plua plav- nruj thiab muaj peev xwm txuas ntxiv mus rau hauv dej (feem ntau 1-2 meters, 7 hnub). Qhov no guarantees ciaj sia nyob rau hauv dej nyab manholes, los nag hnyav, los yog ib ntus submersion.
• Kev khiav hauj lwm kub - Ntawm -40℃rau +65℃(los yog siab dua). Cov gel yuav tsum tsis txhob khov nyob rau hauv lub caij ntuj no arctic los yog khiav zoo li zib mu nyob rau hauv suab puam summers.
• UV-stabilized vaj tse - Tiv thaiv kev tawg thiab daj tom qab lub hnub ci ncaj qha rau xyoo.
• Corrosion-cov ntaub ntawv tiv taus - Qhov tseem ceeb rau thaj chaw ntug hiav txwv lossis chaw lag luam.
Thaum tag nrho cov no tau sib xyaw ua ke, gel- kaw kaw tuaj yeem yooj yim outlast lub network nws tus kheej - 25 xyoo lossis ntau dua.
1.5 Thaum twg Gel Sealing qhov kev xaiv zoo tshaj?
Gel sealing yog tshwj xeeb tshaj yog muaj txiaj ntsig hauv cov xwm txheej hauv qab no:
• FTTH faib cov nodes - Kev hloov pauv tsis tu ncua, hom kab sib xyaw (piv txwv li, poob qis, me me-inch feeder).
• Manhole los yog handhole installations - txaus ntshai ntawm cov dej sawv; xav tau rov- nkag mus ntxiv rau cov neeg siv npe.
• Aerial (ncej-mounted) kaw - Kev vibration thiab kub caij tsheb kauj vab; tsis muaj cua sov qhov chaw.
• Kev kho mob xwm txheej ceev – ceev, cuab yeej -tsawg rov qhib thiab rov ua dua.
• Cov tes hauj lwm uas siv ntau tus neeg muag khoom siv cables - Gel cov chaw nres nkoj txais dav dav sib txawv yam tsis hloov qhov chaw.
Ntu 2: HLORY Gel Sealed Enclosures - Ob Tus Qauv rau Txhua Qhov Chaw Network
GLORY muaj ob qho ntxiv gel- kaw cov ntaub ntawv kaw uas ua ke npog tag nrho ODN spectrum: los ntawm siab - lub cev muaj peev xwm splicing mus rau compact drop terminal boxes.
2.1 FOSC 450 B6 - Siab-Capacity Gel Sealed Splice Kaw
Tsim los rau: Feeder cables, nraub qaum splices, loj-fiber- suav cov ntsiab lus faib.
Cov ntsiab lus tseem ceeb:
|
Parameter |
Tus nqi |
|
Splice muaj peev xwm (ib leeg) |
Txog 144 fibers (6 tais, 24F txhua) |
|
Splice muaj peev xwm (mass fusion) |
Txog 288 fibers (4 lub tais) |
|
Cable chaw nres nkoj |
6 chaw nres nkoj (0.35 "- 1.0" / 9-25 mm) |
|
sealing hom |
Compressed gel kawg- thooj, cuab yeej- nruj |
|
Slack ruaj khov |
Hlau slack pob tawb (yeem) |
|
Hauv av |
Kev xaiv hauv av pub los ntawm lugs (0 lossis 3) |
|
Valve |
Built in rau flash test (standard) |
|
Mounting |
Aerial, phab ntsa, ncej (cov khoom siv ntxiv muaj) |

Dab tsi ua rau nws tshwj xeeb:
• Lub compressed gel kawg-daim yog qhib los ntawm tig tus Tsov tus tw clockwise - tsis muaj cov cuab yeej tshwj xeeb, tsuas yog ib lub hau ntswj ntxig rau leverage.
• Qhov kaw yog tag nrho re-enterable; unscrewing lub gel tso tawm lub foob.
• Lub pob tawb hlau tso cai rau kev khaws cia ntawm cov hlua khi, qhov tseem ceeb rau nruab nrab - ncua kev nkag.
• Ua haujlwm nrog xoob buffer raj (LBT) thiab lub hauv paus tub ntxhais raj (CCT) cables, suav nrog ribbon fiber ntau.
• Nws tuaj yeem ntsia tau rau hauv huab cua, pedestal, handhole, lossis ncaj qha faus (thaum kaw kom zoo).
Zoo tagnrho rau:
• Ntev -cov kab trunk splices
• Central chaw ua hauj lwm tawm nodes
• Siab -Qhov ceev FTTH feeder ntsiab lus
• Txhua qhov chaw koj xav tau splice 48 mus rau 144 fibers nrog chav rau yav tom ntej nthuav dav.
2.2 GZS-SW-0402 – Compact Gel Sealed Terminal Box rau FTTH Drops

Tsim los rau: Kawg-meter faib, MDU cov ntsiab lus nkag, cov txee rau hauv txoj kev, thiab phab ntsa / ncej- mounted poob terminals.
Cov ntsiab lus tseem ceeb:
|
Parameter |
Tus nqi |
|
Qhov ntev |
258 × 150 × 95 hli |
|
Qhov hnyav |
0.6 0.8 kg ib |
|
Khoom siv |
PP + GF (UV stabilized) |
|
sealing hom |
Mechanical gel + silicone roj hmab |
|
Kev tiv thaiv |
IP68 + IK10 (plua plav / dej + cuam tshuam resistant) |
|
Splice muaj peev xwm |
24 fibers |
|
Main cable ports |
3 hauv / tawm (max Ø15 mm) |
|
Tshem cov kab hluav taws xob |
Round Tsawg dua lossis sib npaug Ø6 hli, tiaj tus Tsawg dua lossis sib npaug li 8 × 4.5 hli / 5 × 2 hli |
|
Splitter (yeem) |
1 × 4 lossis 1 × 8 PLC |
|
Adapters |
4 × SC / APC (ib zaug lossis duplex) |
|
Mounting |
Manhole, pedestal, aerial, phab ntsa mounted |
Dab tsi ua rau nws tshwj xeeb:
• Qhwv-nyob ib ncig ntawm kab nkag- poob cables tuaj yeem ntsia tau yam tsis muaj kev txiav thiab xov xaus los ntawm lub qhov me me, ua rau kev ua haujlwm nrawm nrawm.
• Hinged cover- muab kev ywj pheej nkag mus rau qhov chaw poob cable txuas yam tsis tau nthuav tawm tag nrho lub thawv.
• Cais ib cheeb tsam- looped cia, splicing, thiab patching yog lub cev sib cais kom yooj yim tswj.
• Tshem tau fiber ntau tswj seem- ua ntej- teeb tsa sab hauv tsev, tom qab ntawd nruab rau hauv thaj chaw.
• Tool-dawb gel foob- mechanical compression latches hloov cov cuab yeej torque.
• IK10 cuam tshuam tsis kam- tiv thaiv kev tsoo tsoo ntawm tus ncej lossis hauv qhov tuav.
Zoo tagnrho rau:
• FTTH faib cov ntsiab lus (pedestal, ncej, phab ntsa)
• 5G me me ntawm tes fronthaul terminations
• MDU hauv qab daus lossis hauv pem teb faib
• Nyob deb nroog broadband tej yaam num uas ceev, txhim khu kev qha installation yog yuav tsum tau.
Ntu 3: Daim Ntawv Qhia Daim Ntawv Thov - Qhov twg Enclosure rau Qhov Node?
|
Network Node |
Hom Fiber suav |
Cov khoom pom zoo |
Qhov Tseem Ceeb |
|
Ntev ntev lub cev splice |
48 – 288 |
FOSC 450 B6 |
Muaj peev xwm, slack pob tawb, 6 ports |
|
Central chaw ua hauj lwm feeder cable tawm |
24 – 144 |
FOSC 450 B6 |
Re enterable, grounding kev xaiv |
|
Txoj kev txee / pedestal faib |
12 – 24 |
GZS-SW-0402 |
Compact, IP68+IK10, 1:4/1:8 splitter npaj txhij |
|
Tsev nkag (MDU) |
8 – 24 |
GZS-SW-0402 |
Phab ntsa mountable, hinged npog kom yooj yim poob nkag |
|
Tus neeg siv poob davhlau ya nyob twg (ib lub tsev) |
1 – 4 |
GZS-SW-0402 |
Me me hneev taw, qhwv ib ncig ntawm kev nkag nkag |
|
Rural ncej mounted splice |
12 – 48 |
Los yog |
FOSC rau suav loj, GZS rau me |
Ib feem4: Tag Nrho Cov Tswv Cuab (TCO) Qhov Zoo ntawm Gel Sealing
Gel-cov ntaub ntawv kaw feem ntau muaj tus nqi siab dua li cov cua sov yooj yim-shrink kaw, tab sis lawv txo qis rau lub sij hawm ntev - cov nuj nqis:
• Kev teeb tsa ua haujlwm - Cov cuab yeej-dawb, gel sealing yuav siv sij hawm feeb rau ib qhov kaw, piv rau 15-30 feeb rau cua sov (nrog rau lub teeb thiab txias).
• Re- tus nqi nkag - Ntxiv ib qho fiber ntau rau qhov cua sov-shrink kaw yuav tsum tau rhuav tshem thiab hloov tag nrho lub foob. Gel kaw: qhib, ntxiv cable, kaw - 5 feeb.
• Kev txo cov khoom lag luam - Ib qho gel kaw txais ntau txoj kab uas hla, txo tus naj npawb ntawm SKUs koj yuav tsum tau npaj.
• Kev zam tsis tau - IP68 thiab tus kheej- kho gel txo cov dej- cuam tshuam txog kev ua tsis tiav, txuag cov tsheb thauj khoom kim.
Rau ib txoj haujlwm FTTH raug nrog 500 sab nraum zoov, hloov los ntawm tshav kub ntsws mus rau gel sealing tuaj yeem txuag tau 40-60% hauv kev teeb tsa kev ua haujlwm thiab ntau dua 70% ntawm cov nqi tu yav tom ntej. Tias yog vim li cas ntau tus neeg teb xov tooj tam sim no qhia gel sealing raws li lawv lub neej ntawd rau kev faib tawm thiab xa daim ntawv thov.
Xaus: Xaiv Gel, Xaiv Certainty
Gel sealing tsis yog ib qho cuab yeej technology. Nws tau loj hlob mus rau hauv ib qho kev txhim khu kev qha, teb- tus phooj ywg, thiab tus nqi- tus qauv zoo rau cov khoom siv fiber ntau sab nraum zoov. Txawm hais tias koj xav tau 144 fibers rau ntawm lub cev kab (FOSC 450 B6) lossis txiav tawm ib qho kev poob qis hauv tsev (GZS-SW-0402), GLORY's gel-cov ntaub thaiv npog xa tawm IP68 kev tiv thaiv, dav kub siab, thiab tsis muaj kev ywj pheej rov qab.
Npaj los txhim kho koj cov nroj tsuag sab nraud nrog gel sealing? Tiv tauj peb rau cov qauv, cov ntaub ntawv qhia kev, lossis kev tsom xam TCO rau koj qhov project tom ntej. Koj lub network yuav ua tsaug rau koj ntau xyoo lawm.