Handhole vs Manhole rau Fiber: Ib qho -Lord Spec Kev txiav txim siab uas ntsiag to teev koj tus nqi mus ib txhis

Jun 01, 2026

Tso lus

Fiber Optic Manhole

Ob lo lus ntawm daim duab - "handhole" lossis "manhole" - zoo li hloov pauv tau rau tus neeg yuav khoom nyeem daim nqi ntawm cov ntaub ntawv. Lawv tsis yog. Ib qho ntawm lawv yuav tsum tau ua rau koj cov neeg ua haujlwm txhim kho kom nqa tau qhov chaw nyob tsis pub dhau - daim ntawv tso cai nkag mus, lub roj saib xyuas, lub koob yees duab rov qab, thiab cov neeg ua haujlwm cob qhia sawv saib sab saum toj txhua zaus lub hau tawm. Lwm tus yog tus kws tshaj lij qhib nrog tus nuv thiab ncav cuag nrog ob txhais tes. Tus nqi sib txawv tsis tshwm sim hauv kev yuav khoom. Nws tshwm sim thoob plaws kaum xyoo ntawm lub tsheb rolls - thiab los ntawm ces qhov kev txiav txim yog faus rau hauv ib txoj kev.

Glory Optical tau tsim thiab xa tawm fiber ntau enclosures thiabsplice kawrau cov neeg ua haujlwm hauv50+ lub teb chawstxij li xyoo 2008, thiab cov lus sib txawv tsuas yog ib feem ntawm qhov teeb meem. Tus qauv costlier: ib qhov project spec uas sau "manhole" hla 40–50 cov ntsiab lus nkag mus rau hauv cheeb tsam FTTH txoj kev faib khoom uas tsis muaj nyob hauv -vault nkag mus ua haujlwm yog ib txwm xav tau. Cov ntaub ntawv khaws cia los ntawm hom kev tsim ua ib txwm muaj nyob rau ntawm - mus ntsib lub sijhawm ntawm 2.0–2.5 teev - tso cai kev npaj, kev sim huab cua, dual- cov neeg ua haujlwm yuav tsum tau ua - tawm tsam 40–50 feeb rau kev ua haujlwm sib npaug. Ntawm US fiber ntau- neeg coob tus nqi ntawm $65–85 rau ib tus neeg-teev, qhov chaw nyob ib leeg -cov nyiaj siv ua haujlwm ib leeg rov qab los ntawm pej xeem- tus nqi sib txawv ntawm manhole thiab handhole specification hauv thawj 12-18 lub hlis ntawm kev ua haujlwm. Tus qauv rov tshwm sim zaum ob: IP66-ratedinline splice kawmuab tso rau hauv ib lub pob zeb- hauv qab tes hauv av nplaum, tsis muaj dej. Tom qab thawj lub caij ntub dej, OTDR cov cim ntawm cov chaw vault no qhia tau tias qhov ntsuas tau nkag tau- poob nce ntxiv thaum lub voj voog kaw ntawm dej nyab thiab qhuav; lub retrofit - hloov nyob rau hauv - tshwj xeeb kaw thiab ntxiv cov kua dej - feem ntau khiav 30–45% ntawm tus thawj vault installation nqi. Ob qho kev ua tsis tiav yog pib los ntawm cov khoom siv. Lawv pib nrog ib qho hauv qab - lo lus tshwj xeeb.

Phau ntawv no kho qhov ntawd. Nws piav qhia meej tias lub qhov tuav, lub qhov taub, thiab "fiber vault" yog dab tsi; ib qho kev sib txawv uas tsav tag nrho kev txiav txim siab; yuav ua li cas lub load- ntsuas tus qauv txhua tus quotes tiag tiag ua haujlwm (thiab li cas nplooj ntawv sib tw nrov tau txais nws tsis raug); thiab yuav ua li cas tus kws tshaj lij kev muag khoom xaiv txoj cai enclosure - thiab txoj cai kaw kom muab tso rau hauv nws - rau txoj kev tiag.

Yog tias koj tsuas nco ib kab lus:koj tsis xaiv ib lub thawv, koj tab tom xaiv ib tug saib xyuas tswj - thiab "handhole vs manhole" yog lo lus uas xauv nws nyob rau hauv.

Ua ntej, cov ntsiab lus - vim hais tias ib nrab ntawm kev tsis sib haum xeeb yog cov lus

Ua ntej leej twg tuaj yeem sib piv ib lub qhov rau hauv lub qhov manhole, peb yuav tsum pom zoo rau cov lus uas txhais tau tias, vim tias kev lag luam tsis muaj. Tib lub thawv faus yog hu ua tsib yam nyob ntawm seb leej twg hais lus thiab qhov twg lawv tau kawm.

Lub sij hawm Nws feem ntau txhais li cas Qhov twg koj mam li hnov
Handhole Ib qho chaw ntiav hauv av nkag los ntawm qhov chaw; tus kws kho mob ncav cuag nrog lawv txhais tes, tsis muaj lub cev nkag North American telecom, NEC- cuam tshuam specs
Fiber ntau vault / fiber optic vault Feem ntau yog ib lub ntsiab lus rau ib lub tes tsho; Qee zaum qhov loj dua, nkag tau yooj yim -txheeb xyuas lub hom phiaj siv US cov cab kuj thiab cov nqi hluav taws xob specs; kev lag luam
Rub lub thawv / rub lub qhov Ib lub tes tsho siv feem ntau ua ib qho cable - rub cov ntsiab lus nruab nrab, tsis yog rau kev sib txuas Hluav taws xob thiab ITS/txoj kev crews
Joint pit / splice qhov Ib tug handhole loj los tuav ib tug splice kaw thiab slack loops UK / Commonwealth / intra-lub nroog OSP specs
Manhole (telecom) Ib tug tob, nkag mus rau hauv av chamber tus neeg ua haujlwm nce mus rau ntawm tus ntaiv rau splice thiab khib cable Carrier feeder routes, legacy copper plant, loj duct banks

Tib yam khoom siv lub cev mus nyob hauv ntau lub npe. Qhov kev ntseeg siab tsis meej pem tsis yog lo lus - nws yog seb tus neeg puas yuav nkag mus.

 

 

Kev lag luam kev teeb tsa kev taw qhia thav duab qhov sib txawv kom meej: muaj ntau zaustsis muaj qhov sib txawv hauv kev tsim khonruab nrab ntawm lub qhov me me thiab lub qhov loj loj - lawv muaj npe rau cov haujlwm uas lawv ua. Lub manhole yog lub chamber qhov twgfiber ntau txuas thiab sib koom ua ke - kaw installationtshwm sim nrog tus neeg ua haujlwm sab hauv; lub handhole yog siv raukhaws slack cable loops thiab ua raws li lub rub / nkag mustsis nkag. Qhov kev ua haujlwm sib cais - nkag mus ua haujlwm vs. ncav cuag - yog tag nrho cov kev ua si.

 

Engineer daim ntawv

Thaum ib qho spec hais tias "fiber vault," tsis txhob xav tias qhov handhole thiab tsis xav tias manhole. Nug ib lo lus nug:puas yog tus neeg xav kom lub cev nkag mus ua haujlwm?Cov lus teb txiav txim siab txog kev tso cai tswjfwm, cov neeg coob coob, qhov ntsuas kev thauj khoom uas koj tuaj yeem khiav tawm, thiab kwv yees li ib nrab ntawm tus nqi ntawm lub neej. Lo lus ntawm daim duab yog qhov tsawg tshaj plaws kev ntseeg siab hauv kev sib tham.

Ib qho kev sib txawv uas txiav txim siab txhua yam: nkag mus rau lub hom phiaj

Ntawm no yog cov qauv kev puas siab puas ntsws uas npaj tag nrho cov ncauj lus. Txhua qhov kev nkag mus rau hauv av ntawm txoj kev fiber ntau poob rau hauv ib qho ntawm ob lub thoob, thiab qhov tsis meej pem ob yog lub hauv paus ntawm yuav luag txhua qhov kev siv nyiaj ntau dhau thiab kev nyab xeeb nrhiav pom peb pom sab nraud - cog khoom.

Mus txog - hauv kev nkag (lub qhov rooj / lub rooj zaum / rub lub thawv).Cov qauv yog ntiav txaus - feem ntau nrog qhov tob sab hauv ntawm qhov kev txiav txim ntawm ob txhais taw lossis tsawg dua rau qhov me me - uas tus kws tshaj lij tau txhos caug ntawm qhov chaw, qhib lub hau, thiab ua txhua yam haujlwm (rub, slack cia, splice- kaw qhov chaw thiab rov- nkag) nrog lawv txhais tes hauv lub thawv. Lawv lub cev yeej tsis nkag mus. Tsis muaj ntaiv. Tsis muaj nqis.

Nkag mus rau hauv lub manhole.Cov qauv yog qhov loj thiab sib sib zog nqus txaus uas tus neeg ua haujlwm nce toj ib tus ntaiv thiab sawv sab hauv rau racking cable thiab splice. Lub sijhawm tib neeg lub cev nkag mus rau hauv chav dej hauv av uas tsis yog tsim los rau kev nyob tsis tu ncua, lub cev sib txawv ntawm txoj cai lij choj kev nyab xeeb hloov mus.

Qhov no yog qhov counterintuitive uas ntes cov neeg yuav khoom uas xav tias lawv tsuas yog xaiv "lub thawv loj dua":tus nqi ntawm ib lub manhole yog dominated tsis yog los ntawm cov pob zeb tab sis los ntawm kev nkag.Cov qauv pej xeem kim dua, yog. Tab sis tus nqi rov ua dua - qhov chaw uas sib txuas hauv lub neej ntawm lub network - yog tias txhua qhov kev mus ntsib dhau los ua ib qho kev txwv - chaw ua haujlwm.

Yog vim li cas ib tug manhole yog ib tug confined qhov chaw - thiab ib tug handhole feem ntau tsis yog

Rau txhua tus neeg ua haujlwm khiav lawv tus kheej cov neeg ua haujlwm tu, ntu no yog qhov txiaj ntsig loj tshaj plaws ntawm cov ncauj lus ntawm nplooj ntawv no.

Raws li Asmeskas txoj cai lij choj kev nyab xeeb kev ua haujlwm, lub xov tooj ntawm tes yog, los ntawm kev txhais, qhov chaw kaw: nws loj txaus nkag mus thiab ua haujlwm, muaj kev txwv kev nkag thiab tawm, thiab tsis yog tsim los rau kev nyob tsis tu ncua. Tsoom fwv teb chaws regulator teevunderground vaults thiab manholes meej meej ntawm cov chaw kaw. Thaum qhov chaw zoo li no tuaj yeem muaj huab cua txaus ntshai - thiab qhov chaw hauv xov tooj cua hauv av tuaj yeem sau tau raws nraim li - nws dhau los uatso cai-yuav tsum tau muaj chaw nyob.

Telecom ua haujlwm muaj nws tus kheej tsim qauv. Kev ua haujlwm hauv manholes thiab hauv av vaults feem ntau yog tswj hwm los ntawmKev sib txuas lus tus qauv ntawm 29 CFR 1910.268(o), uas teeb tsa cov cai rau kev saib xyuas qhov qhib, ntsuas huab cua thiab qhov cua ua ntej nkag mus, thiab ntaiv nkag. Daim ntawv tso cai dav dav-yuav tsum tau txwv- qhov chaw tus qauv, 29 CFR 1910.146, siv tau thaum cov kev pabcuam hauv xovtooj tsis tuaj yeem ua rau qhov chaw nyab xeeb - piv txwv li, thaum lub qhov quav muaj cov co toxins. Txawm li cas los xij, kev lav phib xaub yog tiag tiag: kuaj cov huab cua ua ntej nkag, qhov cua, tus neeg saib xyuas, thiab kev npaj cawm.

Txhais qhov ntawd rau hauv kev muaj tiag ntawm kev yuav khoom. Ib tug manhole splice tuaj xyuas tsis yog ib tus kws tshaj lij nrog lub van. Nws yog, yam tsawg kawg nkaus:

  • Ibnkagua haujlwm sab hauv;
  • Ibtus neeg saib xyuasnyob ntawm qhov chaw uas tsis nkag mus thiab tsis tawm;
  • Kev sim huab cua(oxygen, flammable gas, toxic gas) ua ntej thiab thaum lub sij hawm nkag;
  • Qhov cuacov khoom siv, kev saib xyuas tsheb ncig ntawm lub hau qhib, thiab acawm/retrievalmuaj peev xwm.

Ib lub tes tsho splice mus ntsib - qhov chaw kaw yog nqa mus rau saum npoo, rov- nkag, thiab qis rov qab - yog ib tus kws tshaj lij nrog cov cuab yeej tes.Ob tug neeg thiab ib daim ntawv tso cai rau ib tug neeg thiab ib tug nuv.Muab ntau qhov ntawd hla txhua qhov kev saib xyuas ntau dua 20- xyoo khoom vaj khoom tsev lub neej thiab "khoom kim" manhole dhau los ua cov khoom lag luam-tus nqi tseem ceeb ntawm txoj kev, thaum lub thawv nws tus kheej yog qhov yuam kev sib npaug.

Confined -qhov chaw tus nqi lej lej - los ntawm cov lej

 

 

Tus nqi Handhole (nce -in) Manhole (tso cai- nkag)
Cov neeg coob coob tuaj ntsib 1 tus kws tshaj lij 2 yam tsawg kawg nkaus (entrant + attendant)
Nkag mus rau saum taub hau Tsis muaj 45-90 min (kev tso cai prep, atmospheric test, cua teeb)
Lub sij hawm mus ntsib 40–60 feeb 2.0-2.5 Nws
Kwv yees tus neeg ua haujlwm tus nqi ib zaug1 $50–75 $280–375
Rau -xov xwm hwm - +$230–$300

 

Rau 30- nkag mus- taw tes faib txoj hauv kev nrog plaub qhov xwm txheej ntawm kev saib xyuas hauv ib lub xyoo: dhau 20-xyoo lub neej khoom vaj khoom tsev, qhov chaw txwv tsis pub siv nyiaj ntxiv$552,000–$720,000 hauv cov neeg ua haujlwm- tawm tsam ib qho -lub sij hawm pej xeem tus nqi sib txawv ntawm kwv yees li $45,000–$90,000 ntawm qhov sib npaug manhole thiab handhole specifications. Tus nqi pej xeem yog tus lej tsawg dua los ntawm ib qho ntawm yim mus rau kaum ob.

Lub neej - tus nqi qis tus neeg yuav khoom tsis nco

Qhia lub manhole tsuas yog qhov uas koj xav tau ib tus neeg ua haujlwm tiag tiag hauv - suav cable siab, lub tsev txhab nyiaj loj, nquag re-spling ntawm feeder cable, lossis rub cov tensions uas xav tau hauv -vault rigging. Txhua qhov chaw kaw qhov sib txuas tuaj yeem nqa mus rau saum npoo, rov- nkag, thiab xa rov qab, lub qhov tuav tuav txhua qhov kev mus ntsib yav tom ntej tawm ntawm qhov chaw txwv - txoj cai lij choj. Txoj cai enclosure yog qhov tsawg tshaj plaws uas tseem cia cov haujlwm tshwm sim los ntawm qhov chaw. Qhov no tsis yog hais txog kev txuag ntawm pob zeb - nws yog hais txog tsis yuav daim ntawv tso cai- yuav tsum tau muaj kev saib xyuas rau hauv txhua lub tsheb thauj khoom yav tom ntej.

Load rating: yuav ua li cas ANSI / SCTE 77 ua tau tiag tiag (thiab yuav ua li cas ib nplooj ntawv nrov tau txais nws tsis ncaj ncees lawm)

Ob lub handholes thiab manholes nqa ib qho kev ntaus nqi, thiab qhov no yog qhov uas cov neeg yuav khoom tsis tu ncua tau txais cov lej uas muaj txiaj ntsig zoo tab sis ntsiag to tsis raug. Cov ntaub ntawv raug:

Hauv North America, kev tswj hwm kev ua haujlwm tshwj xeeb rau tsis yog - txhob txwm tshaj tawm - tsheb thauj mus los hauv av yogANSI/SCTE 77, tsim los ntawm ANSI thiab Society of Cable Telecommunications Engineers thiab hloov kho ib ntus. Raws li tus qauv tshaj tawm thiab cov tuam txhab lag luam loj tau piav qhia nws, tus nqi specs kev ncaj ncees los ntawm ib qhopeb- txoj hauj lwm xeem - lateral sidewall, ntsug sidewall, thiab npog ntsug load- uas simulates lub tsheb los ze thiab tsav lub thawv.

Cov lej lej - thiab tus qauv tsim-vs- xeem-load nthuav dav txhua tus poob

Qhov tseeb tseem ceeb:tier tooj yog tus tsim load nyob rau hauv ntau txhiab phaus, thiab txhua tier muaj ib tug nyias xeem load uas yog 50% siab dua.Raws li ib qho ntawm cov chaw tsim khoom xaiv cov lus qhia muab tso rau qhov tseeb, qhovtier tus naj npawb yog qhov nominal tsim load × 1,000 phaus, thiab coj mus kuaj load yog 50% ntau dua. Kev hais tawm tsuas yog ib qho ntawm ob tus lej - lossis sib txuas tus lej tsis raug nrog qib - yog ib qho yuam kev feem ntau ntawm nplooj ntawv xa khoom.

ANSI/SCTE 77 tiers npog tsis yog - txhob txwm tshaj tawm kev tsheb khiav nkaus xwb. Rau ib lub thawv uas zaum hauv txoj kev taug kev, SCTE 77 tsis yog tus qauv zoo - koj xav tau AASHTO H-20 / H-25. Ib tus neeg muag khoom muab "Tier 22" rau daim ntawv thov nyob rau hauv txoj kab tau ua yuam kev ntawm cov qauv.

 

Tier Tsim load Test load (× 1.5) Tej daim ntawv thov
Qib 5 5,000 lb 7,500 Ib Txoj kev taug kev, thaj chaw neeg taug kev deb ntawm qhov thaiv
Qib 8 8,000 Ib 12,000 lb Kev taug kev nrog teeb pom kev zoo- tsheb txaus ntshai
Qib 15 15,000 lb 22,500 Ib Kev tsav tsheb, chaw nres tsheb, tawm -txoj kev - lub tsheb thauj neeg caij tsheb
Qib 22 22,000 Ib 33,750 Ib Kev tsav tsheb, chaw nres tsheb, tawm - txoj kev - qee zaus tsheb thauj khoom / tsheb loj
UAS H-20 Cais tus qauv Kev txiav txim siabtsheb khiav - nyob rau hauv txoj kev, txoj kev loj, paved lub xub pwg nyom

 

Lub ntsiab lus meej - thiab qhov ntsuas kev ntseeg siab ntsiag to

Qhov yuam kev tshwm sim ntawm ntau nplooj ntawv xa khoom: ib lub thawv 12 × 12 × 18 teev raws li "Tier 15" thiab 17 × 30 × 24 lub thawv teev raws li "Tier 22," zoo li yog cov khoom ntawm qhov ntev. Nws tsis yog. Load tier yog ib qho kev sim ntawm cov qauv kev ua tau zoo hauv chav kawm ywj pheej ntawm lub thawv loj - lub thawv compact thiab lub thawv loj loj ua rau tib lub ntsiab lus tuaj yeem ua tiav Tier 22, thiab cov pwm ntau lawm tuaj yeem muab rau hauv ntau qib nyob ntawm cov khoom siv thiab lub hau sib dhos. Thaum tus neeg muag khoom sib txuas tier rau qhov ntev, los yog quotes qhov kev xeem load zoo li nws yog tus tsim load (los yog vice versa), nws qhia tau hais tias tus sau tsis tau nyeem ANSI/SCTE 77. Cov no yog cov ntsiab lus raws nraim uas qhia tau hais tias ib tug specification yog grounded nyob rau hauv tus qauv los yog paraphrased los ntawm ib daim ntawv qhia - thiab lawv muaj qhov tshwm sim tiag tiag thaum lub tsheb thauj khoom tsis ua haujlwm.

Ib qho ntxiv nuance uas catches specifiers: ib lub thawv Tier 22 tsis cia li txaus siab Tier 15. Qhov peb - txoj hauj lwm xeem geometry txawv ntawm tiers, thiabib yam khoom yuav tsum raug txheeb xyuas kom tau raws li txhua qib nws thov nws tus kheej. Nug rau qib (s) cov khoom tshwj xeeb tau sim rau - tsis yog qhov kev xav tias "siab dua npog qis dua."

Khoom siv: txuam lub thawv rau qib thiab ib puag ncig

Handholes thiab manholes yog tsim los ntawm plaub yam khoom siv dav hauv tsev neeg, thiab qhov kev xaiv zoo yog qhov sib npaug ntawm cov khoom thauj, txhim kho kev ua haujlwm, ib puag ncig corrosion, thiab tus nqi thauj khoom. Tsis muaj cov khoom siv "zoo tshaj" thoob ntiaj teb - muaj cov khoom siv zoo tshaj plawsrau koj qhov chaw thiab qib.

Composite (SMC) thiab polymer pob zeb yog cov niaj hnub fiber ntau handhole specs vim hais tias lawv ncav cuag cov tsheb thauj mus los - cov theem tseem ceeb thaum tseem lub teeb txaus rau nruab yam tsis muaj cov cuab yeej nqa hnyav. Kwv yees nruab qhov hnyav rau 24 × 36 × 24 unit: HDPE 35-50 lb; SMC / composite 90-140 lb; polymer qhob 220-420 lb; precast qhob 800–2,{13}} lb - qhov sib txawv qhov hnyav yog qhov txiav txim siab seb koj xav tau lub crane lossis lub tsheb thauj khoom.

 

Khoom siv Lub zog pauv - tawm Yam haum
Precast qhob Muaj peev xwm thauj khoom siab heev; pov thawj rau nkag tau manholes; huab hwm coj resists flotation Hnyav - xav tau ib lub crane/boom tsheb rau qhov chaw; qeeb nruab; tuaj yeem tawg / tawg Manholes, hnyav- tsheb loj-tier vaults
Polymer pob zeb Siab compressive zog ntawm lub teeb yuag dua precast; corrosion-resistant Tseem hnyav heev; tus nqi ntau dua rau ib chav High-tier (15/22) cov tes tuav hauv kev khiav tsheb- thaj chaw uas nyob ib sab
HDPE (siab{0}} ntom polyethylene) Lub teeb yuag, tus nqi qis, txhim kho sai, corrosion- pov thawj Tsawg load tiers; zoo tshaj plaws nyob deb ntawm lub tsheb thauj khoom Cov chaw nyob, lub teeb - khoom siv, toj roob hauv pes rub cov ntsiab lus
SMC / composite (daim ntawv molding compound) Muaj zog-rau- hnyav, tsis yog-corrosive, feem ntau ob-tus neeg nruab yam tsis muaj crane; ua tiav rau Tier 15/22 Hwm tshaj HDPE; tier nyob ntawm cov khoom tshwj xeeb Telecom handholes/vaults hla feem ntau OSP daim ntawv thov

 

Lub kaum sab xis ua haujlwm yog ncaj nraim rau ntawm daim ntawv tab sis underweighted hauv kev xyaum. A 24 × 36 × 24 SMC composite handhole - feem ntau 90–140 lb - teeb tsa los ntawm lub txaj tuaj tos hauv ib teev nrog ob tus kws tshaj lij thiab lub tsheb tsheb. Ib lub polymer- pob zeb vault ntawm qib sib npaug yuav tsum muaj lub crane me me lossis lub tsheb loj ntawm qhov chaw. Ib qho kev ua vaj tse precast ntawm 800–2, 500+ lb yuav tsum tau teem caij crane; nyob rau hauv Teb Chaws Asmeskas kev lag luam, crane lossis boom- tsheb thauj mus los ntxiv $600–$1,500 rau ib lub nqa nyob ntawm qhov chaw nkag thiab hauv nroog vs. Hla 50- taw tes FTTH tsim, kev teeb tsa kev ua haujlwm thiab crane- tus nqi them nqi rau precast tuaj yeem tshaj cov nqi khoom sib txawv - ntau zaus los ntawm ob mus rau peb zaug ntawm kev txwv hauv nroog nrog kev txwv tsis pub dhau. Cov lej lej ntawd yog qhov tseeb yog vim li cas SMC cov khoom sib xyaw thiab cov khoom siv polymer- cov tes ua pob zeb tau hloov chaw precast rau txhua yam tsis yog - nkag mus rau fiber ntau cov ntsiab lus, tawm hauv precast thiab cov qauv sib xyaw loj rau cov manholes tiag tiag qhov twg cov duct-bank scale thiab cov neeg ua haujlwm nkag mus rau cov khoom siv.

Sizing los ntawm fiber ntau, splice kaw, thiab khoov vojvoog

Thaum nkag mus thiab thauj khoom tiav lawm, qhov loj yog tsav los ntawm peb yam: tus lej thiab sab nraud ntawm cov kab hluav taws xob, qhov sib txuas kaw yuav tsum tuav, thiab - tus neeg yuav khoom tsis nco qab - qhovcable qhov tsawg kawg nkaus khoov vojvoog. Ib lub thawv uas haum rau qhov kaw ntawm daim ntawv tab sis yuam kom lub cable rau hauv ib qho kev khoov nruj dua li nws lub vojvoog ntsuas yuav ua rau muaj kev cuam tshuam thiab muaj kev pheej hmoo ntev ntev - fiber ntau qaug zog.

Field-cov ntaub ntawv pov thawj ntau qhov sib tham tau muab ib daim ntawv qhia pib muaj txiaj ntsig (qhov loj me li L × W × D hauv nti):

  • 12 × 12 × 12 mus rau 12 × 12 × 18:me me rub cov ntsiab lus, qis - suav poob nkag, tsis muaj qhov sib txuas kaw.
  • 17 × 30 × 24 thiab 24 × 36 × 24:lub workhorse FTTH qhov ntau thiab tsawg - xis rau cables mus txog ~ 144 cores ntxiv rau lub compact kaw thiab slack loops.
  • 24 × 36 × 36 thiab 30 × 48 × 36:nruab nrab - loj vaults rau 288+ core qaum qaum cable nrog loj kaw thiab dav slack.
  • 48 × 60 × 48 thiab nce:cov vaults loj muaj peev xwm ntawm 576+ core cable thiab ntau qhov kaw - ntawm qhov ntsuas no koj feem ntau txiav txim siab seb tus qauv yuav tsum tsuas yog los ua ib qho chaw nkag mus xwb.

Qhov tseem ceeb, khoom slack. Splice ua hauj lwm xav tau cable coj mus rau saum npoo los yog mus rau lub rooj ntev zaum - kev taw qhia rau underground cog hu rau ib tug loj slack ntawm splice qhov chaw kom lub kaw yuav rov qab tau - nkag mus tsis muaj zog. Lub tsev teev ntuj loj uas tsis muaj nyiaj txiag tsis txaus yog lub tsev khaws puav pheej uas yuam ib nrab - ncua kev txiav ntawm kev kho tom ntej.

Txuas qhov kaw rau lub vault - tsis yog lwm txoj hauv kev

Xaiv qhov kaw ua ntej, tom qab ntawd loj lub vault nyob ib ncig ntawm nws ntxiv rau slack thiab khoov vojvoog. Peb compactdome splice kawpoob rau hauv me me handholes thiab pedestals, thaumkab rov tav / inline kawhaum ncaj nraim -los ntawm txoj kab ciav hlau - thiab peb tshaj tawm qhov ntev thiab qhov hnyav yog li koj tuaj yeem paub meej tias qhov muab hle hneev taw ua tau raws li nws. Yog tias koj tseem hnyav kaw topology, pebdome vs inline kaw phau ntawv qhiataug kev txiav txim kom meej.

Qhov teeb meem tsis muaj leej twg specs rau: underground vaults dej nyab

Nug ib tus neeg sab nraud- cog cov qub tub rog dab tsi tua cov splices hauv av, thiab cov lus teb tsis yog lub thawv ua tsis tau qhov kev xeem thauj khoom. Nws yog dej. Underground fiber vaults - handholes and manholes alike - dej nyab. Tsis yog ib qho kev zam: raws li kev ua haujlwm ib txwm muaj, txhua lub caij ntub dej, hauv txhua qhov kev nyab xeeb nrog rau lub caij los nag lossis lub rooj dej hloov pauv. Qhib-hauv qab lossis gravel-raws li kev tsim kho lub tsev pheeb suab yog txhob txwm (nws txwv tsis pub flotation), tab sis nws txhais tau tias dej nkag mus tau dawb. Lub chamber puv.

Cov txheej txheem tsis ua haujlwm zoo ib yam: qhib- hauv qab lossis pob zeb- raws li cov vaults zaum hauv cov av saturated, lub rooj dej nce raws caij nyoog, thiab lub chamber puv. OTDR cov ntaub ntawv los ntawm cov nroj tsuag hauv av hauv dej nyab-xws li los yog av nplaum- cov av xa tawm qhia tus yam ntxwv kos npe - qhov poob ntawm qhov chaw vault yuav nce ntxiv ntsuas tom qab lub caij ntub dej thiab qee qhov rov qab los thaum lub sij hawm qhuav, qhov ntsuas ntiv tes ntawm kev kaw kev sib khi uas yog cycling {6} kev tiv thaiv tsis muaj dej nyab. Lub vault ua raws nraim li tsim. Qhov kaw hauv nws tsis.

Rau tooj liab, submersion yog kev puas tsuaj. Rau fiber ntau, iav nws tus kheej yog tiv thaiv kab mob - tab sis kev tiv thaiv splice, lub foob kaw, thiab cov khoom siv hlau tsis yog. Qhov no yog vim li cas lub enclosure tsuas yog ib nrab ntawm cov specification. Covkawkoj muab tso rau hauv nws yuav tsum tau rated kom nyob underwater.

Qhov ntsuas ntawd yogIP68hauv qabIEC 60529, Ua: plua plav- nruj (thawj tus lej "6") thiab tsis tu ncua immersion- tiv thaiv ntawm cov xwm txheej pom zoo ntawm cov chaw tsim khoom thiab cov neeg siv (tus lej "8"). Qhov tseem ceeb nuance yog tias IEC 60529 txhais tsis muaj ib qho universal IP68 qhov tob lossis ntev - qhov tob tob thiab lub sijhawm sib tham thiab teev rau ib yam khoom. Qhov kaw tau siv tau ntawm 1 m rau 24 teev thiab ib qho siv tau ntawm 3 m rau 72 teev nqa cov ntawv nplaum zoo tib yam. Rau underground vaults nyob rau hauv cov cheeb tsam uas muaj raws caij nyoog lub rooj dej siab los yog av nplaum av, ib tug yam tsawg kawg nkaus procurement specification ntawm3 m qhov tob / 72-teev ntevyog tsim nyog. Rau cov chaw uas tsis tshua muaj dej hauv av tsis tu ncua, 1 m / 24 xuab moos tuaj yeem txaus - tab sis qhov tshwj xeeb yuav tsum tau hais txog qhov yuav tsum tau ua kom meej, tsis txhob tso tseg tom qab daim ntawv lo "IP68". Qhov tseem ceeb sib npaug yog foob re-entrability: lub tshav kub-shrink kaw, ib zaug qhib, yuav tsum tau re-crimping thiab re-sealing; lub tshuab gasket kaw tuaj yeem rov- nkag thiab rov- kaw hauv thaj teb yam tsis muaj cov cuab yeej tshwj xeeb lossis cov cuab yeej cua sov, uas tseem ceeb rau txhua lub tsev khaws puav pheej uas yuav rov tuaj xyuas dua.

Cov neeg yuav khoom ua rau ib qho hauv qab no -qib splice point

Xav tias lub vault dej nyab. Qhia meej txog qhov kaw rau kev tso dej mus tas li, tsis muaj kev tiv thaiv txaws: hais txog qhov ntsuas IP68 qhov tob thiab lub sijhawm sau ntawv (tsawg kawg 3 m / 72 teev rau dej nyab- qhov chaw nyob), yuav tsum tau rov ua dua - siv tshuab foob rau txhua lub tsev khaws puav pheej uas yuav rov tuaj xyuas, thiab paub meej tias kev ua haujlwm foob los ntawm kev rov ntub / qhuav. Lub handhole khaws cov khib nyiab thiab tsheb thauj mus los ntawm qhov sib txuas. Qhov kaw kom cov dej tawm. Ob qho kev qhia tshwj xeeb muaj nyob rau tib daim duab.

Lub moj khaum kev txiav txim siab koj tuaj yeem khiav ntawm txhua txoj kev

Muab cov lus hauv qab no tso ua ke: ntawm no yog qhov kev txiav txim siab ua ntu zus uas daws qhov "vault" tsis meej pem ntawm txhua txoj kev kos duab.

1
Txiav txim siab nkag siab ua ntej - tsis loj

Yuav ib tug neeg ua hauj lwm puas yuav tsum tausab hauvtus qauv ua haujlwm? Yog tias qhov kaw kaw tuaj yeem nqa mus rau saum npoo, rov- nkag, thiab qis rov qab, koj xav tau ib lub qhov thiab koj khaws txhua qhov kev mus ntsib yav tom ntej kom tsis txhob raug kaw - txoj cai lij choj chaw. Reserve manholes rau tiag tiag hauv-vault ua haujlwm - suav siab, lub tsev txhab nyiaj loj loj, hnyav rub tawm.

2
Teem lub load tier los ntawm qhov saum npoo nws

Txoj kev deb ntawm txoj kev → Tier 8. Ncua- nyob ib sab lossis tsav tsheb / chaw nres tsheb / tawm - txoj kev → Tier 15 lossis 22. Nyob rau hauv txoj kev taug kev → qhov no yog AASHTO H-20 thaj chaw, tsis yog SCTE 77. Paub meej tias cov khoom raug kuaj rau qib, nws tus kheej.

3
Xaiv cov khoom siv rau qib + kev ua haujlwm + corrosion

HDPE rau lub teeb, tsis yog - tsheb rub cov ntsiab lus; composite (SMC) los yog polymer pob zeb rau kev khiav tsheb - qhov chaw nyob ib sab uas ob tus neeg tseem tuaj yeem tso; precast los yog loj composite rau nkag tau manholes. Nyhav zam crane mobilizations, tsis yog nqi tsev xwb.

4
Loj nyob ib ncig ntawm lub kaw, slack, thiab khoov vojvoog

Xaiv lub splice kaw ua ntej, ces loj lub vault los tuav nws ntxiv slack loops tsis ua txhaum lub cable qhov tsawg kawg nkaus khoov vojvoog. Kev siv nyiaj tsawg kawg yog ib qho yav tom ntej re-splice.

5
Qhia qhov kaw rau immersion

Xav tias lub vault dej nyab. Yuav tsum tau IP68 rau IEC 60529 nrog rau qhov tob thiab lub sijhawm, nyiam dua - nkag tau cov tshuab foob rau cov chaw khaws ntaub ntawv rov los xyuas dua, thiab txheeb xyuas tus cwj pwm ntawm kev caij tsheb ntub / qhuav. Lub thawv tiv thaiv kev thauj khoom thiab khib nyiab; qhov kaw tiv thaiv dej.

Tib neeg kuj nug - cov lus teb ncaj nraim

Q: Dab tsi yog qhov tseeb lub neej tus nqi sib txawv ntawm fiber ntau handhole thiab telecom manhole?

A: Tus nqi siv pej xeem feem ntau yog qhov me me ntawm qhov sib txawv. Lub precast telecom manhole sau kwv yees li $ 2,500– $ 5,000 ntsia; ib qho sib npaug -tier SMC composite handhole khiav $600–$1,400. Cov kab loj dua yog ua haujlwm: txhua qhov chaw nkag mus rau hauv lub qhov manhole ntxiv 45–90 feeb ntawm cov nyiaj siv ua haujlwm - tso cai npaj, ntsuas huab cua, cov neeg ua haujlwm pabcuam - thiab yuav tsum muaj tsawg kawg yog ob tus kws tshaj lij. Ntawm US fiber ntau- cov neeg coob tus nqi ntawm $ 65–85 / hr, txhua qhov kev mus xyuas manhole raug nqi kwv yees li $ 230– $ 300 ntau dua li qhov sib npaug ntawm qhov kev mus ntsib. Rau 30- nkag mus- txoj kev taw qhia nrog plaub qhov kev saib xyuas hauv ib xyoos dhau 20-xyoo lub neej khoom vaj khoom tsev, cov khoom siv nyiaj siv ua haujlwm mus txog kwv yees li $ 552,000- $ 720,000 hauv cov neeg ua haujlwm, tawm tsam ib zaug ntawm pej xeem tus nqi sib txawv ntawm $ 45,000- $ 90,000. Lub qhov rooj yog ib qho khoom siv nyiaj txiag. Txoj cai nkag yog kev siv nyiaj txiag. Qhov kev txiav txim siab uas tsav tus lej loj dua yog kev nkag mus rau lub hom phiaj, tsis yog cov khoom siv lossis qib.

Q: Dab tsi yog qhov txawv ntawm lub qhov rooj thiab lub qhov manhole?

A: Qhov kev txiav txim siab sib txawv yog kev nkag mus rau cov neeg ua haujlwm. Lub manhole yog lub chamber loj thiab tob txaus rau tus neeg ua haujlwm nce mus rau hauv thiab ua haujlwm sab hauv; ib tug handhole yog ib tug ntiav enclosure tus kws tshaj lij ncav cuag los ntawm qhov chaw tsis muaj lub cev nkag. Kev tsim kho tuaj yeem ua tau zoo sib xws - lawv txawv ntawm kev ua haujlwm, tsis yog qhov loj me xwb. Qhov txiaj ntsig zoo yog tias nkag mus rau hauv qhov manhole ua rau raug kaw -cov cai tswj kev nyab xeeb hauv chaw, thaum ncav cuag - hauv qhov ua haujlwm ntawm tes tsis ua haujlwm.

Q: Puas yog lub hnab ntim fiber ntau zoo ib yam li lub qhov rooj?

A: Feem ntau yog - "fiber vault," "fiber optic vault," "rub box," thiab "joint/splice pit" yog cov lus sib piv rau lub qhov tuav. Tab sis "vault" yog qee zaus siv rau qhov loj dua, nkag mus rau hauv cov qauv, yog li qhov kev ntsuam xyuas txhim khu kev qha tsis yog lo lus: paub meej tias tus neeg puas yuav tsum nkag mus rau nws mus ua haujlwm.

Q: Puas yog fiber ntau manhole yuav tsum muaj kev txwv -qhov chaw tso cai?

A: Hauv Teb Chaws Asmeskas, lub xov tooj ntawm tes yog qhov chaw kaw, thiab kev nkag mus yog tswj hwm los ntawm tus qauv kev sib txuas lus ntawm 29 CFR 1910.268(o), nrog rau daim ntawv tso cai -required confined-chaw standard 29 CFR 1910.146 thov qhov chaw telecom tsis muaj kev nyab xeeb. Hauv kev xyaum, kev nkag mus yuav tsum muaj kev sim huab cua, qhov cua, tus neeg saib xyuas, thiab kev npaj cawm. Lub tes tsho ua haujlwm tsuas yog los ntawm qhov chaw tsis ua rau cov luag haujlwm no - uas yog ib qho loj tshaj plaws zais tus nqi sib txawv ntawm ob.

Q: ANSI / SCTE 77 Tier 22 txhais li cas?

A: Tier 22 yog ANSI / SCTE 77 tsis yog- txhob txwm tshaj tawm- chav kawm tsheb nrog tus qauv tsim ntawm 22,000 lb thiab qhov ntsuas qhov hnyav ntawm 33,750 lb (50% siab dua). Nws haum rau txoj kev tsav tsheb, chaw nres tsheb, thiab tawm ntawm- thaj chaw ntawm txoj kev uas muaj cov tsheb thauj khoom qee zaus. Nws tsis yog qhov kev ntaus nqi rau cov thawv nyob rau hauv txoj kev taug kev - uas yuav tsum tau AASHTO H-20/H-25.

Q: Puas yog Tier 22 handhole kuj ua tau raws li Tier 15?

A: Tsis tau. Peb qhov - txoj haujlwm xeem geometry txawv ntawm qib, yog li cov khoom lag luam yuav tsum raug txheeb xyuas rau txhua qib nws thov nws tus kheej. Nug cov chaw tsim khoom uas tier(s) cov khoom tshwj xeeb tau sim rau, es tsis yog xav tias qib siab dua npog qhov qis dua.

Q: Kuv xav tau qhov loj npaum li cas rau 144-core fiber cable?

A: Qhov ntau thiab tsawg workhorse rau ~ 144- tub ntxhais cable ntxiv rau lub kaw lus kaw thiab slack yog 17 × 30 × 24 "thiab 24 × 36 × 24" (L × W × D). Rau 288+ core qaum, nce mus txog 24 × 36 × 36 ″ lossis 30 × 48 × 36 ″. Ib txwm me me rau qhov kaw, lub voj voog slack, thiab lub cable qhov tsawg kawg nkaus khoov vojvoog - tsis yog lub cable xwb.
Puas tuaj yeem nqa lub qhov los yog qhov manhole rau hauv txoj kev?
Tsuas yog nrog qhov ntsuas qhov tseeb. ANSI/SCTE 77 tiers npog tsis yog - txhob txwm tsheb khiav (lub thawv tsheb hla qee zaus thiab qee zaus). Ib lub thawv hauv txoj kev taug kev tiag tiag xav tau AASHTO H-20 txhob txwm tshaj tawm- kev ntaus nqi. Kev qhia txog SCTE 77 qib rau qhov chaw nyob hauv txoj kab yog qhov ua yuam kev.

Q: Kuv yuav ua li cas thiaj ua tau ib qho kev sib tshuam hauv av los ntawm dej nyab?

A: Koj tsis khaws lub tsev khaws puav pheej los ntawm dej nyab - koj xav tias nws yuav thiab tiv thaiv cov splice hauv nws. Siv lub splice kaw qhov ntsuas IP68 rau IEC 60529 nrog rau qhov hais txog qhov tob tob thiab lub sijhawm, nyiam qhov rov ua dua -enterable mechanical seals rau vaults uas yuav rov tuaj xyuas dua, thiab paub meej tias kev ua tau zoo ntawm kev foob dua li rov ntub / qhuav.

Ib daim ntawv teev cov neeg yuav khoom

Rau ib qho chaw nkag mus hauv av ntawm txoj kev fiber ntau, txiav txim siab thiab sau ntawv:

  1. Nkag mus rau lub hom phiaj- handhole (nce -in) lossis manhole (nkag)? Yog tias qhov kaw kaw tuaj yeem ua haujlwm los ntawm qhov chaw, ua haujlwm rau lub qhov rooj thiab zam lub tsev tsis pub dhau - qhov chaw nkag mus rau txhua qhov kev mus ntsib yav tom ntej.
  2. Load tier vs. deg siv- qhov tseeb ANSI/SCTE 77 tier (5/8/15/22) rau saum npoo av, lossis AASHTO H-20 yog tias nws zaum hauv txoj kab taug kev. Paub meej tias cov khoom tau kuaj nws tus kheej mus rau theem nws thov.
  3. Tsimthiabtest load ob leeg hais- txheeb xyuas tus neeg muag khoom hais txog tus qauv tsim thiab 50%- kev ntsuas siab dua kom raug rau qib, tsis yog ib tus lej dhau los ua lwm yam.
  4. Cov khoom sib phim rau tier, kev ua haujlwm, thiab corrosion- HDPE, composite/SMC, polymer pob zeb, lossis precast - nrog rau qhov tseeb nruab- kev ua haujlwm thiab crane, tsis yog nqi tsev xwb.
  5. Internal loj rau kaw + slack + khoov vojvoog- qhov luaj li cas nyob ib ncig ntawm qhov tseeb kaw thiab slack-storage xav tau, hwm lub cable qhov tsawg kawg nkaus khoov vojvoog thiab pob nyiaj siv rau ib tug yav tom ntej re-splice.
  6. Kaw qhov ntsuas rau immersion- IP68 rau IEC 60529 nrog cov ntaub ntawv qhov tob thiab lub sijhawm, rov- nkag tau rau kev sib khi rau cov vaults uas tau rov los xyuas dua, thiab txheeb xyuas tus cwj pwm ntub / qhuav.
  7. Kev ywg dej, av, thiab sau npe- gravel base/drainage to grade, grounding provisions where need, thiab ib lub hau sau npe rau kev siv xov tooj/kev sib txuas lus.
Nyeem tus neeg xa khoom

Tus neeg muag khoom uas tuaj yeem hais lus tau yooj yim kom nkag mus rau lub hom phiaj, qhov tseeb SCTE 77 tsim / kuaj qhov sib txawv, kev teeb tsa hnyav thiab crane xav tau los ntawm cov khoom siv, thiab IP68 qhov tob thiab lub sijhawm tom qab ib qho kev kaw tshwj xeeb tau ua haujlwm cov kev no. Tus neeg muag khoom uas teb "Tier 22, lub thawv loj tshaj plaws, muaj zog heev" tau nyeem ib daim ntawv qhia, tsis yog tus qauv. Peb lo lus nug uas cais ob:(1) Dab tsi yog qhov tsim qauv thiab qhov kev xeem thauj khoom rau Tier 15?(Yog: 15,000 lb tsim / 22,500 lb xeem.)(2) Qhov ntsuas IP68 ntawm qhov kaw no qhia txog dab tsi rau qhov tob thiab lub sijhawm?(Yog: hais txog qhov tob thiab sijhawm, tsis yog "IP68.")(3) Qhov kev kaw no puas tuaj yeem rov- nkag thiab rov- kaw hauv thaj teb yam tsis muaj cov cuab yeej cua sov?(Txawm li cas los xij rau txhua lub tsev khaws puav pheej uas yuav rov tuaj xyuas dua.) Tus neeg muag khoom uas teb tag nrho peb qhov raug yog ib qho uas nws cov lus qhia yuav tuav hauv av.

Handhole piv rau manhole tsis yog ib qho kev txiav txim siab hnav khaub ncaws hauv ob lo lus - nws yog lub sijhawm koj xaiv koj lub network tswj kev tswj hwm rau ob xyoo tom ntej. Xaiv ib lub manhole thiab koj tau xaiv qhov chaw nyob tsis pub dhau - qhov chaw tso cai, ob- cov neeg ua haujlwm, kev sim huab cua, thiab kev npaj cawm rau txhua qhov kev sib tshuam yav tom ntej. Xaiv ib tug handhole thiab koj tau xaiv ib tug kws kho mob nrog ib tug nuv. Cov qauv pej xeem yog tus nqi ib zaug -; kev nkag mus rau tsoom fwv tebchaw ntawm txhua lub tsheb yob.

Txhua yam hauv qab no ua raws li qhov kev hu ntawd. Lub load tier ua raws li saum npoo ntawm lub thawv. Cov khoom ua raws li qib, kev ua haujlwm, thiab qhov chaw corrosion. Qhov luaj li cas raws li qhov kaw, slack, thiab khoov vojvoog. Thiab hauv qab ntawm txhua qhov nws zaum qhov tseeb qhov chaw qhia qhia: lub tsev pheeb suab yuav dej nyab, yog li kev kaw hauv nws - nws qhov ntsuas IP68, nws hom foob, nws tus cwj pwm los ntawm lub caij ntub dej - tseem ceeb npaum li cov pob zeb nyob ib puag ncig nws.

Tus neeg muag khoom tsim nyog rau kev sib raug zoo ntev - tsis yog muag koj lub thawv xwb. Lawv tuaj yeem sib tham txog kev nkag mus rau lub hom phiaj, hais ANSI / SCTE 77 tsim thiab kuaj cov khoom kom raug yam tsis muaj kev sib txuas ntawm ob tus lej, thiab txheeb xyuas qhov tseeb IP68 qhov tob thiab lub sijhawm rau koj qhov chaw hauv av hauv av. Qhov zoo ntawm qhov kev sib tham ntawd yog qhov qhia ncaj qha ntawm qhov chaw hauv av vs. daim ntawv qhia txog kev paub - thiab nws txiav txim siab seb koj qhov kev qhia tshwj xeeb tuav txog 10 xyoo rau hauv lub neej khoom vaj khoom tsev, thawj zaug cov neeg ua haujlwm qhib lub qhov rooj hauv nruab nrab ntawm cov ntub dej - lub caij nyoog.

Glory Optical tau tsim IP68- ntsuas splice kaw thiab OSP enclosures rau ISO 9001: 2015, CE, thiab RoHS cov qauv txij li xyoo 2008, thiab xa mus rau cov neeg ua haujlwm hauv 50+ lub teb chaws. Yog hais tias koj xav kom siab-sim ib txoj kev tsim tawm tsam lub moj khaum no, tshawb xyuas pebfiber optic enclosures thiab splice kaw, tshuaj xyuas covua tiav fiber ntau lub thawv tus neeg yuav khoom phau ntawv qhia, los yogtiv tauj peb pab pawg engineeringnrog koj cov cable suav, tej yam kev mob saum npoo av, thiab dej -cov ntaub ntawv. Nqa txoj kev specification. Peb yuav muab kaw qhov ntsuas rau nws.

Xa kev nug